A. J. Clemmens
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
A. J. Clemmens has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Tony L. Wahl
U.S. Bureau of Reclamation, Hydraulic Investigations and Laboratory Services Group
2 shared publications - Gilles Belaud
Univ. Montpellier
1 shared publication - Peter Jules van Overloop
Delft University of Technology
1 shared publication - Robert Strand
Center Director, Water Management and Conservation Research Unit, U.S. Arid Land Agricultural Research Center, 21881 North Cardon Ln., Maricopa, AZ 85238
1 shared publication - Xavier Litrico
Senior Hydraulic Engineer, WEST Consultants, Inc., 8950 52nd St. Suite 210, Tempe, AZ 85284; formerly, Center Director, U.S. Arid Land Agricultural Research Center, 21881 N. Cardon Lane, Maricopa, AZ 85138
1 shared publication
Latest Publications
- 1 February 2026
- Published by American Society of Civil Engineers (ASCE) in Journal of Irrigation and Drainage Engineering
- Vol. 152 (1)
Revised Energy Losses for Free-Flow Radial Gate Calibration
- 1 February 2026
- Published by American Society of Civil Engineers (ASCE) in Journal of Irrigation and Drainage Engineering
- Vol. 152 (1)
Revised Energy Losses for Free-Flow Radial Gate Calibration
- 1 October 2022
- Published by American Society of Civil Engineers (ASCE) in Journal of Irrigation and Drainage Engineering
- Vol. 148 (10) , 04022036
Calibration of Free-Flow Radial Gates with Refined Energy Relations
Laboratory experiments were conducted on a radial gate to evaluate the energy equation for free-flow calibration. The experiments were used to develop new equations for the radial gate contraction coefficient for free flow. These were compared to equations for the contraction coefficient of radial and vertical sluice gates developed from prior studies and potential flow theory. The new radial gate free-flow contraction coefficient was related to both the gate lip angle and the gate opening relative to the energy head on the gate. The pressure distribution and velocity distribution coefficients were also evaluated. The energy loss through the gate was expressed as a function of the velocity head in the vena contracta, with a gate energy loss coefficient that varies with the relative gate opening. With the revised energy equations, the free-flow discharge predictions were computed for three data sets: (1) experiments presented here conducted at the USWCL laboratory in 2004–2005, (2) experiments performed by Jan Tel in 2000 and earlier using the same USWCL facility operated over a narrower range of conditions, and (3) experiments performed in the early 1980s by Clark Buyalski in the Bureau of Reclamation’s hydraulics laboratory. The coefficients were developed based on the later USWCL data only. The average discharge computation error for the combined data sets was 0.37%, and the standard deviation was 1.03%. Submerged flow predictions are the subject of future work.
- 1 October 2022
- Published by American Society of Civil Engineers (ASCE) in Journal of Irrigation and Drainage Engineering
- Vol. 148 (10) , 04022036
Calibration of Free-Flow Radial Gates with Refined Energy Relations
Laboratory experiments were conducted on a radial gate to evaluate the energy equation for free-flow calibration. The experiments were used to develop new equations for the radial gate contraction coefficient for free flow. These were compared to equations for the contraction coefficient of radial and vertical sluice gates developed from prior studies and potential flow theory. The new radial gate free-flow contraction coefficient was related to both the gate lip angle and the gate opening relative to the energy head on the gate. The pressure distribution and velocity distribution coefficients were also evaluated. The energy loss through the gate was expressed as a function of the velocity head in the vena contracta, with a gate energy loss coefficient that varies with the relative gate opening. With the revised energy equations, the free-flow discharge predictions were computed for three data sets: (1) experiments presented here conducted at the USWCL laboratory in 2004–2005, (2) experiments performed by Jan Tel in 2000 and earlier using the same USWCL facility operated over a narrower range of conditions, and (3) experiments performed in the early 1980s by Clark Buyalski in the Bureau of Reclamation’s hydraulics laboratory. The coefficients were developed based on the later USWCL data only. The average discharge computation error for the combined data sets was 0.37%, and the standard deviation was 1.03%. Submerged flow predictions are the subject of future work.
- Open Access
- 1 January 2012
- Published by American Society of Civil Engineers (ASCE) in Journal of Irrigation and Drainage Engineering
- Vol. 138 (1) , 9-15
Estimating Canal Pool Resonance with Auto Tune Variation
The integrator-delay (ID) model is commonly used to model canal pools that do not exhibit resonance behavior. Simple step tests are often used to estimate ID model parameters; namely, delay time and backwater surface area. These step tests change the canal inflow at the upstream end of the pool and observe water depth variations at the downstream end. Some knowledge of the canal pool characteristics are needed to determine the amount of flow change and its duration. Auto tune variation (ATV) is one method for determining the duration of these step tests. Pools that are under backwater over their entire length tend to exhibit oscillations attributable to resonance waves. Random Binary Sequence (RBS) tests have been used to determine the resonance frequency of such pools, for which step tests with different durations are used. RBS tests are difficult to implement in practice and may not provide the resonance frequency. The intent of this paper is to demonstrate on a real canal that the ATV method can determine both the resonance frequency and the resonance-peak height for canal pools whose water levels oscillate.
- 1 January 2012
- Published by American Society of Civil Engineers (ASCE) in Journal of Irrigation and Drainage Engineering
- Vol. 138 (1) , 9-15
Open AccessEstimating Canal Pool Resonance with Auto Tune Variation
The integrator-delay (ID) model is commonly used to model canal pools that do not exhibit resonance behavior. Simple step tests are often used to estimate ID model parameters; namely, delay time and backwater surface area. These step tests change the canal inflow at the upstream end of the pool and observe water depth variations at the downstream end. Some knowledge of the canal pool characteristics are needed to determine the amount of flow change and its duration. Auto tune variation (ATV) is one method for determining the duration of these step tests. Pools that are under backwater over their entire length tend to exhibit oscillations attributable to resonance waves. Random Binary Sequence (RBS) tests have been used to determine the resonance frequency of such pools, for which step tests with different durations are used. RBS tests are difficult to implement in practice and may not provide the resonance frequency. The intent of this paper is to demonstrate on a real canal that the ATV method can determine both the resonance frequency and the resonance-peak height for canal pools whose water levels oscillate.