Markus O. Schoelmerich
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Markus O. Schoelmerich has a total of 196 co-authors. Here are the top co-authors by number of shared publications:
- O. L. Landen
Lawrence Livermore National Laboratory
4 shared publications - Tilo Doppner
Lawrence Livermore National Laboratory
4 shared publications - Dirk O. Gericke
University of Warwick
3 shared publications - Dominik Kraus
Helmholtz-Zentrum Dresden-Rossendorf
3 shared publications - Julian Lütgert
Institut für Physik, Universität Rostock, Rostock, Germany
3 shared publications L. Divol
Lawrence Livermore National Laboratory 5 , Livermore, California 94550, USA
3 shared publications
Latest Publications
- Top Cited PapersOpen Access
- 21 May 2025
- Published by Springer Nature in Nature
- Vol. 642 (8067) , 351-355
The structure of liquid carbon elucidated by in situ X-ray diffraction
Carbon has a central role in biology and organic chemistry, and its solid allotropes provide the basis of much of our modern technology1. However, the liquid form of carbon remains nearly uncharted2, and the structure of liquid carbon and most of its physical properties are essentially unknown3. But liquid carbon is relevant for modelling planetary interiors4,5 and the atmospheres of white dwarfs6, as an intermediate state for the synthesis of advanced carbon materials7,8, inertial confinement fusion implosions9, hypervelocity impact events on carbon materials10 and our general understanding of structured fluids at extreme conditions11. Here we present a precise structure measurement of liquid carbon at pressures of around 1 million atmospheres obtained by in situ X-ray diffraction at an X-ray free-electron laser. Our results show a complex fluid with transient bonding and approximately four nearest neighbours on average, in agreement with quantum molecular dynamics simulations. The obtained data substantiate the understanding of the liquid state of one of the most abundant elements in the universe and can test models of the melting line. The demonstrated experimental abilities open the path to performing similar studies of the structure of liquids composed of light elements at extreme conditions.
- 21 May 2025
- Published by Springer Nature in Nature
- Vol. 642 (8067) , 351-355
Top Cited PapersOpen AccessThe structure of liquid carbon elucidated by in situ X-ray diffraction
Carbon has a central role in biology and organic chemistry, and its solid allotropes provide the basis of much of our modern technology1. However, the liquid form of carbon remains nearly uncharted2, and the structure of liquid carbon and most of its physical properties are essentially unknown3. But liquid carbon is relevant for modelling planetary interiors4,5 and the atmospheres of white dwarfs6, as an intermediate state for the synthesis of advanced carbon materials7,8, inertial confinement fusion implosions9, hypervelocity impact events on carbon materials10 and our general understanding of structured fluids at extreme conditions11. Here we present a precise structure measurement of liquid carbon at pressures of around 1 million atmospheres obtained by in situ X-ray diffraction at an X-ray free-electron laser. Our results show a complex fluid with transient bonding and approximately four nearest neighbours on average, in agreement with quantum molecular dynamics simulations. The obtained data substantiate the understanding of the liquid state of one of the most abundant elements in the universe and can test models of the melting line. The demonstrated experimental abilities open the path to performing similar studies of the structure of liquids composed of light elements at extreme conditions.
- Open Access
- 1 January 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (1) , 013104
Developing a platform for Fresnel diffractive radiography with 1 μm spatial resolution at the National Ignition Facility
An x-ray Fresnel diffractive radiography platform was designed for use at the National Ignition Facility. It will enable measurements of micron-scale changes in the density gradients across an interface between isochorically heated warm dense matter materials, the evolution of which is driven primarily through thermal conductivity and mutual diffusion. We use 4.75 keV Ti K-shell x-ray emission to heat a 1000 μm diameter plastic cylinder, with a central 30 μm diameter channel filled with liquid D2, up to 8 eV. This leads to a cylindrical implosion of the liquid D2 column, compressing it to ∼2.3 g/cm3. After pressure equilibration, the location of the D2/plastic interface remains steady for several nanoseconds, which enables us to track density gradient changes across the material interface with high precision. For radiography, we use Cu He-α x rays at 8.3 keV. Using a slit aperture of only 1 μm width increases the spatial coherence of the source, giving rise to significant diffraction features in the radiography signal, in addition to the refraction enhancement, which further increases its sensitivity to density scale length changes at the D2/plastic interface.
- 1 January 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (1) , 013104
Open AccessDeveloping a platform for Fresnel diffractive radiography with 1 μm spatial resolution at the National Ignition Facility
An x-ray Fresnel diffractive radiography platform was designed for use at the National Ignition Facility. It will enable measurements of micron-scale changes in the density gradients across an interface between isochorically heated warm dense matter materials, the evolution of which is driven primarily through thermal conductivity and mutual diffusion. We use 4.75 keV Ti K-shell x-ray emission to heat a 1000 μm diameter plastic cylinder, with a central 30 μm diameter channel filled with liquid D2, up to 8 eV. This leads to a cylindrical implosion of the liquid D2 column, compressing it to ∼2.3 g/cm3. After pressure equilibration, the location of the D2/plastic interface remains steady for several nanoseconds, which enables us to track density gradient changes across the material interface with high precision. For radiography, we use Cu He-α x rays at 8.3 keV. Using a slit aperture of only 1 μm width increases the spatial coherence of the source, giving rise to significant diffraction features in the radiography signal, in addition to the refraction enhancement, which further increases its sensitivity to density scale length changes at the D2/plastic interface.
- 1 November 2022
- Published by AIP Publishing in Physics of Plasmas
- Vol. 29 (11) , 119903
Publisher's Note: “Platform for probing radiation transport properties of hydrogen at conditions found in the deep interiors of red dwarfs” [Phys. Plasmas 29, 083301 (2022)]
- 1 November 2022
- Published by AIP Publishing in Physics of Plasmas
- Vol. 29 (11) , 119903
Publisher's Note: “Platform for probing radiation transport properties of hydrogen at conditions found in the deep interiors of red dwarfs” [Phys. Plasmas 29, 083301 (2022)]
- Open Access
- 1 September 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (9) , 093502
Diffraction enhanced imaging utilizing a laser produced x-ray source
Image formation by Fresnel diffraction utilizes both absorption and phase-contrast to measure electron density profiles. The low spatial and spectral coherence requirements allow the technique to be performed with a laser-produced x-ray source coupled with a narrow slit. This makes it an excellent candidate for probing interfaces between materials at extreme conditions, which can only be generated at large-scale laser or pulsed power facilities. Here, we present the results from a proof-of-principle experiment demonstrating an effective ∼2 μm laser-generated source at the OMEGA Laser Facility. This was achieved using slits of 1 × 30 μm2 and 2 × 40 μm2 geometry, which were milled into 30 μm thick Ta plates. Combining these slits with a vanadium He-like 5.2 keV source created a 1D imaging system capable of micrometer-scale resolution. The principal obstacles to achieving an effective 1 μm source are the slit tilt and taper—where the use of a tapered slit is necessary to increase the alignment tolerance. We demonstrate an effective source size by imaging a 2 ± 0.2 μm radius tungsten wire.
- 1 September 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (9) , 093502
Open AccessDiffraction enhanced imaging utilizing a laser produced x-ray source
Image formation by Fresnel diffraction utilizes both absorption and phase-contrast to measure electron density profiles. The low spatial and spectral coherence requirements allow the technique to be performed with a laser-produced x-ray source coupled with a narrow slit. This makes it an excellent candidate for probing interfaces between materials at extreme conditions, which can only be generated at large-scale laser or pulsed power facilities. Here, we present the results from a proof-of-principle experiment demonstrating an effective ∼2 μm laser-generated source at the OMEGA Laser Facility. This was achieved using slits of 1 × 30 μm2 and 2 × 40 μm2 geometry, which were milled into 30 μm thick Ta plates. Combining these slits with a vanadium He-like 5.2 keV source created a 1D imaging system capable of micrometer-scale resolution. The principal obstacles to achieving an effective 1 μm source are the slit tilt and taper—where the use of a tapered slit is necessary to increase the alignment tolerance. We demonstrate an effective source size by imaging a 2 ± 0.2 μm radius tungsten wire.
- Open Access
- 1 August 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (8) , 083519
Performance of a hardened x-ray streak camera at Lawrence Livermore National Laboratory’s National Ignition Facility
Electron tubes continue to provide the highest speeds possible for recording dynamics of hot high-energy density plasmas. Standard streak camera drive electronics and CCD readout are not compatible with the radiation environment associated with high DT fusion yield inertial confinement fusion experiments >1013 14 MeV DT neutrons or >109 n cm−2 ns−1. We describe a hardened x-ray streak camera developed for the National Ignition Facility and present preliminary results from the first experiment on which it has participated, recording the time-resolved bremsstrahlung spectrum from the core of an inertial confinement fusion implosion at more than 40× the operational neutron yield limit of the previous National Ignition Facility x-ray streak cameras.
- 1 August 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (8) , 083519
Open AccessPerformance of a hardened x-ray streak camera at Lawrence Livermore National Laboratory’s National Ignition Facility
Electron tubes continue to provide the highest speeds possible for recording dynamics of hot high-energy density plasmas. Standard streak camera drive electronics and CCD readout are not compatible with the radiation environment associated with high DT fusion yield inertial confinement fusion experiments >1013 14 MeV DT neutrons or >109 n cm−2 ns−1. We describe a hardened x-ray streak camera developed for the National Ignition Facility and present preliminary results from the first experiment on which it has participated, recording the time-resolved bremsstrahlung spectrum from the core of an inertial confinement fusion implosion at more than 40× the operational neutron yield limit of the previous National Ignition Facility x-ray streak cameras.
- Open Access
- 1 August 2022
- Published by AIP Publishing in Physics of Plasmas
- Vol. 29 (8) , 083301
Platform for probing radiation transport properties of hydrogen at conditions found in the deep interiors of red dwarfs
We describe an experimental concept at the National Ignition Facility for specifically tailored spherical implosions to compress hydrogen to extreme densities (up to solid density, electron number density ) at moderate temperatures ( ), i.e., to conditions, which are relevant to the interiors of red dwarf stars. The dense plasma will be probed by laser-generated x-ray radiation of different photon energy to determine the plasma opacity due to collisional (free–free) absorption and Thomson scattering. The obtained results will benchmark radiation transport models, which in the case for free–free absorption show strong deviations at conditions relevant to red dwarfs. This very first experimental test of free–free opacity models at these extreme states will help to constrain where inside those celestial objects energy transport is dominated by radiation or convection. Moreover, our study will inform models for other important processes in dense plasmas, which are based on electron–ion collisions, e.g., stopping of swift ions or electron–ion temperature relaxation.- 1 August 2022
- Published by AIP Publishing in Physics of Plasmas
- Vol. 29 (8) , 083301
Open AccessPlatform for probing radiation transport properties of hydrogen at conditions found in the deep interiors of red dwarfs
We describe an experimental concept at the National Ignition Facility for specifically tailored spherical implosions to compress hydrogen to extreme densities (up to solid density, electron number density ) at moderate temperatures ( ), i.e., to conditions, which are relevant to the interiors of red dwarf stars. The dense plasma will be probed by laser-generated x-ray radiation of different photon energy to determine the plasma opacity due to collisional (free–free) absorption and Thomson scattering. The obtained results will benchmark radiation transport models, which in the case for free–free absorption show strong deviations at conditions relevant to red dwarfs. This very first experimental test of free–free opacity models at these extreme states will help to constrain where inside those celestial objects energy transport is dominated by radiation or convection. Moreover, our study will inform models for other important processes in dense plasmas, which are based on electron–ion collisions, e.g., stopping of swift ions or electron–ion temperature relaxation. - 22 February 2022
- Published by American Physical Society (APS) in Physical Review B
- Vol. 105 (6) , 064109
In situx-ray diffraction study of dynamically compressed-cristobalite using a dynamic diamond anvil cellIn this study we present results of the dynamic compression of -cristobalite up to a pressure of 106 GPa with the use of the dynamic diamond anvil cell. X-ray diffraction images were recorded at different ramp compression and decompression rates to investigate in situ the high-pressure phase transitions of -cristobalite. Our results suggest that the pressure onset of the phase transformation of -cristobalite to cristobalite II, cristobalite X-I, and ultimately to seifertite ( type ) is dependent on the applied compression rates and stress conditions of the experiment. Increasing compression rates in general shift the studied phase transitions to higher pressures. Furthermore, our results indicate for single crystals under hydrostatic conditions a suppression of a phase transition from cristobalite X-I to seifertite at pressures of up to 82 GPa.- 22 February 2022
- Published by American Physical Society (APS) in Physical Review B
- Vol. 105 (6) , 064109
In situx-ray diffraction study of dynamically compressed-cristobalite using a dynamic diamond anvil cellIn this study we present results of the dynamic compression of -cristobalite up to a pressure of 106 GPa with the use of the dynamic diamond anvil cell. X-ray diffraction images were recorded at different ramp compression and decompression rates to investigate in situ the high-pressure phase transitions of -cristobalite. Our results suggest that the pressure onset of the phase transformation of -cristobalite to cristobalite II, cristobalite X-I, and ultimately to seifertite ( type ) is dependent on the applied compression rates and stress conditions of the experiment. Increasing compression rates in general shift the studied phase transitions to higher pressures. Furthermore, our results indicate for single crystals under hydrostatic conditions a suppression of a phase transition from cristobalite X-I to seifertite at pressures of up to 82 GPa.