Saharnaz Esmaeili
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Saharnaz Esmaeili has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Soheil Shahbazi
Dentofacial Deformities Research Center, Research Institute of Dental Sciences, Shahid Beheshti University of Medical Sciences, Tehran, Iran
10 shared publications - Mahdi Kadkhodazadeh
Dental Research Center, Research Institute of Dental Sciences, Shahid Beheshti University of Medical Sciences, Tehran, Iran
4 shared publications - Reza Amid
Department of Periodontics, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
4 shared publications - Anahita Moscowchi
Dental Research Center, Research Institute for Dental Sciences, Shahid Beheshti University of Medical Sciences, Tehran, Iran
2 shared publications - Mohammad Asnaashari
Department of Endodontic, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
2 shared publications - Abtin Akhtari
School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran
1 shared publication
Latest Publications
- 13 November 2025
- Published by Springer Nature
- Vol. 1492, 605-624
Evaluating the Impact of Clear Dental Aligners on Dental and Periodontal Conditions, Oral Microbial Patterns, and the Immune System
Clear aligner therapy (CAT) has gained widespread adoption for managing malocclusions, primarily due to its aesthetic advantages, improved access for hygiene, and enhanced patient comfort relative to fixed appliances (FAs). However, CAT introduces a distinct intraoral environment that can influence microbial composition, biofilm development, and host immune responses. This chapter explores the effects of clear aligners on dental and periodontal health, oral microbial communities, and immunological parameters. Evidence indicates that CAT may facilitate plaque and biofilm accumulation, particularly on composite attachments, thereby increasing the risk of white spot lesions (WSLs), gingivitis, and dental caries. Despite these risks, aligners are generally associated with lower levels of pathogenic bacteria compared to FAs. Microbiome analyses of subgingival plaque and saliva reveal shifts in bacterial genera and phyla, although these changes are frequently non-pathogenic. CAT has demonstrated minimal negative effects on clinical periodontal indices, including the plaque index and gingival bleeding index, particularly when effective oral hygiene is maintained. Furthermore, aligners may reduce sustained immune activation by limiting plaque retention and aseptic inflammation, potentially decreasing the expression of pro-inflammatory cytokines such as IL-1β, IL-6, and TNF-α. Although hypersensitivity reactions to aligner materials are infrequent, they warrant consideration. Overall, CAT appears to support periodontal health and promote a more stable oral microbial environment compared to FAs. Continued patient adherence to hygiene protocols and further long-term studies are necessary to fully evaluate systemic implications and optimize clinical outcomes.
- 13 November 2025
- Published by Springer Nature
- Vol. 1492, 605-624
Evaluating the Impact of Clear Dental Aligners on Dental and Periodontal Conditions, Oral Microbial Patterns, and the Immune System
Clear aligner therapy (CAT) has gained widespread adoption for managing malocclusions, primarily due to its aesthetic advantages, improved access for hygiene, and enhanced patient comfort relative to fixed appliances (FAs). However, CAT introduces a distinct intraoral environment that can influence microbial composition, biofilm development, and host immune responses. This chapter explores the effects of clear aligners on dental and periodontal health, oral microbial communities, and immunological parameters. Evidence indicates that CAT may facilitate plaque and biofilm accumulation, particularly on composite attachments, thereby increasing the risk of white spot lesions (WSLs), gingivitis, and dental caries. Despite these risks, aligners are generally associated with lower levels of pathogenic bacteria compared to FAs. Microbiome analyses of subgingival plaque and saliva reveal shifts in bacterial genera and phyla, although these changes are frequently non-pathogenic. CAT has demonstrated minimal negative effects on clinical periodontal indices, including the plaque index and gingival bleeding index, particularly when effective oral hygiene is maintained. Furthermore, aligners may reduce sustained immune activation by limiting plaque retention and aseptic inflammation, potentially decreasing the expression of pro-inflammatory cytokines such as IL-1β, IL-6, and TNF-α. Although hypersensitivity reactions to aligner materials are infrequent, they warrant consideration. Overall, CAT appears to support periodontal health and promote a more stable oral microbial environment compared to FAs. Continued patient adherence to hygiene protocols and further long-term studies are necessary to fully evaluate systemic implications and optimize clinical outcomes.
- 18 April 2025
- Published by Wiley in Photochemistry and Photobiology
- Vol. 102 (1) , 163-197
Adjunctive photochemical therapy for management of inflammatory peri‐implant diseases: A systematic review and meta‐analysis
This study aimed to systematically review the data on interventions involving adjunctive photochemical therapy in treating peri‐implant mucositis (PIM) and peri‐implantitis (PI). The electronic search was conducted through six databases in October 2023, seeking studies relying on any kind of adjunctive photochemical therapy in treating inflammatory peri‐implant diseases (PIDs). To showcase the effect size, mean differences along with 95% confidence intervals were utilized. Forty‐seven studies were deemed eligible for qualitative synthesis, 14 of which were included in the meta‐analysis. Low‐level light therapy and photodynamic therapy led to enhanced improvements in clinical and radiographic indices, such as bone level (BL), bleeding on probing (BoP), clinical attachment level (CAL), and probing depth (PD), during the 3‐month follow‐up. However, the differences in efficacy between treatments incorporating adjunctive photochemical therapy and those relying solely on mechanical debridement, considered the gold standard, lessened over extended follow‐up periods of 6, 9, and 12 months. Significant differences were observed when comparing the treatment outcomes following adjunctive photochemical therapy between obese and smoker patients with healthy subjects. Incorporating adjunctive photochemical therapy for PID treatment might improve clinical and radiographic parameters in a short‐term follow‐up of 3 months, but longer‐term benefits appear comparable to routine treatments.
- 18 April 2025
- Published by Wiley in Photochemistry and Photobiology
- Vol. 102 (1) , 163-197
Adjunctive photochemical therapy for management of inflammatory peri‐implant diseases: A systematic review and meta‐analysis
This study aimed to systematically review the data on interventions involving adjunctive photochemical therapy in treating peri‐implant mucositis (PIM) and peri‐implantitis (PI). The electronic search was conducted through six databases in October 2023, seeking studies relying on any kind of adjunctive photochemical therapy in treating inflammatory peri‐implant diseases (PIDs). To showcase the effect size, mean differences along with 95% confidence intervals were utilized. Forty‐seven studies were deemed eligible for qualitative synthesis, 14 of which were included in the meta‐analysis. Low‐level light therapy and photodynamic therapy led to enhanced improvements in clinical and radiographic indices, such as bone level (BL), bleeding on probing (BoP), clinical attachment level (CAL), and probing depth (PD), during the 3‐month follow‐up. However, the differences in efficacy between treatments incorporating adjunctive photochemical therapy and those relying solely on mechanical debridement, considered the gold standard, lessened over extended follow‐up periods of 6, 9, and 12 months. Significant differences were observed when comparing the treatment outcomes following adjunctive photochemical therapy between obese and smoker patients with healthy subjects. Incorporating adjunctive photochemical therapy for PID treatment might improve clinical and radiographic parameters in a short‐term follow‐up of 3 months, but longer‐term benefits appear comparable to routine treatments.
- Open Access
- 19 February 2025
- Published by Springer Nature in BMC Psychology
- Vol. 13 (1) , 1-10
Self-esteem and its influence on the inclination toward esthetic dental treatments: a cross-sectional study
Facial attractiveness, influenced by dental esthetics, impacts self-perception and social interactions. The rise of social media has further fueled the demand for cosmetic dental treatments. This study aimed to examine the influence of self-esteem on the inclination of dentists, dental students, and laypeople toward esthetic dental treatments. This cross-sectional study involved 410 participants, including dentists, dental students, and laypeople, selected through convenience sampling. Data were collected using a questionnaire that captured sociodemographic characteristics, oral hygiene status, previous experience with esthetic treatments, inclinations toward esthetic dental treatments, and self-esteem levels using the Rosenberg Self-Esteem Scale (RSES). The questionnaire, created on the Porsline© website, was distributed via social media platforms. Data were analyzed using SPSS version 21, employing the Chi-square test and logistic regression, with a p-value of less than 0.05 considered statistically significant. The RSES showed that 16.3% of participants had low self-esteem, while 83.7% had high self-esteem. Among participants with previous cosmetic procedures, 84.3% expressed interest in pursuing additional treatments compared to 47.7% of those without such experience (P < 0.01). Among dental professionals, 38.3% of high and 37.5% of low self-esteem individuals expressed interest in cosmetic treatments (P = 0.42), while among laypeople, 66.6% of high and 82.2% of low self-esteem individuals indicated interest (P = 0.04). Regardless of profession, 66.7% of individuals with low self-esteem and 55.4% of those with high self-esteem expressed interest in esthetic treatments (P = 0.08). RSES scores varied significantly across age groups, with participants aged > 45 years showing the highest scores (P = 0.03). Regression analysis indicated that laypeople were more likely to seek esthetic dental treatments than dentists or dental students (OR = 3.02, 95% CI = 1.88–4.83). Participants with a history of esthetic dental treatments were also more likely to pursue further procedures (OR = 5.39, 95% CI = 2.97–9.77). Self-esteem significantly correlates with laypeople’s inclination toward cosmetic dental treatments. Dentists and dental students tend to express less interest in such procedures, likely due to their understanding of potential long-term complications. Additionally, individuals with prior experience in esthetic dental treatments showed greater interest in pursuing further treatments.
- 19 February 2025
- Published by Springer Nature in BMC Psychology
- Vol. 13 (1) , 1-10
Open AccessSelf-esteem and its influence on the inclination toward esthetic dental treatments: a cross-sectional study
Facial attractiveness, influenced by dental esthetics, impacts self-perception and social interactions. The rise of social media has further fueled the demand for cosmetic dental treatments. This study aimed to examine the influence of self-esteem on the inclination of dentists, dental students, and laypeople toward esthetic dental treatments. This cross-sectional study involved 410 participants, including dentists, dental students, and laypeople, selected through convenience sampling. Data were collected using a questionnaire that captured sociodemographic characteristics, oral hygiene status, previous experience with esthetic treatments, inclinations toward esthetic dental treatments, and self-esteem levels using the Rosenberg Self-Esteem Scale (RSES). The questionnaire, created on the Porsline© website, was distributed via social media platforms. Data were analyzed using SPSS version 21, employing the Chi-square test and logistic regression, with a p-value of less than 0.05 considered statistically significant. The RSES showed that 16.3% of participants had low self-esteem, while 83.7% had high self-esteem. Among participants with previous cosmetic procedures, 84.3% expressed interest in pursuing additional treatments compared to 47.7% of those without such experience (P < 0.01). Among dental professionals, 38.3% of high and 37.5% of low self-esteem individuals expressed interest in cosmetic treatments (P = 0.42), while among laypeople, 66.6% of high and 82.2% of low self-esteem individuals indicated interest (P = 0.04). Regardless of profession, 66.7% of individuals with low self-esteem and 55.4% of those with high self-esteem expressed interest in esthetic treatments (P = 0.08). RSES scores varied significantly across age groups, with participants aged > 45 years showing the highest scores (P = 0.03). Regression analysis indicated that laypeople were more likely to seek esthetic dental treatments than dentists or dental students (OR = 3.02, 95% CI = 1.88–4.83). Participants with a history of esthetic dental treatments were also more likely to pursue further procedures (OR = 5.39, 95% CI = 2.97–9.77). Self-esteem significantly correlates with laypeople’s inclination toward cosmetic dental treatments. Dentists and dental students tend to express less interest in such procedures, likely due to their understanding of potential long-term complications. Additionally, individuals with prior experience in esthetic dental treatments showed greater interest in pursuing further treatments.
- Open Access
- 6 January 2025
- Published by Maad Rayan Publishing Company in Journal of Advanced Periodontology & Implant Dentistry
- Vol. 17 (2) , 77-89
The association of gene polymorphisms with peri-implant mucositis and peri-implantitis: A systematic review and meta-analysis
The association of gene polymorphisms with peri-implant mucositis and peri-implantitis: A systematic review and meta-analysis
- 6 January 2025
- Published by Maad Rayan Publishing Company in Journal of Advanced Periodontology & Implant Dentistry
- Vol. 17 (2) , 77-89
Open AccessThe association of gene polymorphisms with peri-implant mucositis and peri-implantitis: A systematic review and meta-analysis
The association of gene polymorphisms with peri-implant mucositis and peri-implantitis: A systematic review and meta-analysis
- Open Access
- 15 December 2024
- Published by Wiley in Clinical Case Reports
- Vol. 12 (12)
Functional Class II Treatment Simultaneous With Selective Reduction of Talon Cusps: A Case Report
Selective reduction of bilateral nonsyndromic talon cusps in an 11‐year‐old class II patient enabled successful mandibular repositioning with a twin block appliance. This approach achieved desired orthodontic outcomes without causing pain or sensitivity following reduction, highlighting a novel strategy for managing talon cusps in orthodontic treatment.
- 15 December 2024
- Published by Wiley in Clinical Case Reports
- Vol. 12 (12)
Open AccessFunctional Class II Treatment Simultaneous With Selective Reduction of Talon Cusps: A Case Report
Selective reduction of bilateral nonsyndromic talon cusps in an 11‐year‐old class II patient enabled successful mandibular repositioning with a twin block appliance. This approach achieved desired orthodontic outcomes without causing pain or sensitivity following reduction, highlighting a novel strategy for managing talon cusps in orthodontic treatment.
- Open Access
- 28 November 2024
- Published by Wiley in Clinical and Experimental Dental Research
- Vol. 10 (6) , e70049
The Association of Matrix Metalloproteinase‐1, ‐2, ‐3, ‐7, and ‐13 Gene Polymorphisms With Peri‐Implantitis in an Iranian Population: A Case–Control Study
Objectives: Peri‐implantitis (PI) is the most common biological issue surrounding dental implants. According to current knowledge, the aforementioned complication is not equally distributed across different populations, and gene polymorphisms might be one contributing factor. The current study aimed to examine the association between gene polymorphisms of matrix metalloproteinase‐ (MMP‐) 1, ‐2, ‐3, ‐7, and ‐13 with PI in an Iranian demographic.Material and Methods: The study's sample included 50 subjects suffering from PI and 89 healthy controls. From each participant, a venous blood sample of 5 cc was obtained, and DNA was extracted. Gene polymorphisms were investigated using restriction fragment length polymorphism polymerase chain reaction (RFLP‐PCR) combined with electrophoresis. Statistical analyses were done using the Pearson chi‐square test, odds ratio, and t‐test via SPSS version 28.Results: The MMP‐3 (‐1171 5A/6A) and MMP‐7 (‐181 A/G) gene polymorphisms were significantly different between the patients with PI and healthy controls (PV < 0.001 and =0.025, respectively). MMP‐1 (‐1607 1G/2G), MMP‐2 (‐1306 C/T), and MMP‐13 (‐77 A/G) gene polymorphisms did not, however, differ in terms of prevalence between the two groups (PV > 0.05). Moreover, the presence of the 6 A allele in the MMP‐3 (‐1171 5A/6A) genotype resulted in a significant decrease in PI risk (PV < 0.001).Conclusions: Gene polymorphisms in the genotypes of MMP‐3 (‐1171 5A/6A) and MMP‐7 (‐181 A/G) were differential when comparing PI patients and healthy controls of the studied population.
- 28 November 2024
- Published by Wiley in Clinical and Experimental Dental Research
- Vol. 10 (6) , e70049
Open AccessThe Association of Matrix Metalloproteinase‐1, ‐2, ‐3, ‐7, and ‐13 Gene Polymorphisms With Peri‐Implantitis in an Iranian Population: A Case–Control Study
Objectives: Peri‐implantitis (PI) is the most common biological issue surrounding dental implants. According to current knowledge, the aforementioned complication is not equally distributed across different populations, and gene polymorphisms might be one contributing factor. The current study aimed to examine the association between gene polymorphisms of matrix metalloproteinase‐ (MMP‐) 1, ‐2, ‐3, ‐7, and ‐13 with PI in an Iranian demographic.Material and Methods: The study's sample included 50 subjects suffering from PI and 89 healthy controls. From each participant, a venous blood sample of 5 cc was obtained, and DNA was extracted. Gene polymorphisms were investigated using restriction fragment length polymorphism polymerase chain reaction (RFLP‐PCR) combined with electrophoresis. Statistical analyses were done using the Pearson chi‐square test, odds ratio, and t‐test via SPSS version 28.Results: The MMP‐3 (‐1171 5A/6A) and MMP‐7 (‐181 A/G) gene polymorphisms were significantly different between the patients with PI and healthy controls (PV < 0.001 and =0.025, respectively). MMP‐1 (‐1607 1G/2G), MMP‐2 (‐1306 C/T), and MMP‐13 (‐77 A/G) gene polymorphisms did not, however, differ in terms of prevalence between the two groups (PV > 0.05). Moreover, the presence of the 6 A allele in the MMP‐3 (‐1171 5A/6A) genotype resulted in a significant decrease in PI risk (PV < 0.001).Conclusions: Gene polymorphisms in the genotypes of MMP‐3 (‐1171 5A/6A) and MMP‐7 (‐181 A/G) were differential when comparing PI patients and healthy controls of the studied population.
- 23 August 2024
- Published by Springer Nature in Osteoporosis International
- Vol. 36 (1) , 1-19
Diagnostic accuracy of artificial intelligence models in detecting osteoporosis using dental images: a systematic review and meta-analysis
The current study aimed to systematically review the literature on the accuracy of artificial intelligence (AI) models for osteoporosis (OP) diagnosis using dental images. A thorough literature search was executed in October 2022 and updated in November 2023 across multiple databases, including PubMed, Scopus, Web of Science, and Google Scholar. The research targeted studies using AI models for OP diagnosis from dental radiographs. The main outcomes were the sensitivity and specificity of AI models regarding OP diagnosis. The “meta” package from the R Foundation was selected for statistical analysis. A random-effects model, along with 95% confidence intervals, was utilized to estimate pooled values. The Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool was employed for risk of bias and applicability assessment. Among 640 records, 22 studies were included in the qualitative analysis and 12 in the meta-analysis. The overall sensitivity for AI-assisted OP diagnosis was 0.85 (95% CI, 0.70–0.93), while the pooled specificity equaled 0.95 (95% CI, 0.91–0.97). Conventional algorithms led to a pooled sensitivity of 0.82 (95% CI, 0.57–0.94) and a pooled specificity of 0.96 (95% CI, 0.93–0.97). Deep convolutional neural networks exhibited a pooled sensitivity of 0.87 (95% CI, 0.68–0.95) and a pooled specificity of 0.92 (95% CI, 0.83–0.96). This systematic review corroborates the accuracy of AI in OP diagnosis using dental images. Future research should expand sample sizes in test and training datasets and standardize imaging techniques to establish the reliability of AI-assisted methods in OP diagnosis through dental images.
- 23 August 2024
- Published by Springer Nature in Osteoporosis International
- Vol. 36 (1) , 1-19
Diagnostic accuracy of artificial intelligence models in detecting osteoporosis using dental images: a systematic review and meta-analysis
The current study aimed to systematically review the literature on the accuracy of artificial intelligence (AI) models for osteoporosis (OP) diagnosis using dental images. A thorough literature search was executed in October 2022 and updated in November 2023 across multiple databases, including PubMed, Scopus, Web of Science, and Google Scholar. The research targeted studies using AI models for OP diagnosis from dental radiographs. The main outcomes were the sensitivity and specificity of AI models regarding OP diagnosis. The “meta” package from the R Foundation was selected for statistical analysis. A random-effects model, along with 95% confidence intervals, was utilized to estimate pooled values. The Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool was employed for risk of bias and applicability assessment. Among 640 records, 22 studies were included in the qualitative analysis and 12 in the meta-analysis. The overall sensitivity for AI-assisted OP diagnosis was 0.85 (95% CI, 0.70–0.93), while the pooled specificity equaled 0.95 (95% CI, 0.91–0.97). Conventional algorithms led to a pooled sensitivity of 0.82 (95% CI, 0.57–0.94) and a pooled specificity of 0.96 (95% CI, 0.93–0.97). Deep convolutional neural networks exhibited a pooled sensitivity of 0.87 (95% CI, 0.68–0.95) and a pooled specificity of 0.92 (95% CI, 0.83–0.96). This systematic review corroborates the accuracy of AI in OP diagnosis using dental images. Future research should expand sample sizes in test and training datasets and standardize imaging techniques to establish the reliability of AI-assisted methods in OP diagnosis through dental images.
- Open Access
- 31 July 2024
- Published by Maad Rayan Publishing Company in Journal of Advanced Periodontology & Implant Dentistry
- Vol. 16 (2) , 144-159
Surgical regenerative methods for peri-implantitis treatment: A systematic review and meta-analysis
Background. The purpose of this study was to review the literature on the efficacy of different surgical regenerative methods for peri-implantitis treatment. Methods. A preliminary search was conducted in seven electronic databases. The studies included in the analysis implemented surgical regenerative treatment in at least one study group. Baseline and follow-up values for bleeding on probing (BoP), pocket depth (PD), plaque index (PI), bone level (BL), and bone gain (BG) were extracted. The standardized mean difference (SMD) was calculated using Cohen’s d or Hedges’ g, and a random-effects-restricted maximum likelihood (REML) method was applied for the meta-analysis. Results. Fifteen studies were included in the qualitative synthesis. The meta-analysis was performed on six studies comparing regenerative techniques that involved bone grafts with those that did not. The overall effect size for using bone grafts at the one-year follow-up was 0.04 (95% CI: -0.26‒0.35; P=0.78) for BoP, -0.08 (95% CI: -0.42‒0.27; P=0.66) for PD, 0.37 (95% CI: 0.08‒0.65; P=0.01) for PI, -0.44 (95% CI: -0.84 to -0.03; P=0.03) for BL, and 0.16 (95% CI: -0.68‒1.01; P=0.70) for BG. Conclusion. Various materials have been employed for peri-implant defect filling and coverage. A bone substitute did not significantly improve BoP, PD, and BG values, while PI and BL were significantly ameliorated at one-year follow-up. However, recommending a single unified protocol as the most effective for surgical regenerative treatment of peri-implantitis was not feasible.
- 31 July 2024
- Published by Maad Rayan Publishing Company in Journal of Advanced Periodontology & Implant Dentistry
- Vol. 16 (2) , 144-159
Open AccessSurgical regenerative methods for peri-implantitis treatment: A systematic review and meta-analysis
Background. The purpose of this study was to review the literature on the efficacy of different surgical regenerative methods for peri-implantitis treatment. Methods. A preliminary search was conducted in seven electronic databases. The studies included in the analysis implemented surgical regenerative treatment in at least one study group. Baseline and follow-up values for bleeding on probing (BoP), pocket depth (PD), plaque index (PI), bone level (BL), and bone gain (BG) were extracted. The standardized mean difference (SMD) was calculated using Cohen’s d or Hedges’ g, and a random-effects-restricted maximum likelihood (REML) method was applied for the meta-analysis. Results. Fifteen studies were included in the qualitative synthesis. The meta-analysis was performed on six studies comparing regenerative techniques that involved bone grafts with those that did not. The overall effect size for using bone grafts at the one-year follow-up was 0.04 (95% CI: -0.26‒0.35; P=0.78) for BoP, -0.08 (95% CI: -0.42‒0.27; P=0.66) for PD, 0.37 (95% CI: 0.08‒0.65; P=0.01) for PI, -0.44 (95% CI: -0.84 to -0.03; P=0.03) for BL, and 0.16 (95% CI: -0.68‒1.01; P=0.70) for BG. Conclusion. Various materials have been employed for peri-implant defect filling and coverage. A bone substitute did not significantly improve BoP, PD, and BG values, while PI and BL were significantly ameliorated at one-year follow-up. However, recommending a single unified protocol as the most effective for surgical regenerative treatment of peri-implantitis was not feasible.
- Open Access
- 31 December 2022
- Published by Maad Rayan Publishing Company in Journal of Kerman University of Medical Sciences
- Vol. 29 (6) , 507-519
Effects of Age and Gender on Hard and Soft Tissue Cephalometric Features of an Iranian Population Over 12 Years Old
Background: This study aimed to investigate age- and gender-specific soft and hard tissue cephalometric features in an Iranian population with normal class I occlusion. Methods: A total of 111 Iranians (56 females and 55 males) in two age groups including individuals aged between 12-16 years and individuals aged over 16 years, with well-balanced faces and class I occlusion, were selected. Overall, 81 (40 soft tissue and 41 hard tissue) cephalometric measurements of the selected samples were traced on all cephalograms. The obtained values were compared in terms of gender and age differences and also ethnic differences between Iranian and European races. Results: This study indicated significant differences between Iranian men and women of different ages and Caucasians in terms of hard and soft tissue cephalometric measurements, which should be considered in orthodontic and surgical treatments. Some of the most important differences are greater values of facial convexity angle, nasolabial angle, and soft tissue chin thickness in Iranians than in Caucasians. Conclusion: In general, slightly more convex profiles, more protruded lips, less prominent noses, higher nose tips, and proclined and protruded central incisors are acceptable in the Iranian population. Also, Iranian women have more convex soft and hard tissue profiles, shorter anterior and posterior facial heights, larger interlabial gaps, less deep superior sulci, thinner and shorter upper lips, and thinner soft tissue chins than men. Also, non-growing adults have more advanced mandibles, larger noses, more sloping nasal tips, and larger skeletal dimensions compared with growing ones.
- 31 December 2022
- Published by Maad Rayan Publishing Company in Journal of Kerman University of Medical Sciences
- Vol. 29 (6) , 507-519
Open AccessEffects of Age and Gender on Hard and Soft Tissue Cephalometric Features of an Iranian Population Over 12 Years Old
Background: This study aimed to investigate age- and gender-specific soft and hard tissue cephalometric features in an Iranian population with normal class I occlusion. Methods: A total of 111 Iranians (56 females and 55 males) in two age groups including individuals aged between 12-16 years and individuals aged over 16 years, with well-balanced faces and class I occlusion, were selected. Overall, 81 (40 soft tissue and 41 hard tissue) cephalometric measurements of the selected samples were traced on all cephalograms. The obtained values were compared in terms of gender and age differences and also ethnic differences between Iranian and European races. Results: This study indicated significant differences between Iranian men and women of different ages and Caucasians in terms of hard and soft tissue cephalometric measurements, which should be considered in orthodontic and surgical treatments. Some of the most important differences are greater values of facial convexity angle, nasolabial angle, and soft tissue chin thickness in Iranians than in Caucasians. Conclusion: In general, slightly more convex profiles, more protruded lips, less prominent noses, higher nose tips, and proclined and protruded central incisors are acceptable in the Iranian population. Also, Iranian women have more convex soft and hard tissue profiles, shorter anterior and posterior facial heights, larger interlabial gaps, less deep superior sulci, thinner and shorter upper lips, and thinner soft tissue chins than men. Also, non-growing adults have more advanced mandibles, larger noses, more sloping nasal tips, and larger skeletal dimensions compared with growing ones.
- Open Access
- 29 September 2022
- Published by Maad Rayan Publishing Company in Journal of lasers in medical sciences
- Vol. 13, e41
Gingival Melanin Depigmentation Using a Diode 808-nm Laser: A Case Series
Introduction: Gingival hyperpigmentation is caused by an increase in the amount of melanin production or the number of melanocytes in the epithelium, which can impair smile esthetics. The current study aimed to report the experience of using a diode laser for gingival depigmentation of three different patients.Case Presentation: Three adult patients are presented with hyperpigmentation in labial gingivae of both jaws. The depigmentation was done using a diode laser at a wavelength of 808 nm, fiber diameter of 300 μm, and power of 1 W and in continuous mode. All three patients showed proper resolution of hyperpigmented areas in short- and long-term follow-up sessions. However, degrees of recurrence were noticeable in two cases.Conclusion: The 808-nm diode laser can be utilized safely and efficiently in gingival depigmentation, resulting in an acceptable cosmetic outcome.
- 29 September 2022
- Published by Maad Rayan Publishing Company in Journal of lasers in medical sciences
- Vol. 13, e41
Open AccessGingival Melanin Depigmentation Using a Diode 808-nm Laser: A Case Series
Introduction: Gingival hyperpigmentation is caused by an increase in the amount of melanin production or the number of melanocytes in the epithelium, which can impair smile esthetics. The current study aimed to report the experience of using a diode laser for gingival depigmentation of three different patients.Case Presentation: Three adult patients are presented with hyperpigmentation in labial gingivae of both jaws. The depigmentation was done using a diode laser at a wavelength of 808 nm, fiber diameter of 300 μm, and power of 1 W and in continuous mode. All three patients showed proper resolution of hyperpigmented areas in short- and long-term follow-up sessions. However, degrees of recurrence were noticeable in two cases.Conclusion: The 808-nm diode laser can be utilized safely and efficiently in gingival depigmentation, resulting in an acceptable cosmetic outcome.