Kerellos Nasr
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kerellos Nasr has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Rahul Vaidya
Detroit Medical Center, Department of Orthopedics, Detroit, MI, USA
3 shared publications - Emily Ren
Department of Orthopedic Surgery, Detroit Medical Center, Detroit, MI
2 shared publications - Abdul Kareem Zalikha
Department of Orthopaedic Surgery, Detroit Medical Center, Detroit, MI
1 shared publication - Austen Washington
Detroit Medical Center; 3990 John R Street, Harper 7-Brush, Detroit, MI 48201, USA
1 shared publication - Eric Schweller
Department of Orthopedic Surgery, Community Garden City Hospital, Garden City, MI
1 shared publication - Jonathan Joiner
Department of Orthopedic Surgery, McLaren Oakland, Pontiac, MI
1 shared publication
Latest Publications
- Open Access
- 20 December 2024
- Published by Wolters Kluwer Health in OTA International
- Vol. 8 (1) , e355
Femoral intramedullary nail extraction using the kissing nail technique when primary measures fail
Introduction: Intramedullary femoral nails (IMFNs) need to be removed for subsequent joint replacement, refracture, nonunion, or infection. The tools used to extract newer IMFNs may not be suited for removal of older implants, especially if broken. The purpose of this study was to describe a novel technique in femoral nail extraction when primary measures fail and a report on 6 cases where it was used. Technical Procedure: The technique is used after standard techniques including the Winquist set fail. A guide rod is passed through the center of the incarcerated nail (IN) to the distal end or to the proximal end if it is a retrograde nail. The femur is approached through a separate incision either through the knee for an antegrade nail or through the proximal femur for a retrograde nail. The guide rod is delivered through the opposite end by either hitting it through the end of the bone or breaching the end with a starting wire and starting reamer. The guide rod is then delivered into the field. Using flexible reamers over the delivered guide rod, the femur is reamed up to the IN. A second IMN slightly smaller in diameter is chosen and passed to touch the distal end of the IN, guided by the guide rod to keep the nails aligned. The second nail is impacted, which pushes the IN out its insertion point. Discussion: Hardware extraction is difficult for any surgeon, and extraction of older or broken nails with lower grade material poses even greater challenges. This technique is meant as an extra tool for avoidance of corticotomy when primary means for nail extraction have failed. We present 6 cases with 5 successful results.
- 20 December 2024
- Published by Wolters Kluwer Health in OTA International
- Vol. 8 (1) , e355
Open AccessFemoral intramedullary nail extraction using the kissing nail technique when primary measures fail
Introduction: Intramedullary femoral nails (IMFNs) need to be removed for subsequent joint replacement, refracture, nonunion, or infection. The tools used to extract newer IMFNs may not be suited for removal of older implants, especially if broken. The purpose of this study was to describe a novel technique in femoral nail extraction when primary measures fail and a report on 6 cases where it was used. Technical Procedure: The technique is used after standard techniques including the Winquist set fail. A guide rod is passed through the center of the incarcerated nail (IN) to the distal end or to the proximal end if it is a retrograde nail. The femur is approached through a separate incision either through the knee for an antegrade nail or through the proximal femur for a retrograde nail. The guide rod is delivered through the opposite end by either hitting it through the end of the bone or breaching the end with a starting wire and starting reamer. The guide rod is then delivered into the field. Using flexible reamers over the delivered guide rod, the femur is reamed up to the IN. A second IMN slightly smaller in diameter is chosen and passed to touch the distal end of the IN, guided by the guide rod to keep the nails aligned. The second nail is impacted, which pushes the IN out its insertion point. Discussion: Hardware extraction is difficult for any surgeon, and extraction of older or broken nails with lower grade material poses even greater challenges. This technique is meant as an extra tool for avoidance of corticotomy when primary means for nail extraction have failed. We present 6 cases with 5 successful results.
- Open Access
- 28 December 2023
- Published by Wolters Kluwer Health in OTA International
- Vol. 7 (1) , e298
Antibiotic cement nails manufactured with threaded rods or cannulated intramedullary nails are better than those made with guidewires and do not debond
Purpose: The purpose of this study was to comparatively evaluate cement debonding at the time of removal of antibiotic cemented coated nails (ABNs) with cores made with a guidewire ($120), a regular intramedullary nail ($1100) or a threaded rod from a circular frame external fixator set ($60). Methods: A retrospective study was performed on 32 ABNs that had been implanted for long bone infections after intramedullary nailing. All ABNs were manufactured intraoperatively by the treating surgeon using 2 grams of vancomycin and single package of Tobramycin Simplex Cement (Stryker, Kalamazoo, MI). The powder, antibiotics, and polymer were mixed and then injected into an ABN cement mold (Bonesetter Holdings USA). Debonding was assessed at time of removal by the operating surgeon. Rates of cement debonding between the 3 groups were statistically compared. Results: Debonding occurred in 0/12 of the cement nails manufactured with an intramedullary nail, 0/7 threaded rod ABNs, and 6/13 guidewire ABNs. There was a significant difference in the rate of debonding between the 3 groups (P < 0.01). Removal of the remnant cement was accomplished with thin osteotomes, long pituitary rongeurs, or reamers. The canal was visualized using an arthroscope to ensure complete removal of the cement. Conclusion: ABNs fabricated with standard intramedullary nails or threaded rods did not lead to any debonding. Debonding of the cement from the inner core of an antibiotic nail often requires significant effort to remove the remnant cement. Given that threaded rods are often cheaper than guidewires, we recommend that ABNs be fabricated with either threaded rods or interlocking nails, but not guidewires, depending on the level of stability required.
- 28 December 2023
- Published by Wolters Kluwer Health in OTA International
- Vol. 7 (1) , e298
Open AccessAntibiotic cement nails manufactured with threaded rods or cannulated intramedullary nails are better than those made with guidewires and do not debond
Purpose: The purpose of this study was to comparatively evaluate cement debonding at the time of removal of antibiotic cemented coated nails (ABNs) with cores made with a guidewire ($120), a regular intramedullary nail ($1100) or a threaded rod from a circular frame external fixator set ($60). Methods: A retrospective study was performed on 32 ABNs that had been implanted for long bone infections after intramedullary nailing. All ABNs were manufactured intraoperatively by the treating surgeon using 2 grams of vancomycin and single package of Tobramycin Simplex Cement (Stryker, Kalamazoo, MI). The powder, antibiotics, and polymer were mixed and then injected into an ABN cement mold (Bonesetter Holdings USA). Debonding was assessed at time of removal by the operating surgeon. Rates of cement debonding between the 3 groups were statistically compared. Results: Debonding occurred in 0/12 of the cement nails manufactured with an intramedullary nail, 0/7 threaded rod ABNs, and 6/13 guidewire ABNs. There was a significant difference in the rate of debonding between the 3 groups (P < 0.01). Removal of the remnant cement was accomplished with thin osteotomes, long pituitary rongeurs, or reamers. The canal was visualized using an arthroscope to ensure complete removal of the cement. Conclusion: ABNs fabricated with standard intramedullary nails or threaded rods did not lead to any debonding. Debonding of the cement from the inner core of an antibiotic nail often requires significant effort to remove the remnant cement. Given that threaded rods are often cheaper than guidewires, we recommend that ABNs be fabricated with either threaded rods or interlocking nails, but not guidewires, depending on the level of stability required.
- Open Access
Pelvic Malunion: A Systematic Review, Dichotomy of Definitions and Treatment
Background and Objectives: Pelvic nonunion and malunion have been documented as rare complications in pelvic fractures and literature describing these topics is severely limited. Articles dedicated solely to pelvic malunion are nearly nonexistent. We conducted a literature search with the goal of providing a summary of the definition, causes, treatment strategies, and outcomes of pelvic malunion correction. Materials and Methods: An initial review of the literature was performed using the PubMed, ScienceDirect, and Cochrane Database of Systematic Reviews databases. Search terms used were “malunion” AND “pelvic” OR “pelvis”. Duplicate articles, non-English language articles without translations available and non-human subject studies were excluded. Results: Eleven original publications were found describing experiences with pelvic malunion. Seven of the articles were exclusively dedicated to the topic of pelvic fracture malunion, and only two reported on a series of patients treated for malunion with variably staged procedures. Most reports define pelvic pain as the main indication for surgical correction, along with gait disturbance, standing or sitting imbalance, and urinary or sexual dysfunction. Radiographically, vertical displacement of one to two centimeters and rotation of the hemipelvis of fifteen degrees or more have been described in defining malunion. No treatment algorithms exist, and each patient is treated with a unique work-up and operative plan due to the complexity of the problem. Only one series reported a patient satisfaction rate of 75% following malunion treatment. Conclusions: Pelvic malunion is a rare complication of pelvic ring injury and is seldom discussed in the literature. We found two small case series reporting exclusively on malunion treatment and complications. While some of the combination studies made the distinction in the diagnosis of malunion and nonunion, they rarely differentiated the treatment outcomes between the two categories. This paper describes pelvic malunion and highlights the need for more research into surgical outcomes of treatment specifically regarding functionality, patient satisfaction, and recurrence of preoperative symptoms.
Open AccessPelvic Malunion: A Systematic Review, Dichotomy of Definitions and Treatment
Background and Objectives: Pelvic nonunion and malunion have been documented as rare complications in pelvic fractures and literature describing these topics is severely limited. Articles dedicated solely to pelvic malunion are nearly nonexistent. We conducted a literature search with the goal of providing a summary of the definition, causes, treatment strategies, and outcomes of pelvic malunion correction. Materials and Methods: An initial review of the literature was performed using the PubMed, ScienceDirect, and Cochrane Database of Systematic Reviews databases. Search terms used were “malunion” AND “pelvic” OR “pelvis”. Duplicate articles, non-English language articles without translations available and non-human subject studies were excluded. Results: Eleven original publications were found describing experiences with pelvic malunion. Seven of the articles were exclusively dedicated to the topic of pelvic fracture malunion, and only two reported on a series of patients treated for malunion with variably staged procedures. Most reports define pelvic pain as the main indication for surgical correction, along with gait disturbance, standing or sitting imbalance, and urinary or sexual dysfunction. Radiographically, vertical displacement of one to two centimeters and rotation of the hemipelvis of fifteen degrees or more have been described in defining malunion. No treatment algorithms exist, and each patient is treated with a unique work-up and operative plan due to the complexity of the problem. Only one series reported a patient satisfaction rate of 75% following malunion treatment. Conclusions: Pelvic malunion is a rare complication of pelvic ring injury and is seldom discussed in the literature. We found two small case series reporting exclusively on malunion treatment and complications. While some of the combination studies made the distinction in the diagnosis of malunion and nonunion, they rarely differentiated the treatment outcomes between the two categories. This paper describes pelvic malunion and highlights the need for more research into surgical outcomes of treatment specifically regarding functionality, patient satisfaction, and recurrence of preoperative symptoms.