Yuichi Torisu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yuichi Torisu has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Masafumi Chiba
Department of Endoscopy, The Jikei University School of Medicine, Tokyo 105-8461, Japan
2 shared publications - Masanori Nakano
Division of Gastroenterology and Hepatology, Department of Internal Medicine, The Jikei University School of Medicine, 3-25-8 Nishi-Shimbashi, Minato-ku, Tokyo 105-8461, Japan
2 shared publications - Masayuki Kato
Department of Endoscopy The Jikei University Katsushika Medical Center Tokyo Japan
2 shared publications - Nana Shimamoto
Department of Endoscopy, The Jikei University School of Medicine, Tokyo 105-8471, Japan
2 shared publications - Takafumi Akasu
Division of Gastroenterology and Hepatology, Department of Internal Medicine, The Jikei University School of Medicine, Tokyo 105-8471, Japan
2 shared publications - Takahiro Abe
Department of Endoscopy, The Jikei University Katsushika Medical Center, 6-41-2 Aoto Katsushika-ku, Tokyo, 125-8506, Japan
2 shared publications
Latest Publications
- Open Access
- 11 January 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (2) , 230
Endoscopic Ultrasound-Lavage Technique for Pancreatic Cancer: An In Vivo Pilot Study
Background: Pancreatic cancer (PC) has a very poor 5-year survival and prognosis. Even when CT or MRI shows no metastasis, staging laparoscopy(SL) still detects tiny peritoneal deposits in 20–30% of patients, making them ineligible for surgery. SL is invasive, requiring general anesthesia and substantial resources. Endoscopic ultrasound (EUS) allows the observation of the bile ducts, pancreas, and abdominal cavity, and EUS-guided fine-needle aspiration (EUS-FNA) is essential for pathological diagnosis. Reports on using EUS to perform peritoneal lavage cytology are currently not available. We hypothesized that combining EUS-FNA with peritoneal lavage (EUS-lavage technique; EUS-LT) could enhance staging accuracy and avoid unnecessary surgical procedures. Methods: Ten in vivo porcine models underwent EUS-LT. Using a 19G FNA needle, 800 mL saline was instilled into the intraperitoneal cavity and then recovered. Two refinements were introduced sequentially: an ENBD catheter with additional side holes and, subsequently, a side-hole introducer (EndoSheather) that eliminated balloon dilation. The primary endpoint was procedural success. Secondary endpoints included safety, complications, recovered volume, duration of endoscopic procedure, and time required to instill 800 mL. Nonparametric tests compared outcomes across iterations. Results: Ten-model porcine in vivo model series were included, and all procedures were successful. No device malfunctions or unanticipated technical failures; one minor mucosal injury during saline injection resolved after re-puncture. The average procedure time was 31.1 min. Stepwise refinements shortened procedure and infusion times and increased recovered volume. Recovered volume approached the instilled amount in later cases, indicating efficient performance. Conclusions: In this ten-model in vivo series, EUS-LT demonstrated technical feasibility and short-term safety.
- 11 January 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (2) , 230
Open AccessEndoscopic Ultrasound-Lavage Technique for Pancreatic Cancer: An In Vivo Pilot Study
Background: Pancreatic cancer (PC) has a very poor 5-year survival and prognosis. Even when CT or MRI shows no metastasis, staging laparoscopy(SL) still detects tiny peritoneal deposits in 20–30% of patients, making them ineligible for surgery. SL is invasive, requiring general anesthesia and substantial resources. Endoscopic ultrasound (EUS) allows the observation of the bile ducts, pancreas, and abdominal cavity, and EUS-guided fine-needle aspiration (EUS-FNA) is essential for pathological diagnosis. Reports on using EUS to perform peritoneal lavage cytology are currently not available. We hypothesized that combining EUS-FNA with peritoneal lavage (EUS-lavage technique; EUS-LT) could enhance staging accuracy and avoid unnecessary surgical procedures. Methods: Ten in vivo porcine models underwent EUS-LT. Using a 19G FNA needle, 800 mL saline was instilled into the intraperitoneal cavity and then recovered. Two refinements were introduced sequentially: an ENBD catheter with additional side holes and, subsequently, a side-hole introducer (EndoSheather) that eliminated balloon dilation. The primary endpoint was procedural success. Secondary endpoints included safety, complications, recovered volume, duration of endoscopic procedure, and time required to instill 800 mL. Nonparametric tests compared outcomes across iterations. Results: Ten-model porcine in vivo model series were included, and all procedures were successful. No device malfunctions or unanticipated technical failures; one minor mucosal injury during saline injection resolved after re-puncture. The average procedure time was 31.1 min. Stepwise refinements shortened procedure and infusion times and increased recovered volume. Recovered volume approached the instilled amount in later cases, indicating efficient performance. Conclusions: In this ten-model in vivo series, EUS-LT demonstrated technical feasibility and short-term safety.
- Open Access
- 16 August 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (8) , 1983
Diagnostic Dilemma of Biliopancreatic Contrast-Enhanced Harmonic Endoscopic Ultrasonography
Background: The utility of contrast-enhanced harmonic endoscopic ultrasonography (CH-EUS) alone in the biliopancreatic region appears to be limited because it is highly dependent on the experience and skill of the endoscopist. Therefore, the present study aimed to validate the efficacy of CH-EUS in clinical practice. Methods: Between January 2018 and March 2019, 301 consecutive patients who underwent CH-EUS were prospectively enrolled in this study. The diagnostic performance of CH-EUS was compared with that of dynamic computed tomography (CT), magnetic resonance imaging (MRI), and all combinations (i.e., CH-EUS, dynamic CT, and MRI) using a Bonferroni correction. A multiple logistic regression analysis was performed to extract each disease that allowed the CH-EUS diagnosis to be consistent with the final diagnosis. Results: In multiple comparisons of diagnostic performance, no significant differences were observed among dynamic CT, MRI, and CH-EUS (p = 1.00), but the diagnostic performance was significantly higher when all modalities were combined (p < 0.001). Moreover, only intraductal papillary mucinous neoplasm comprising adenoma or carcinoma (IPMN, n = 161) showed significance with respect to the agreement with the final diagnosis (p = 0.006). Conclusions: Our results showed that CH-EUS-based diagnosis of IPMN may be possible in clinical practice. On the contrary, to accurately diagnose biliopancreatic diseases other than IPMN, comprehensive diagnosis using multiple modalities may be necessary, rather than relying on CH-EUS alone.
- 16 August 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (8) , 1983
Open AccessDiagnostic Dilemma of Biliopancreatic Contrast-Enhanced Harmonic Endoscopic Ultrasonography
Background: The utility of contrast-enhanced harmonic endoscopic ultrasonography (CH-EUS) alone in the biliopancreatic region appears to be limited because it is highly dependent on the experience and skill of the endoscopist. Therefore, the present study aimed to validate the efficacy of CH-EUS in clinical practice. Methods: Between January 2018 and March 2019, 301 consecutive patients who underwent CH-EUS were prospectively enrolled in this study. The diagnostic performance of CH-EUS was compared with that of dynamic computed tomography (CT), magnetic resonance imaging (MRI), and all combinations (i.e., CH-EUS, dynamic CT, and MRI) using a Bonferroni correction. A multiple logistic regression analysis was performed to extract each disease that allowed the CH-EUS diagnosis to be consistent with the final diagnosis. Results: In multiple comparisons of diagnostic performance, no significant differences were observed among dynamic CT, MRI, and CH-EUS (p = 1.00), but the diagnostic performance was significantly higher when all modalities were combined (p < 0.001). Moreover, only intraductal papillary mucinous neoplasm comprising adenoma or carcinoma (IPMN, n = 161) showed significance with respect to the agreement with the final diagnosis (p = 0.006). Conclusions: Our results showed that CH-EUS-based diagnosis of IPMN may be possible in clinical practice. On the contrary, to accurately diagnose biliopancreatic diseases other than IPMN, comprehensive diagnosis using multiple modalities may be necessary, rather than relying on CH-EUS alone.