Parnika Shrivastava
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Parnika Shrivastava has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Arun Sharma
Department of Mechanical Engineering, Dr B. R. Ambedkar National Institute of Technology Jalandhar, Jalandhar, India
2 shared publicationsPriyanshu Soni
School of Biomedical Engineering, Indian Institute of Technology BHU, Varanasi, India
2 shared publicationsSanjay Kumar Rai
School of Biomedical Engineering, Indian Institute of Technology BHU, Varanasi, India
2 shared publicationsAbhra Bhattacharyya
School of Biomedical Engineering, Indian Institute of Technology BHU, Varanasi, India
1 shared publication- Amrut Mulay
Department of Mechanical Engineering, Sardar Vallabhbhai National Institute of Technology, Surat, India
1 shared publication Aniket Nagargoje
School of Mechanical Engineering, MIT Academy of Engineering, Pune, India
1 shared publication
Latest Publications
- 30 October 2026
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering
Elevated-temperature single-point incremental forming for biomedical implants: Microstructural evolution and dimensional precision
Incremental forming offers a flexible approach for manufacturing patient specific implants with complex asymmetric geometries. Titanium is ideal for biomedical implants due to biocompatibility and corrosion resistance but exhibits limited room temperature formability. Elevated temperatures can improve formability during single point incremental forming of titanium sheets, but the material response under such forming conditions is still not fully understood. In this study, a heat assisted single point incremental forming setup with cartridge heaters was developed to fabricate a patient-specific cranial implant geometry from commercially pure titanium grade 2 sheets at 204 °C. Geometric accuracy was evaluated using material thickness distribution, springback and geometric deviation analysis. The deformation behaviour during elevated temperature single point incremental forming was investigated through microstructural and texture evolution using electron backscatter diffraction analysis at progressive forming depths. The formed implant exhibited relatively uniform thickness distribution and limited springback, with a maximum bend angle of 5.991°. Microstructural analysis revealed significant grain refinement, with the average grain size decreasing from 16 to 1 μm and the fraction of low-angle grain boundaries increasing from 18.6% to 32.2%. Texture evolution was characterized by progressive weakening of the initial rolling texture and increasing orientation dispersion, with only a weak tendency towards alignment along the { 1 ¯ 2 1 ¯ 8 } fibre at higher forming depths. The electron backscatter diffraction observations indicate progressive grain subdivision, substructural evolution and continuous redistribution of crystallographic orientations during elevated-temperature single point incremental forming. The observed microstructural features are also suggestive of localized recovery processes at higher forming depths.
- 30 October 2026
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering
Elevated-temperature single-point incremental forming for biomedical implants: Microstructural evolution and dimensional precision
Incremental forming offers a flexible approach for manufacturing patient specific implants with complex asymmetric geometries. Titanium is ideal for biomedical implants due to biocompatibility and corrosion resistance but exhibits limited room temperature formability. Elevated temperatures can improve formability during single point incremental forming of titanium sheets, but the material response under such forming conditions is still not fully understood. In this study, a heat assisted single point incremental forming setup with cartridge heaters was developed to fabricate a patient-specific cranial implant geometry from commercially pure titanium grade 2 sheets at 204 °C. Geometric accuracy was evaluated using material thickness distribution, springback and geometric deviation analysis. The deformation behaviour during elevated temperature single point incremental forming was investigated through microstructural and texture evolution using electron backscatter diffraction analysis at progressive forming depths. The formed implant exhibited relatively uniform thickness distribution and limited springback, with a maximum bend angle of 5.991°. Microstructural analysis revealed significant grain refinement, with the average grain size decreasing from 16 to 1 μm and the fraction of low-angle grain boundaries increasing from 18.6% to 32.2%. Texture evolution was characterized by progressive weakening of the initial rolling texture and increasing orientation dispersion, with only a weak tendency towards alignment along the { 1 ¯ 2 1 ¯ 8 } fibre at higher forming depths. The electron backscatter diffraction observations indicate progressive grain subdivision, substructural evolution and continuous redistribution of crystallographic orientations during elevated-temperature single point incremental forming. The observed microstructural features are also suggestive of localized recovery processes at higher forming depths.
- 28 August 2026
- Published by World Scientific Pub Co Pte Ltd in Journal of Mechanics in Medicine and Biology
ENHANCING RADIOTHERAPY SAFETY IN HEAD AND NECK CANCER TREATMENT: A HYBRID DOUBLE-LAYERED ORTHODONTIC MOUTH GUARD
Radiotherapy is a widely used method in the treatment of head-and-neck cancers; however, irradiation of surrounding oral structures often results in clinical complications such as dental caries, oral mucositis, osteoradionecrosis, dysphagia, dysgeusia, xerostomia and trismus. To address such issues, a patient-specific hybrid double-layer orthodontic mouthguard has been proposed to simultaneously enhance the radiation shielding and biomechanical comfort in treatments. The customized device integrates radiation-shielding dental covers, a compliant soft-liner layer, a tongue depressor, oral positioning stents and cheek displacement stents to safeguard critical oral structures. Finite element analysis has been done to quantify stress transmissions to the mandibular dentition under static oral-stent loading. An initial single-layer configuration without the soft cover has been analyzed to demonstrate the stresses without using any intermediate layer. Subsequently, a double-layer configuration incorporating a 0.5-mm cushioning layer was investigated using six biocompatible materials: Polylactic Acid (PLA), Polyethylene Terephthalate (PET), Polyetheretherketone (PEEK), Thermoplastic Polyurethane (TPU), Polytetrafluoroethylene (PTFE) and Polymethyl Methacrylate (PMMA). Among the materials evaluated, TPU offered the most effective stress mitigation, lowering the peak equivalent stress by nearly 39% compared to the single-layer configuration. Subsequent thickness optimization further highlighted the importance of the soft inner lining: a 2-mm TPU layer delivered the best performance, reducing the maximum stress to 14.98[Formula: see text]MPa, a drop of about 64% relative to the original design. It demonstrated that a double-layer mouthguard not only reduces stress concentrations more efficiently across the dentition but also maintains reliable radioprotective functionality. As a result, this proposed double-layer mouthguard design provides strong advancement for enhancing patient comfort and protecting oral tissue and provides precision treatment during head-and-neck radiotherapy, supporting its potential for future clinical adoption.
- 28 August 2026
- Published by World Scientific Pub Co Pte Ltd in Journal of Mechanics in Medicine and Biology
ENHANCING RADIOTHERAPY SAFETY IN HEAD AND NECK CANCER TREATMENT: A HYBRID DOUBLE-LAYERED ORTHODONTIC MOUTH GUARD
Radiotherapy is a widely used method in the treatment of head-and-neck cancers; however, irradiation of surrounding oral structures often results in clinical complications such as dental caries, oral mucositis, osteoradionecrosis, dysphagia, dysgeusia, xerostomia and trismus. To address such issues, a patient-specific hybrid double-layer orthodontic mouthguard has been proposed to simultaneously enhance the radiation shielding and biomechanical comfort in treatments. The customized device integrates radiation-shielding dental covers, a compliant soft-liner layer, a tongue depressor, oral positioning stents and cheek displacement stents to safeguard critical oral structures. Finite element analysis has been done to quantify stress transmissions to the mandibular dentition under static oral-stent loading. An initial single-layer configuration without the soft cover has been analyzed to demonstrate the stresses without using any intermediate layer. Subsequently, a double-layer configuration incorporating a 0.5-mm cushioning layer was investigated using six biocompatible materials: Polylactic Acid (PLA), Polyethylene Terephthalate (PET), Polyetheretherketone (PEEK), Thermoplastic Polyurethane (TPU), Polytetrafluoroethylene (PTFE) and Polymethyl Methacrylate (PMMA). Among the materials evaluated, TPU offered the most effective stress mitigation, lowering the peak equivalent stress by nearly 39% compared to the single-layer configuration. Subsequent thickness optimization further highlighted the importance of the soft inner lining: a 2-mm TPU layer delivered the best performance, reducing the maximum stress to 14.98[Formula: see text]MPa, a drop of about 64% relative to the original design. It demonstrated that a double-layer mouthguard not only reduces stress concentrations more efficiently across the dentition but also maintains reliable radioprotective functionality. As a result, this proposed double-layer mouthguard design provides strong advancement for enhancing patient comfort and protecting oral tissue and provides precision treatment during head-and-neck radiotherapy, supporting its potential for future clinical adoption.
- 25 August 2026
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering
Influence of nanostructured solid lubricants on friction, wear, and surface topography during SPIF of CP-Ti Grade 2 implant
Single point incremental forming has emerged as a promising method for the customized fabrication of titanium biomedical components. However, severe tool–sheet interaction during single point incremental forming can lead to high friction, tool wear, and surface degradation, compromising implant performance and long-term biocompatibility. To address these challenges, this study investigates the tribological behavior and surface topography of commercially pure titanium Grade 2 using different families of nanostructured solid lubricants, including ceramic (ZrO 2 ), polymeric (polytetrafluoroethylene), transition metal dichalcogenide (MoS 2 ), and carbon-based (graphene) lubricants. The lubricants were characterized using scanning electron microscopy and energy-dispersive spectroscopy to confirm their morphology and elemental composition. Tribological performance was evaluated using pin-on-disk tests with titanium Grade 2 as the disk material and tungsten carbide as the counterface pin. The results revealed a clear performance hierarchy among the nanostructured solid lubricants. MoS 2 exhibited the lowest coefficient of friction (0.12) and wear rate (1.6 × 10 −4 mm 3 /N·m), followed by polytetrafluoroethylene (coefficient of friction: 0.15; wear rate: 2.3 × 10 −4 mm 3 /N·m), graphene (coefficient of friction: 0.16; wear rate: 3.4 × 10 −4 mm 3 /N·m), and ZrO 2 showing the highest friction (0.27) and wear rate (3.9 × 10 −4 mm 3 /N·m). Wear track analysis confirmed these trends, with MoS 2 producing the smallest wear track width (549.75 µm) and ZrO 2 the widest (1195.24 µm). Scanning electron microscopy observations indicated distinct wear mechanisms: ZrO 2 promoted abrasive wear, graphene exhibited mixed adhesive and lamellar sliding behavior, polytetrafluoroethylene formed a stable transfer film, and MoS 2 generated a protective lamellar tribofilm. Surface topography analysis of single point incremental forming-formed components showed that MoS 2 produced the best surface finish (Ra = 1.289 µm), followed by polytetrafluoroethylene (Ra = 1.579 µm), graphene (Ra = 2.259 µm), and ZrO 2 (Ra = 4.063 µm). Although MoS 2 exhibited superior tribological performance, polytetrafluoroethylene exhibited stable transfer-film-assisted lubrication, and based on its reported biocompatibility, remains a potential lubricant pending biological validation.
- 25 August 2026
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering
Influence of nanostructured solid lubricants on friction, wear, and surface topography during SPIF of CP-Ti Grade 2 implant
Single point incremental forming has emerged as a promising method for the customized fabrication of titanium biomedical components. However, severe tool–sheet interaction during single point incremental forming can lead to high friction, tool wear, and surface degradation, compromising implant performance and long-term biocompatibility. To address these challenges, this study investigates the tribological behavior and surface topography of commercially pure titanium Grade 2 using different families of nanostructured solid lubricants, including ceramic (ZrO 2 ), polymeric (polytetrafluoroethylene), transition metal dichalcogenide (MoS 2 ), and carbon-based (graphene) lubricants. The lubricants were characterized using scanning electron microscopy and energy-dispersive spectroscopy to confirm their morphology and elemental composition. Tribological performance was evaluated using pin-on-disk tests with titanium Grade 2 as the disk material and tungsten carbide as the counterface pin. The results revealed a clear performance hierarchy among the nanostructured solid lubricants. MoS 2 exhibited the lowest coefficient of friction (0.12) and wear rate (1.6 × 10 −4 mm 3 /N·m), followed by polytetrafluoroethylene (coefficient of friction: 0.15; wear rate: 2.3 × 10 −4 mm 3 /N·m), graphene (coefficient of friction: 0.16; wear rate: 3.4 × 10 −4 mm 3 /N·m), and ZrO 2 showing the highest friction (0.27) and wear rate (3.9 × 10 −4 mm 3 /N·m). Wear track analysis confirmed these trends, with MoS 2 producing the smallest wear track width (549.75 µm) and ZrO 2 the widest (1195.24 µm). Scanning electron microscopy observations indicated distinct wear mechanisms: ZrO 2 promoted abrasive wear, graphene exhibited mixed adhesive and lamellar sliding behavior, polytetrafluoroethylene formed a stable transfer film, and MoS 2 generated a protective lamellar tribofilm. Surface topography analysis of single point incremental forming-formed components showed that MoS 2 produced the best surface finish (Ra = 1.289 µm), followed by polytetrafluoroethylene (Ra = 1.579 µm), graphene (Ra = 2.259 µm), and ZrO 2 (Ra = 4.063 µm). Although MoS 2 exhibited superior tribological performance, polytetrafluoroethylene exhibited stable transfer-film-assisted lubrication, and based on its reported biocompatibility, remains a potential lubricant pending biological validation.
- 26 May 2026
- Published by Springer Nature in Transactions of the Indian Institute of Metals
- Vol. 79 (6) , 124
Numerical Thickness Based Conforming Toolpath Strategy for Double-Sided Incremental Sheet Forming
- 26 May 2026
- Published by Springer Nature in Transactions of the Indian Institute of Metals
- Vol. 79 (6) , 124
Numerical Thickness Based Conforming Toolpath Strategy for Double-Sided Incremental Sheet Forming
- 2 December 2025
- Published by Springer Nature in Journal of Materials Engineering and Performance
- Vol. 35 (17) , 16763-16784
Formability Enhancement and Post-forming Characterization of AA7075-T6 Material in SPIF Process
- 2 December 2025
- Published by Springer Nature in Journal of Materials Engineering and Performance
- Vol. 35 (17) , 16763-16784
Formability Enhancement and Post-forming Characterization of AA7075-T6 Material in SPIF Process
- 13 October 2025
- Published by Springer Nature in Journal of Materials Engineering and Performance
- Vol. 35 (10) , 9655-9667
Investigating the Role of Reinforced Cube Texture in Enhanced Formability and Subsequent Deformation Texture of Incrementally Formed AA 1050 Sheets
- 13 October 2025
- Published by Springer Nature in Journal of Materials Engineering and Performance
- Vol. 35 (10) , 9655-9667
Investigating the Role of Reinforced Cube Texture in Enhanced Formability and Subsequent Deformation Texture of Incrementally Formed AA 1050 Sheets
- 12 July 2025
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 139 (5-6) , 2847-2865
Precision forming of titanium implants: enhancing surface and microstructural characteristics with a highest curvature locus and feature-driven tool path strategy in SPIF
- 12 July 2025
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 139 (5-6) , 2847-2865
Precision forming of titanium implants: enhancing surface and microstructural characteristics with a highest curvature locus and feature-driven tool path strategy in SPIF