Peng Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Peng Liu has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Wu Yuan
Department of Biomedical Engineering, The Chinese University of Hong Kong, Hong Kong SAR, China
3 shared publications - Bing Li
Harbin Institute of Technology
2 shared publications - Calvin Sze Hang Ng
Division of Cardiothoracic Surgery, Department of Surgery, The Chinese University of Hong Kong, Prince of Wales Hospital
2 shared publications - Chao Xu
Department of Biomedical Engineering, The Chinese University of Hong Kong, Hong Kong SAR, China
2 shared publications - Tinghua Zhang
Department of Biomedical Engineering, Chinese University of Hong Kong, Hong Kong, China
2 shared publications - Yao Li
Guangdong Provincial Key Laboratory of Intelligent Morphing Mechanisms and Adaptive Robots, Shenzhen, China
2 shared publications
Latest Publications
- Open Access
- 1 November 2024
- Published by AIP Publishing in APL Photonics
- Vol. 9 (11)
Ultrathin visible-light OCT endomicroscopy for in vivo ultrahigh-resolution neuroimaging in deep brain
Deep-brain neuroimaging, a task that demands high-resolution imaging techniques for visualizing intricate brain structures, assessing deep-seated disease histopathology, and offering real-time intervention guidance, is challenged by the resolution-depth trade-off of current methods. We propose an optical coherence tomography (OCT) endomicroscopy device for high-resolution in vivo imaging of deep brain microstructures and histopathology. A unique liquid shaping technique enables the direct fabrication of a microlens on the fiber tip of the imaging probe, optimizing imaging performance parameters, such as longitudinal focal shift, focused spot size, and working distance. In addition, a broadband visible-light source enhances axial resolution and OCT imaging contrast. As a result, the first monolithic visible-light OCT (vis-OCT) endomicroscope, with a submillimeter outer diameter (∼0.4 mm), is presented, achieving an ultrahigh resolution of 1.4 μm axial × 4.5 μm transverse in air. This compact probe allows minimally invasive in vivo deep-brain imaging in mice at a depth of 7.2 mm. Key regions in the mouse deep brain, such as the isocortex, corpus callosum, and caudate putamen, were successfully identified using our vis-OCT endomicroscope. In addition, we examined the myeloarchitectures and cytoarchitectures in the isocortex. Our findings demonstrate that the vis-OCT endomicroscope offers enhanced visualization of myelinated axon fibers and nerve fiber bundles compared to its 800 nm counterpart. This vis-OCT endomicroscope, overcoming resolution and imaging depth limitations of conventional methods, offers a novel tool for minimally invasive, ultrahigh-resolution in vivo deep brain neuroimaging.
- 1 November 2024
- Published by AIP Publishing in APL Photonics
- Vol. 9 (11)
Open AccessUltrathin visible-light OCT endomicroscopy for in vivo ultrahigh-resolution neuroimaging in deep brain
Deep-brain neuroimaging, a task that demands high-resolution imaging techniques for visualizing intricate brain structures, assessing deep-seated disease histopathology, and offering real-time intervention guidance, is challenged by the resolution-depth trade-off of current methods. We propose an optical coherence tomography (OCT) endomicroscopy device for high-resolution in vivo imaging of deep brain microstructures and histopathology. A unique liquid shaping technique enables the direct fabrication of a microlens on the fiber tip of the imaging probe, optimizing imaging performance parameters, such as longitudinal focal shift, focused spot size, and working distance. In addition, a broadband visible-light source enhances axial resolution and OCT imaging contrast. As a result, the first monolithic visible-light OCT (vis-OCT) endomicroscope, with a submillimeter outer diameter (∼0.4 mm), is presented, achieving an ultrahigh resolution of 1.4 μm axial × 4.5 μm transverse in air. This compact probe allows minimally invasive in vivo deep-brain imaging in mice at a depth of 7.2 mm. Key regions in the mouse deep brain, such as the isocortex, corpus callosum, and caudate putamen, were successfully identified using our vis-OCT endomicroscope. In addition, we examined the myeloarchitectures and cytoarchitectures in the isocortex. Our findings demonstrate that the vis-OCT endomicroscope offers enhanced visualization of myelinated axon fibers and nerve fiber bundles compared to its 800 nm counterpart. This vis-OCT endomicroscope, overcoming resolution and imaging depth limitations of conventional methods, offers a novel tool for minimally invasive, ultrahigh-resolution in vivo deep brain neuroimaging.
- Open Access
- 30 August 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (35) , eadp3145
PneumaOCT: Pneumatic optical coherence tomography endoscopy for targeted distortion-free imaging in tortuous and narrow internal lumens
The complex anatomy of internal luminal organs, like bronchioles, poses challenges for endoscopic optical coherence tomography (OCT). These challenges include limited steerability for targeted imaging and nonuniform rotation distortion (NURD) with proximal scanning. Using rotary micromotors for distal scanning could address NURD but raises concerns about electrical safety and costs. We present pneumaOCT, the first pneumatic OCT endoscope, comprising a steerable catheter with a soft pneumatic actuator and an imaging probe with a miniature pneumatic turbine. With a diameter of 2.8 mm, pneumaOCT allows for a bending angle of up to 237°, facilitating navigation through narrow turns. The pneumatic turbine enables adjustable imaging speeds from 51 to 446 revolutions per second. We demonstrate the pneumaOCT in vivo imaging of mouse esophagus and colon, as well as targeted and distortion-free imaging of peripheral bronchioles in a bronchial phantom and a porcine lung. This advancement substantially improves endoscopic OCT for navigational imaging in curved and narrow lumens.
- 30 August 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (35) , eadp3145
Open AccessPneumaOCT: Pneumatic optical coherence tomography endoscopy for targeted distortion-free imaging in tortuous and narrow internal lumens
The complex anatomy of internal luminal organs, like bronchioles, poses challenges for endoscopic optical coherence tomography (OCT). These challenges include limited steerability for targeted imaging and nonuniform rotation distortion (NURD) with proximal scanning. Using rotary micromotors for distal scanning could address NURD but raises concerns about electrical safety and costs. We present pneumaOCT, the first pneumatic OCT endoscope, comprising a steerable catheter with a soft pneumatic actuator and an imaging probe with a miniature pneumatic turbine. With a diameter of 2.8 mm, pneumaOCT allows for a bending angle of up to 237°, facilitating navigation through narrow turns. The pneumatic turbine enables adjustable imaging speeds from 51 to 446 revolutions per second. We demonstrate the pneumaOCT in vivo imaging of mouse esophagus and colon, as well as targeted and distortion-free imaging of peripheral bronchioles in a bronchial phantom and a porcine lung. This advancement substantially improves endoscopic OCT for navigational imaging in curved and narrow lumens.
- 21 May 2024
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 180
Single sensor tomographic particle image velocimetry using kaleidoscopic light field camera
- 21 May 2024
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 180
Single sensor tomographic particle image velocimetry using kaleidoscopic light field camera
- 28 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 6 (1) , 351-361
Toward the Smooth Mesh Climbing of a Miniature Robot Using Bioinspired Soft and Expandable Claws
Unlike most micro robots that struggle to navigate rugged and uneven terrain, beetles exhibit remarkable agility, traversing complex substrates with ease. This remarkable locomotion is attributed to their unique adaptations, including stiffness-variable tarsi and expandable hooks at the tip of their tarsi, which prevent slipping and ensure a secure grip on the surface. In this study, we found that beetles actively bent and expanded their claws regularly to crawl freely on mesh surfaces. Inspired by the crawling mechanism of the beetles, a micro cable-and-pully-driven mechanism was designed and demonstrated to be most effective among four several different climbing strategies. After that, an 8-cm miniature climbing robot was assembled, equipping artificial claws to open and bend in the same cyclic manner as natural beetles. The robot can climb freely with a controllable gait on the mesh surface, steep incline of the angle of 60∘, and even transition surface. To our best knowledge, this is the first micro-scale robot that can climb both the mesh surface and cliffy incline.
- 28 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 6 (1) , 351-361
Toward the Smooth Mesh Climbing of a Miniature Robot Using Bioinspired Soft and Expandable Claws
Unlike most micro robots that struggle to navigate rugged and uneven terrain, beetles exhibit remarkable agility, traversing complex substrates with ease. This remarkable locomotion is attributed to their unique adaptations, including stiffness-variable tarsi and expandable hooks at the tip of their tarsi, which prevent slipping and ensure a secure grip on the surface. In this study, we found that beetles actively bent and expanded their claws regularly to crawl freely on mesh surfaces. Inspired by the crawling mechanism of the beetles, a micro cable-and-pully-driven mechanism was designed and demonstrated to be most effective among four several different climbing strategies. After that, an 8-cm miniature climbing robot was assembled, equipping artificial claws to open and bend in the same cyclic manner as natural beetles. The robot can climb freely with a controllable gait on the mesh surface, steep incline of the angle of 60∘, and even transition surface. To our best knowledge, this is the first micro-scale robot that can climb both the mesh surface and cliffy incline.
- 3 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 38 (4) , 2208-2219
Launching of a Cyborg Locust via Co-Contraction Control of Hindleg Muscles
Jumping is beneficial for microrobots because they have to face obstacles larger than their height frequently. However, compacting a jumping mechanism into the small body of a microrobot is exceptionally challenging. Instead of assembling a bio-inspired microrobot, the insect itself can be transformed into a jumping robot. Herein, we demonstrated the first-ever biohybrid jumping robot that retained the natural jumping ability of a locust. The fast kicking of the locust's hindleg was mainly induced by two muscles, flexor muscle, and extensor muscle. The elaborate structure and accurate collaboration of the muscles are critical for leg kicking, contributing to the co-contraction process. In this article, we investigated the sequences of muscular activities and demonstrated the co-contraction control exogenously. The kicking control of the hindleg relies on the accurately overlapped stimulation and the independently modulated waveform. With the help of a tiny wireless stimulator, the cyborg locust was remotely controlled to jump an average of 10.4 cm high and 42.6 cm far. Moreover, the cyborg locust retained its internal body righting mechanism, which means the robot can quickly recover its posture for consecutive jumping. This work is a foundational step towards a fully controllable biohybrid jumping robot.
- 3 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 38 (4) , 2208-2219
Launching of a Cyborg Locust via Co-Contraction Control of Hindleg Muscles
Jumping is beneficial for microrobots because they have to face obstacles larger than their height frequently. However, compacting a jumping mechanism into the small body of a microrobot is exceptionally challenging. Instead of assembling a bio-inspired microrobot, the insect itself can be transformed into a jumping robot. Herein, we demonstrated the first-ever biohybrid jumping robot that retained the natural jumping ability of a locust. The fast kicking of the locust's hindleg was mainly induced by two muscles, flexor muscle, and extensor muscle. The elaborate structure and accurate collaboration of the muscles are critical for leg kicking, contributing to the co-contraction process. In this article, we investigated the sequences of muscular activities and demonstrated the co-contraction control exogenously. The kicking control of the hindleg relies on the accurately overlapped stimulation and the independently modulated waveform. With the help of a tiny wireless stimulator, the cyborg locust was remotely controlled to jump an average of 10.4 cm high and 42.6 cm far. Moreover, the cyborg locust retained its internal body righting mechanism, which means the robot can quickly recover its posture for consecutive jumping. This work is a foundational step towards a fully controllable biohybrid jumping robot.