István Bányász
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
István Bányász has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- István Rajta
Atomki, HUN-REN Institute for Nuclear Research, P.O. Box 51, H-4001 Debrecen, Hungary
5 shared publications - Vladimir Havranek
Nuclear Physics Institute AV CR, 250 68 Řež near Prague, Czech Republic
5 shared publications - Gyula Nagy
Institute of Applied Physics, TU Wien, 1040 Vienna, Austria
4 shared publications - Miklós Fried
Institute of Technical Physics and Materials Science, Centre for Energy Research, Konkoly-Thege Rd. 29-33, 1121 Budapest, Hungary
3 shared publications - Robert Magnusson
University of Texas at Arlington
3 shared publications - Maria Cinta Pujol
Departament Química Física i Inorgànica, Universitat Rovira i Virgili, Campus Sescelades, E-43007 Tarragona, Spain
2 shared publications
Latest Publications
- Open Access
Inscription of Quasi-Sinusoidal Surface Relief Optical Gratings in ZEONOR™ Cyclic Olefin Polymer by a 10.5 MeV N4+ Ion Microbeam at Low Implanted Fluences
Direct writing of microstructures in ZEONOR™ cyclic olefin polymer, using a high-energy medium-mass ion microbeam, was proposed and demonstrated. Microbeams of 10.5 MeV N4+ ions were used. The implanted fluences were between 2.5·1012 and 2.0·1013 ion/cm2. The microstructures were surface relief optical gratings of quasi-sinusoidal profile and grating constant of 4, 8 and 16 µm. Peak-to-peak amplitudes of the gratings ranged from 10 to 90 nm. Measured profiles of the gratings were Fourier-analyzed. Highest measured net first-order diffraction efficiencies were between 25 and 29% at wavelengths of 405 and 640 nm, very close to the theoretical maximum of 33%, calculated with the Raman-Nath equation. This method could be used for the production of micro- and nanostructures in cyclic olefin polymers and copolymers and other polymers as well, either for the direct production of label-free biosensors and other devices, or to produce masters for hot stamping of such structures.
Open AccessInscription of Quasi-Sinusoidal Surface Relief Optical Gratings in ZEONOR™ Cyclic Olefin Polymer by a 10.5 MeV N4+ Ion Microbeam at Low Implanted Fluences
Direct writing of microstructures in ZEONOR™ cyclic olefin polymer, using a high-energy medium-mass ion microbeam, was proposed and demonstrated. Microbeams of 10.5 MeV N4+ ions were used. The implanted fluences were between 2.5·1012 and 2.0·1013 ion/cm2. The microstructures were surface relief optical gratings of quasi-sinusoidal profile and grating constant of 4, 8 and 16 µm. Peak-to-peak amplitudes of the gratings ranged from 10 to 90 nm. Measured profiles of the gratings were Fourier-analyzed. Highest measured net first-order diffraction efficiencies were between 25 and 29% at wavelengths of 405 and 640 nm, very close to the theoretical maximum of 33%, calculated with the Raman-Nath equation. This method could be used for the production of micro- and nanostructures in cyclic olefin polymers and copolymers and other polymers as well, either for the direct production of label-free biosensors and other devices, or to produce masters for hot stamping of such structures.
- Open Access
Fourier Analysis of the Nonlinearity of Surface-Relief Optical Transmission Gratings of Quasi-Sinusoidal Profile Fabricated in Optical Glasses and Crystals by Carbon, Nitrogen and Oxygen Ion Microbeams
Optical transmission gratings with quasi-sinusoidal surface-relief profiles were inscribed in IOG and Pyrex glasses and in Bi12GeO20, Er: LiNbO3, and Er: Fe: LiNbO3 crystals by microbeams of carbon, nitrogen, and oxygen ions at ion energies of 5, 6, and 10.5 MeV. Grating constants were 4, 8, and 16 μm. Amplitudes of the surface-relief gratings were in the 10–2000 nm range. The diffraction efficiency of the gratings was measured at a wavelength of 640 nm. Maximum diffraction efficiencies were close to the theoretical maximum of 33% for thin gratings. Grating profiles were measured by optical microscopic profilometry. Measurement of the diffraction efficiencies at higher orders and Fourier analysis of the grating profiles revealed the dependence of the residual nonlinearity of the grating profiles on the implanted ion fluence. The ion microbeam-written gratings can be used as light coupling elements in integrated optics for sensors and telecommunication.
Open AccessFourier Analysis of the Nonlinearity of Surface-Relief Optical Transmission Gratings of Quasi-Sinusoidal Profile Fabricated in Optical Glasses and Crystals by Carbon, Nitrogen and Oxygen Ion Microbeams
Optical transmission gratings with quasi-sinusoidal surface-relief profiles were inscribed in IOG and Pyrex glasses and in Bi12GeO20, Er: LiNbO3, and Er: Fe: LiNbO3 crystals by microbeams of carbon, nitrogen, and oxygen ions at ion energies of 5, 6, and 10.5 MeV. Grating constants were 4, 8, and 16 μm. Amplitudes of the surface-relief gratings were in the 10–2000 nm range. The diffraction efficiency of the gratings was measured at a wavelength of 640 nm. Maximum diffraction efficiencies were close to the theoretical maximum of 33% for thin gratings. Grating profiles were measured by optical microscopic profilometry. Measurement of the diffraction efficiencies at higher orders and Fourier analysis of the grating profiles revealed the dependence of the residual nonlinearity of the grating profiles on the implanted ion fluence. The ion microbeam-written gratings can be used as light coupling elements in integrated optics for sensors and telecommunication.
- Open Access
- 30 April 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (9) , 4956
Ion-Implanted Diamond Blade Diced Ridge Waveguides in Pr:YLF—Optical Characterization and Small-Signal Gain Measurement
Planar optical waveguides were fabricated in Pr:YLF crystals by ion implantation. In a further step, ridge waveguides were fabricated using precision diamond dicing. These enable strong light confinement and have propagation losses as low as 0.4 dB/cm. To study the influence of ion implantation on the spectroscopic properties, fluorescence and lifetime measurements were conducted in the ridge waveguides. Under blue pumping, small-signal optical gains of 6.5 dB/cm and 5 dB/cm were demonstrated at wavelengths of 607 nm and 639 nm, respectively. These results make ion-implanted ridge waveguides in Pr:YLF promising candidates for compact integrated lasers in the visible spectral region with high output powers in the watt range.
- 30 April 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (9) , 4956
Open AccessIon-Implanted Diamond Blade Diced Ridge Waveguides in Pr:YLF—Optical Characterization and Small-Signal Gain Measurement
Planar optical waveguides were fabricated in Pr:YLF crystals by ion implantation. In a further step, ridge waveguides were fabricated using precision diamond dicing. These enable strong light confinement and have propagation losses as low as 0.4 dB/cm. To study the influence of ion implantation on the spectroscopic properties, fluorescence and lifetime measurements were conducted in the ridge waveguides. Under blue pumping, small-signal optical gains of 6.5 dB/cm and 5 dB/cm were demonstrated at wavelengths of 607 nm and 639 nm, respectively. These results make ion-implanted ridge waveguides in Pr:YLF promising candidates for compact integrated lasers in the visible spectral region with high output powers in the watt range.
- Open Access
Direct Writing of Quasi-Sinusoidal and Blazed Surface Relief Optical Transmission Gratings in Bi12GeO20, Er: LiNbO3 and Er: Fe: LiNbO3 Crystals by Nitrogen Ion Microbeams of 5 MeV and 10.5 MeV Energy
High diffraction efficiency optical transmission gratings with quasi-sinusoidal and saw-tooth surface relief profiles were fabricated in Bi12GeO20, Er: LiNbO3 and Er: Fe: LiNbO3 crystals by ion beam implantation. The gratings were directly written by nitrogen ion microbeams at energies of 5 MeV and 10.5 MeV. The finest grating constant was 4 μm. Grating constants for the majority of the gratings were 16 μm. The highest amplitudes of the gratings reached 1600 nm. The highest first-order diffraction efficiency obtained in a sinusoidal grating was 25%, close to the theoretical maximum of 33%. The highest first-order diffraction efficiency of a blazed grating was also 25%, without Littrow optimization. Such gratings can be incorporated into integrated optical biosensors.
Open AccessDirect Writing of Quasi-Sinusoidal and Blazed Surface Relief Optical Transmission Gratings in Bi12GeO20, Er: LiNbO3 and Er: Fe: LiNbO3 Crystals by Nitrogen Ion Microbeams of 5 MeV and 10.5 MeV Energy
High diffraction efficiency optical transmission gratings with quasi-sinusoidal and saw-tooth surface relief profiles were fabricated in Bi12GeO20, Er: LiNbO3 and Er: Fe: LiNbO3 crystals by ion beam implantation. The gratings were directly written by nitrogen ion microbeams at energies of 5 MeV and 10.5 MeV. The finest grating constant was 4 μm. Grating constants for the majority of the gratings were 16 μm. The highest amplitudes of the gratings reached 1600 nm. The highest first-order diffraction efficiency obtained in a sinusoidal grating was 25%, close to the theoretical maximum of 33%. The highest first-order diffraction efficiency of a blazed grating was also 25%, without Littrow optimization. Such gratings can be incorporated into integrated optical biosensors.
- Open Access
- 16 July 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 555
Fluence evolution of defects in α-SiO2 determined by ionoluminescence
- 16 July 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 555
Open AccessFluence evolution of defects in α-SiO2 determined by ionoluminescence
- Open Access
- 4 July 2024
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 9 (28) , 30415-30424
Fabrication of Quasi-Sinusoidal Surface Relief Optical Transmission Gratings in Pyrex and IOG Glasses by Implantation with Oxygen and Nitrogen Ion Microbeams of the 5–6 MeV Energy Range
A method for the fabrication of high diffraction efficiency optical transmission gratings with quasi-sinusoidal profile in glasses by microbeams of medium-mass ions of 5–6 MeV energy was devised and demonstrated. Gratings with a 30 μm grating constant have been manufactured and characterized by interference microscopy and microprofilometry. The obtained surface profiles of the gratings were found to be quasi-sinusoidal with up to 265 nm amplitude. Measured highest first-order diffraction efficiencies were around 26% in both Pyrex and IOG glasses. Such gratings could serve as coupling elements in integrated optics and photonic integrated circuits.
- 4 July 2024
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 9 (28) , 30415-30424
Open AccessFabrication of Quasi-Sinusoidal Surface Relief Optical Transmission Gratings in Pyrex and IOG Glasses by Implantation with Oxygen and Nitrogen Ion Microbeams of the 5–6 MeV Energy Range
A method for the fabrication of high diffraction efficiency optical transmission gratings with quasi-sinusoidal profile in glasses by microbeams of medium-mass ions of 5–6 MeV energy was devised and demonstrated. Gratings with a 30 μm grating constant have been manufactured and characterized by interference microscopy and microprofilometry. The obtained surface profiles of the gratings were found to be quasi-sinusoidal with up to 265 nm amplitude. Measured highest first-order diffraction efficiencies were around 26% in both Pyrex and IOG glasses. Such gratings could serve as coupling elements in integrated optics and photonic integrated circuits.
- Open Access
- 16 April 2024
- Published by Multidiszciplinaris tudomanyok in Multidiszciplináris tudományok
- Vol. 14 (1) , 94-106
Optikai hullámvezetők készítése ionimplantáció segítségével
Annak érdekében, hogy az optoelektronikai eszközöknél az optikai komponenseket miniatürizálni lehessen, újfajta módszereket kellett kifejleszteni azok gyártásához. Vannak azonban olyan anyagok, amelyeknek optikai tulajdonságai nagyon kedvezőek lennének, de a jelenlegi módszerekkel nem lehetséges azok használata, ugyanis fizikai vagy kémiai károsodást szenvednek a gyártási folyamat során. Az ilyen anyagoknál megfelelő alternatívát jelenthet az ionok implantációján alapuló módszer. A nagy energiájú ionokkal történő besugárzás ugyanis bizonyítottan megváltoztatja az anyag optikai és szerkezeti tulajdonságait. Ezzel lehetőség nyílik például optikai hullámvezetők létrehozására, ha egy előre meghatározott területét sugározzuk be a mintának. Ez történhet úgy, hogy egy előre elkészített speciális szili-konmaszk segítségével rajzoljuk ki a kívánt geometriát, vagy mikronyaláb használatával közvetlenül is beleírható a mintába a megfelelő alakzat. Ebben a cikkben az említett két módszerrel kapcsolatos legutóbbi eredményeket tekintjük át.
- 16 April 2024
- Published by Multidiszciplinaris tudomanyok in Multidiszciplináris tudományok
- Vol. 14 (1) , 94-106
Open AccessOptikai hullámvezetők készítése ionimplantáció segítségével
Annak érdekében, hogy az optoelektronikai eszközöknél az optikai komponenseket miniatürizálni lehessen, újfajta módszereket kellett kifejleszteni azok gyártásához. Vannak azonban olyan anyagok, amelyeknek optikai tulajdonságai nagyon kedvezőek lennének, de a jelenlegi módszerekkel nem lehetséges azok használata, ugyanis fizikai vagy kémiai károsodást szenvednek a gyártási folyamat során. Az ilyen anyagoknál megfelelő alternatívát jelenthet az ionok implantációján alapuló módszer. A nagy energiájú ionokkal történő besugárzás ugyanis bizonyítottan megváltoztatja az anyag optikai és szerkezeti tulajdonságait. Ezzel lehetőség nyílik például optikai hullámvezetők létrehozására, ha egy előre meghatározott területét sugározzuk be a mintának. Ez történhet úgy, hogy egy előre elkészített speciális szili-konmaszk segítségével rajzoljuk ki a kívánt geometriát, vagy mikronyaláb használatával közvetlenül is beleírható a mintába a megfelelő alakzat. Ebben a cikkben az említett két módszerrel kapcsolatos legutóbbi eredményeket tekintjük át.
- Open Access
- 31 July 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 123 (5)
Design, fabrication, and characterization of picowell arrays on cyclic olefin copolymer surfaces generated with a 10.5 MeV N4+ ion microbeam
Handling of picoliter-to-nanoliter-scale volumes and objects has increasing importance in life sciences. This is the volume scale of cell extractions and individual living cells. Here, we introduce a method of generating a picoliter-scale device by direct writing of picowell arrays on a ZEONOR™ copolymer surface with high-energy medium-mass ion microbeam. Arrays of various microstructures were written in the sample using a microbeam of 10.5 MeV N4+ ions at various implanted ion fluences. The best array was obtained by implantation of annuli of 10 and 11 μm of inner and outer diameters with a fluence of 7.8 × 1012 ions/cm2.
- 31 July 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 123 (5)
Open AccessDesign, fabrication, and characterization of picowell arrays on cyclic olefin copolymer surfaces generated with a 10.5 MeV N4+ ion microbeam
Handling of picoliter-to-nanoliter-scale volumes and objects has increasing importance in life sciences. This is the volume scale of cell extractions and individual living cells. Here, we introduce a method of generating a picoliter-scale device by direct writing of picowell arrays on a ZEONOR™ copolymer surface with high-energy medium-mass ion microbeam. Arrays of various microstructures were written in the sample using a microbeam of 10.5 MeV N4+ ions at various implanted ion fluences. The best array was obtained by implantation of annuli of 10 and 11 μm of inner and outer diameters with a fluence of 7.8 × 1012 ions/cm2.
- Open Access
- 17 August 2022
- Published by MDPI AG in Chemosensors
- Vol. 10 (8) , 337
Characterisation of Channel Waveguides Fabricated in an Er3+-Doped Tellurite Glass Using Two Ion Beam Techniques
Two methods were proposed and implemented for the fabrication of channel waveguides in an Er-doped Tellurite glass. In the first method, channel waveguides were fabricated by implanting 1.5 MeV and 3.5 MeV energy N+ ions through a special silicon mask to the glass sample at various fluences. Those waveguides implanted at a fluence of 1.0 × 1016 ions/cm2 operated up to 980 nm, and showed green upconversion of the Erbium ions. In the second method, channel waveguides were directly written in the Er3+: TeO2W2O3 glass using an 11 MeV C4+ ion microbeam with fluences in the range of 1 · 1014–5 · 1016 ions/cm2. The waveguides worked in single mode regime up to the 1540 nm telecom wavelength. Propagation losses were reduced from the 14 dB/cm of the as-irradiated waveguides by stepwise thermal annealing to 1.5 dB/cm at λ = 1400 nm.
- 17 August 2022
- Published by MDPI AG in Chemosensors
- Vol. 10 (8) , 337
Open AccessCharacterisation of Channel Waveguides Fabricated in an Er3+-Doped Tellurite Glass Using Two Ion Beam Techniques
Two methods were proposed and implemented for the fabrication of channel waveguides in an Er-doped Tellurite glass. In the first method, channel waveguides were fabricated by implanting 1.5 MeV and 3.5 MeV energy N+ ions through a special silicon mask to the glass sample at various fluences. Those waveguides implanted at a fluence of 1.0 × 1016 ions/cm2 operated up to 980 nm, and showed green upconversion of the Erbium ions. In the second method, channel waveguides were directly written in the Er3+: TeO2W2O3 glass using an 11 MeV C4+ ion microbeam with fluences in the range of 1 · 1014–5 · 1016 ions/cm2. The waveguides worked in single mode regime up to the 1540 nm telecom wavelength. Propagation losses were reduced from the 14 dB/cm of the as-irradiated waveguides by stepwise thermal annealing to 1.5 dB/cm at λ = 1400 nm.
- 26 November 2001
- Published by AIP Publishing in Applied Physics Letters
- Vol. 79 (23) , 3755-3757
Recording of transmission phase gratings in glass by ion implantation
Transmission phase gratings of grating constants of 4–12 μm have been designed and fabricated in glass via implantation of helium and nitrogen ions of energies in the 500 keV–1.6 MeV range, through photoresist masks of thickness of 3.3 μm. Multienergy implantations were applied, too. Phase profiles of the gratings were measured via interference and phase contrast microscopy and scanning electron microscopy. Quasisinusoidal profiles were obtained for the finest gratings. The highest first order diffraction efficiencies were around 20%. Dependence of the efficiencies of the gratings on the energy and dose of the implantation have been determined.
- 26 November 2001
- Published by AIP Publishing in Applied Physics Letters
- Vol. 79 (23) , 3755-3757
Recording of transmission phase gratings in glass by ion implantation
Transmission phase gratings of grating constants of 4–12 μm have been designed and fabricated in glass via implantation of helium and nitrogen ions of energies in the 500 keV–1.6 MeV range, through photoresist masks of thickness of 3.3 μm. Multienergy implantations were applied, too. Phase profiles of the gratings were measured via interference and phase contrast microscopy and scanning electron microscopy. Quasisinusoidal profiles were obtained for the finest gratings. The highest first order diffraction efficiencies were around 20%. Dependence of the efficiencies of the gratings on the energy and dose of the implantation have been determined.