Divya Parthasarathy Rao
Research Subjects
Divya Parthasarathy Rao has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
Anand Sivaraman
AI&ML, Remidio Innovative Solutions Pvt Ltd, Bengaluru, India
7 shared publicationsKalpa Negiloni
AI&ML, Remidio Innovative Solutions Pvt Ltd, Bengaluru, India
3 shared publicationsAdeeb Ulla Baig
R&D, Remidio Innovative Solutions Pvt Ltd, Bengaluru, India
2 shared publications- Anand Sivaraman
Research & Development, Remidio Innovative Solutions Pvt. Ltd., Bangalore, Karnataka, India
2 shared publications Chao-Kai Hsu
Medios Technologies Pte Ltd, Singapore, Singapore
2 shared publicationsFlorian M Savoy
AI&ML, Medios Technologies Pte Ltd, Remidio Innovative Solutions, Singapore
2 shared publications
Latest Publications
- Open Access
- 16 September 2024
- Published by Springer Nature in International Journal of Diabetes in Developing Countries
- Vol. 45  (3) , 736-738
Enhancing comprehensive diabetic care: A smartphone fundus camera with an offline AI-powered diabetic retinopathy screening solution for physicians
- 16 September 2024
- Published by Springer Nature in International Journal of Diabetes in Developing Countries
- Vol. 45  (3) , 736-738
Open AccessEnhancing comprehensive diabetic care: A smartphone fundus camera with an offline AI-powered diabetic retinopathy screening solution for physicians
- Open Access
Empowering Portable Age-Related Macular Degeneration Screening: Evaluation of a Deep Learning Algorithm for a Smartphone Fundus Camera
Objectives Despite global research on early detection of age-related macular degeneration (AMD), not enough is being done for large-scale screening. Automated analysis of retinal images captured via smartphone presents a potential solution; however, to our knowledge, such an artificial intelligence (AI) system has not been evaluated. The study aimed to assess the performance of an AI algorithm in detecting referable AMD on images captured on a portable fundus camera. Design, setting A retrospective image database from the Age-Related Eye Disease Study (AREDS) and target device was used. Participants The algorithm was trained on two distinct data sets with macula-centric images: initially on 108,251 images (55% referable AMD) from AREDS and then fine-tuned on 1108 images (33% referable AMD) captured on Asian eyes using the target device. The model was designed to indicate the presence of referable AMD (intermediate and advanced AMD). Following the first training step, the test set consisted of 909 images (49% referable AMD). For the fine-tuning step, the test set consisted of 238 (34% referable AMD) images. The reference standard for the AREDS data set was fundus image grading by the central reading centre, and for the target device, it was consensus image grading by specialists. Outcome measures Area under receiver operating curve (AUC), sensitivity and specificity of algorithm. Results Before fine-tuning, the deep learning (DL) algorithm exhibited a test set (from AREDS) sensitivity of 93.48% (95% CI: 90.8% to 95.6%), specificity of 82.33% (95% CI: 78.6% to 85.7%) and AUC of 0.965 (95% CI:0.95 to 0.98). After fine-tuning, the DL algorithm displayed a test set (from the target device) sensitivity of 91.25% (95% CI: 82.8% to 96.4%), specificity of 84.18% (95% CI: 77.5% to 89.5%) and AUC 0.947 (95% CI: 0.911 to 0.982). Conclusion The DL algorithm shows promising results in detecting referable AMD from a portable smartphone-based imaging system. This approach can potentially bring effective and affordable AMD screening to underserved areas.
Open AccessEmpowering Portable Age-Related Macular Degeneration Screening: Evaluation of a Deep Learning Algorithm for a Smartphone Fundus Camera
Objectives Despite global research on early detection of age-related macular degeneration (AMD), not enough is being done for large-scale screening. Automated analysis of retinal images captured via smartphone presents a potential solution; however, to our knowledge, such an artificial intelligence (AI) system has not been evaluated. The study aimed to assess the performance of an AI algorithm in detecting referable AMD on images captured on a portable fundus camera. Design, setting A retrospective image database from the Age-Related Eye Disease Study (AREDS) and target device was used. Participants The algorithm was trained on two distinct data sets with macula-centric images: initially on 108,251 images (55% referable AMD) from AREDS and then fine-tuned on 1108 images (33% referable AMD) captured on Asian eyes using the target device. The model was designed to indicate the presence of referable AMD (intermediate and advanced AMD). Following the first training step, the test set consisted of 909 images (49% referable AMD). For the fine-tuning step, the test set consisted of 238 (34% referable AMD) images. The reference standard for the AREDS data set was fundus image grading by the central reading centre, and for the target device, it was consensus image grading by specialists. Outcome measures Area under receiver operating curve (AUC), sensitivity and specificity of algorithm. Results Before fine-tuning, the deep learning (DL) algorithm exhibited a test set (from AREDS) sensitivity of 93.48% (95% CI: 90.8% to 95.6%), specificity of 82.33% (95% CI: 78.6% to 85.7%) and AUC of 0.965 (95% CI:0.95 to 0.98). After fine-tuning, the DL algorithm displayed a test set (from the target device) sensitivity of 91.25% (95% CI: 82.8% to 96.4%), specificity of 84.18% (95% CI: 77.5% to 89.5%) and AUC 0.947 (95% CI: 0.911 to 0.982). Conclusion The DL algorithm shows promising results in detecting referable AMD from a portable smartphone-based imaging system. This approach can potentially bring effective and affordable AMD screening to underserved areas.
- Open Access
- 29 July 2024
- Published by Wolters Kluwer Health in Indian Journal Of Ophthalmology
- Vol. 72  (8) , 1162-1167
Evaluation of an AI algorithm trained on an ethnically diverse dataset to screen a previously unseen population for diabetic retinopathy
Purpose: This study aimed to determine the generalizability of an artificial intelligence (AI) algorithm trained on an ethnically diverse dataset to screen for referable diabetic retinopathy (RDR) in the Armenian population unseen during AI development. Methods: This study comprised 550 patients with diabetes mellitus visiting the polyclinics of Armenia over 10 months requiring diabetic retinopathy (DR) screening. The Medios AI-DR algorithm was developed using a robust, diverse, ethnically balanced dataset with no inherent bias and deployed offline on a smartphone-based fundus camera. The algorithm here analyzed the retinal images captured using the target device for the presence of RDR (i.e., moderate non-proliferative diabetic retinopathy (NPDR) and/or clinically significant diabetic macular edema (CSDME) or more severe disease) and sight-threatening DR (STDR, i.e., severe NPDR and/or CSDME or more severe disease). The results compared the AI output to a consensus or majority image grading of three expert graders according to the International Clinical Diabetic Retinopathy severity scale. Results: On 478 subjects included in the analysis, the algorithm achieved a high classification sensitivity of 95.30% (95% CI: 91.9%–98.7%) and a specificity of 83.89% (95% CI: 79.9%–87.9%) for the detection of RDR. The sensitivity for STDR detection was 100%. Conclusion: The study proved that Medios AI-DR algorithm yields good accuracy in screening for RDR in the Armenian population. In our literature search, this is the only smartphone-based, offline AI model validated in different populations.
- 29 July 2024
- Published by Wolters Kluwer Health in Indian Journal Of Ophthalmology
- Vol. 72  (8) , 1162-1167
Open AccessEvaluation of an AI algorithm trained on an ethnically diverse dataset to screen a previously unseen population for diabetic retinopathy
Purpose: This study aimed to determine the generalizability of an artificial intelligence (AI) algorithm trained on an ethnically diverse dataset to screen for referable diabetic retinopathy (RDR) in the Armenian population unseen during AI development. Methods: This study comprised 550 patients with diabetes mellitus visiting the polyclinics of Armenia over 10 months requiring diabetic retinopathy (DR) screening. The Medios AI-DR algorithm was developed using a robust, diverse, ethnically balanced dataset with no inherent bias and deployed offline on a smartphone-based fundus camera. The algorithm here analyzed the retinal images captured using the target device for the presence of RDR (i.e., moderate non-proliferative diabetic retinopathy (NPDR) and/or clinically significant diabetic macular edema (CSDME) or more severe disease) and sight-threatening DR (STDR, i.e., severe NPDR and/or CSDME or more severe disease). The results compared the AI output to a consensus or majority image grading of three expert graders according to the International Clinical Diabetic Retinopathy severity scale. Results: On 478 subjects included in the analysis, the algorithm achieved a high classification sensitivity of 95.30% (95% CI: 91.9%–98.7%) and a specificity of 83.89% (95% CI: 79.9%–87.9%) for the detection of RDR. The sensitivity for STDR detection was 100%. Conclusion: The study proved that Medios AI-DR algorithm yields good accuracy in screening for RDR in the Armenian population. In our literature search, this is the only smartphone-based, offline AI model validated in different populations.
- Open Access
- 13 December 2023
- Published by Springer Nature in Eye
- Vol. 38  (6) , 1104-1111
Evaluation of an offline, artificial intelligence system for referable glaucoma screening using a smartphone-based fundus camera: a prospective study
Background/Objectives: An affordable and scalable screening model is critical for undetected glaucoma. The study evaluated the performance of an offline, smartphone-based AI system for the detection of referable glaucoma against two benchmarks: specialist diagnosis following full glaucoma workup and consensus image grading. Subjects/Methods: This prospective study (tertiary glaucoma centre, India) included 243 subjects with varying severity of glaucoma and control group without glaucoma. Disc-centred images were captured using a validated smartphone-based fundus camera analysed by the AI system and graded by specialists. Diagnostic ability of the AI in detecting referable Glaucoma (Confirmed glaucoma) and no referable Glaucoma (Suspects and No glaucoma) when compared to a final diagnosis (comprehensive glaucoma workup) and majority grading (image grading) by Glaucoma specialists (pre-defined criteria) were evaluated. Results: The AI system demonstrated a sensitivity and specificity of 93.7% (95% CI: 87.6–96.9%) and 85.6% (95% CI:78.6–90.6%), respectively, in the detection of referable glaucoma when compared against final diagnosis following full glaucoma workup. True negative rate in definite non-glaucoma cases was 94.7% (95% CI: 87.2–97.9%). Amongst the false negatives were 4 early and 3 moderate glaucoma. When the same set of images provided to the AI was also provided to the specialists for image grading, specialists detected 60% (67/111) of true glaucoma cases versus a detection rate of 94% (104/111) by the AI. Conclusion: The AI tool showed robust performance when compared against a stringent benchmark. It had modest over-referral of normal subjects despite being challenged with fundus images alone. The next step involves a population-level assessment.
- 13 December 2023
- Published by Springer Nature in Eye
- Vol. 38  (6) , 1104-1111
Open AccessEvaluation of an offline, artificial intelligence system for referable glaucoma screening using a smartphone-based fundus camera: a prospective study
Background/Objectives: An affordable and scalable screening model is critical for undetected glaucoma. The study evaluated the performance of an offline, smartphone-based AI system for the detection of referable glaucoma against two benchmarks: specialist diagnosis following full glaucoma workup and consensus image grading. Subjects/Methods: This prospective study (tertiary glaucoma centre, India) included 243 subjects with varying severity of glaucoma and control group without glaucoma. Disc-centred images were captured using a validated smartphone-based fundus camera analysed by the AI system and graded by specialists. Diagnostic ability of the AI in detecting referable Glaucoma (Confirmed glaucoma) and no referable Glaucoma (Suspects and No glaucoma) when compared to a final diagnosis (comprehensive glaucoma workup) and majority grading (image grading) by Glaucoma specialists (pre-defined criteria) were evaluated. Results: The AI system demonstrated a sensitivity and specificity of 93.7% (95% CI: 87.6–96.9%) and 85.6% (95% CI:78.6–90.6%), respectively, in the detection of referable glaucoma when compared against final diagnosis following full glaucoma workup. True negative rate in definite non-glaucoma cases was 94.7% (95% CI: 87.2–97.9%). Amongst the false negatives were 4 early and 3 moderate glaucoma. When the same set of images provided to the AI was also provided to the specialists for image grading, specialists detected 60% (67/111) of true glaucoma cases versus a detection rate of 94% (104/111) by the AI. Conclusion: The AI tool showed robust performance when compared against a stringent benchmark. It had modest over-referral of normal subjects despite being challenged with fundus images alone. The next step involves a population-level assessment.
- Open Access
- 27 September 2023
- Published by S. Karger AG in Ophthalmic Research
- Vol. 66  (1) , 1286-1292
Diagnostic Accuracy of Automated Diabetic Retinopathy Image Assessment Softwares: IDx-DR and Medios Artificial Intelligence
Introduction: Numerous studies have demonstrated the use of artificial intelligence (AI) for early detection of referable diabetic retinopathy (RDR). A direct comparison of these multiple automated diabetic retinopathy (DR) image assessment softwares (ARIAs) is, however, challenging. We retrospectively compared the performance of two modern ARIAs, IDx-DR and Medios AI. Methods: In this retrospective-comparative study, retinal images with sufficient image quality were run on both ARIAs. They were captured in 811 consecutive patients with diabetes visiting diabetic clinics in Poland. For each patient, four non-mydriatic images, 45° field of view, i.e., two sets of one optic disc and one macula-centered image using Topcon NW400 were captured. Images were manually graded for severity of DR as no DR, any DR (mild non-proliferative diabetic retinopathy [NPDR] or more severe disease), RDR (moderate NPDR or more severe disease and/or clinically significant diabetic macular edema [CSDME]), or sight-threatening DR (severe NPDR or more severe disease and/or CSDME) by certified graders. The ARIA output was compared to manual consensus image grading (reference standard). Results: On 807 patients, based on consensus grading, there was no evidence of DR in 543 patients (67%). Any DR was seen in 264 (33%) patients, of which 174 (22%) were RDR and 41 (5%) were sight-threatening DR. The sensitivity of detecting RDR against reference standard grading was 95% (95% CI: 91, 98%) and the specificity was 80% (95% CI: 77, 83%) for Medios AI. They were 99% (95% CI: 96, 100%) and 68% (95% CI: 64, 72%) for IDx-DR, respectively. Conclusion: Both the ARIAs achieved satisfactory accuracy, with few false negatives. Although false-positive results generate additional costs and workload, missed cases raise the most concern whenever automated screening is debated.
- 27 September 2023
- Published by S. Karger AG in Ophthalmic Research
- Vol. 66  (1) , 1286-1292
Open AccessDiagnostic Accuracy of Automated Diabetic Retinopathy Image Assessment Softwares: IDx-DR and Medios Artificial Intelligence
Introduction: Numerous studies have demonstrated the use of artificial intelligence (AI) for early detection of referable diabetic retinopathy (RDR). A direct comparison of these multiple automated diabetic retinopathy (DR) image assessment softwares (ARIAs) is, however, challenging. We retrospectively compared the performance of two modern ARIAs, IDx-DR and Medios AI. Methods: In this retrospective-comparative study, retinal images with sufficient image quality were run on both ARIAs. They were captured in 811 consecutive patients with diabetes visiting diabetic clinics in Poland. For each patient, four non-mydriatic images, 45° field of view, i.e., two sets of one optic disc and one macula-centered image using Topcon NW400 were captured. Images were manually graded for severity of DR as no DR, any DR (mild non-proliferative diabetic retinopathy [NPDR] or more severe disease), RDR (moderate NPDR or more severe disease and/or clinically significant diabetic macular edema [CSDME]), or sight-threatening DR (severe NPDR or more severe disease and/or CSDME) by certified graders. The ARIA output was compared to manual consensus image grading (reference standard). Results: On 807 patients, based on consensus grading, there was no evidence of DR in 543 patients (67%). Any DR was seen in 264 (33%) patients, of which 174 (22%) were RDR and 41 (5%) were sight-threatening DR. The sensitivity of detecting RDR against reference standard grading was 95% (95% CI: 91, 98%) and the specificity was 80% (95% CI: 77, 83%) for Medios AI. They were 99% (95% CI: 96, 100%) and 68% (95% CI: 64, 72%) for IDx-DR, respectively. Conclusion: Both the ARIAs achieved satisfactory accuracy, with few false negatives. Although false-positive results generate additional costs and workload, missed cases raise the most concern whenever automated screening is debated.
- Open Access
- 22 December 2022
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 16, 4281-4291
Validation of a Simple-to-Use, Affordable, Portable Wavefront Aberrometry-Based Auto Refractometer in a Paediatric Population
Purpose: InstaRef R20 is a handheld, affordable auto refractometer based on Shack Hartmann aberrometry technology. The study’s objective was to compare InstaRef R20’s performance for identifying refractive error in a paediatric population to that of standard subjective and objective refraction under both pre- and post-cycloplegic conditions. Methods: Refraction was performed using 1) standard clinical procedure consisting of retinoscopy followed by subjective refraction (SR) under pre- and post-cycloplegic conditions and 2) InstaRef R20. Agreement between both methods was evaluated using Bland-Altman analysis. The repeatability of the device based on three measurements in a subgroup of 20 children was assessed. Results: The refractive error was measured in 132 children (mean age 12.31 ± 3 years). The spherical equivalent (M) and cylindrical components (J0 and J45) of the device had clinically acceptable differences (within ± 0.50D) and acceptable agreement compared to standard pre- and post-cycloplegic manual retinoscopy and subjective refraction (SR). The device agreed within ± 0.50D of retinoscopy in 67% of eyes for M, 78% for J0 and 80% for J45 and within ± 0.50D of SR in 70% for M and 77% for cylindrical components. Conclusion: InstaRef R20 has an acceptable agreement compared to standard retinoscopy in paediatric population. The measurements from this device can be used as a starting point for subjective acceptance. The device being simple to use, portable, reliable and affordable has the potential for large-scale community-based refractive error detection.
- 22 December 2022
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 16, 4281-4291
Open AccessValidation of a Simple-to-Use, Affordable, Portable Wavefront Aberrometry-Based Auto Refractometer in a Paediatric Population
Purpose: InstaRef R20 is a handheld, affordable auto refractometer based on Shack Hartmann aberrometry technology. The study’s objective was to compare InstaRef R20’s performance for identifying refractive error in a paediatric population to that of standard subjective and objective refraction under both pre- and post-cycloplegic conditions. Methods: Refraction was performed using 1) standard clinical procedure consisting of retinoscopy followed by subjective refraction (SR) under pre- and post-cycloplegic conditions and 2) InstaRef R20. Agreement between both methods was evaluated using Bland-Altman analysis. The repeatability of the device based on three measurements in a subgroup of 20 children was assessed. Results: The refractive error was measured in 132 children (mean age 12.31 ± 3 years). The spherical equivalent (M) and cylindrical components (J0 and J45) of the device had clinically acceptable differences (within ± 0.50D) and acceptable agreement compared to standard pre- and post-cycloplegic manual retinoscopy and subjective refraction (SR). The device agreed within ± 0.50D of retinoscopy in 67% of eyes for M, 78% for J0 and 80% for J45 and within ± 0.50D of SR in 70% for M and 77% for cylindrical components. Conclusion: InstaRef R20 has an acceptable agreement compared to standard retinoscopy in paediatric population. The measurements from this device can be used as a starting point for subjective acceptance. The device being simple to use, portable, reliable and affordable has the potential for large-scale community-based refractive error detection.
- Open Access
- 19 December 2022
- Published by Springer Nature in BMC Ophthalmology
- Vol. 22  (1) , 1-8
Validation of a simple-to-use, affordable, portable, wavefront aberrometry-based auto refractometer in the adult population: A prospective study
Refraction is one of the key components of a comprehensive eye examination. Auto refractometers that are reliable and affordable can be beneficial, especially in a low-resource community setting. The study aimed to validate the accuracy of a novel wave-front aberrometry-based auto refractometer, Instaref R20 against the open-field system and subjective refraction in an adult population. All the participants underwent a comprehensive eye examination including objective refraction, subjective acceptance, anterior and posterior segment evaluation. Refraction was performed without cycloplegia using WAM5500 open-field auto refractometer (OFAR) and Instaref R20, the study device. Agreement between both methods was evaluated using Bland-Altman analysis. The repeatability of the device based on three measurements in a subgroup of 40 adults was assessed. The refractive error was measured in 132 participants (mean age,30.53 ± 9.36 years, 58.3% female). The paired mean difference of the refraction values of the study device against OFAR was − 0.13D for M, − 0.0002D (J0) and − 0.13D (J45) and against subjective refraction (SR) was − 0.09D (M), 0.06 (J0) and 0.03D (J45). The device agreed within +/− 0.50D of OFAR in 78% of eyes for M, 79% for J0 and 78% for J45. The device agreed within +/− 0.5D of SR values for M (84%), J0 (86%) and J45 (89%). This study found a good agreement between the measurements obtained with the portable autorefractor against open-field refractometer and SR values. It has a potential application in population-based community vision screening programs for refractive error correction without the need for highly trained personnel.
- 19 December 2022
- Published by Springer Nature in BMC Ophthalmology
- Vol. 22  (1) , 1-8
Open AccessValidation of a simple-to-use, affordable, portable, wavefront aberrometry-based auto refractometer in the adult population: A prospective study
Refraction is one of the key components of a comprehensive eye examination. Auto refractometers that are reliable and affordable can be beneficial, especially in a low-resource community setting. The study aimed to validate the accuracy of a novel wave-front aberrometry-based auto refractometer, Instaref R20 against the open-field system and subjective refraction in an adult population. All the participants underwent a comprehensive eye examination including objective refraction, subjective acceptance, anterior and posterior segment evaluation. Refraction was performed without cycloplegia using WAM5500 open-field auto refractometer (OFAR) and Instaref R20, the study device. Agreement between both methods was evaluated using Bland-Altman analysis. The repeatability of the device based on three measurements in a subgroup of 40 adults was assessed. The refractive error was measured in 132 participants (mean age,30.53 ± 9.36 years, 58.3% female). The paired mean difference of the refraction values of the study device against OFAR was − 0.13D for M, − 0.0002D (J0) and − 0.13D (J45) and against subjective refraction (SR) was − 0.09D (M), 0.06 (J0) and 0.03D (J45). The device agreed within +/− 0.50D of OFAR in 78% of eyes for M, 79% for J0 and 78% for J45. The device agreed within +/− 0.5D of SR values for M (84%), J0 (86%) and J45 (89%). This study found a good agreement between the measurements obtained with the portable autorefractor against open-field refractometer and SR values. It has a potential application in population-based community vision screening programs for refractive error correction without the need for highly trained personnel.
- 28 November 2022
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 32  (4) , 280-286
Agreement of a Novel Artificial Intelligence Software With Optical Coherence Tomography and Manual Grading of the Optic Disc in Glaucoma
Précis: The offline AI on a smartphone-based fundus camera shows good agreement and correlation with the vCDR from the SD-OCT and manual grading by experts. Purpose: To assess the agreement of vertical cup-to-disc ratio (vCDR) measured by a new artificial intelligence (AI) software from optic disc images obtained using a validated smartphone-based imaging device, with spectral-domain optical coherence tomography (SD-OCT) vCDR measurements, and manual grading by experts on a stereoscopic fundus camera. Methods: In a prospective, cross-sectional study, participants >18 years (Glaucoma and normal) underwent a dilated fundus evaluation followed by optic disc imaging including a 42o monoscopic disc-centered image (Remidio NM FOP-10), a 30o stereoscopic disc-centered image (Kowa nonmyd WX-3D desktop fundus camera), and disc analysis (Cirrus SD-OCT). Remidio FOP images were analysed for vCDR using the new AI software and Kowa stereoscopic images were manually graded by three fellowship-trained glaucoma specialists. Results: We included 473 eyes of 244 participants. The vCDR values from the new AI software showed strong agreement with SD-OCT measurements (95% limits of agreement (LoA)=−0.13 to 0.16). The agreement with SD-OCT was marginally better in eyes with higher vCDR (95% LoA=−0.15 to 0.12 for vCDR>0.8). Interclass correlation coefficient (ICC) was 0.90 (95% CI:0.88–0.91). The vCDR values from AI software showed a good correlation with the manual segmentation by experts (ICC=0.89, 95%CI:0.87–0.91) on stereoscopic images (95% LoA=−0.18 to 0.11) with agreement better for eyes with vCDR>0.8 (LoA=−0.12 to 0.08). Conclusion: The new AI software vCDR measurements had an excellent agreement and correlation with the SD-OCT and manual grading. The ability of the Medios AI to work offline, without requiring cloud-based inferencing, is an added advantage.
- 28 November 2022
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 32  (4) , 280-286
Agreement of a Novel Artificial Intelligence Software With Optical Coherence Tomography and Manual Grading of the Optic Disc in Glaucoma
Précis: The offline AI on a smartphone-based fundus camera shows good agreement and correlation with the vCDR from the SD-OCT and manual grading by experts. Purpose: To assess the agreement of vertical cup-to-disc ratio (vCDR) measured by a new artificial intelligence (AI) software from optic disc images obtained using a validated smartphone-based imaging device, with spectral-domain optical coherence tomography (SD-OCT) vCDR measurements, and manual grading by experts on a stereoscopic fundus camera. Methods: In a prospective, cross-sectional study, participants >18 years (Glaucoma and normal) underwent a dilated fundus evaluation followed by optic disc imaging including a 42o monoscopic disc-centered image (Remidio NM FOP-10), a 30o stereoscopic disc-centered image (Kowa nonmyd WX-3D desktop fundus camera), and disc analysis (Cirrus SD-OCT). Remidio FOP images were analysed for vCDR using the new AI software and Kowa stereoscopic images were manually graded by three fellowship-trained glaucoma specialists. Results: We included 473 eyes of 244 participants. The vCDR values from the new AI software showed strong agreement with SD-OCT measurements (95% limits of agreement (LoA)=−0.13 to 0.16). The agreement with SD-OCT was marginally better in eyes with higher vCDR (95% LoA=−0.15 to 0.12 for vCDR>0.8). Interclass correlation coefficient (ICC) was 0.90 (95% CI:0.88–0.91). The vCDR values from AI software showed a good correlation with the manual segmentation by experts (ICC=0.89, 95%CI:0.87–0.91) on stereoscopic images (95% LoA=−0.18 to 0.11) with agreement better for eyes with vCDR>0.8 (LoA=−0.12 to 0.08). Conclusion: The new AI software vCDR measurements had an excellent agreement and correlation with the SD-OCT and manual grading. The ability of the Medios AI to work offline, without requiring cloud-based inferencing, is an added advantage.
- Open Access
- 16 August 2022
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. 16, 2659-2667
Towards a Device Agnostic AI for Diabetic Retinopathy Screening: An External Validation Study
Purpose: To evaluate the performance of a validated Artificial Intelligence (AI) algorithm developed for a smartphone-based camera on images captured using a standard desktop fundus camera to screen for diabetic retinopathy (DR).Participants: Subjects with established diabetes mellitus.Methods: Images captured on a desktop fundus camera (Topcon TRC-50DX, Japan) for a previous study with 135 consecutive patients (233 eyes) with established diabetes mellitus, with or without DR were analysed by the AI algorithm. The performance of the AI algorithm to detect any DR, referable DR (RDR Ie, worse than mild non proliferative diabetic retinopathy (NPDR) and/or diabetic macular edema (DME)) and sight-threatening DR (STDR Ie, severe NPDR or worse and/or DME) were assessed based on comparisons against both image-based consensus grades by two fellowship trained vitreo-retina specialists and clinical examination.Results: The sensitivity was 98.3% (95% CI 96%, 100%) and the specificity 83.7% (95% CI 73%, 94%) for RDR against image grading. The specificity for RDR decreased to 65.2% (95% CI 53.7%, 76.6%) and the sensitivity marginally increased to 100% (95% CI 100%, 100%) when compared against clinical examination. The sensitivity for detection of any DR when compared against imagebased consensus grading and clinical exam were both 97.6% (95% CI 95%, 100%). The specificity for any DR detection was 90.9% (95% CI 82.3%, 99.4%) as compared against image grading and 88.9% (95% CI 79.7%, 98.1%) on clinical exam. The sensitivity for STDR was 99.0% (95% CI 96%, 100%) against image grading and 100% (95% CI 100%, 100%) as compared against clinical exam.Conclusion: The AI algorithm could screen for RDR and any DR with robust performance on images captured on a desktop fundus camera when compared to image grading, despite being previously optimized for a smartphone-based camera.
- 16 August 2022
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. 16, 2659-2667
Open AccessTowards a Device Agnostic AI for Diabetic Retinopathy Screening: An External Validation Study
Purpose: To evaluate the performance of a validated Artificial Intelligence (AI) algorithm developed for a smartphone-based camera on images captured using a standard desktop fundus camera to screen for diabetic retinopathy (DR).Participants: Subjects with established diabetes mellitus.Methods: Images captured on a desktop fundus camera (Topcon TRC-50DX, Japan) for a previous study with 135 consecutive patients (233 eyes) with established diabetes mellitus, with or without DR were analysed by the AI algorithm. The performance of the AI algorithm to detect any DR, referable DR (RDR Ie, worse than mild non proliferative diabetic retinopathy (NPDR) and/or diabetic macular edema (DME)) and sight-threatening DR (STDR Ie, severe NPDR or worse and/or DME) were assessed based on comparisons against both image-based consensus grades by two fellowship trained vitreo-retina specialists and clinical examination.Results: The sensitivity was 98.3% (95% CI 96%, 100%) and the specificity 83.7% (95% CI 73%, 94%) for RDR against image grading. The specificity for RDR decreased to 65.2% (95% CI 53.7%, 76.6%) and the sensitivity marginally increased to 100% (95% CI 100%, 100%) when compared against clinical examination. The sensitivity for detection of any DR when compared against imagebased consensus grading and clinical exam were both 97.6% (95% CI 95%, 100%). The specificity for any DR detection was 90.9% (95% CI 82.3%, 99.4%) as compared against image grading and 88.9% (95% CI 79.7%, 98.1%) on clinical exam. The sensitivity for STDR was 99.0% (95% CI 96%, 100%) against image grading and 100% (95% CI 100%, 100%) as compared against clinical exam.Conclusion: The AI algorithm could screen for RDR and any DR with robust performance on images captured on a desktop fundus camera when compared to image grading, despite being previously optimized for a smartphone-based camera.