QZQi Zhang

Qi Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Qi Zhang has a total of 37 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • U-Shaped Fiber Based-Long Range Surface Plasmon Resonance Sensor for Sensitive Hg 2+ Detection

    by Rao Fu, Xiaobing Chen, Huina Tang, Yuhan Qu, Zhiyuan Yin, Qi Zhang, Tonglei Cheng, Xue Zhou, Xin Yan

    An U-shaped fiber long range surface plasmon resonance (LRSPR) sensor is proposed to detect trace Hg2+ in water system. The U-shaped fiber is bend and coated with 100 nm MgF2 and 50 nm Au film, the U-shaped fiber LRSPR senor could combine the advantage of high sensitivity and low full width of half maximum (FWHM) by the optimization of the fiber bending radius (BRs) and MgF2 thickness. With the functionalization of single-stranded DNA (ssDNA) on the Au layer by covalent bond, the Hg2+ could be selectively detected by the thymine (T) base pairs, which would form stable T-Hg-T structure by the folding of ssDNA and cause the change in surface refractive index (RI). The detection range of Hg2+ is 50 nM–5 mM, and the limit of detection (LOD) reaches at 60 nM. The selectivity and stability are proved to be good and the recovery from the spiked tap water is also tested. The good performance and wide range of the proposed sensor indicates high potential for future Hg2+ sensor development and multiple using scenarios.


  • High-sensitivity Mach–Zehnder interferometer temperature sensor based on a no-core optical fiber with a large lateral offset

    by Xinghui Li, Huifang Wang, Xiaopeng Chen, Qi Zhang, Xiaoyu Chen, Xue Zhou, Xin Yan, Yong Zhao, Tonglei Cheng

    We designed and experimentally demonstrated an innovative temperature sensor based on Mach–Zehnder interference, which was formed by splicing a piece of no-core fiber (NCF) between two conventional single-mode fibers (SMFs) with a core offset. The intentional misalignment formed a gap that can be filled with ethanol, and temperature sensing was realized using the mode interference between the two distinct optical paths passing through the NCF cladding and the ethanol solution. Although the NCF length barely influenced the sensor sensitivity, it produced a major impact on the free spectral range (FSR) value. As a result, simulations were conducted and an NCF length of 620.7 µm was prepared. The sensor achieved a remarkable temperature sensitivity of 5.3574 nm/°C within the 30–36 °C range. Furthermore, the sensor boasted multiple advantages, including compact structure, high repeatability, and exceptional stability, rendering it a highly effective and versatile tool for precise thermal measurement in cell culture.


  • ZnS:Cu-Based Fluorescence and Surface Plasmon Resonance Triple Channel Sensor for Simultaneous Detection of Ultraviolet Intensity, Humidity, and Temperature

    by Rao Fu, Xiaobing Chen, Haihui Li, Huina Tang, Yuhan Qu, Zhiyuan Yin, Qi Zhang, Tonglei Cheng, Xue Zhou, Xin Yan

    With the increasing demand for more powerful sensors, rapid development had been achieved. In this paper, a fluorescence(FL) and surface plasmon resonance(SPR) triple channel sensor was designed based on wavelength division multiplexing(WDM). First, ZnS:Cu powder was mixed inside polydimethylsiloxane(PDMS) to detect ultraviolet intensity(UVI) and temperature as channel 1. Second, we coated the thin core fiber(TCF) with 40 nm Ag film and carboxymethyl cellulose (CMC) to detect relative humidity(RH) as channel 2. Third, another part of TCF was coated with 40 nm Ag, 4 nm ZnO film and PDMS also to detect UVI and temperature as channel 3. The detection range and compensation accuracy of UVI, RH and T are 3.74-26.18 mW/cm2, 1.016; 20%-100% RH, 1.022 and 5-41 °C, 1.017. All the channels could be compensated to isolate single variation during simultaneous change. Compared with previous work, the first introduction of fluorescence signal into SPR sensor in this paper achieves three channels integration inside one single fiber structure, and all three parameters could be monitored simultaneously. The advantages of proposed sensor such as high accuracy, stability and multi-parameter simultaneous sensing could be quite useful in future environmental monitoring field.

  • An Er³+/Yb³+ Co-Doped Tellurite Fiber Temperature Sensor for Real-Time Thermal Monitoring for Lithium Battery

    by Huifang Wang, Ning Yang, Xinghui Li, Xiaopeng Chen, Xiaoyu Chen, Qi Zhang, Zhiyuan Yin, Xue Zhou, Xin Yan, Tonglei Cheng

    We propose and experimentally demonstrate a non-contact optical thermometric study based on Fluorescence Intensity Ratio (FIR) of non-thermally coupled levels (NTCLs) for real-time temperature detection of lithium battery. The no-core Er 3+ /Yb 3+ co-doped TeO 2 -Al 2 O 3 -WO 3 -BaF 2 +Er 2 O 3 +Yb 2 O 3 (TWA) optical fiber was prepared using the traditional melt-quenching method, and influence of the Al 2 O 3 concentration on the fiber luminescence was investigated in detail. Meanwhile, temperature demodulation by means of thermally coupled level (TCLs)-based FIR was juxtaposed for comparison. It was found that the sensor’s sensitivity was enhanced at least 10 times utilizing the NTCLs-based FIR method, and at Al 2 O 3 concentration of 4 mol%, the sensor demonstrated the best sensing performance, which was 434.3×10 -4 K -1 in the temperature range of 258 to 371 K. In addition, this sensor had high temperature resolution and good repeatability, and its maximum measurement error during thermal monitoring of the charging/discharging process of an 18650-type lithium battery was only 0.7 K. To the best of our knowledge, this was the first report to use a temperature sensor based on fluorescence intensity ratio for real-time monitoring of 18650-type lithium batteries. The proposed sensor demonstrated excellent stability and repeatability, resistance to electromagnetic interference and corrosion, and the capability to avoid cross-sensitivity. It provides an effective and reliable measurement solution for long-distance and real-time temperature monitoring in new energy battery applications.


  • Temperature Detection Based on Surface Plasmon Resonance Sensor for Microwave Ablation

    by Qi Zhang, Taotao Hu, Hailian Liu, Sanzhar Korganbayev, Paola Saccomandi, Xue Zhou, Xin Yan, Xuenan Zhang, Tonglei Cheng

    Microwave ablation is a minimally invasive technique using microwave energy to heat and destroy abnormal cells in tumors, in which temperature monitoring is critical to achieve the desired thermal therapy effect while protecting surrounding healthy tissue. This paper proposes for the first time using a surface plasmon resonance (SPR) -based temperature sensor for the real - time monitoring of tissue temperature changes during microwave ablation. The SPR sensor has the advantages of simple structure, low cost, large measurement range and satisfactory sensitivity. The SPR sensor adopted a multi-mode fiber (MMF) -thin-core fiber (TCF) -MMF structure, yielding a sensitivity of -1.781 ± 0.031 nm/°C in the range 22-94 °C. Furthermore, a commercially available fiber Bragg grating (FBG) array sensor was used as a reference, confirming the effectiveness of the proposed SPR sensor in the application.


  • UV-Protective and Flexible Electrospun Nanofiber-Based Pressure Sensor for Outdoor Activity Monitoring

    by Hailian Liu, Ning Yang, Qi Zhang, Xin Yan, Xuenan Zhang, Xue Zhou, Yong Zhao, Tonglei Cheng

    The development of flexible pressure sensors with (ultraviolet) UV shielding property is of great significance for outdoor activity monitoring devices. In this work, we propose a flexible pressure sensor based on polyacrylonitrile (PAN)/TiO 2 /MXene nanofiber membrane by combining the electrospinning and dip-coating methods, and the addition of TiO 2 nanoparticles and MXene flakes greatly improves the UV-protective performance of the sensor. The high ultraviolet protection factor (UPF) of the proposed sensor is ~24716, and it has a relatively stable transmittance for UV light of different power. This UV-protective sensor not only shows excellent pressure sensitivity (0.15148 kPa -1 ) in a wide range of 350 kPa but also has excellent breathability as well as good cycle stability. The results show that the PAN/TiO 2 /MXene sensor has excellent UV protection performance and pressure sensing ability, which can be used for outdoor activity monitoring. It can monitor various sports conditions when people are outdoors, demonstrating broad application prospects in fields such as intelligent sports and wearable electronics.


  • High Sensitivity Surface Plasmon Resonance Magnetic Field Sensor Based on Au/Gold Nanoparticles/Magnetic Fluid in the Hollow Core Fiber

    by Qi Zhang, Hailian Liu, Rao Fu, Bin Li, Xin Yan, Xuenan Zhang, Fang Wang, Tonglei Cheng

    A type of surface plasmon resonance (SPR) magnetic field sensor based on Au/gold nanoparticles/magnetic fluid (MF)-processed hollow core fiber is proposed in this work, which fully utilizes SPR’s high sensitivity to RI and the magnetron refractive index characteristic of MF. The metal material Au excites SPR and gold nanoparticles excite the localized surface plasmon resonance (LSPR). The coupling of surface plasmon polariton (SPP) with localized surface plasmon (LSP) increases the local electric field strength, thus improving the sensor’s sensitivity. Both the theoretical analysis on the sensing mechanism and the experimental findings demonstrate that this novel SPR magnetic field sensor has a wide measurement range and high sensitivity. In the range of magnetic field strength from 0 to 603 Gs, the sensitivity can reach up to 156 pm/Gs, and the linearity is good (the coefficient of determination is 0.996). Compared with other optical fiber magnetic field sensors, the sensor proposed in this paper has the benefits of easy fabrication, excellent sensitivity, simple structure, strong anti-interference ability, and wide measurement range, exhibiting significant application potentials in the fields of military drills, aerospace, etc.


  • A High-Performance Wearable Ag/Ti3C2Tx MXene-Based Fiber Sensor for Temperature Sensing, Pressure Sensing, and Human Motion Detection

    by Hailian Liu, Ning Yang, Qi Zhang, Fang Wang, Xin Yan, Xuenan Zhang, Tonglei Cheng

    In this work, a high-performance wearable sensor of excellent flexibility was fabricated by dip-coating Ti 3 C 2 T x MXene material (M) on a polyester fiber (PET) substrate and depositing silver nanoparticles (Ag) by magnetron sputtering. The Ag/M/PET fiber sensor not only responds well to the stimuli of temperature, pressure/strain signals, but also exhibits high temperature sensitivity (0~10 °C: -3.4938 % °C -1 , 10~30 °C: -1.0436 % °C -1 ), relatively fast response and recovery time to pressure (130 ms), low-pressure detection limit (6.5 mg, 1 cm 2 ), and good cycling stability (1000 cycles). The proposed fiber sensor has the advantages of high sensitivity, simple structure, convenient fabrication, and excellent multimodal sensing capability, which makes it a valuable candidate for human motion detection and personal healthcare.


  • Fluorescent Optical Fiber Intensity Ratio Temperature Sensor Based on Polymer Matrix Using Down-Conversion From ZnS:Cu

    by Bin Li, Fan Zhang, Wei Liu, Xiaoyu Chen, Yuanhongliu Gao, Qi Zhang, Xin Yan, Fang Wang, Xuenan Zhang, Takenobu Suzuki, et al.

    Aiming at the problem of long-term dependence on rare-earth (RE) ions and insufficient stability of a fluorescent optical fiber temperature sensor, a fluorescence intensity ratio (FIR) temperature sensor based on ZnS:Cu was proposed. ZnS:Cu powder is adhered to the end face of multimode quartz fiber by blending into polydimethylsiloxane (PDMS). PDMS improves the coupling efficiency between fluorescence and quartz fiber and provides sufficient adhesion for the powder. Benefiting from the temperature dependence of ZnS:Cu, the intensity ratio of the two down-conversion (DC) luminescence bands excited by ultraviolet (UV) varies with temperature. The results of experimental verification confirm that the sensor has excellent linear response ( $R^{2} =0.991$ ), stability, and repeatability in the temperature range of 20.1 °C–101 °C, with an average temperature sensitivity of −0.00515 °C −1 . These characteristics show that the designed sensor has great potential in temperature sensing applications, and the proposed ZnS:Cu, which can replace RE ions, is an excellent candidate for the fluorescent optical fiber temperature sensor.