B. Rajasekar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
B. Rajasekar has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Aarti Sangwan
Central University of Haryana, Mahendergarh, India
1 shared publicationAshu Gautam
G.D. Goenka University, India
1 shared publicationGnana Kousalya C.
St. Joseph's Institute of Technology, India
1 shared publication- Kavitha Krishnaswamy Pillai Ranganathan
Sona College of Technology
1 shared publication N. M. Nandhitha
Sathyabama Institute of Science and Technology, India
1 shared publication- Nikhil Marriwala
University Institute of Engineering and Technology, Kurukshetra University
1 shared publication
Latest Publications
- Open Access
- 1 January 2023
- Published by IGI Global Scientific Publishing in International Journal of Decision Support System Technology
- Vol. 15 (1) , 1-31
Novel Real-Time Decision-Based Carrier Tracking for Software-Defined Radios Using M-ARY QAM Modulation
In this paper, a scalable and real-time decision-based carrier tracking for software defined radio (SDR) for M-ary QAM modulation has been proposed and tested in real-time using the universal software radio peripheral (USRP)-2922. The proposed system provides real-time decision-based carrier tracking for improved efficiency and performance. The real-time transfer of data has been done using the USRP-2922 hardware using the M-ary QAM modulation scheme for data transmission. The novelty of the proposed system is that one can transfer random data (binary bits), text or an image which can be encoded using the desired forward error correction codes (FEC) namely the convolution coding/Viterbi soft decision decoding and the turbo coding/decoding. The proposed novel SDR transceiver system with real-time decision-based carrier tracking shows an improved performance for different parameters such as the bit error rate (BER) and signal to noise ratio (Eb/No).
- 1 January 2023
- Published by IGI Global Scientific Publishing in International Journal of Decision Support System Technology
- Vol. 15 (1) , 1-31
Open AccessNovel Real-Time Decision-Based Carrier Tracking for Software-Defined Radios Using M-ARY QAM Modulation
In this paper, a scalable and real-time decision-based carrier tracking for software defined radio (SDR) for M-ary QAM modulation has been proposed and tested in real-time using the universal software radio peripheral (USRP)-2922. The proposed system provides real-time decision-based carrier tracking for improved efficiency and performance. The real-time transfer of data has been done using the USRP-2922 hardware using the M-ary QAM modulation scheme for data transmission. The novelty of the proposed system is that one can transfer random data (binary bits), text or an image which can be encoded using the desired forward error correction codes (FEC) namely the convolution coding/Viterbi soft decision decoding and the turbo coding/decoding. The proposed novel SDR transceiver system with real-time decision-based carrier tracking shows an improved performance for different parameters such as the bit error rate (BER) and signal to noise ratio (Eb/No).
- RetractedOpen Access
- 21 August 2022
- Published by Wiley in BioMed Research International
- Vol. 2022 (1) , 7358575
[Retracted] A Feasible Multimodal Photoacoustic Imaging Approach for Evaluating the Clinical Symptoms of Inflammatory Arthritis
Numerous traditional medical imaging methods, including computed tomography with X‐rays, positron emission tomography (PET), and magnetic resonance imaging (MRI), are utilized frequently in medical settings to screen for illnesses, diagnose patients, and track the effectiveness of treatments. When examining bone protrusions, CT is preferred over MRI for scanning connective tissue. Although the picture quality of PET is inferior to that of CT and MR, it is outstanding for detecting the molecular markers and metabolic functions of illnesses. To give high‐resolution structural pictures and improved ailment sensitivity and specificity within another image, multimodal data and substantial therapeutic influence on advanced diagnostics and therapeutics have been used. The goal was to evaluate the clinical significance of multimodal photoacoustic/ultrasound (PA/US) articular imaging scoring, a cutting‐edge image technique that may show the microvessels and oxygen levels of rheumatoid arthritis‐related inflamed joints (RA). The PA/US imaging technology analyzed seven tiny joints. The PA and power Doppler (PD) impulses were semiquantified using a 0–3 grading scale, and the averages of the PA and PD scores for the seven joints are computed. Three PA+SO2 types were found determined by the relative oxygen levels (SO2) measurements of the affected joints. Researchers evaluated the relationships between the disease activity ratings and the PA/US imaging ratings. The PA scores and medical ratings that reflect the extent of the pain have strong relationships with each other, as do the PA+SO2 combinations. PA may be clinically useful in assessing RA. Thus, the research evaluated the clinical symptoms of inflammatory arthritis using a multimodal photoacoustic image process.
- 21 August 2022
- Published by Wiley in BioMed Research International
- Vol. 2022 (1) , 7358575
RetractedOpen Access[Retracted] A Feasible Multimodal Photoacoustic Imaging Approach for Evaluating the Clinical Symptoms of Inflammatory Arthritis
Numerous traditional medical imaging methods, including computed tomography with X‐rays, positron emission tomography (PET), and magnetic resonance imaging (MRI), are utilized frequently in medical settings to screen for illnesses, diagnose patients, and track the effectiveness of treatments. When examining bone protrusions, CT is preferred over MRI for scanning connective tissue. Although the picture quality of PET is inferior to that of CT and MR, it is outstanding for detecting the molecular markers and metabolic functions of illnesses. To give high‐resolution structural pictures and improved ailment sensitivity and specificity within another image, multimodal data and substantial therapeutic influence on advanced diagnostics and therapeutics have been used. The goal was to evaluate the clinical significance of multimodal photoacoustic/ultrasound (PA/US) articular imaging scoring, a cutting‐edge image technique that may show the microvessels and oxygen levels of rheumatoid arthritis‐related inflamed joints (RA). The PA/US imaging technology analyzed seven tiny joints. The PA and power Doppler (PD) impulses were semiquantified using a 0–3 grading scale, and the averages of the PA and PD scores for the seven joints are computed. Three PA+SO2 types were found determined by the relative oxygen levels (SO2) measurements of the affected joints. Researchers evaluated the relationships between the disease activity ratings and the PA/US imaging ratings. The PA scores and medical ratings that reflect the extent of the pain have strong relationships with each other, as do the PA+SO2 combinations. PA may be clinically useful in assessing RA. Thus, the research evaluated the clinical symptoms of inflammatory arthritis using a multimodal photoacoustic image process.