Christopher I. McHugh
Research Subjects
Christopher I. McHugh has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Hideko Heidi Nakajima
Department of Otolaryngology - Head&Neck Surgery, Harvard Medical School, Boston, USA
4 shared publications - Ioannis Kymissis
Department of Electrical Engineering, Columbia University, New York, USA
3 shared publications - Jeffrey H. Lang
Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, USA
3 shared publications - Aaron Yeiser
Department of Electrical Engineering and Computer Science, MIT, Cambridge, MA 02139, United States of America
2 shared publications - Aleksandrs Zosuls
Eaton-Peabody Laboratories, Department of Otolaryngology-Head and Neck Surgery, Mass Eye and Ear, Boston, MA, 02114, USA
2 shared publications - Benjamin G. Cary
Department of Electrical Engineering and Computer Sciences University of California Berkeley CA 94720 USA
2 shared publications
Latest Publications
- Open Access
Sound-Driven Motion of Human Cochlear Structures Depends on Organ of Corti Integrity
Optical coherence tomography (OCT) was used to image and measure the passive sound-driven displacements of cochlear structures in situ through the intact round window membrane of fresh human cadaveric specimens at 12 to 30 hours postmortem. We find that the anatomical integrity of the organ of Corti (OoC) affects cochlear structural motion. OoC with high integrity (erect with supporting cells) have small osseous spiral lamina (OSL) motion. Conversely, OoC with low integrity (flattened without supporting cells) have large OSL motion. For the ratio of motion between the basilar membrane (BM) and OSL (BM/OSL), OoC with high integrity has large BM/OSL motion while a cochlear partition without OoC has small BM/OSL motion. Furthermore, the high-integrity OoC has reticular lamina surface motion that is lower than the BM, whereas low-integrity OoC has similar reticular lamina and BM motion. This relationship between OoC anatomical integrity and cochlear structural motion will have consequential effects on sound transduction. Statement of Significance: Acoustic vibrations are transformed into neural signals within the cochlea, the mammalian organ of hearing. Our understanding of cochlear mechanics has been limited to laboratory animals, whose cochleae have significant anatomical and functional differences from humans. To bridge this gap, we imaged and recorded the motion of cochlear structures in intact human cadaveric cochlear specimens without disturbing the interior of the cochlea. We determined how the anatomical integrity of the Organ of Corti (that contains structures for sound transduction) affects cochlear structural motion.
Open AccessSound-Driven Motion of Human Cochlear Structures Depends on Organ of Corti Integrity
Optical coherence tomography (OCT) was used to image and measure the passive sound-driven displacements of cochlear structures in situ through the intact round window membrane of fresh human cadaveric specimens at 12 to 30 hours postmortem. We find that the anatomical integrity of the organ of Corti (OoC) affects cochlear structural motion. OoC with high integrity (erect with supporting cells) have small osseous spiral lamina (OSL) motion. Conversely, OoC with low integrity (flattened without supporting cells) have large OSL motion. For the ratio of motion between the basilar membrane (BM) and OSL (BM/OSL), OoC with high integrity has large BM/OSL motion while a cochlear partition without OoC has small BM/OSL motion. Furthermore, the high-integrity OoC has reticular lamina surface motion that is lower than the BM, whereas low-integrity OoC has similar reticular lamina and BM motion. This relationship between OoC anatomical integrity and cochlear structural motion will have consequential effects on sound transduction. Statement of Significance: Acoustic vibrations are transformed into neural signals within the cochlea, the mammalian organ of hearing. Our understanding of cochlear mechanics has been limited to laboratory animals, whose cochleae have significant anatomical and functional differences from humans. To bridge this gap, we imaged and recorded the motion of cochlear structures in intact human cadaveric cochlear specimens without disturbing the interior of the cochlea. We determined how the anatomical integrity of the Organ of Corti (that contains structures for sound transduction) affects cochlear structural motion.
- Open Access
Anatomical integrity of the human cochlea estimated with optical coherence tomography for future clinical application
The human cochlea is encased within the otic capsule, the densest bone in the body, posing significant challenges for anatomical imaging of cochlear structures. Because of difficult access and fragility of cochlear structures, our understanding of intracochlear anatomy has historically relied on postmortem histology. We thus have a limited understanding of human cochlear anatomy in its native, unfixed state. Clinical diagnostics for hearing loss, such as audiometry and otoacoustic emissions, offer functional assessments but fail to elucidate the often diverse underlying structural pathologies with any degree of precision. To address the critical need for assessing the human cochlear anatomy and associated pathologies without the risk of traumatizing cochlear structures, we imaged fresh cochleae in situ soon after death through the intact round window membrane with Optical Coherence Tomography (OCT) without inserting instruments inside or opening the cochlea. Micron-resolution OCT cross-sectional images of the human intracochlear structures were acquired and compared with corresponding histology systematically to aid in the identification of fine structural features and possible pathologies. With OCT imaging, we observed varied anatomy of the organ of Corti, and developed a cochlear ″integrity″ rating system to differentiate healthy appearing cochleae from various pathological states. These results demonstrate the capability of OCT to non-traumatically visualize cochlear integrity, highlighting its potential as a diagnostic tool. This work shows promise in translating the ability to determine the likelihood of existing or lack of hair cells and supporting cells in live patients, which would enable appropriate targeted treatments.
Open AccessAnatomical integrity of the human cochlea estimated with optical coherence tomography for future clinical application
The human cochlea is encased within the otic capsule, the densest bone in the body, posing significant challenges for anatomical imaging of cochlear structures. Because of difficult access and fragility of cochlear structures, our understanding of intracochlear anatomy has historically relied on postmortem histology. We thus have a limited understanding of human cochlear anatomy in its native, unfixed state. Clinical diagnostics for hearing loss, such as audiometry and otoacoustic emissions, offer functional assessments but fail to elucidate the often diverse underlying structural pathologies with any degree of precision. To address the critical need for assessing the human cochlear anatomy and associated pathologies without the risk of traumatizing cochlear structures, we imaged fresh cochleae in situ soon after death through the intact round window membrane with Optical Coherence Tomography (OCT) without inserting instruments inside or opening the cochlea. Micron-resolution OCT cross-sectional images of the human intracochlear structures were acquired and compared with corresponding histology systematically to aid in the identification of fine structural features and possible pathologies. With OCT imaging, we observed varied anatomy of the organ of Corti, and developed a cochlear ″integrity″ rating system to differentiate healthy appearing cochleae from various pathological states. These results demonstrate the capability of OCT to non-traumatically visualize cochlear integrity, highlighting its potential as a diagnostic tool. This work shows promise in translating the ability to determine the likelihood of existing or lack of hair cells and supporting cells in live patients, which would enable appropriate targeted treatments.
- 18 July 2024
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 34 (8) , 085010
The UmboMic: a PVDF cantilever microphone *
Objective. We present the ‘UmboMic,’ a prototype piezoelectric cantilever microphone designed for future use with totally-implantable cochlear implants. Methods. The UmboMic sensor is made from polyvinylidene difluoride (PVDF) because of its low Young’s modulus and biocompatibility. The sensor is designed to fit in the middle ear and measure the motion of the underside of the eardrum at the umbo. To maximize its performance, we developed a low noise charge amplifier in tandem with the UmboMic sensor. This paper presents the performance of the UmboMic sensor and amplifier in fresh cadaveric human temporal bones. Results. When tested in human temporal bones, the UmboMic apparatus achieves an equivalent input noise of 32.3 dB SPL over the frequency range 100 Hz–7 kHz, good linearity, and a flat frequency response to within 10 dB from about 100 Hz–6 kHz. Conclusion. These results demonstrate the feasibility of a PVDF-based microphone when paired with a low-noise amplifier. The reported UmboMic apparatus is comparable in performance to a conventional hearing aid microphone. Significance. The proof-of-concept UmboMic apparatus is a promising step towards creating a totally-implantable cochlear implant. A completely internal system would enhance the quality of life of cochlear implant users.
- 18 July 2024
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 34 (8) , 085010
The UmboMic: a PVDF cantilever microphone *
Objective. We present the ‘UmboMic,’ a prototype piezoelectric cantilever microphone designed for future use with totally-implantable cochlear implants. Methods. The UmboMic sensor is made from polyvinylidene difluoride (PVDF) because of its low Young’s modulus and biocompatibility. The sensor is designed to fit in the middle ear and measure the motion of the underside of the eardrum at the umbo. To maximize its performance, we developed a low noise charge amplifier in tandem with the UmboMic sensor. This paper presents the performance of the UmboMic sensor and amplifier in fresh cadaveric human temporal bones. Results. When tested in human temporal bones, the UmboMic apparatus achieves an equivalent input noise of 32.3 dB SPL over the frequency range 100 Hz–7 kHz, good linearity, and a flat frequency response to within 10 dB from about 100 Hz–6 kHz. Conclusion. These results demonstrate the feasibility of a PVDF-based microphone when paired with a low-noise amplifier. The reported UmboMic apparatus is comparable in performance to a conventional hearing aid microphone. Significance. The proof-of-concept UmboMic apparatus is a promising step towards creating a totally-implantable cochlear implant. A completely internal system would enhance the quality of life of cochlear implant users.
- 3 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (22) , 22161-22168
An Umbo Microphone for Fully-Implantable Assistive Hearing Devices
This article presents an implantable microphone for sensing the displacement of the umbo, the end of the malleus where it attaches to the center tip of the cone-shaped tympanic membrane. The sensor comprises a piezoelectric polyvinylidene fluoride (PVDF) film with copper–nickel electrodes suspended across a brass cylinder. The cylinder is oriented so that the umbo pushes on the film center, causing a static and acoustically driven dynamic film displacement. An amplifier filters the resulting piezoelectric charge to produce an output signal. The sensor enables the full implantation of assistive hearing devices, which can restore hearing without inhibiting the user’s lifestyle, while enabling better sound localization in noisy environments.
- 3 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (22) , 22161-22168
An Umbo Microphone for Fully-Implantable Assistive Hearing Devices
This article presents an implantable microphone for sensing the displacement of the umbo, the end of the malleus where it attaches to the center tip of the cone-shaped tympanic membrane. The sensor comprises a piezoelectric polyvinylidene fluoride (PVDF) film with copper–nickel electrodes suspended across a brass cylinder. The cylinder is oriented so that the umbo pushes on the film center, causing a static and acoustically driven dynamic film displacement. An amplifier filters the resulting piezoelectric charge to produce an output signal. The sensor enables the full implantation of assistive hearing devices, which can restore hearing without inhibiting the user’s lifestyle, while enabling better sound localization in noisy environments.
- 15 August 2022
- Published by Wiley in The Laryngoscope
- Vol. 133 (5) , 1222-1227
Middle Fossa Decompression for Recurrent Facial Palsy: Prevalence and Surgical Outcomes
Objective: To investigate the surgical outcomes in patients treated for recurrent facial nerve palsy (RFP) at a quaternary facial nerve referral center.Methods: A retrospective chart review was performed on 132 patients with RFP who presented to our institution's facial nerve clinic from 2001 to 2021. Records were analyzed for etiology of palsy, facial nerve function, and recurrence rates. Pre‐ and post‐operative audiometric outcomes were also assessed in surgically managed patients.Results: 6.8% of RFP patients underwent surgical decompression. For patients who did not undergo surgery, the House‐Brackmann (HB) score was 2.9 ± 1.3 (SD) at the initial clinic visit, and 2.4 ± 1.3 (SD) at the last clinic visit. This difference was significantly different (p = 0.01, t‐test). For surgical patients, the pre‐operative HB score was 2.9 ± 0.9 (SD) and post‐operative HB score was 1.8 ± 0.6 (SD), which were significantly different (p = 0.01, t‐test). The number of facial palsy episodes also decreased pre‐ and post‐operatively from 3.5 ± 0.8 (SD) to 0.2 ± 0.4 (SD) episodes, which were significantly different (p < 0,001, t‐test). Audiometric outcomes were not significantly different pre‐ and post‐surgery (p = 0.31, t‐test for PTA; p = 0.34, t‐test for WRS).Conclusion: Facial nerve decompression for RFP patients with incomplete functional recovery may be an effective treatment for decreasing the frequency and severity of facial palsy episodes.Level of Evidence: 4 Laryngoscope, 133:1222–1227, 2023
- 15 August 2022
- Published by Wiley in The Laryngoscope
- Vol. 133 (5) , 1222-1227
Middle Fossa Decompression for Recurrent Facial Palsy: Prevalence and Surgical Outcomes
Objective: To investigate the surgical outcomes in patients treated for recurrent facial nerve palsy (RFP) at a quaternary facial nerve referral center.Methods: A retrospective chart review was performed on 132 patients with RFP who presented to our institution's facial nerve clinic from 2001 to 2021. Records were analyzed for etiology of palsy, facial nerve function, and recurrence rates. Pre‐ and post‐operative audiometric outcomes were also assessed in surgically managed patients.Results: 6.8% of RFP patients underwent surgical decompression. For patients who did not undergo surgery, the House‐Brackmann (HB) score was 2.9 ± 1.3 (SD) at the initial clinic visit, and 2.4 ± 1.3 (SD) at the last clinic visit. This difference was significantly different (p = 0.01, t‐test). For surgical patients, the pre‐operative HB score was 2.9 ± 0.9 (SD) and post‐operative HB score was 1.8 ± 0.6 (SD), which were significantly different (p = 0.01, t‐test). The number of facial palsy episodes also decreased pre‐ and post‐operatively from 3.5 ± 0.8 (SD) to 0.2 ± 0.4 (SD) episodes, which were significantly different (p < 0,001, t‐test). Audiometric outcomes were not significantly different pre‐ and post‐surgery (p = 0.31, t‐test for PTA; p = 0.34, t‐test for WRS).Conclusion: Facial nerve decompression for RFP patients with incomplete functional recovery may be an effective treatment for decreasing the frequency and severity of facial palsy episodes.Level of Evidence: 4 Laryngoscope, 133:1222–1227, 2023
- 9 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 408-411
A Pvdf-Trfe Intracochlear Hydrophone and Amplifier For Totally Implantable Cochlear Implants
This paper reports the analysis, design, and experimental characterization of a piezoelectric intracochlear hydrophone and amplifier system to function as an implantable microphone for totally-implantable cochlear implants. We derived an analytical model for the piezoelectric hydrophone, which we validated with finite-element modeling (FEM) and experiments. We developed a circuit and noise model of the amplifier, which we verified through measurements. We proposed a PVDF-TrFE intracochlear hydrophone with a charge amplifier co-designed for maximum performance: sensitivity, bandwidth, and output noise. To characterize the hydrophone and amplifier, we used a vibrating water column calibration method. We determined the shielding and experimental design considerations necessary to collect reliable data. The system presented here achieved an overall sensitivity of 20.6 mV/Pa at 3 kHz, a bandwidth of 470 Hz to 16 kHz, and a root-mean-square (RMS) output noise of 17.6 mV dominated by the amplifier. Our approach for an implantable microphone proves to be a promising candidate for cochlear implants.
- 9 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 408-411
A Pvdf-Trfe Intracochlear Hydrophone and Amplifier For Totally Implantable Cochlear Implants
This paper reports the analysis, design, and experimental characterization of a piezoelectric intracochlear hydrophone and amplifier system to function as an implantable microphone for totally-implantable cochlear implants. We derived an analytical model for the piezoelectric hydrophone, which we validated with finite-element modeling (FEM) and experiments. We developed a circuit and noise model of the amplifier, which we verified through measurements. We proposed a PVDF-TrFE intracochlear hydrophone with a charge amplifier co-designed for maximum performance: sensitivity, bandwidth, and output noise. To characterize the hydrophone and amplifier, we used a vibrating water column calibration method. We determined the shielding and experimental design considerations necessary to collect reliable data. The system presented here achieved an overall sensitivity of 20.6 mV/Pa at 3 kHz, a bandwidth of 470 Hz to 16 kHz, and a root-mean-square (RMS) output noise of 17.6 mV dominated by the amplifier. Our approach for an implantable microphone proves to be a promising candidate for cochlear implants.