Qiang Cao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Qiang Cao has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Guoyu Li
School of Mechanical Engineering, Shanghai Dianji University, Shanghai, People’s Republic of China
1 shared publication - Jiafeng Song
Suzhou Automobile Research Institute(Xiangcheng), Tsinghua University, Suzhou, China
1 shared publication Jianfeng Li
Beijing University of Technology
1 shared publicationMingjie Dong
Beijing University of Technology
1 shared publication- Qiang Cao
School of Intelligent Manufacturing and Robotics, Shanghai Dianji University, Shanghai 201306, China
1 shared publication - Rui Zhang
Key Laboratory of Bionic Engineering, Ministry of Education, Jilin University, Changchun, China
1 shared publication
Latest Publications
- Open Access
- 22 November 2025
- Published by MDPI AG in Biomimetics
- Vol. 10 (12) , 795
Enhancing Human–Robot Compatibility in Shoulder Exoskeletons: Passive Joint Optimization of PPRRRP vs. RRRUP Configurations
This study aims to evaluate the kinematic performance of two shoulder rehabilitation exoskeleton configurations to address the critical challenge of human–robot compatibility. Utilizing Hunt’s mobility formula and task-specific Jacobian analysis, we developed a closed-chain kinematic model integrating transient glenohumeral joint dynamics, validated through force/torque measurements and ANOVA statistical comparisons. The PPRRRP configuration, featuring orthogonally distributed passive prismatic joints, demonstrated superior performance: 40–60% lower interaction forces (), near-isotropic manipulability (ellipsoid axis ratio < 1.5), and 60% reduced operational torque () compared to RRRUP’s universal joint design. These results establish passive DOF optimization as a viable alternative to actuator-dense systems, diverging from conventional approaches like ARMin-III that prioritize active control. The originality lies in bridging theoretical configuration synthesis with empirical validation, offering a replicable framework for compatibility assessment. This work advances rehabilitation robotics by demonstrating that mechanical transparency—achieved through strategic passive joint allocation—enhances natural movement synergy without compromising stability, proposing hypotheses on energy efficiency and isotropy–fatigue correlations for future exploration. Clinical translation and adaptive impedance control integration are identified as critical next steps to optimize patient-specific rehabilitation outcomes.- 22 November 2025
- Published by MDPI AG in Biomimetics
- Vol. 10 (12) , 795
Open AccessEnhancing Human–Robot Compatibility in Shoulder Exoskeletons: Passive Joint Optimization of PPRRRP vs. RRRUP Configurations
This study aims to evaluate the kinematic performance of two shoulder rehabilitation exoskeleton configurations to address the critical challenge of human–robot compatibility. Utilizing Hunt’s mobility formula and task-specific Jacobian analysis, we developed a closed-chain kinematic model integrating transient glenohumeral joint dynamics, validated through force/torque measurements and ANOVA statistical comparisons. The PPRRRP configuration, featuring orthogonally distributed passive prismatic joints, demonstrated superior performance: 40–60% lower interaction forces (), near-isotropic manipulability (ellipsoid axis ratio < 1.5), and 60% reduced operational torque () compared to RRRUP’s universal joint design. These results establish passive DOF optimization as a viable alternative to actuator-dense systems, diverging from conventional approaches like ARMin-III that prioritize active control. The originality lies in bridging theoretical configuration synthesis with empirical validation, offering a replicable framework for compatibility assessment. This work advances rehabilitation robotics by demonstrating that mechanical transparency—achieved through strategic passive joint allocation—enhances natural movement synergy without compromising stability, proposing hypotheses on energy efficiency and isotropy–fatigue correlations for future exploration. Clinical translation and adaptive impedance control integration are identified as critical next steps to optimize patient-specific rehabilitation outcomes. - Open Access
- 12 December 2023
- Published by MDPI AG in Biomimetics
- Vol. 8 (8) , 600
Foot Bionics Research Based on Reindeer Hoof Attachment Mechanism and Macro/Microstructures
The attachment performances of mechanical feet are significant in improving the trafficability and mobility of robots on the extreme ground. In the future, frozen-ground robots can be used to replace human soldiers in scouting and deep space exploration. In this study, the influence factors on the attachment function of the bionic feet were analyzed. Soft frozen soil and tight frozen soil close to natural frozen soil were prepared, and the friction between ungula and frozen soil ground was simulated together with the plantar pressures of reindeer under trotting. The major attachment parts were the ungula cusp, outer edges, and ungula capsules, and the stress on the ungula was mainly 4.56–24.72 MPa. According to the microstructures of plantar fur and ungula, the corresponding ratio of the rib width and length was 0.65:1, and the corresponding ratio of the rib width and distance was 3:1. In addition, the scales of the plantar fur were very tightly arranged and had large ripples. Based on typical curves, an ungula capsule-curved surface, and a nonsmooth plantar fur surface, four types of bionic feet and the corresponding ordinary multidamboard foot were designed. On the frozen soil, the bionic foot with ribs and an ungula capsule showed the best attachment performance. Compared with the multidamboard foot, the dynamic coefficient of friction of the bionic foot with ribs and ungula capsules increased by 11.43–31.75%. The attachment mechanism of the bionic feet is as follows: under the action of pressure, the fine patterns of the bionic convex-crown generate friction with the nonsmooth structure of the frozen soil surface, which improves the attachment performance.
- 12 December 2023
- Published by MDPI AG in Biomimetics
- Vol. 8 (8) , 600
Open AccessFoot Bionics Research Based on Reindeer Hoof Attachment Mechanism and Macro/Microstructures
The attachment performances of mechanical feet are significant in improving the trafficability and mobility of robots on the extreme ground. In the future, frozen-ground robots can be used to replace human soldiers in scouting and deep space exploration. In this study, the influence factors on the attachment function of the bionic feet were analyzed. Soft frozen soil and tight frozen soil close to natural frozen soil were prepared, and the friction between ungula and frozen soil ground was simulated together with the plantar pressures of reindeer under trotting. The major attachment parts were the ungula cusp, outer edges, and ungula capsules, and the stress on the ungula was mainly 4.56–24.72 MPa. According to the microstructures of plantar fur and ungula, the corresponding ratio of the rib width and length was 0.65:1, and the corresponding ratio of the rib width and distance was 3:1. In addition, the scales of the plantar fur were very tightly arranged and had large ripples. Based on typical curves, an ungula capsule-curved surface, and a nonsmooth plantar fur surface, four types of bionic feet and the corresponding ordinary multidamboard foot were designed. On the frozen soil, the bionic foot with ribs and an ungula capsule showed the best attachment performance. Compared with the multidamboard foot, the dynamic coefficient of friction of the bionic foot with ribs and ungula capsules increased by 11.43–31.75%. The attachment mechanism of the bionic feet is as follows: under the action of pressure, the fine patterns of the bionic convex-crown generate friction with the nonsmooth structure of the frozen soil surface, which improves the attachment performance.
- Open Access
- 22 August 2022
- Published by Springer Nature in Research Square
A Methodology to Estimate Human-Robot Interaction Forces: A Case Study of a 4-DOFs Upper Extremity Rehabilitation Robot
Due to the advantages of high durability, great repeatability and task orientation, the upper extremity rehabilitation robots have become a gospel for the rehabilitation treatment of stroke patients. The evaluation system for the comfort performance of rehabilitation robots has always been a research hotspot, and how to calculate the human-robot interaction forces is a challenge for the comfort evaluation. In this article, a four degrees of freedom (4-DOFs) upper extremity robot mechanism that is kinematically compatible with the upper limb is presented. Then, taking this mechanism as the research object, an algorithm for estimating human-robot interaction forces is addressed based on Newton-Euler dynamic. Subsequently, a prototype of the proposed robot is developed, and a comparison experiment of interaction forces is carried out on the prototype. The comparative experimental outcomes indicate that the presented algorithm for calculating the human-robot interaction forces is feasible. The findings of this paper provide a prerequisite for the evaluation of the robot comfort, which is of great practical significance.
- 22 August 2022
- Published by Springer Nature in Research Square
Open AccessA Methodology to Estimate Human-Robot Interaction Forces: A Case Study of a 4-DOFs Upper Extremity Rehabilitation Robot
Due to the advantages of high durability, great repeatability and task orientation, the upper extremity rehabilitation robots have become a gospel for the rehabilitation treatment of stroke patients. The evaluation system for the comfort performance of rehabilitation robots has always been a research hotspot, and how to calculate the human-robot interaction forces is a challenge for the comfort evaluation. In this article, a four degrees of freedom (4-DOFs) upper extremity robot mechanism that is kinematically compatible with the upper limb is presented. Then, taking this mechanism as the research object, an algorithm for estimating human-robot interaction forces is addressed based on Newton-Euler dynamic. Subsequently, a prototype of the proposed robot is developed, and a comparison experiment of interaction forces is carried out on the prototype. The comparative experimental outcomes indicate that the presented algorithm for calculating the human-robot interaction forces is feasible. The findings of this paper provide a prerequisite for the evaluation of the robot comfort, which is of great practical significance.