RSRaed G. Saihood

Raed G. Saihood

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Raed G. Saihood has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Numerical Analysis of Mixed Convection in Vented Curved Cavity With a Metal Foam Layer

    by Luma F. Ali, Raed G. Saihood

    Heat transfer applications usually contemplated day‐to‐day are primarily spotlighted on mixed convection, such as solar collector heating arrangements, electronic cooling, and drying processes. Enhancing convection heat transmission in such appliances can be achieved by inserting porous media, inflow loci, and/or line geometry. In the present paper, convection heat transmission inside a vented curved cavity () with an inserted metal foam layer ( PPI and 0.9% porosity) saturated with water was accomplished. The bottom cavity wall was discretely heated at a constant hot temperature, and the curved wall was kept at a constant cold temperature. Governing equations comprising continuity, momentum with the Darcy–Brinkmann–Forchheimer model, and local thermal equilibrium energy equation have been used and numerically resolved by utilizing the finite element scheme. The inspirations of pertinent parameters involving metal foam layer thickness (), Richardson number (, , ), Reynolds number (), inlet port position (, , ), and partial heating position (, , ) are scrutinized. The results reveal that flow and heat transfer fields are influenced chiefly by these parameter alterations. Streamlines and isotherms were affected strongly by Reynolds number and inlet port location. The average Nusselt number highly depended on the Reynolds number and the metal foam layer insertion. When and , increasing the metal foam layer thickness enlarges cavity regions with high temperature values, but when , another performance is attained. The position at is recommended in most thermal engineering applications.

  • Flow Boiling Analysis for HFE‐7100 in a Vertical Porous Tube

    by Raed G. Saihood, Mohammed A. Nima

    Much recent research has focused on dielectric fluids in engineering applications because of their physical properties. In this study, the use of HFE‐7100 as a working fluid in a porous pipe exposed to thermal conditions like solar radiation conditions in Baghdad city was studied. The two‐phase mixture model with Local Thermal Non‐Equilibrium assumption was applied to analyze the flow boiling of a subcooled HFE‐7100 in a vertical pipe filled with high porosity metal foam. The Finite volume approach with MATLAB code was used to solve the governing equations like continuity, momentum based on Forchheimer‐extended Darcy model and energy equations. The results displayed that the heat transfer rises with the rise in pore density, porosity and the heat flux while the liquid saturation reduces with the raise in heat flux and pore density and the decrease in porosity of the metal foam. PPI effect is more effective at low porosity, as it increases the heat transfer coefficient by 101%, 95%, and 88% at 0.8, 0.9, and 0.95 porosity, respectively. But the effect of porosity is very small compared to PPI effect on the liquid saturation where it decreases by 4% when the porosity decreases from 0.95 to 0.85, while it decreases by 23% when the pore density increases from 10 to 110 PPI.

  • Experimental Study on the Performance of Gradient Pores Density Metal Foam in a Rectangular Channel

    by Mohammed H. Hasan, Raed G. Saihood

    Various approaches are employed to enhance the heat transfer coefficient and Nusselt number inside the channels. One of the techniques employed for these enhancements is the utilization of porous media. In the current article, a practical investigation of forced convection heat transfer in a rectangular cross‐section channel (0.05 × 0.1 m2) with 0.25 m length is conducted. A heater with a heat flux range (450–6000 W/m2) is imposed under a copper plate, and the other sides are covered by insulation layers. The air is considered as a working fluid with Re (600–2100). The test section is fully filled with gradient pores per inch (PPI) metal foam by taking three different pores densities PPI (10, 20, and 40 PPI) and studying its effects on the temperature of copper plate, the local heat transfer coefficient, average Nusselt number, pressure drop, friction factor, and the performance factor. Three cases were studied inside the channel: one empty case and two with gradient pore density case A (40–20–10) PPI and case B (10–20–40) PPI. The results showed that inserting the metal foam inside the channel improves h and Nu. Case B appeared the best of this improvement in h and Nu by 12% and 25%, respectively, compared with that in case A. While the friction factor was the same for two cases A and B. So, the performance factor in case B showed an improvement of around 25% and 50% in comparison to case A and the empty case, respectively.


  • Experimental study on thermo‐hydraulic performance of metal foam twisted tape in a double pipe heat exchanger

    by Issam M. A. Aljubury, Raed G. Saihood, Ammar A. Farhan

    A recent study compared experimentally the hydraulic and thermal activity of twisted tape inserts for two types, metal foam twisted tape (MFTT) and traditional twisted tape (TTT), in a double pipe heat exchanger. The investigation goal of the innovatively designed MFTT is to enhance the heat transfer process, which provides a higher thermal enhancement factor over those of TTT under the same conditions. Heat transfer activity in terms of Nusselt number (Nu) and Nusselt number ratio (Nu/Nuo) as the heat exchanger equipped with the proposed MFTT and TTT inserts with various tape‐twist ratios (y/W = 3.6, 5.2, and 6.8) are considered over various values of Reynolds numbers (16,300 < Re < 32,500). The results reveal an improvement in heat transfer rate with both MFTT and TTT and this improvement is proportional inversely to the twisted ratio, but the MFTT showed the highest value of heat transfer compared to TTT and clear tube. Also, the Nu of MFTT augments averaged about 175%–230% compared to the TTT depending on the twist ratio and about 275% and 500% over that of the clear tube. At a twist ratio of 3.6, the heat transfer coefficient is recorded at 37% and 45% for MFTT and TTT models, respectively, with an increase in Re. However, friction factor (f) increases about 35% for MFTT with decreasing in twist ratio (from 6.8 to 3.6). The effectiveness of the proposed MFTT in the range of Re used is found to be about 12%, 15%, and 18% higher than those induced by TTT at twisted tape ratio (y/w = 3.6, 5.2, and 6.8), respectively.