Julia Zofia Tomaszewska
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Julia Zofia Tomaszewska has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Christos Chousidis
Department of Music and Media, Institute of Sound Recording, University of Surrey, Guildford GU2 7XH, UK
2 shared publications Apostolos Georgakis
1 shared publication- Apostolos Georgakis
School of Computing and Engineering, University of West London, London W5 5RF, UK
1 shared publication - Apostolos Georgakis
Division of Engineering, King's College London, WC2R 2LS, UK
1 shared publication - Eugenio Donati
School of Computing and Engineering, University of West London, London W5 5RF, UK
1 shared publication - Magdalena Ładogórska
Institute of Metrology and Biomedical Engineering, Faculty of Mechatronics, Warsaw University of Technology, 02-525 Warsaw, Poland
1 shared publication
Latest Publications
- Open Access
- 19 January 2026
- Published by Elsevier in Biomedical Engineering Advances
- Vol. 11
Audio-based deep learning classification of laryngeal pathologies with detection of precancerous and cancerous lesions using Gammatone Cepstral coefficients
- 19 January 2026
- Published by Elsevier in Biomedical Engineering Advances
- Vol. 11
Open AccessAudio-based deep learning classification of laryngeal pathologies with detection of precancerous and cancerous lesions using Gammatone Cepstral coefficients
- Open Access
- 21 February 2025
- Published by University of West London in New Vistas
- Vol. 11 (1)
Classification of laryngeal pathologies using audio, bioimpedance measurements and deep learning
- 21 February 2025
- Published by University of West London in New Vistas
- Vol. 11 (1)
Open AccessClassification of laryngeal pathologies using audio, bioimpedance measurements and deep learning
- Open Access
- 23 December 2023
- Published by Elsevier in Journal of Voice
- Vol. 40 (3) , 786-811
Electroglottography in Medical Diagnostics of Vocal Tract Pathologies: A Systematic Review
- 23 December 2023
- Published by Elsevier in Journal of Voice
- Vol. 40 (3) , 786-811
Open AccessElectroglottography in Medical Diagnostics of Vocal Tract Pathologies: A Systematic Review
- Open Access
- 11 September 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (18) , 2914
Automatic Heart Rate Detection during Sleep Using Tracheal Audio Recordings from Wireless Acoustic Sensor
Background: Heart rate is an essential diagnostic parameter indicating a patient’s condition. The assessment of heart rate is also a crucial parameter in the diagnostics of various sleep disorders, including sleep apnoea, as well as sleep/wake pattern analysis. It is usually measured using an electrocardiograph (ECG)—a device monitoring the electrical activity of the heart using several electrodes attached to a patient’s upper body—or photoplethysmography (PPG). Methods: The following paper investigates an alternative method for heart rate detection and monitoring that operates on tracheal audio recordings. Datasets for this research were obtained from six participants along with ECG Holter (for validation), as well as from fifty participants undergoing a full night polysomnography testing, during which both heart rate measurements and audio recordings were acquired. Results: The presented method implements a digital filtering and peak detection algorithm applied to audio recordings obtained with a wireless sensor using a contact microphone attached in the suprasternal notch. The system was validated using ECG Holter data, achieving over 92% accuracy. Furthermore, the proposed algorithm was evaluated against whole-night polysomnography-derived HR using Bland-Altman’s plots and Pearson’s Correlation Coefficient, reaching the average of 0.82 (0.93 maximum) with 0 BPM error tolerance and 0.89 (0.97 maximum) at ±3 BPM. Conclusions: The results prove that the proposed system serves the purpose of a precise heart rate monitoring tool that can conveniently assess HR during sleep as a part of a home-based sleep disorder diagnostics process.
- 11 September 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (18) , 2914
Open AccessAutomatic Heart Rate Detection during Sleep Using Tracheal Audio Recordings from Wireless Acoustic Sensor
Background: Heart rate is an essential diagnostic parameter indicating a patient’s condition. The assessment of heart rate is also a crucial parameter in the diagnostics of various sleep disorders, including sleep apnoea, as well as sleep/wake pattern analysis. It is usually measured using an electrocardiograph (ECG)—a device monitoring the electrical activity of the heart using several electrodes attached to a patient’s upper body—or photoplethysmography (PPG). Methods: The following paper investigates an alternative method for heart rate detection and monitoring that operates on tracheal audio recordings. Datasets for this research were obtained from six participants along with ECG Holter (for validation), as well as from fifty participants undergoing a full night polysomnography testing, during which both heart rate measurements and audio recordings were acquired. Results: The presented method implements a digital filtering and peak detection algorithm applied to audio recordings obtained with a wireless sensor using a contact microphone attached in the suprasternal notch. The system was validated using ECG Holter data, achieving over 92% accuracy. Furthermore, the proposed algorithm was evaluated against whole-night polysomnography-derived HR using Bland-Altman’s plots and Pearson’s Correlation Coefficient, reaching the average of 0.82 (0.93 maximum) with 0 BPM error tolerance and 0.89 (0.97 maximum) at ±3 BPM. Conclusions: The results prove that the proposed system serves the purpose of a precise heart rate monitoring tool that can conveniently assess HR during sleep as a part of a home-based sleep disorder diagnostics process.
- 22 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Sound-Based Cough Detection System using Convolutional Neural Network
Sound recording and processing techniques can be used in designing diagnostic solutions for a variety of medical conditions related to the respiratory system. In this spectrum, cough monitoring for chronic or seasonal conditions is a significant medical practice. In this paper, a precise cough identification and monitoring system is presented. The system is utilising a convolutional neural network as a feature extraction algorithm and classification system. Including several functions of loading the audio data into the system and converting it into a set of spectrograms, as well as the pre-segmentation stage function, the model retains its relatively low-complexity, which allows accelerating the learning process, also enhanced using dropout. Due to limited audio data available, the dataset dimension was established at 600 samples, split into two equal-numbered groups - 300 samples of “cough” samples, and 300 of “non-cough” samples. The validation accuracy (thus the percentage of samples labelled correctly by the system during the validation process) yielded over 84%, suggesting that this can be a successful cough detection method for future medical applications and devices, such as potential respiratory system condition diagnostic tool.
- 22 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Sound-Based Cough Detection System using Convolutional Neural Network
Sound recording and processing techniques can be used in designing diagnostic solutions for a variety of medical conditions related to the respiratory system. In this spectrum, cough monitoring for chronic or seasonal conditions is a significant medical practice. In this paper, a precise cough identification and monitoring system is presented. The system is utilising a convolutional neural network as a feature extraction algorithm and classification system. Including several functions of loading the audio data into the system and converting it into a set of spectrograms, as well as the pre-segmentation stage function, the model retains its relatively low-complexity, which allows accelerating the learning process, also enhanced using dropout. Due to limited audio data available, the dataset dimension was established at 600 samples, split into two equal-numbered groups - 300 samples of “cough” samples, and 300 of “non-cough” samples. The validation accuracy (thus the percentage of samples labelled correctly by the system during the validation process) yielded over 84%, suggesting that this can be a successful cough detection method for future medical applications and devices, such as potential respiratory system condition diagnostic tool.