Mehdi Ejtehadi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mehdi Ejtehadi has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Ana Cisnal
Universidad de Valladolid
2 shared publications - Bertram Fuchs
Spinal Cord Injury & Artificial Intelligence Lab, ETH Zurich, Zrich, Switzerland
2 shared publications - Diego Paez-Granados
ETH Zurich
2 shared publications - Yanke Li
Department of Health Science and Technology, ETH Zürich, Zürich, Switzerland
2 shared publications Ahmad R. Eslaminia
Department of Mechanical Engineering, Sharif University of Technology, Tehran, Iran
1 shared publicationAmin M. Nasrabadi
Djavad Mowaffaghiyan Research Center in Neuro-rehabilitation Technologies, Sharif University of Technology, Tehran, Iran; Department of Mechanical Engineering, Sharif University of Technology, Tehran, Iran
1 shared publication
Latest Publications
- 10 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 28 (10) , 5768-5779
Robust Feature Selection for BP Estimation in Multiple Populations: Towards Cuffless Ambulatory BP Monitoring
Current blood pressure (BP) estimation methods have not achieved an accurate and adaptable approach for ambulatory diagnosis and monitoring applications of populations at risk of cardiovascular disease, generally due to a limited sample size. This paper introduces an algorithm for BP estimation solely reliant on photoplethysmography (PPG) signals and demographic features. It automatically obtains signal features and employs the Markov Blanket (MB) feature selection to discern informative and transmissible features, achieving a robust space adaptable to the population shift. This approach was validated with the Aurora-BP database, compromising ambulatory wearable cuffless BP measurements for over 500 individuals. After evaluating several machine-learning regression methods, Gradient Boosting emerged as the most effective. According to the MB feature selection, temporal, frequency, and demographic features ranked highest in importance, while statistical ones were deemed non-significant. A comparative assessment of a generic model (trained on unclassified BP data) and specialized models (tailored to each distinct BP population), demonstrated a consistent superiority of our proposed MB feature space with a mean absolute error of $10.2 mmHg (0.28)$ for systolic BP and $6.7 mmHg (0.18)$ for diastolic BP on the whole dataset. Moreover, we present a first comparison of in-clinic vs. ambulatory models, with performance significantly lower for the latter with a drop of $2.85 mmHg$ in systolic ( $p < 0.0001$ ) and $2.82 mmHg$ for diastolic ( $p < 0.0001$ ) estimation errors. This work contributes to the resilient understanding of BP estimation algorithms from PPG signals, providing causal features in the signal and quantifying the disparities between ambulatory and in-clinic measurements.
- 10 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 28 (10) , 5768-5779
Robust Feature Selection for BP Estimation in Multiple Populations: Towards Cuffless Ambulatory BP Monitoring
Current blood pressure (BP) estimation methods have not achieved an accurate and adaptable approach for ambulatory diagnosis and monitoring applications of populations at risk of cardiovascular disease, generally due to a limited sample size. This paper introduces an algorithm for BP estimation solely reliant on photoplethysmography (PPG) signals and demographic features. It automatically obtains signal features and employs the Markov Blanket (MB) feature selection to discern informative and transmissible features, achieving a robust space adaptable to the population shift. This approach was validated with the Aurora-BP database, compromising ambulatory wearable cuffless BP measurements for over 500 individuals. After evaluating several machine-learning regression methods, Gradient Boosting emerged as the most effective. According to the MB feature selection, temporal, frequency, and demographic features ranked highest in importance, while statistical ones were deemed non-significant. A comparative assessment of a generic model (trained on unclassified BP data) and specialized models (tailored to each distinct BP population), demonstrated a consistent superiority of our proposed MB feature space with a mean absolute error of $10.2 mmHg (0.28)$ for systolic BP and $6.7 mmHg (0.18)$ for diastolic BP on the whole dataset. Moreover, we present a first comparison of in-clinic vs. ambulatory models, with performance significantly lower for the latter with a drop of $2.85 mmHg$ in systolic ( $p < 0.0001$ ) and $2.82 mmHg$ for diastolic ( $p < 0.0001$ ) estimation errors. This work contributes to the resilient understanding of BP estimation algorithms from PPG signals, providing causal features in the signal and quantifying the disparities between ambulatory and in-clinic measurements.
- Open Access
- 11 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Robust Feature Selection for Continuous BP Estimation in Multiple Populations: Towards Cuffless Ambulatory BP Monitoring
Current blood pressure (BP) estimation methods have not achieved an accurate and adaptable approach for application in populations at risk of cardiovascular disease, with generally limited sample sizes. Here, we introduce an algorithm for BP estimation solely reliant on photoplethysmography (PPG) signals and demographic features. Our approach automatically obtains signal features and employs the Markov Blanket (MB) feature selection to discern informative and transmissible features, achieving a robust space adaptable to the population shift. We validated our approach with the Aurora-BP database, compromising ambulatory wearable cuffless BP measurements for over 500 individuals. By evaluating several machine-learning regression methods, Gradient Boosting emerged as the most effective. The comparative assessment encompassed both a generic model (trained on unclassified BP data) and specialized models (tailored to each distinct BP population), with the former demonstrating consistent superiority with MAE of 10.2 mmHg (0.28) for systolic BP and 6.7 mmHg (0.18) for diastolic BP on the whole dataset. Moreover, a comparison of in-clinic and ambulatory model performance showed a significant decrease in accuracy for the latter of 2.85 mmHg in systolic (p < 0.0001, F-value = 32764.76) and 2.82 mmHg for diastolic (p < 0.0001, F-value = 65675.36) estimation errors. Our work contributes to a resilient BP estimation algorithm from PPG signals, underscoring the advantages of causal feature selection and quantifying the disparities between ambulatory and in-clinic measurements.
- 11 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Open AccessRobust Feature Selection for Continuous BP Estimation in Multiple Populations: Towards Cuffless Ambulatory BP Monitoring
Current blood pressure (BP) estimation methods have not achieved an accurate and adaptable approach for application in populations at risk of cardiovascular disease, with generally limited sample sizes. Here, we introduce an algorithm for BP estimation solely reliant on photoplethysmography (PPG) signals and demographic features. Our approach automatically obtains signal features and employs the Markov Blanket (MB) feature selection to discern informative and transmissible features, achieving a robust space adaptable to the population shift. We validated our approach with the Aurora-BP database, compromising ambulatory wearable cuffless BP measurements for over 500 individuals. By evaluating several machine-learning regression methods, Gradient Boosting emerged as the most effective. The comparative assessment encompassed both a generic model (trained on unclassified BP data) and specialized models (tailored to each distinct BP population), with the former demonstrating consistent superiority with MAE of 10.2 mmHg (0.28) for systolic BP and 6.7 mmHg (0.18) for diastolic BP on the whole dataset. Moreover, a comparison of in-clinic and ambulatory model performance showed a significant decrease in accuracy for the latter of 2.85 mmHg in systolic (p < 0.0001, F-value = 32764.76) and 2.82 mmHg for diastolic (p < 0.0001, F-value = 65675.36) estimation errors. Our work contributes to a resilient BP estimation algorithm from PPG signals, underscoring the advantages of causal feature selection and quantifying the disparities between ambulatory and in-clinic measurements.
- 1 October 2022
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 108, 103876
A new scheme for the development of IMU-based activity recognition systems for telerehabilitation
Wearable human activity recognition systems (HAR) using inertial measurement units (IMU) play a key role in the development of smart rehabilitation systems. Training of a HAR system with patient data is costly, time-consuming, and difficult for the patients. This study proposes a new scheme for the optimal design of HARs with minimal involvement of the patients. It uses healthy subject data for optimal design for a set of activities used in the rehabilitation of PD1 patients. It maintains its performance for individual PD subjects using a single session data collection and an adaptation procedure. In the optimal design, several classifiers (i.e. NM, k-NN, MLP with RBF as a hidden layer, and multistage RBF SVM) were investigated. Features were signal-based in the time, frequency, and time-frequency domains. Double-stage feature extraction by PCA and fisher technique was used. The optimal design reached a recall of 95% on healthy subjects using only two sensors on the left thigh and forearm. Implementing the adaptation procedure on two PD subjects, the performance was maintained above 80%. Post analysis on the performance of the adapted HAR showed a slight drop in precision (above 87% to above 81%) for activities that was performed in sitting condition.
- 1 October 2022
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 108, 103876
A new scheme for the development of IMU-based activity recognition systems for telerehabilitation
Wearable human activity recognition systems (HAR) using inertial measurement units (IMU) play a key role in the development of smart rehabilitation systems. Training of a HAR system with patient data is costly, time-consuming, and difficult for the patients. This study proposes a new scheme for the optimal design of HARs with minimal involvement of the patients. It uses healthy subject data for optimal design for a set of activities used in the rehabilitation of PD1 patients. It maintains its performance for individual PD subjects using a single session data collection and an adaptation procedure. In the optimal design, several classifiers (i.e. NM, k-NN, MLP with RBF as a hidden layer, and multistage RBF SVM) were investigated. Features were signal-based in the time, frequency, and time-frequency domains. Double-stage feature extraction by PCA and fisher technique was used. The optimal design reached a recall of 95% on healthy subjects using only two sensors on the left thigh and forearm. Implementing the adaptation procedure on two PD subjects, the performance was maintained above 80%. Post analysis on the performance of the adapted HAR showed a slight drop in precision (above 87% to above 81%) for activities that was performed in sitting condition.