Yi-Cheng Lo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yi-Cheng Lo has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- An-Yeu Wu
Graduate Institute of Electronics Engineering, National Taiwan University, Taipei, Taiwan
4 shared publications - Win-Ken Beh
Graduate Institute of Electronics Engineering, National Taiwan University, Taipei City 10617, Taiwan
2 shared publications - Cheng-Lin Hsieh
Computer Science and Engineering Department, University of Michigan, Ann Arbor, MI, USA
1 shared publication Chiao-Chun Huang
Electrical Engineering and the Graduate Institute of Electronics Engineering, National Taiwan University, Taipei, Taiwan
1 shared publication- Chieh-Wen Yang
Graduate Institute of Electronics Engineering, National Taiwan University, Taipei 106319, Taiwan
1 shared publication - Hao-Wei Chiang
Graduate Institute of Electronics Engineering, National Taiwan University, Taipei, Taiwan
1 shared publication
Latest Publications
- Open Access
- 26 July 2026
- Published by Association for Computing Machinery (ACM)
- p. 1-7
ChiSER: Surrogate-Enhanced Resource-aware Exploration of Chiplet-based Deep Neural Network Accelerators
- 26 July 2026
- Published by Association for Computing Machinery (ACM)
- p. 1-7
Open AccessChiSER: Surrogate-Enhanced Resource-aware Exploration of Chiplet-based Deep Neural Network Accelerators
- 9 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Internet of Things Journal
- Vol. 12 (8) , 11081-11095
EECS: Efficient End-Cloud Collaborative System With On-Demand Offloading Mechanism for Convolutional Neural Network
The end-cloud synergy with neural networks offers significant promise for enhancing AI-IoT systems. Numerous studies have been conducted to effectively address the dynamic and resource-constrained nature of IoT; however, challenges persist in adaptability to constraints, horizontal integration between technologies, and system-level optimization. In this paper, we propose an end-cloud collaborative system (EECS) with an on-demand offloading mechanism for AI-IoT. We enhance three critical areas previously narrowly explored: model pruning to fit into the end device’s constraints, dynamic data transmission between end and cloud, and an effective offloading policy. We pay particular attention to the constraints imposed by multiply-and-add (MAC) operations and bandwidth (BW) at the end, with a focus on image classification tasks. Our contributions are threefold. First, we introduce a two-stage trainable pruning method that can automatically adjust the end model to end constraints and optimize from a system-wide perspective. Second, we propose an adaptive mechanism that accommodates fluctuating bandwidth conditions based on our trainable pruning, integrating static pruning with dynamic inference. Third, we develop a smart offloading policy that enhances decision-making, thereby elevating system-level efficiency. Finally, our EECS shows substantial improvements, achieving 2.6×~4× reductions in MAC costs and 3.8×~10.4× reductions in BW costs compared to existing approaches, based on evaluations using the CIFAR-100 and Tiny-ImageNet-200 datasets.
- 9 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Internet of Things Journal
- Vol. 12 (8) , 11081-11095
EECS: Efficient End-Cloud Collaborative System With On-Demand Offloading Mechanism for Convolutional Neural Network
The end-cloud synergy with neural networks offers significant promise for enhancing AI-IoT systems. Numerous studies have been conducted to effectively address the dynamic and resource-constrained nature of IoT; however, challenges persist in adaptability to constraints, horizontal integration between technologies, and system-level optimization. In this paper, we propose an end-cloud collaborative system (EECS) with an on-demand offloading mechanism for AI-IoT. We enhance three critical areas previously narrowly explored: model pruning to fit into the end device’s constraints, dynamic data transmission between end and cloud, and an effective offloading policy. We pay particular attention to the constraints imposed by multiply-and-add (MAC) operations and bandwidth (BW) at the end, with a focus on image classification tasks. Our contributions are threefold. First, we introduce a two-stage trainable pruning method that can automatically adjust the end model to end constraints and optimize from a system-wide perspective. Second, we propose an adaptive mechanism that accommodates fluctuating bandwidth conditions based on our trainable pruning, integrating static pruning with dynamic inference. Third, we develop a smart offloading policy that enhances decision-making, thereby elevating system-level efficiency. Finally, our EECS shows substantial improvements, achieving 2.6×~4× reductions in MAC costs and 3.8×~10.4× reductions in BW costs compared to existing approaches, based on evaluations using the CIFAR-100 and Tiny-ImageNet-200 datasets.
- Open Access
An Efficient Anomalous Sound Detection System for Microcontrollers
Anomalous Sound Detection (ASD) systems are pivotal in the Industrial Internet of Things (IIoT). Through the early detection of machines’ anomalies, these systems facilitate proactive maintenance, thereby mitigating potential losses. Although prior studies have improved system accuracy using various advanced machine learning technologies, they frequently neglect the associated substantial computing and storage demands, which are crucial in resource-constrained IIoT environments. In this paper, we propose an ASD system that is efficiently optimized for both software and hardware considerations regarding edge intelligence. For the software aspect, we identify signal variation as a critical issue for ASD. Hence, we introduce a suite of lightweight yet robust processing techniques that enhance accuracy while minimizing resource consumption. As for the hardware aspect, we find that memory constraints may be a significant challenge for deploying ASD systems on microcontrollers (MCUs). Therefore, we propose a memory-aware pruning algorithm specialized for ASD to fit into MCUs’ constraints. Finally, we evaluate our method on the DCASE dataset, and the results show that our system achieves favorable outcomes in both accuracy and resource efficiency, marking our contribution to ASD system practice.
Open AccessAn Efficient Anomalous Sound Detection System for Microcontrollers
Anomalous Sound Detection (ASD) systems are pivotal in the Industrial Internet of Things (IIoT). Through the early detection of machines’ anomalies, these systems facilitate proactive maintenance, thereby mitigating potential losses. Although prior studies have improved system accuracy using various advanced machine learning technologies, they frequently neglect the associated substantial computing and storage demands, which are crucial in resource-constrained IIoT environments. In this paper, we propose an ASD system that is efficiently optimized for both software and hardware considerations regarding edge intelligence. For the software aspect, we identify signal variation as a critical issue for ASD. Hence, we introduce a suite of lightweight yet robust processing techniques that enhance accuracy while minimizing resource consumption. As for the hardware aspect, we find that memory constraints may be a significant challenge for deploying ASD systems on microcontrollers (MCUs). Therefore, we propose a memory-aware pruning algorithm specialized for ASD to fit into MCUs’ constraints. Finally, we evaluate our method on the DCASE dataset, and the results show that our system achieves favorable outcomes in both accuracy and resource efficiency, marking our contribution to ASD system practice.
- Open Access
- 18 April 2023
- Published by Association for Computing Machinery (ACM) in ACM Transactions on Computing for Healthcare
- Vol. 4 (2) , 1-20
Machine-aided PPG Signal Quality Assessment (SQA) for Multi-mode Physiological Signal Monitoring
Photoplethysmography (PPG) is a non-invasive technique for recording human vital signs. PPG is normally recorded by wearable devices that are prone to artifacts. This results in signal corruption that decreases measurement accuracy. Thus, a signal quality assessment (SQA) system is essential in obtaining reliable measurements. Conventionally, SQA is mainly driven by human-knowledge and supervised through experts’ annotations. However, they are not tailored for the particularities of the domain applications. Hence, we propose a machine-aided SQA framework that generates respective quality criteria for applications. By using the proposed approach, quality criteria can be easily trained for different applications. Then, quality assessment can be applied to several PPG-based physiological signals telemonitoring. Compared with conventional approaches, the proposed system has a higher rejection rate for high-error signals and a lower mean absolute error is achieved when estimating heart rate (-3.06 BPM), determining respiration rate (–1.36 BPM), and predicting hypertension (+24%). The proposed method enhances accuracy in monitoring physiological signals and thus is suitable for healthcare applications.
- 18 April 2023
- Published by Association for Computing Machinery (ACM) in ACM Transactions on Computing for Healthcare
- Vol. 4 (2) , 1-20
Open AccessMachine-aided PPG Signal Quality Assessment (SQA) for Multi-mode Physiological Signal Monitoring
Photoplethysmography (PPG) is a non-invasive technique for recording human vital signs. PPG is normally recorded by wearable devices that are prone to artifacts. This results in signal corruption that decreases measurement accuracy. Thus, a signal quality assessment (SQA) system is essential in obtaining reliable measurements. Conventionally, SQA is mainly driven by human-knowledge and supervised through experts’ annotations. However, they are not tailored for the particularities of the domain applications. Hence, we propose a machine-aided SQA framework that generates respective quality criteria for applications. By using the proposed approach, quality criteria can be easily trained for different applications. Then, quality assessment can be applied to several PPG-based physiological signals telemonitoring. Compared with conventional approaches, the proposed system has a higher rejection rate for high-error signals and a lower mean absolute error is achieved when estimating heart rate (-3.06 BPM), determining respiration rate (–1.36 BPM), and predicting hypertension (+24%). The proposed method enhances accuracy in monitoring physiological signals and thus is suitable for healthcare applications.
- 18 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 27 (5) , 2243-2254
Noise-Level Aware Compressed Analysis Framework for Robust Electrocardiography Signal Monitoring
Compressed sensing (CS) has drawn much attention in electrocardiography (ECG) signal monitoring for its effectiveness in reducing the transmission power of wireless sensor systems. Compressed analysis (CA) is an improved methodology to further elevate the system's efficiency by directly performing classification on the compressed data at the back-end of the monitoring system. However, conventional CA lacks of considering the effect of noise, which is an essential issue in practical applications. In this work, we observe that noise causes an accuracy drop in the previous CA framework, thus discovering that different signal-to-noise ratios (SNRs) require different sizes of CA models. We propose a two-stage noise-level aware compressed analysis framework. First, we apply the singular value decomposition to estimate the noise level in the compressed domain by projecting the received signal into the null space of the compressed ECG signal. A transfer-learning-aided algorithm is proposed to reduce the long-training-time drawback. Second, we select the optimal CA model dynamically based on the estimated SNR. The CA model will use a predictive dictionary to extract features from the ECG signal, and then imposes a linear classifier for classification. A weight-sharing training mechanism is proposed to enable parameter sharing among the pre-trained models, thus significantly reducing storage overhead. Lastly, we validate our framework on the atrial fibrillation ECG signal detection on the NTUH and MIT-BIH datasets. We show improvement in the accuracy of 6.4% and 7.7% in the low SNR condition over the state-of-the-art CA framework.
- 18 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 27 (5) , 2243-2254
Noise-Level Aware Compressed Analysis Framework for Robust Electrocardiography Signal Monitoring
Compressed sensing (CS) has drawn much attention in electrocardiography (ECG) signal monitoring for its effectiveness in reducing the transmission power of wireless sensor systems. Compressed analysis (CA) is an improved methodology to further elevate the system's efficiency by directly performing classification on the compressed data at the back-end of the monitoring system. However, conventional CA lacks of considering the effect of noise, which is an essential issue in practical applications. In this work, we observe that noise causes an accuracy drop in the previous CA framework, thus discovering that different signal-to-noise ratios (SNRs) require different sizes of CA models. We propose a two-stage noise-level aware compressed analysis framework. First, we apply the singular value decomposition to estimate the noise level in the compressed domain by projecting the received signal into the null space of the compressed ECG signal. A transfer-learning-aided algorithm is proposed to reduce the long-training-time drawback. Second, we select the optimal CA model dynamically based on the estimated SNR. The CA model will use a predictive dictionary to extract features from the ECG signal, and then imposes a linear classifier for classification. A weight-sharing training mechanism is proposed to enable parameter sharing among the pre-trained models, thus significantly reducing storage overhead. Lastly, we validate our framework on the atrial fibrillation ECG signal detection on the NTUH and MIT-BIH datasets. We show improvement in the accuracy of 6.4% and 7.7% in the low SNR condition over the state-of-the-art CA framework.