Luke Turley
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Luke Turley has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Angel R. Thomas
Curtin Medical School, Faculty of Health Sciences, Curtin University, Perth, AUS
2 shared publications Eoin Sheehan
Department of Orthopaedics, Midland Regional Hospital Tullamore, Tullamore, Ireland
2 shared publications- Ian Patrick Barry
Department of Vascular Surgery, Fiona Stanley Hospital, Perth, WA, Australia
2 shared publications - Mariah T. Mwipatayi
Medicine, University of Buckingham Medical School, Buckingham, GBR
2 shared publications - Ailbhe White-Gibson
Department Trauma & Orthopaedics, Tallaght University Hospital, Dublin, Ireland
1 shared publication - Bibombe P. Mwipatayi
Vascular Surgery, Royal Perth Hospital, Perth, AUS
1 shared publication
Latest Publications
- Open Access
- 20 January 2024
- Published by Elsevier in Brain and Spine
- Vol. 4, 102748
The efficacy of anchored stand-alone spacers in comparison to conventional cage and plate in anterior cervical discectomy and fusion surgery: A meta-analysis of randomised controlled trials for clinical and radiological outcomes
- 20 January 2024
- Published by Elsevier in Brain and Spine
- Vol. 4, 102748
Open AccessThe efficacy of anchored stand-alone spacers in comparison to conventional cage and plate in anterior cervical discectomy and fusion surgery: A meta-analysis of randomised controlled trials for clinical and radiological outcomes
- Open Access
- 1 February 2023
- Published by Bioscientifica in EFORT Open Reviews
- Vol. 8 (2) , 90-99
Frequency of complications in intramedullary nailing of open tibial shaft fractures: a systematic review
Background: Open tibial shaft fractures comprise almost 45% of all open fractures and are frequently the result of high-energy trauma. Due to contamination, limited soft tissue coverage of the tibial shaft and poor tibial blood supply, open tibial shaft fractures are associated with high rates of complication including malunion, non-union and infection. Intramedullary nailing (IMN) is a mainstay of treatment. This study aims to determine the frequency of the various complications in this cohort. Methods: A systematic review of papers published on Embase, PubMed and Cochrane databases pertaining to the use of IMN to fix open tibial shaft fractures were included. The available evidence was collated in regard to the incidence of union, malunion, non-union and infection seen in this cohort. Results: A total of 2767 citations were reviewed, and 17 studies comprising 1850 patients were included in the analysis. There was a delayed union rate of 22.4%, malunion rate of 8.3%, non-union rate of 9.7% and infection rate of 8.1% (95% CI: 5.7%–10.8%) in this patient cohort. Subgroup analysis showed a 3-fold increase in non-union and a 2-fold increase in deep infection among Gustilo III injuries compared to Gustilo I and II. Conclusions: IMN for open tibial shaft fractures results in high rates of union and low rates of infection, comparable to figures seen in closed injuries and superior to those seen with alternative methods of fixation. There is a substantially increased risk of complication associated with Gustilo III injuries, reinforcing the significance of the soft tissue injury in these patients.
- 1 February 2023
- Published by Bioscientifica in EFORT Open Reviews
- Vol. 8 (2) , 90-99
Open AccessFrequency of complications in intramedullary nailing of open tibial shaft fractures: a systematic review
Background: Open tibial shaft fractures comprise almost 45% of all open fractures and are frequently the result of high-energy trauma. Due to contamination, limited soft tissue coverage of the tibial shaft and poor tibial blood supply, open tibial shaft fractures are associated with high rates of complication including malunion, non-union and infection. Intramedullary nailing (IMN) is a mainstay of treatment. This study aims to determine the frequency of the various complications in this cohort. Methods: A systematic review of papers published on Embase, PubMed and Cochrane databases pertaining to the use of IMN to fix open tibial shaft fractures were included. The available evidence was collated in regard to the incidence of union, malunion, non-union and infection seen in this cohort. Results: A total of 2767 citations were reviewed, and 17 studies comprising 1850 patients were included in the analysis. There was a delayed union rate of 22.4%, malunion rate of 8.3%, non-union rate of 9.7% and infection rate of 8.1% (95% CI: 5.7%–10.8%) in this patient cohort. Subgroup analysis showed a 3-fold increase in non-union and a 2-fold increase in deep infection among Gustilo III injuries compared to Gustilo I and II. Conclusions: IMN for open tibial shaft fractures results in high rates of union and low rates of infection, comparable to figures seen in closed injuries and superior to those seen with alternative methods of fixation. There is a substantially increased risk of complication associated with Gustilo III injuries, reinforcing the significance of the soft tissue injury in these patients.
- Open Access
- 4 January 2023
- Published by AVES YAYINCILIK A.Ş. in Acta Orthopaedica et Traumatologica Turcica
- Vol. 57 (4) , 176-182
Pronator quadratus repair after volar plating for distal radius fractures: A systematic review and meta-analysis of randomized controlled trials
Objective: The purpose of the current study is to meta-analyze the randomized controlled trials in the literature comparing pronator quadratus repair versus no repair alongside volar plating of distal radius fractures. Methods: A search of the PUBMED/MEDLINE, EMBASE, and The Cochrane Library databases was performed. Any randomized con- trolled trials comparing pronator quadratus repair versus no repair alongside volar plating of distal radius fractures were included. The relevant information was collected by 2 blinded reviewers using a predetermined data sheet. Clinical outcomes were compared, with all statistical analyses performed using Review Manager Version 5.3. Results: Five randomized controlled trials with 273 patients were included. There was no significant difference in the range of motion in flexion-extension, ulnar-radial deviation, or pronation-supination. There was a significant difference in favor of the no repair group for Disabilities of the Arm, Shoulder and Hand (DASH) Score (MD [Mean Difference]: 2.63, P < .0001) and pronation strength (MD: 13, P < .0001). Furthermore, there was no significant difference in the visual analog scale score. There were 3 complications relating to pronator quadratus repair, in which patients developed carpal tunnel syndrome requiring a release. There was no significant difference in the re-operation rate. Conclusion: This study found that pronator quadratus repair when performing volar plating for distal radius fractures did not result in a significant improvement in functional outcome, range of motion, or strength. Level of Evidence: I, Systematic Review of Level 1 Studies, Level I, Therapeutic Study Cite this article as: Turley LP, Hurley ET, White-Gibson A, Clesham K, Lyons F. Pronator quadratus repair after volar plating for distal radius fractures: A systematic review and meta-analysis of randomized controlled trials. Acta Orthop Traumatol Turc., 2023;57(4):176-182.
- 4 January 2023
- Published by AVES YAYINCILIK A.Ş. in Acta Orthopaedica et Traumatologica Turcica
- Vol. 57 (4) , 176-182
Open AccessPronator quadratus repair after volar plating for distal radius fractures: A systematic review and meta-analysis of randomized controlled trials
Objective: The purpose of the current study is to meta-analyze the randomized controlled trials in the literature comparing pronator quadratus repair versus no repair alongside volar plating of distal radius fractures. Methods: A search of the PUBMED/MEDLINE, EMBASE, and The Cochrane Library databases was performed. Any randomized con- trolled trials comparing pronator quadratus repair versus no repair alongside volar plating of distal radius fractures were included. The relevant information was collected by 2 blinded reviewers using a predetermined data sheet. Clinical outcomes were compared, with all statistical analyses performed using Review Manager Version 5.3. Results: Five randomized controlled trials with 273 patients were included. There was no significant difference in the range of motion in flexion-extension, ulnar-radial deviation, or pronation-supination. There was a significant difference in favor of the no repair group for Disabilities of the Arm, Shoulder and Hand (DASH) Score (MD [Mean Difference]: 2.63, P < .0001) and pronation strength (MD: 13, P < .0001). Furthermore, there was no significant difference in the visual analog scale score. There were 3 complications relating to pronator quadratus repair, in which patients developed carpal tunnel syndrome requiring a release. There was no significant difference in the re-operation rate. Conclusion: This study found that pronator quadratus repair when performing volar plating for distal radius fractures did not result in a significant improvement in functional outcome, range of motion, or strength. Level of Evidence: I, Systematic Review of Level 1 Studies, Level I, Therapeutic Study Cite this article as: Turley LP, Hurley ET, White-Gibson A, Clesham K, Lyons F. Pronator quadratus repair after volar plating for distal radius fractures: A systematic review and meta-analysis of randomized controlled trials. Acta Orthop Traumatol Turc., 2023;57(4):176-182.
- Open Access
- 18 November 2022
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 3 (11) , 907-912
Whole-body radiation exposure in Trauma and Orthopaedic surgery
Aims: The use of fluoroscopy in orthopaedic surgery creates risk of radiation exposure to surgeons. Appropriate personal protective equipment (PPE) can help mitigate this. The primary aim of this study was to assess if current radiation protection in orthopaedic trauma is safe. The secondary aims were to describe normative data of radiation exposure during common orthopaedic procedures, evaluate ways to improve any deficits in protection, and validate the use of electronic personal dosimeters (EPDs) in assessing radiation dose in orthopaedic surgery. Methods: Radiation exposure to surgeons during common orthopaedic trauma operations was prospectively assessed using EPDs and thermoluminescent dosimeters (TLDs). Normative data for each operation type were calculated and compared to recommended guidelines. Results: Current PPE appears to mitigate more than 90% of ionizing radiation in orthopaedic fluoroscopic procedures. There is a higher exposure to the inner thigh during seated procedures. EPDs provided results for individual procedures. Conclusion: PPE currently used by surgeons in orthopaedic trauma theatre adequately reduces radiation exposure to below recommended levels. Normative data per trauma case show specific anatomical areas of higher exposure, which may benefit from enhanced radiation protection. EPDs can be used to assess real-time radiation exposure in orthopaedic surgery. There may be a role in future medical wearables for orthopaedic surgeons. Cite this article: Bone Jt Open 2022;3(11):907–912.
- 18 November 2022
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 3 (11) , 907-912
Open AccessWhole-body radiation exposure in Trauma and Orthopaedic surgery
Aims: The use of fluoroscopy in orthopaedic surgery creates risk of radiation exposure to surgeons. Appropriate personal protective equipment (PPE) can help mitigate this. The primary aim of this study was to assess if current radiation protection in orthopaedic trauma is safe. The secondary aims were to describe normative data of radiation exposure during common orthopaedic procedures, evaluate ways to improve any deficits in protection, and validate the use of electronic personal dosimeters (EPDs) in assessing radiation dose in orthopaedic surgery. Methods: Radiation exposure to surgeons during common orthopaedic trauma operations was prospectively assessed using EPDs and thermoluminescent dosimeters (TLDs). Normative data for each operation type were calculated and compared to recommended guidelines. Results: Current PPE appears to mitigate more than 90% of ionizing radiation in orthopaedic fluoroscopic procedures. There is a higher exposure to the inner thigh during seated procedures. EPDs provided results for individual procedures. Conclusion: PPE currently used by surgeons in orthopaedic trauma theatre adequately reduces radiation exposure to below recommended levels. Normative data per trauma case show specific anatomical areas of higher exposure, which may benefit from enhanced radiation protection. EPDs can be used to assess real-time radiation exposure in orthopaedic surgery. There may be a role in future medical wearables for orthopaedic surgeons. Cite this article: Bone Jt Open 2022;3(11):907–912.
- 23 August 2022
- Published by Springer Nature in Irish Journal of Medical Science (1971 -)
- Vol. 192 (3) , 1225-1229
‘Out of hours’ orthopaedics in an Irish regional trauma unit and the impact of COVID-19
Introduction MRHT is the regional trauma service for the Midlands, providing 24/7 orthopaedic cover. ‘Out of hours’ surgery is reserved for those occasions where waiting for the next operating list during normal working hours would result in an unacceptable outcome for the patient. Aims To identify how many ‘out-of-hours’ surgeries were performed and what proportion of the total workload was made up by these cases. Secondly, to identify the impact of COVID-19 on our workload as an acute trauma service. Methods We performed a retrospective analysis of all operations performed in the emergency orthopaedic theatre between January 2017 and October 2020. Included were all emergency orthopaedic procedures performed after 6 p.m. and before 8 a.m. We compared this to the total number of trauma surgeries performed in the same time period to calculate the percentage of our total operations. Results There were a total of 7615 orthopaedic trauma operations performed in the 193 weeks. 164 of these were ‘out-of-hours’. This represents 2.2% of the total operations performed and is equal to 0.84 cases per week. 55 of the 164 (33.5%) were performed in children under the age of 18. 62 were performed between 6 and 8 p.m., 61 between 8 and 10 p. m., 31 between 10 p.m. and midnight, and the remaining 10 were performed between midnight and 3 a.m. Conclusion Surgery out of hours has been associated with increased complications, and so decisions to perform emergency surgery should not be made lightly. However, sometimes they are unfortunately necessary and are some of the most important operations we can perform as orthopaedic surgeons.
- 23 August 2022
- Published by Springer Nature in Irish Journal of Medical Science (1971 -)
- Vol. 192 (3) , 1225-1229
‘Out of hours’ orthopaedics in an Irish regional trauma unit and the impact of COVID-19
Introduction MRHT is the regional trauma service for the Midlands, providing 24/7 orthopaedic cover. ‘Out of hours’ surgery is reserved for those occasions where waiting for the next operating list during normal working hours would result in an unacceptable outcome for the patient. Aims To identify how many ‘out-of-hours’ surgeries were performed and what proportion of the total workload was made up by these cases. Secondly, to identify the impact of COVID-19 on our workload as an acute trauma service. Methods We performed a retrospective analysis of all operations performed in the emergency orthopaedic theatre between January 2017 and October 2020. Included were all emergency orthopaedic procedures performed after 6 p.m. and before 8 a.m. We compared this to the total number of trauma surgeries performed in the same time period to calculate the percentage of our total operations. Results There were a total of 7615 orthopaedic trauma operations performed in the 193 weeks. 164 of these were ‘out-of-hours’. This represents 2.2% of the total operations performed and is equal to 0.84 cases per week. 55 of the 164 (33.5%) were performed in children under the age of 18. 62 were performed between 6 and 8 p.m., 61 between 8 and 10 p. m., 31 between 10 p.m. and midnight, and the remaining 10 were performed between midnight and 3 a.m. Conclusion Surgery out of hours has been associated with increased complications, and so decisions to perform emergency surgery should not be made lightly. However, sometimes they are unfortunately necessary and are some of the most important operations we can perform as orthopaedic surgeons.
- Open Access
- 4 May 2021
- Published by Springer Nature in Cureus
- Vol. 13 (5)
The Impact of Endograft Selection on Outcomes Following Treatment Outside of Instructions for Use (IFU) in Endovascular Abdominal Aortic Aneurysm Repair (EVAR)
Endovascular aneurysm repair (EVAR) has become the treatment modality of choice in patients with abdominal aortic aneurysms. This has resulted in endograft utilization within instructions for use (IFU) and in cases with proximal neck anatomy outside of IFU. To identify whether graft selection influences outcomes following EVAR outside of IFU. A retrospective analysis was conducted from previously published data for 636 patients, collated from the Endurant Stent Graft Natural Selection Global Post-Market Registry (ENGAGE) and the Global Registry for Endovascular Aortic Treatment (GREAT). Patients were recruited into the ENGAGE registry between 2009 and 2011 and into the GREAT registry between August 2010 and October 2016. In ENGAGE, they received the Medtronic Endurant stent graft (Medtronic Vascular Inc, Dublin, Ireland) for infrarenal AAA repair while patients analyzed in GREAT received the Gore Excluder stent-graft (W. L. Gore & Associates, Flagstaff, Arizona). Analyses were performed to evaluate all-cause mortality, aneurysm-related mortality, endoleak occurrence, and surgical reintervention rates between the two cohorts. Of the 636 patients, 225 were from ENGAGE (mean age 73 years) and 411 were from GREAT (mean age 75 years). 17.8% were treated outside of IFU in the ENGAGE registry, while 12.4% were treated outside IFU in the GREAT cohort. Five-year freedom from all-cause mortality was similar in both cohorts (65.6% vs. 63.8%). The rate of type IA endoleak development was lower in the Excluder cohort, although this may have been impacted by the fact that only endoleaks that underwent reintervention were recorded within GREAT analysis (Endurant 10.6% vs. Excluder 7.0%). The reintervention rate was 16% at five years following the Endurant aortic graft while it was 13.3% at five years with the Excluder. Treatment outside of IFU, be it with a suprarenal or an infrarenal fixation device, is associated with worse outcomes. This analysis reinforces the importance of the consideration of either fenestrated or open repair in those aneurysms that fail to satisfy IFU while endovascular repair in such a setting should be reserved as a last resort strategy.
- 4 May 2021
- Published by Springer Nature in Cureus
- Vol. 13 (5)
Open AccessThe Impact of Endograft Selection on Outcomes Following Treatment Outside of Instructions for Use (IFU) in Endovascular Abdominal Aortic Aneurysm Repair (EVAR)
Endovascular aneurysm repair (EVAR) has become the treatment modality of choice in patients with abdominal aortic aneurysms. This has resulted in endograft utilization within instructions for use (IFU) and in cases with proximal neck anatomy outside of IFU. To identify whether graft selection influences outcomes following EVAR outside of IFU. A retrospective analysis was conducted from previously published data for 636 patients, collated from the Endurant Stent Graft Natural Selection Global Post-Market Registry (ENGAGE) and the Global Registry for Endovascular Aortic Treatment (GREAT). Patients were recruited into the ENGAGE registry between 2009 and 2011 and into the GREAT registry between August 2010 and October 2016. In ENGAGE, they received the Medtronic Endurant stent graft (Medtronic Vascular Inc, Dublin, Ireland) for infrarenal AAA repair while patients analyzed in GREAT received the Gore Excluder stent-graft (W. L. Gore & Associates, Flagstaff, Arizona). Analyses were performed to evaluate all-cause mortality, aneurysm-related mortality, endoleak occurrence, and surgical reintervention rates between the two cohorts. Of the 636 patients, 225 were from ENGAGE (mean age 73 years) and 411 were from GREAT (mean age 75 years). 17.8% were treated outside of IFU in the ENGAGE registry, while 12.4% were treated outside IFU in the GREAT cohort. Five-year freedom from all-cause mortality was similar in both cohorts (65.6% vs. 63.8%). The rate of type IA endoleak development was lower in the Excluder cohort, although this may have been impacted by the fact that only endoleaks that underwent reintervention were recorded within GREAT analysis (Endurant 10.6% vs. Excluder 7.0%). The reintervention rate was 16% at five years following the Endurant aortic graft while it was 13.3% at five years with the Excluder. Treatment outside of IFU, be it with a suprarenal or an infrarenal fixation device, is associated with worse outcomes. This analysis reinforces the importance of the consideration of either fenestrated or open repair in those aneurysms that fail to satisfy IFU while endovascular repair in such a setting should be reserved as a last resort strategy.
- Open Access
- 20 April 2021
- Published by Springer Nature in Cureus
- Vol. 13 (4)
The Impact of Endograft Selection on Mid-Term Outcomes in Female Patients Following Endovascular Aortic Aneurysm Repair (EVAR) for Abdominal Aortic Aneurysm (AAA)
Abdominal aortic aneurysms (AAA) are far more common in male than female gender, although they appear to have a more aggressive pathophysiology in females. Given the lower incidence of AAA in females, it has been difficult to assess the impact of graft selection for endovascular aortic aneurysm repair (EVAR) in this cohort. To identify whether graft selection influences outcomes following AAA endoluminal repair in female patients. A retrospective analysis of published data for 711 female patients was conducted, collating data from three cohorts - Endurant Stent Graft Natural Selection Global post-market registry (ENGAGE), Global Registry for Endovascular Aortic Treatment (GREAT) and U.S. Zenith multicenter trial in combination with the Zenith female registry. Patients were recruited into the ENGAGE registry between 2009 and 2011, the GREAT registry between August 2010 and October 2016, and into the Zenith registry between 2000 and 2003. Patients from ENGAGE received the Medtronic Endurant stent graft for infrarenal AAA repair, patients analysed in GREAT received the Gore Excluder stent graft and the Zenith group received the Cook Zenith stent graft. Analyses were performed to evaluate all-cause mortality, aorta-related mortality, endoleak occurrence and surgical reintervention rates between the three cohorts. Of the 711 females, 133 were from ENGAGE (mean age 76 years), 538 were from GREAT (mean age 75 years) and 40 were from Zenith (mean age 74 years). The rates of co-morbidities between the three groups were broadly similar except for atherosclerotic disease which was more commonly observed in those treated with the GORE Excluder. The rate of endoleaks was lower when the Excluder stent was utilised as compared to the other two stents (Excluder 6.7% vs. Zenith 12.5% vs. Endurant 35.3%) even considering the limited follow-up of the Zenith group to two years as compared to five years for both ENGAGE and GREAT. All-cause mortality was similar in all three groups across the period examined while aorta-related mortality was uncommon. Reintervention rate was 15% at two years following the utilisation of the Zenith aortic graft while the rate of intervention at five years was broadly similar between ENGAGE and GREAT. The newer generation, lower profile aortic endografts appear to have provided a safe and successful tool in the management of AAA in female patients, despite more complex aortic anatomy with shorter infrarenal neck length and larger aortic neck angulation.
- 20 April 2021
- Published by Springer Nature in Cureus
- Vol. 13 (4)
Open AccessThe Impact of Endograft Selection on Mid-Term Outcomes in Female Patients Following Endovascular Aortic Aneurysm Repair (EVAR) for Abdominal Aortic Aneurysm (AAA)
Abdominal aortic aneurysms (AAA) are far more common in male than female gender, although they appear to have a more aggressive pathophysiology in females. Given the lower incidence of AAA in females, it has been difficult to assess the impact of graft selection for endovascular aortic aneurysm repair (EVAR) in this cohort. To identify whether graft selection influences outcomes following AAA endoluminal repair in female patients. A retrospective analysis of published data for 711 female patients was conducted, collating data from three cohorts - Endurant Stent Graft Natural Selection Global post-market registry (ENGAGE), Global Registry for Endovascular Aortic Treatment (GREAT) and U.S. Zenith multicenter trial in combination with the Zenith female registry. Patients were recruited into the ENGAGE registry between 2009 and 2011, the GREAT registry between August 2010 and October 2016, and into the Zenith registry between 2000 and 2003. Patients from ENGAGE received the Medtronic Endurant stent graft for infrarenal AAA repair, patients analysed in GREAT received the Gore Excluder stent graft and the Zenith group received the Cook Zenith stent graft. Analyses were performed to evaluate all-cause mortality, aorta-related mortality, endoleak occurrence and surgical reintervention rates between the three cohorts. Of the 711 females, 133 were from ENGAGE (mean age 76 years), 538 were from GREAT (mean age 75 years) and 40 were from Zenith (mean age 74 years). The rates of co-morbidities between the three groups were broadly similar except for atherosclerotic disease which was more commonly observed in those treated with the GORE Excluder. The rate of endoleaks was lower when the Excluder stent was utilised as compared to the other two stents (Excluder 6.7% vs. Zenith 12.5% vs. Endurant 35.3%) even considering the limited follow-up of the Zenith group to two years as compared to five years for both ENGAGE and GREAT. All-cause mortality was similar in all three groups across the period examined while aorta-related mortality was uncommon. Reintervention rate was 15% at two years following the utilisation of the Zenith aortic graft while the rate of intervention at five years was broadly similar between ENGAGE and GREAT. The newer generation, lower profile aortic endografts appear to have provided a safe and successful tool in the management of AAA in female patients, despite more complex aortic anatomy with shorter infrarenal neck length and larger aortic neck angulation.