A. Daniel Davidar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
A. Daniel Davidar has a total of 70 co-authors. Here are the top co-authors by number of shared publications:
- Nicholas Theodore
Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, USA
11 shared publications - Carly Weber-Levine
Department of Neurosurgery, Johns Hopkins University School of Medicine, Baltimore, MD, USA
8 shared publications - Andrew M. Hersh
Department of Neurosurgery, Johns Hopkins University School of Medicine, Baltimore, MD, USA
7 shared publications - Kelly Jiang
HEPIUS Innovation Laboratory, School of Medicine, Johns Hopkins University, Baltimore, MD, USA
4 shared publications - Meghana Bhimreddy
Department of Neurosurgery, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
4 shared publications - Arjun Kumar Menta
HEPIUS Innovation Laboratory, School of Medicine, Johns Hopkins University, Baltimore, MD, USA
3 shared publications
Latest Publications
- 14 April 2026
- Published by Elsevier in Journal of Surgical Education
- Vol. 83  (6) , 103958
Objective Pupillometry and Dexterity Assessment in Surgical Trainees: A Pilot Study
- 14 April 2026
- Published by Elsevier in Journal of Surgical Education
- Vol. 83  (6) , 103958
Objective Pupillometry and Dexterity Assessment in Surgical Trainees: A Pilot Study
- 14 February 2025
- Published by Wolters Kluwer Health in Neurosurgery
- Vol. 96  (3S) , S94-S102
Beyond Pedicle Screw Placement: Future Minimally Invasive Applications of Robotics in Spine Surgery
Advancements in spine surgery have dramatically enhanced minimally invasive techniques, prominently through integrating robotic systems. Although pedicle screw placement remains the most widespread application of this technology, new developments are emerging to create innovative future avenues for these tools. This review explores the promising applications of robotic technology in minimally invasive spinal procedures, ranging from assistance with laminectomies and vertebroplasty to pain management and treatment of spinal tumors. We also discuss the potential for integrating artificial intelligence and augmented reality with robotic systems. If the current trajectory of research and innovation continues, there is promise in creating fully autonomous robotic systems that can revolutionize spine surgery by processing, planning, and performing procedures without heavy reliance on the surgeon.
- 14 February 2025
- Published by Wolters Kluwer Health in Neurosurgery
- Vol. 96  (3S) , S94-S102
Beyond Pedicle Screw Placement: Future Minimally Invasive Applications of Robotics in Spine Surgery
Advancements in spine surgery have dramatically enhanced minimally invasive techniques, prominently through integrating robotic systems. Although pedicle screw placement remains the most widespread application of this technology, new developments are emerging to create innovative future avenues for these tools. This review explores the promising applications of robotic technology in minimally invasive spinal procedures, ranging from assistance with laminectomies and vertebroplasty to pain management and treatment of spinal tumors. We also discuss the potential for integrating artificial intelligence and augmented reality with robotic systems. If the current trajectory of research and innovation continues, there is promise in creating fully autonomous robotic systems that can revolutionize spine surgery by processing, planning, and performing procedures without heavy reliance on the surgeon.
- 28 November 2024
- Published by Elsevier in The Spine Journal
- Vol. 25  (5) , 863-875
Sacroiliitis: current imaging modalities and future directions: a narrative review
- 28 November 2024
- Published by Elsevier in The Spine Journal
- Vol. 25  (5) , 863-875
Sacroiliitis: current imaging modalities and future directions: a narrative review
- Open Access
- 26 November 2024
- Published by International Journal of Spine Surgery in International Journal of Spine Surgery
- Vol. 18  (6) , 712-720
Accuracy of Pedicle Screw Placement Using the ExcelsiusGPS Robotic Navigation Platform: An Analysis of 728 Screws
Background Robotic platforms have increased in sophistication for pedicle screw placement. Here, we review our institutional experience using ExcelsiusGPS to assess the accuracy rate of pedicle screw placement throughout the spine and characterize predictors of placement inaccuracy. Study Design Retrospective cohort study. Methods Patients from 2017 to 2022 undergoing spinal fusion surgery with ExelsiusGPS-assisted screw implantation at a single tertiary center were retrospectively identified. Patient demographics, preoperative symptoms, and operative details were collected. Postoperative computed tomography was used to classify screw placement accuracy according to the Gertzbein and Robbins scale (GRS). A stepwise multivariable ordered logistic regression analysis determined independent risk factors for clinically inaccurate screws (GRS C/D/E). Results One hundred and seventeen patients were included. Mean age was 60.6 ± 13.2 years, with 57% men, 72% white, and mean body mass index of 29.9 ± 6.4 kg/m2. Seven hundred and twenty-eight screws were placed, predominantly in the thoracic (29.5%) and lumbar (52.6%) regions. Accuracy classification indicated 670 GRS A, 31 GRS B, 22 GRS C, 4 GRS D, and 1 GRS E screws. The clinically acceptable screw placement rate (GRS A/B) was 96%. Male gender (odds ratio [OR]: 2.12, P = 0.03), revision surgery (OR: 2.43, P = 0.02), and thoracic level screw insertion (OR: 2.33, P = 0.01) were independently associated with inaccurate screw placement and explained 8.7% of the variability seen. Of the 728 screws placed, 3 required revision after postoperative imaging revealed loosening or pedicle breach. Conclusion ExcelsiusGPS-assisted screw insertion has high placement accuracy and low revision rates. Identification of predictors of inaccuracy illustrates that similar variables, such as placement in the thoracic spine and revision surgery status, apply to both freehand and robotic screw placement. Clinical Relevance Robotic spine surgery is an accurate, reliable tool that can improve patient outcomes. Factors like male gender, thoracic screw placement, and revision surgery status are associated with lower screw placement accuracy, and these factors should inform surgical decision-making when using robotic assistance. Level of Evidence 4.
- 26 November 2024
- Published by International Journal of Spine Surgery in International Journal of Spine Surgery
- Vol. 18  (6) , 712-720
Open AccessAccuracy of Pedicle Screw Placement Using the ExcelsiusGPS Robotic Navigation Platform: An Analysis of 728 Screws
Background Robotic platforms have increased in sophistication for pedicle screw placement. Here, we review our institutional experience using ExcelsiusGPS to assess the accuracy rate of pedicle screw placement throughout the spine and characterize predictors of placement inaccuracy. Study Design Retrospective cohort study. Methods Patients from 2017 to 2022 undergoing spinal fusion surgery with ExelsiusGPS-assisted screw implantation at a single tertiary center were retrospectively identified. Patient demographics, preoperative symptoms, and operative details were collected. Postoperative computed tomography was used to classify screw placement accuracy according to the Gertzbein and Robbins scale (GRS). A stepwise multivariable ordered logistic regression analysis determined independent risk factors for clinically inaccurate screws (GRS C/D/E). Results One hundred and seventeen patients were included. Mean age was 60.6 ± 13.2 years, with 57% men, 72% white, and mean body mass index of 29.9 ± 6.4 kg/m2. Seven hundred and twenty-eight screws were placed, predominantly in the thoracic (29.5%) and lumbar (52.6%) regions. Accuracy classification indicated 670 GRS A, 31 GRS B, 22 GRS C, 4 GRS D, and 1 GRS E screws. The clinically acceptable screw placement rate (GRS A/B) was 96%. Male gender (odds ratio [OR]: 2.12, P = 0.03), revision surgery (OR: 2.43, P = 0.02), and thoracic level screw insertion (OR: 2.33, P = 0.01) were independently associated with inaccurate screw placement and explained 8.7% of the variability seen. Of the 728 screws placed, 3 required revision after postoperative imaging revealed loosening or pedicle breach. Conclusion ExcelsiusGPS-assisted screw insertion has high placement accuracy and low revision rates. Identification of predictors of inaccuracy illustrates that similar variables, such as placement in the thoracic spine and revision surgery status, apply to both freehand and robotic screw placement. Clinical Relevance Robotic spine surgery is an accurate, reliable tool that can improve patient outcomes. Factors like male gender, thoracic screw placement, and revision surgery status are associated with lower screw placement accuracy, and these factors should inform surgical decision-making when using robotic assistance. Level of Evidence 4.
- Open Access
- 12 October 2024
- Published by OAE Publishing Inc. in Artificial Intelligence Surgery
- Vol. 4  (4) , 288-95
Navigating artificial intelligence in spine surgery: implementation and optimization across the care continuum
The field of spine surgery has long been characterized by innovations and technological advancements. The integration of artificial intelligence (AI) into spine surgery represents one of the latest technical developments in the field. The ability of AI to rapidly analyze datasets improves decision making, risk assessment, intraoperative precision, and postoperative management, all of which contribute to increasing personalized spine care and improving outcomes. However, the successful implementation of AI faces regulatory and privacy challenges that must be addressed before its full potential can be realized. Here, we provide a detailed analysis of the current applications and future prospects of AI in spine surgery, highlighting both the opportunities and challenges in this evolving field.
- 12 October 2024
- Published by OAE Publishing Inc. in Artificial Intelligence Surgery
- Vol. 4  (4) , 288-95
Open AccessNavigating artificial intelligence in spine surgery: implementation and optimization across the care continuum
The field of spine surgery has long been characterized by innovations and technological advancements. The integration of artificial intelligence (AI) into spine surgery represents one of the latest technical developments in the field. The ability of AI to rapidly analyze datasets improves decision making, risk assessment, intraoperative precision, and postoperative management, all of which contribute to increasing personalized spine care and improving outcomes. However, the successful implementation of AI faces regulatory and privacy challenges that must be addressed before its full potential can be realized. Here, we provide a detailed analysis of the current applications and future prospects of AI in spine surgery, highlighting both the opportunities and challenges in this evolving field.
- 26 June 2024
- Published by Wolters Kluwer Health in Neurosurgery
- Vol. 95  (3) , e83-e84
Letter: What is the Marginal Cost of Using Robot Assistance or Navigation for Transforaminal Lumbar Interbody Fusion? A Time-Driven Activity-Based Cost Analysis
- 26 June 2024
- Published by Wolters Kluwer Health in Neurosurgery
- Vol. 95  (3) , e83-e84
Letter: What is the Marginal Cost of Using Robot Assistance or Navigation for Transforaminal Lumbar Interbody Fusion? A Time-Driven Activity-Based Cost Analysis
- 13 June 2024
- Published by Elsevier in Clinical Neurology and Neurosurgery
- Vol. 243, 108393
Robotic assisted surgery for the treatment of spinal metastases: A case series
- 13 June 2024
- Published by Elsevier in Clinical Neurology and Neurosurgery
- Vol. 243, 108393
Robotic assisted surgery for the treatment of spinal metastases: A case series
- Open Access
- 9 April 2024
- Published by Elsevier in North American Spine Society Journal (NASSJ)
- Vol. 18, 100323
Synthesis and evaluation of a novel vancomycin-infused, biomimetic bone graft using a rat model of spinal implant-associated infection
- 9 April 2024
- Published by Elsevier in North American Spine Society Journal (NASSJ)
- Vol. 18, 100323
Open AccessSynthesis and evaluation of a novel vancomycin-infused, biomimetic bone graft using a rat model of spinal implant-associated infection
- 26 December 2023
- Published by Elsevier in World Neurosurgery
- Vol. 184, 283-292.e3
Exoscope Use in Spine Surgery: A Systematic Review of Applications, Benefits, and Limitations
- 26 December 2023
- Published by Elsevier in World Neurosurgery
- Vol. 184, 283-292.e3
Exoscope Use in Spine Surgery: A Systematic Review of Applications, Benefits, and Limitations