HWHongmei Wang

Hongmei Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hongmei Wang has a total of 30 co-authors. Here are the top co-authors by number of shared publications:

  • Yezhou Chen

    Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences

    3 shared publications
  • Jingjing Tian

    Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences

    2 shared publications
  • Shaohua Ding

    CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences. No. 88, Keling Road, Suzhou New District, Jiangsu Province, 215163, China; Jihua Laboratory, Foshan, China

    2 shared publications
  • Shengbao Duan

    CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences. No. 88, Keling Road, Suzhou New District, Jiangsu Province, 215163, China; Jihua Laboratory, Foshan, China

    2 shared publications
  • Yong Li

    CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences. No. 88, Keling Road, Suzhou New District, Jiangsu Province, 215163, China; Jihua Laboratory, Foshan, China

    2 shared publications
  • Chun Zhang

    Chinese Acad Sci, Suzhou Inst Biomed Engn & Technol SIBET, Suzhou, Peoples R China

    1 shared publication

Latest Publications

  • Open Access

    A novel colorimetric immunosensor based on silk cocoon membrane-integrated ELISA for treponemal antibody detection

    by Hongmei Wang, Yizhi Huang, Qi Xiao, Yezhou Chen, Yujue Wang, Jingjing Tian, Yuqing Cai, Longhai Tang, Shaohua Ding, Shengbao Duan

    The global rise in syphilis incidence and the challenges of early diagnosis highlight the urgent need for convenient diagnostic tools. In this study, we present a colorimetric immunosensor for the detection of Treponema pallidum antibodies (TP-Ab) using a natural silk cocoon membrane (SCM) as the substrate, based on the principle of enzyme-linked immunosorbent assay (ELISA). The TP monoclonal antibody 3H12 and the chimera antigen TP99, comprising epitopes TP15, TP17, and TP47, were sequentially coupled to functionalized SCM to form the SCM-based TP-Ab immunosensor. The detection was quantified by color extraction, and the Corrected I red values were used as a judgment parameter. The TP-Ab immunosensor demonstrated a detection limit of 0.48 mIU/mL, lower than the 0.68 mIU/mL limit of commercial microplate ELISA kits. Furthermore, it exhibited no cross-reactivity with antibodies against other pathogens. Testing with a reference serum panel yielded 100% concordance with the reference results. Comprehensive statistical analysis of the Corrected I red values from the reference serum panel and banked samples indicated an optimal cutoff value of 0.0921, achieving 100% sensitivity, 97.96% specificity, and high overall accuracy, with an area under the curve of 0.9995 and a 95% confidence interval of 0.9979–1.00. Moreover, a statistically significant correlation with microplate ELISA was observed ( r = 0.9217, P < 0.0001). This reliable ELISA-integrated colorimetric immunosensor, featuring a three-dimensional porous structure and inherent bioactivity, contributes to improving the detection performance and provides a rapid and convenient diagnostic solution for syphilis. It is particularly well-suited for resource-limited settings where on-site testing is critical. IMPORTANCE: Syphilis remains a major global public health concern, particularly in resource-limited settings where early and accurate diagnosis is often hindered by technical and economic barriers. Here, we report a novel treponemal antibody (TP-Ab) immunosensor based on natural silk cocoon membrane (SCM), a biocompatible and porous material with intrinsic bioactivity. By integrating enzyme-linked immunosorbent assay principles and a recombinant TP15-17-47 chimera antigen, the SCM-based immunosensor enables colorimetric detection of TP-Ab with high specificity and visual readout. Unlike traditional methods that require complex instrumentation or expensive reagents, this platform offers a low-cost, portable, and easy-to-use alternative suitable for on-site or point-of-care testing. The findings highlight the potential of silk-derived biosensors in a promising direction for syphilis screening technologies.


  • Centrifugal microfluidic platform with digital image analysis for parallel red cell antigen typing

    by Shaohua Ding, Shengbao Duan, Yezhou Chen, Jinsong Xie, Jingjing Tian, Yong Li, Hongmei Wang


  • Convolutional neural network-based automatic classification for incomplete antibody reaction intensity in solid phase anti-human globulin test image

    by KeQing Wu, ShengBao Duan, YuJue Wang, HongMei Wang, Xin Gao

    The precise classification of incomplete antibody reaction intensity (IARI) in hydrogel chromatography medium high density medium solid-phase Coombs test is essential for haemolytic disease screening. However, an automatic and contactless method is required for accurate classification of IARI. Here, we present a deep ensemble learning model that integrates five different convolutional neural networks into a single model for IARI classification. A dataset, including 1628 IARI images and corresponding labels of IARI categories ((-), (1 +), (2 +), (3 +), and (4 +)), was used. We trained our model using 1302 IARIs and validated its performance using 326 IARIs. The proposed model achieved 100%, 99.4%, 99.4%, 100%, and 100% accuracies in the ( −), (1 +), (2 +), (3 +), and (4 +) categories, respectively. The results were compared with those of manual classification by immunologists (average accuracy: 99.8% vs. 88.3%, p < 0.01). Following model assistance, all three immunologists achieved increased accuracy (average accuracy: + 6.1%), with the average accuracy of junior immunologists maximum increasing by 11.3%. The time required for model classification was 0.094 s·image–1, whereas that required manually was 5.528 s·image–1. The proposed model can thus substantially improve the accuracy and efficiency of IARI classification and facilitate the automation of haemolytic disease screening equipment. Graphical abstract


  • Application of lyophilised human platelets for antibody detection in solid phase red cell adherence assay

    by Shengbao Duan, Mingyuan Wang, Shaohua Ding, Yezhou Chen, Shuangshi Wei, Wei Chen, Chun Zhang, Yong Li, Hongmei Wang


  • Open Access

    Extensive Expansion of the Speedy gene Family in Homininae and Functional Differentiation in Humans

    by Liang Wang, Hui Wang, Hongmei Wang, Yuhui Zhao, Xiaojun Liu, Gary Wong, Qinong Ye, Xiaoqin Xia, George F. Gao, Shan Gao

    Background: The cell cycle plays important roles in physiology and disease. The Speedy /RINGO family of atypical cyclins regulates the cell cycle. However, the origin, evolution and function of the Speedy family are not completely understood. Understanding the origins and evolution of Speedy family would shed lights on the evolution of complexity of cell cycles in eukaryotes. Results: Here, we performed a comprehensive identification of Speedy genes in 258 eukaryotic species and found that the Speedy subfamily E was extensively expanded in Homininae, characterized by emergence of a low-Spy1-identify domain. Furthermore, the Speedy gene family show functional differentiation in humans and have a distinct expression pattern, different regulation network and co-expressed gene networks associated with cell cycle and various signaling pathways. Expression levels of the Speedy gene family are prognostic biomarkers among different cancer types. Conclusions: Overall, we present a comprehensive view of the Speedy genes and highlight their potential function.