Hyung-Woo Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hyung-Woo Kim has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Sang-Yong Jung
Department of Electrical and Computer Engineering, Sungkyunkwan University, Seoul, Republic of Korea
4 shared publications - In-Seok Song
Department of Electrical and Computer Engineering, Sungkyunkwan University, Suwon, Republic of Korea
2 shared publications - Seok-Won Jung
Department of Electrical and Computer Engineering, Sungkyunkwan University, Suwon, Republic of Korea
2 shared publications - Seung-Gu Kang
Department of Electrical and Computer Engineering, Sungkyunkwan University, Suwon, South Korea
2 shared publications - Do Hyun Kang
Department of Electrical and Computer Engineering, Sungkyunkwan University, Suwon, Republic of Korea
1 shared publication - Han-Kyeol Yeo
Konkuk University
1 shared publication
Latest Publications
- 28 January 2026
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 21 (2) , 1837-1848
Design of Permanent Magnet Linear Motor to Prevent Irreversible Demagnetization and Reduce Detent Force
- 28 January 2026
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 21 (2) , 1837-1848
Design of Permanent Magnet Linear Motor to Prevent Irreversible Demagnetization and Reduce Detent Force
- 28 January 2026
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 21 (3) , 2561-2571
Improvement of Thrust Ripple in PMLSMs Considering Magnetic Saturation Using the Frozen Permeability Method
- 28 January 2026
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 21 (3) , 2561-2571
Improvement of Thrust Ripple in PMLSMs Considering Magnetic Saturation Using the Frozen Permeability Method
- 3 June 2024
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 19 (8) , 5135-5152
Coupled Problem Study with Structural Analysis Considering Barrier Filling of PMa-SynRM for Railway Vehicle
- 3 June 2024
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 19 (8) , 5135-5152
Coupled Problem Study with Structural Analysis Considering Barrier Filling of PMa-SynRM for Railway Vehicle
- Open Access
- 23 August 2022
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 18 (1) , 319-327
Design and Analysis of Permanent-Magnet Vernier Machine for Direct-Driven Wind Power Generator Considering Pole-Slot Combinations
Wind power turbines have increasingly attracted attention as a renewable energy source. Gearboxes in wind turbines reduce their efficiency, require periodic maintenance, and result in gearbox failure. Consequently, direct-driven generators with a high torque density have emerged as an alternative because they transmit the high torque of the wind turbine directly. Permanent-magnet vernier machines (PMVMs) possess a simple and robust structure and significantly high torque density at low speeds. Although various topologies and pole-slot combinations of PMVMs have been considered to enhance their performance, studies on fractional-slot distributed-winding PMVMs (FSDW PMVMs) remain limited compared with those on fractional-slot concentrated-winding PMVMs (FSCW PMVMs). In this study, we designed eight models, including permanent magnet synchronous machines (PMSMs), FSDW, and FSCW PMVMs for direct-driven wind power generators. Their performances in terms of torque density, torque ripple, losses, and power factor were compared and verified using finite element analysis. The FSDW PMVM was proposed as the best model for direct-driven wind power generators based on the torque density, torque ripple, and possibility of performance improvement.
- 23 August 2022
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 18 (1) , 319-327
Open AccessDesign and Analysis of Permanent-Magnet Vernier Machine for Direct-Driven Wind Power Generator Considering Pole-Slot Combinations
Wind power turbines have increasingly attracted attention as a renewable energy source. Gearboxes in wind turbines reduce their efficiency, require periodic maintenance, and result in gearbox failure. Consequently, direct-driven generators with a high torque density have emerged as an alternative because they transmit the high torque of the wind turbine directly. Permanent-magnet vernier machines (PMVMs) possess a simple and robust structure and significantly high torque density at low speeds. Although various topologies and pole-slot combinations of PMVMs have been considered to enhance their performance, studies on fractional-slot distributed-winding PMVMs (FSDW PMVMs) remain limited compared with those on fractional-slot concentrated-winding PMVMs (FSCW PMVMs). In this study, we designed eight models, including permanent magnet synchronous machines (PMSMs), FSDW, and FSCW PMVMs for direct-driven wind power generators. Their performances in terms of torque density, torque ripple, losses, and power factor were compared and verified using finite element analysis. The FSDW PMVM was proposed as the best model for direct-driven wind power generators based on the torque density, torque ripple, and possibility of performance improvement.