Ton Tran
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ton Tran has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Adrian Trivett
Monash Health, Melbourne, Victoria, Australia
1 shared publication - Ali Najafzadeh
Department of Mechanical and Aerospace Engineering, Monash University, Melbourne, VIC 3800, Australia
1 shared publication - Andrew Gordon
Department of Orthopaedic Surgery, Sheffield Teaching Hospitals NHS trust, Sheffield, UK
1 shared publication - Bernard K. Chen
Department of Mechanical and Aerospace Engineering, Monash University, 17 College Walk, Clayton, VIC 3800, Australia
1 shared publication - Dinusha Serandi Gunawardena
The Hong Kong Polytechnic University
1 shared publication - Ellie Bragan Turner
Dr Foster Ltd, London, UK
1 shared publication
Latest Publications
- Open Access
- 23 August 2022
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 3 (8) , 656-665
Kinematic alignment in total knee arthroplasty: a five-year prospective, multicentre, survivorship study
Aims: The mid-term results of kinematic alignment (KA) for total knee arthroplasty (TKA) using image derived instrumentation (IDI) have not been reported in detail, and questions remain regarding ligamentous stability and revisions. This paper aims to address the following: 1) what is the distribution of alignment of KA TKAs using IDI; 2) is a TKA alignment category associated with increased risk of failure or poor patient outcomes; 3) does extending limb alignment lead to changes in soft-tissue laxity; and 4) what is the five-year survivorship and outcomes of KA TKA using IDI? Methods: A prospective, multicentre, trial enrolled 100 patients undergoing KA TKA using IDI, with follow-up to five years. Alignment measures were conducted pre- and postoperatively to assess constitutional alignment and final implant position. Patient-reported outcome measures (PROMs) of pain and function were also included. The Australian Orthopaedic Association National Joint Arthroplasty Registry was used to assess survivorship. Results: The postoperative HKA distribution varied from 9° varus to 11° valgus. All PROMs showed statistical improvements at one year (p < 0.001), with further improvements at five years for Knee Osteoarthritis Outcome Score symptoms (p = 0.041) and Forgotten Joint Score (p = 0.011). Correlation analysis showed no difference (p = 0.610) between the hip-knee-ankle and joint line congruence angle at one and five years. Sub-group analysis showed no difference in PROMs for patients placed within 3° of neutral compared to those placed > 3°. There were no revisions for tibial loosening; however, there were reports of a higher incidence of poor patella tracking and patellofemoral stiffness. Conclusion: PROMs were not impacted by postoperative alignment category. Ligamentous stability was maintained at five years with joint line obliquity. There were no revisions for tibial loosening despite a significant portion of tibiae placed in varus; however, KA executed with IDI resulted in a higher than anticipated rate of patella complications. Cite this article: Bone Jt Open 2022;3(8):656–665.
- 23 August 2022
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 3 (8) , 656-665
Open AccessKinematic alignment in total knee arthroplasty: a five-year prospective, multicentre, survivorship study
Aims: The mid-term results of kinematic alignment (KA) for total knee arthroplasty (TKA) using image derived instrumentation (IDI) have not been reported in detail, and questions remain regarding ligamentous stability and revisions. This paper aims to address the following: 1) what is the distribution of alignment of KA TKAs using IDI; 2) is a TKA alignment category associated with increased risk of failure or poor patient outcomes; 3) does extending limb alignment lead to changes in soft-tissue laxity; and 4) what is the five-year survivorship and outcomes of KA TKA using IDI? Methods: A prospective, multicentre, trial enrolled 100 patients undergoing KA TKA using IDI, with follow-up to five years. Alignment measures were conducted pre- and postoperatively to assess constitutional alignment and final implant position. Patient-reported outcome measures (PROMs) of pain and function were also included. The Australian Orthopaedic Association National Joint Arthroplasty Registry was used to assess survivorship. Results: The postoperative HKA distribution varied from 9° varus to 11° valgus. All PROMs showed statistical improvements at one year (p < 0.001), with further improvements at five years for Knee Osteoarthritis Outcome Score symptoms (p = 0.041) and Forgotten Joint Score (p = 0.011). Correlation analysis showed no difference (p = 0.610) between the hip-knee-ankle and joint line congruence angle at one and five years. Sub-group analysis showed no difference in PROMs for patients placed within 3° of neutral compared to those placed > 3°. There were no revisions for tibial loosening; however, there were reports of a higher incidence of poor patella tracking and patellofemoral stiffness. Conclusion: PROMs were not impacted by postoperative alignment category. Ligamentous stability was maintained at five years with joint line obliquity. There were no revisions for tibial loosening despite a significant portion of tibiae placed in varus; however, KA executed with IDI resulted in a higher than anticipated rate of patella complications. Cite this article: Bone Jt Open 2022;3(8):656–665.
- Open Access
- 19 August 2020
- Published by MDPI AG in Bioengineering
- Vol. 7 (3) , 98
Application of Fibre Bragg Grating Sensors in Strain Monitoring and Fracture Recovery of Human Femur Bone
Fibre Bragg Grating (FBG) sensors are gaining popularity in biomedical engineering. However, specific standards for in vivo testing for their use are absolutely limited. In this study, in vitro experimental tests were performed to investigate the behaviors and applications of gratings attached to intact and fractured thighbone for a range of compression loading (<300 N) based around some usual daily activities. The wavelength shifts and the corresponding strain sensitivities of the FBG sensors were measured to determine their effectiveness in monitoring the femoral fracture healing process. Four different arrangements of FBG sensors were selected to measure strains at different critical locations on the femoral sawbones surface. Data obtained for intact and plated sawbones were compared using both embedded longitudinal and coiled FBG arrays. Strains were measured close to the fracture, posterior linea aspera and popliteal surface areas, as well as at the proximal and distal ends of the synthetic femur; their responses are discussed herein. The gratings on the longitudinally secured FBG arrays were found to provide high levels of sensitivity and precise measurements, even for relatively small loads (<100 N). Nevertheless, embedding angled FBG sensors is essential to measure the strain generated by applied torque on the femur bone. The maximum recorded strain of the plated femur was 503.97 µε for longitudinal and −274.97 µε for coiled FBG arrays, respectively. These project results are important to configure effective arrangements and orientations of FBG sensors with respect to fracture position and fixation implant for future in vivo experiments.
- 19 August 2020
- Published by MDPI AG in Bioengineering
- Vol. 7 (3) , 98
Open AccessApplication of Fibre Bragg Grating Sensors in Strain Monitoring and Fracture Recovery of Human Femur Bone
Fibre Bragg Grating (FBG) sensors are gaining popularity in biomedical engineering. However, specific standards for in vivo testing for their use are absolutely limited. In this study, in vitro experimental tests were performed to investigate the behaviors and applications of gratings attached to intact and fractured thighbone for a range of compression loading (<300 N) based around some usual daily activities. The wavelength shifts and the corresponding strain sensitivities of the FBG sensors were measured to determine their effectiveness in monitoring the femoral fracture healing process. Four different arrangements of FBG sensors were selected to measure strains at different critical locations on the femoral sawbones surface. Data obtained for intact and plated sawbones were compared using both embedded longitudinal and coiled FBG arrays. Strains were measured close to the fracture, posterior linea aspera and popliteal surface areas, as well as at the proximal and distal ends of the synthetic femur; their responses are discussed herein. The gratings on the longitudinally secured FBG arrays were found to provide high levels of sensitivity and precise measurements, even for relatively small loads (<100 N). Nevertheless, embedding angled FBG sensors is essential to measure the strain generated by applied torque on the femur bone. The maximum recorded strain of the plated femur was 503.97 µε for longitudinal and −274.97 µε for coiled FBG arrays, respectively. These project results are important to configure effective arrangements and orientations of FBG sensors with respect to fracture position and fixation implant for future in vivo experiments.
- Open Access
- 22 May 2017
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 18 (1) , 1-8
Variation in Prosthetic Joint Infection and treatment strategies during 4.5 years of follow-up after primary joint arthroplasty using administrative data of 41397 patients across Australian, European and United States hospitals
To identify best practices and quality improvement initiatives, we aimed to assess whether the incidence of Periprosthetic Joint Infection (PJI) and treatment strategies differed across patients treated in Australian, European and United States (US) hospitals. Routinely collected administrative data for 41397 patients undergoing a primary total hip or knee arthroplasty between July 2007-December 2010 across 22 hospitals were included. Patients were followed for 2 years looking for PJI occurrence, defined as early (within 4 weeks) and late PJI, and surgical treatment during 2.5 years after PJI diagnosis. Logistic and Poisson regression models were used to test for differences in PJI occurrence and treatment strategies across the three geographical regions, adjusted for age, sex, joint and Elixhauser comorbidity groups. PJI occurrence varied from 1.4% in European to 1.7% in Australian patients, which were significantly higher than US patients after adjustment for patient characteristics (OR 1.24 [1.01–1.52] and 1.40 [1.03–1.91] respectively). Early PJIs varied between 0.3% in European to 0.6% in Australian patients, but adjusted rates were similar. Revision following PJI was significantly lower in Australian than in US patients (OR 0.46 [0.25–0.86]) as were the total number of revisions (RR 0.51 [0.36–0.71]) and number of surgical procedures (RR 0.60 [0.44–0.81]) used to treat PJI. The overall PJI rate was significantly higher in Australian patients, but fewer procedures were needed to treat these PJIs. Future research should reveal whether this reflects PJIs caught earlier or less severe when diagnosed, and whether this is associated with the longer length of stay after primary arthroplasty in Australian hospitals.
- 22 May 2017
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 18 (1) , 1-8
Open AccessVariation in Prosthetic Joint Infection and treatment strategies during 4.5 years of follow-up after primary joint arthroplasty using administrative data of 41397 patients across Australian, European and United States hospitals
To identify best practices and quality improvement initiatives, we aimed to assess whether the incidence of Periprosthetic Joint Infection (PJI) and treatment strategies differed across patients treated in Australian, European and United States (US) hospitals. Routinely collected administrative data for 41397 patients undergoing a primary total hip or knee arthroplasty between July 2007-December 2010 across 22 hospitals were included. Patients were followed for 2 years looking for PJI occurrence, defined as early (within 4 weeks) and late PJI, and surgical treatment during 2.5 years after PJI diagnosis. Logistic and Poisson regression models were used to test for differences in PJI occurrence and treatment strategies across the three geographical regions, adjusted for age, sex, joint and Elixhauser comorbidity groups. PJI occurrence varied from 1.4% in European to 1.7% in Australian patients, which were significantly higher than US patients after adjustment for patient characteristics (OR 1.24 [1.01–1.52] and 1.40 [1.03–1.91] respectively). Early PJIs varied between 0.3% in European to 0.6% in Australian patients, but adjusted rates were similar. Revision following PJI was significantly lower in Australian than in US patients (OR 0.46 [0.25–0.86]) as were the total number of revisions (RR 0.51 [0.36–0.71]) and number of surgical procedures (RR 0.60 [0.44–0.81]) used to treat PJI. The overall PJI rate was significantly higher in Australian patients, but fewer procedures were needed to treat these PJIs. Future research should reveal whether this reflects PJIs caught earlier or less severe when diagnosed, and whether this is associated with the longer length of stay after primary arthroplasty in Australian hospitals.