PWPeder Wiklund

Peder Wiklund

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Peder Wiklund has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Correction: Tumor deposits on MRI in rectal cancer—detection and differentiation from lymph nodes with histopathological correlation

    by Simon Lundström, Staffan Täckström, Peder Wiklund, Maja Haskå, Erik Agger, Lennart Nedar, Pamela Buchwald

  • Open Access

    Tumor deposits on MRI in rectal cancer—detection and differentiation from lymph nodes with histopathological correlation

    by Simon Lundström, Staffan Täckström, Peder Wiklund, Maja Haskå, Erik Agger, Lennart Nedar, Pamela Buchwald

    Objective: Tumor deposits (TDs) are a negative prognostic factor in colorectal cancer, independent of lymph node metastasis (LNM). This study aimed to investigate the ability of pre-operative MRI to identify TDs and differentiate them from LNM in rectal cancer. Materials and methods: Patients with histopathological N1-N2 rectal cancer with and without TDs who underwent curative-intent primary surgery between 2013 and 2023 were retrospectively included. Three radiologists independently reviewed pre-operative MR images for the presence of TDs and LNM. Histopathology served as the reference standard from which interobserver agreement by Cohen’s kappa (κ) was calculated. Unblinded node-to-node comparison of MRI and histopathological images was used to identify sources of discrepancies between the modalities. Post hoc analysis stratified on nodal size (> or ≤ 5 mm) was performed. Results: Eighty-eight patients (50% with TDs on histopathology, 74% male, median age 70 [20–89] years) were included, of whom 27 were excluded due to poor image quality. Agreement between MRI and histopathology (p), both for TD-presence (κ = −0.04) and LNM-presence (κ = 0.16), was low. In the node-by-node comparison, 43 out of 50 pTDs (86%) measured ≤ 5 mm, and 131 of 167 pLNM (78%) measured ≤ 5 mm. In post hoc analysis of smaller (≤ 5 mm) nodules, no pTDs and 3% of pLNM were diagnosed using MRI. Conclusion: MRI demonstrated limited ability in detecting and differentiating TDs and LNM in pre-operative low-risk patients. Diagnostic performance was particularly poor for nodules ≤ 5 mm, which constituted 174 out of 217 (80%) pathological nodular structures. Key Points: Questions Tumor deposits and lymph node metastasis are important factors for staging rectal cancer, but the ability of pre-operative MRI to detect and differentiate them remains unclear . Findings In low-risk rectal cancer patients treated with primary surgery, tumor deposits and lymph node metastasis are often small (≤ 5 mm) and not detected by MRI . Clinical relevance MRI has a limited ability to identify and differentiate small (≤ 5 mm) tumor deposits and lymph node metastasis in rectal cancer, which must be considered during pre-operative staging and neoadjuvant treatment planning .


  • Vertebral compression fractures at abdominal CT: underdiagnosis, undertreatment, and evaluation of an AI algorithm

    by Peder Wiklund, David Buchebner, Mats Geijer

    Vertebral compression fractures (VCFs) are common and indicate a high future risk of additional osteoporotic fractures. However, many VCFs are unreported by radiologists, and even if reported, many patients do not receive treatment. The purpose of the study was to evaluate a new artificial intelligence (AI) algorithm for the detection of VCFs and to assess the prevalence of reported and unreported VCFs. This retrospective cohort study included patients over age 60 yr with an abdominal CT between January 18, 2019 and January 18, 2020. Images and radiology reports were reviewed to identify reported and unreported VCFs, and the images were processed by an AI algorithm. For reported VCFs, the electronic health records were reviewed regarding subsequent osteoporosis screening and treatment. Totally, 1112 patients were included. Of these, 187 patients (16.8%) had a VCF, of which 62 had an incident VCF and 49 had a previously unknown prevalent VCF. The radiologist reporting rate of these VCFs was 30% (33/111). For moderate and severe (grade 2–3) VCF, the AI algorithm had 85.2% sensitivity, 92.3% specificity, 57.8% positive predictive value, and 98.1% negative predictive value. Three of 30 patients with reported VCFs started osteoporosis treatment within a year. The AI algorithm had high accuracy for the detection of VCFs and could be very useful in increasing the detection rate of VCFs, as there was a substantial underdiagnosis of VCFs. However, as undertreatment in reported cases was substantial, to fully realize the potential of AI, changes to the management pathway outside of the radiology department are imperative.


  • Open Access

    Incidental pulmonary embolism in abdominal CT: detection rate and characteristics with artificial intelligence

    by Peder Wiklund, Koshiar Medson

    Abdominal CT is a mainstay in the evaluation of abdominal infections, trauma, oncology, and postoperative complications. Pulmonary embolism is a common complication, but there is a risk that these ancillary findings are overlooked. In addition, data on detection rate and characteristics of incidental pulmonary embolism (iPE) on abdominal CT are lacking. The current study compared the period before and after implementing an artificial intelligence (AI) algorithm for iPE detection regarding detection rate and characteristics. A retrospective cross-sectional study was performed on abdominal CTs between August 1, 2019, and January 31, 2021 (before AI implementation, 8026 studies) and August 1, 2021, and January 31, 2023 (after AI implementation, 8765 studies). iPE cases were identified through text search and manually confirmed. Study indication and urgency were recorded for iPE patients, and the most proximal iPE level was assessed. A total of 1000 cases after AI implementation were randomly selected and manually reviewed for AI accuracy analysis. A total of 5876 patients with a mean age of 63.6 ± 17.7 years were included before AI implementation, and 6310 patients with a mean age of 63.2 ± 18.3 years after AI implementation. The iPE detection rate was higher after AI implementation, 0.57% (50/8765 studies) vs 0.12% (10/8026), P < .001. The most common study indications were abdominal pain (25%, 15/60 cases) and infection (30%, 18/60 cases). There were no differences in CT pulmonary angiography usage or the most proximal extent of the iPE between the periods before or after AI implementation, P > .05. AI identified 46/50 of the reported iPE with 7 AI false-positive cases for a positive predictive value of 87% (95% confidence interval: 75-93%). In the manually reviewed randomly selected subset, iPE prevalence was 1.7% (15/874, 95% confidence interval: 1.0-2.8%) with AI having 40% sensitivity (95% CI, 16-68) and 100% specificity (95% CI, 99.5-100). Implementing AI for iPE detection and triage increased the iPE detection rate in abdominal CT. The AI sensitivity was moderate, with very few AI false positives.


  • Use of a Deep Learning Algorithm for Detection and Triage of Cancer-associated Incidental Pulmonary Embolism

    by Peder Wiklund, Koshiar Medson

    Incidental pulmonary embolism (iPE) is a common complication in patients with cancer, and there is often a delay in reporting these studies and a delay between the finalized report and time to treatment. In addition, unreported iPE is common. This retrospective single-center cross-sectional study evaluated the effect of an artificial intelligence (AI) algorithm on the report turnaround time, time to treatment, and detection rate in patients with cancer-associated iPE. Adult patients with cancer were included either before (July 1, 2018, to June 30, 2019) or after (November 1, 2020, to April 30, 2021) implementation of an AI algorithm for iPE detection and triage. The results demonstrated that reported iPE prevalence was significantly higher in the period after AI implementation (2.5% [26 of 1036 studies] vs 0.8% [16 of 1892 studies], P < .001). Both report that the turnaround time (median, 0.66 hour vs 24.68 hours, P < .001) and time to treatment (median, 0.98 hour vs 28.05 hours, P < .001) were significantly shorter after AI implementation. In conclusion, the use of AI for detection and triage of iPE in clinical practice resulted in an increased detection rate of iPE and significantly shorter report turnaround time and time to treatment for patients with cancer-associated iPE.


  • Open Access

    Incidental pulmonary embolism in patients with cancer: prevalence, underdiagnosis and evaluation of an AI algorithm for automatic detection of pulmonary embolism

    by Peder Wiklund, Koshiar Medson, Johan Elf

    Objectives: To assess the prevalence of reported and unreported incidental pulmonary embolism (iPE) in patients with cancer, and to evaluate an artificial intelligence (AI) algorithm for automatic detection of iPE. Methods: Retrospective cohort study on patients with cancer with an elective CT study including the chest between 2018-07-01 and 2019-06-30. All study reports and images were reviewed to identify reported and unreported iPE and were processed by the AI algorithm. Results: One thousand sixty-nine patients (1892 studies) were included. Per study, iPE was present in 75 studies (4.0%), of which 16 (21.3%) were reported. Unreported iPE had a significantly lower number of involved vessels compared to reported iPE, with a median of 2 (interquartile range, IQR, 1–4) versus 5 (IQR 3–9.75), p < 0.001. There were no significant differences in age, cancer type, or attenuation of the main pulmonary artery. The AI algorithm correctly identified 68 of 75 iPE, with 3 false positives (sensitivity 90.7%, specificity 99.8%, PPV 95.6%, NPV 99.6%). False negatives occurred in cases with 1–3 involved vessels. Of the unreported iPE, 32/59 (54.2%) were proximal to the subsegmental arteries. Conclusion: In patients with cancer, the prevalence of iPE was 4.0%, of which only 21% were reported. Greater than 50% of unreported iPE were proximal to the subsegmental arteries. The AI algorithm had a very high sensitivity and specificity with only three false positives, with the potential to increase the detection rate of iPE. Key Points: • In a retrospective single-center study on patients with cancer, unreported iPE were common, with the majority lying proximal to the subsegmental arteries. • The evaluated AI algorithm had a very high sensitivity and specificity, so has the potential to increase the detection rate of iPE.