Solomon Feleke
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Solomon Feleke has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Raavi Satish
Department of Electrical & Electronics Engineering, Anil Neerukonda Institute of Technology and Science (A), Visakhapatnam 531162, AP, India
7 shared publications - Almoataz Youssef Abdelaziz
Electrical Power and Machines Engineering Department, Faculty of Engineering, Ain Shams University, Cairo, Egypt
4 shared publications - Balamurali Pydi
Aditya Institute of Technology and Management
4 shared publications - Degarege Anteneh
Department of Electrical and Computer Engineering, Debre Berhan University, Debre Berhan 445, Ethiopia
4 shared publications - Adel El-Shahat
Purdue University
3 shared publications - Hossam Kotb
Department of Electrical Power and Machines, Faculty of Engineering, Alexandria University, Alexandria, Egypt
2 shared publications
Latest Publications
- Open Access
Assessment of Potential Wind Sites for Power Integration in Ethiopia: A Case Study of Arerti, Sela Dingay, Debre Berhan, Mega, and Gode
With hydropower supplying nearly 94% of Ethiopia’s electricity, the national power grid is extremely vulnerable to recurrent droughts and erratic rainfall. To mitigate this risk, this study examines the wind power potential across five specific locations: Arerti, Sela Dingay, Debre Berhan, Mega, and Gode. By combining on-site mast measurements with datasets from NASA and the Global Wind Atlas, we evaluated wind characteristics at industry-standard hub heights of 80 m and 100 m. The analysis focused on wind power density (WPD), Weibull stability parameters (k and c), and directional consistency. The results indicate that Gode and Mega are the premier choices for commercial development, showing average speeds above 8.5 m/s and power densities exceeding 500 W/m2 at the 100 m level. Gode stands out as the most reliable site, with a Weibull shape factor (k) of 2.8 and a scale factor (c) of 9.1 m/s. We modeled a standard 3 MW turbine while factoring in a 20% loss for real-world conditions; this yielded net annual energy productions of 9461 MWh (36% CF) for Gode, 9040 MWh (34.4% CF) for Mega, and 8619 MWh (32.8% CF) for Arerti. While Sela Dingay and Debre Berhan have lower initial yields, their feasibility improves significantly when using towers taller than 80 m. Wind rose data reveals that Gode and Arerti have highly unidirectional flows, which simplifies turbine micro-siting. Notably, Arerti provides a unique economic advantage due to its location right next to existing 132/230 kV transmission infrastructure and industrial load centers. Overall, these findings provide a definitive technical roadmap for Ethiopia to diversify its energy portfolio and meet its Climate-Resilient Green Economy (CRGE) objectives.
Open AccessAssessment of Potential Wind Sites for Power Integration in Ethiopia: A Case Study of Arerti, Sela Dingay, Debre Berhan, Mega, and Gode
With hydropower supplying nearly 94% of Ethiopia’s electricity, the national power grid is extremely vulnerable to recurrent droughts and erratic rainfall. To mitigate this risk, this study examines the wind power potential across five specific locations: Arerti, Sela Dingay, Debre Berhan, Mega, and Gode. By combining on-site mast measurements with datasets from NASA and the Global Wind Atlas, we evaluated wind characteristics at industry-standard hub heights of 80 m and 100 m. The analysis focused on wind power density (WPD), Weibull stability parameters (k and c), and directional consistency. The results indicate that Gode and Mega are the premier choices for commercial development, showing average speeds above 8.5 m/s and power densities exceeding 500 W/m2 at the 100 m level. Gode stands out as the most reliable site, with a Weibull shape factor (k) of 2.8 and a scale factor (c) of 9.1 m/s. We modeled a standard 3 MW turbine while factoring in a 20% loss for real-world conditions; this yielded net annual energy productions of 9461 MWh (36% CF) for Gode, 9040 MWh (34.4% CF) for Mega, and 8619 MWh (32.8% CF) for Arerti. While Sela Dingay and Debre Berhan have lower initial yields, their feasibility improves significantly when using towers taller than 80 m. Wind rose data reveals that Gode and Arerti have highly unidirectional flows, which simplifies turbine micro-siting. Notably, Arerti provides a unique economic advantage due to its location right next to existing 132/230 kV transmission infrastructure and industrial load centers. Overall, these findings provide a definitive technical roadmap for Ethiopia to diversify its energy portfolio and meet its Climate-Resilient Green Economy (CRGE) objectives.
- Open Access
- 13 May 2024
- Published by MDPI AG in Preprints.org
Feasibility Assessment of Wind Energy Study in Selected Districts of North Shewa Zone, Amhara, Ethiopia
In this paper, the feasibility and potential assessment (PA) of wind power in six different areas MehalMeda, Eneware, DebreBerhan, AlemKetema, GundoMekel, and Majet are investigated. The data is collected from the National Metrological Agency (NMA) in Addis Ababa and from the districts of the case study areas and analyzed using MATLAB and HOMER software. Using the data collected at 10 meter height, wind direction using a wind rose, the wind frequency distribution, and wind turbine characteristics have been analyzed. Moreover, to obtain a more realistic wind potential study, the wind speed at a 10 meter height is extrapolated to a height of 50 meter in order to determine wind speed, wind power density, and wind energy density. The average wind speed of the zone at 10m and 50m heights are 1.58 m/s and 1.99 m/s, 3.06 m/s and 3.85 m/s, 4.75 m/s and 5.98 m/s, 2.29 m/s and 2.88 m/s, 1.01 m/s and 1.27 m/s and 4.07 and 5.12m/s at Alemketema, Debreberhan, Eneware, Gundemeskel, Majete and Mehalmeda respectively. The extrapolated result shows that the maximum wind speed and power densities at a height of 50 meter for Eneware, MehalMeda and Debre Berhan are 10.4 m/s, 689 W/m2, 8.9m/s, 429 W/m2 and 6.3m/s, 152.2 W/m2 respectively. The energy densities at a height of 50 meter for AlemKetema, DebreBerhan, Eneware, GundoMekel, Majete, and MehalMeda are 181.06 kWh/m2*yr , 1332.83 kWh/ m2*yr, 6078.91 kWh/ m2*yr, 857.76 kWh/ m2*yr, 58.78 kWh/ m2*yr, and 3939.42 kWh/ m2*yr respectively. As per the international standard for wind power and wind speed classification, considering the extrapolated height, Eneware, MehalMeda, and DebreBerhan have feasible wind potential for both small-scale and large-scale wind farm implementation, whereas Majete, AlemKetema, and GundoMeskel of the North Shewa Zone in the Amhara region have poor wind potential.
- 13 May 2024
- Published by MDPI AG in Preprints.org
Open AccessFeasibility Assessment of Wind Energy Study in Selected Districts of North Shewa Zone, Amhara, Ethiopia
In this paper, the feasibility and potential assessment (PA) of wind power in six different areas MehalMeda, Eneware, DebreBerhan, AlemKetema, GundoMekel, and Majet are investigated. The data is collected from the National Metrological Agency (NMA) in Addis Ababa and from the districts of the case study areas and analyzed using MATLAB and HOMER software. Using the data collected at 10 meter height, wind direction using a wind rose, the wind frequency distribution, and wind turbine characteristics have been analyzed. Moreover, to obtain a more realistic wind potential study, the wind speed at a 10 meter height is extrapolated to a height of 50 meter in order to determine wind speed, wind power density, and wind energy density. The average wind speed of the zone at 10m and 50m heights are 1.58 m/s and 1.99 m/s, 3.06 m/s and 3.85 m/s, 4.75 m/s and 5.98 m/s, 2.29 m/s and 2.88 m/s, 1.01 m/s and 1.27 m/s and 4.07 and 5.12m/s at Alemketema, Debreberhan, Eneware, Gundemeskel, Majete and Mehalmeda respectively. The extrapolated result shows that the maximum wind speed and power densities at a height of 50 meter for Eneware, MehalMeda and Debre Berhan are 10.4 m/s, 689 W/m2, 8.9m/s, 429 W/m2 and 6.3m/s, 152.2 W/m2 respectively. The energy densities at a height of 50 meter for AlemKetema, DebreBerhan, Eneware, GundoMekel, Majete, and MehalMeda are 181.06 kWh/m2*yr , 1332.83 kWh/ m2*yr, 6078.91 kWh/ m2*yr, 857.76 kWh/ m2*yr, 58.78 kWh/ m2*yr, and 3939.42 kWh/ m2*yr respectively. As per the international standard for wind power and wind speed classification, considering the extrapolated height, Eneware, MehalMeda, and DebreBerhan have feasible wind potential for both small-scale and large-scale wind farm implementation, whereas Majete, AlemKetema, and GundoMeskel of the North Shewa Zone in the Amhara region have poor wind potential.
- Open Access
- 19 September 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (18) , 13892
Frequency Stability Enhancement Using Differential-Evolution- and Genetic-Algorithm-Optimized Intelligent Controllers in Multiple Virtual Synchronous Machine Systems
In this paper, multiple virtual synchronous machines (VISMAs) with fuzzy proportional integral derivative (FPID) controllers optimized by differential evolution (DE) are proposed to maintain frequency stability in the grid in the presence of renewable penetration, such as wind and solar photovoltaic (PV) systems, residential loads, and industrial loads, by reducing the area control error in the objective function. Simulations are conducted using MATLAB/Simulink, and in the optimization process, the integral of the time-weighted absolute error (ITAE) is used as the objective function. In the work to obtain optimized values of renewable energy sources (RESs), fuzzy membership functions, controller gain parameters, and loads for system modeling, differential evolution and genetic algorithm (GA) methods are applied and the results were compared. It was shown that better results were achieved while FPID controllers were optimized by DE in the presence of multiple VISMAs than DE in the presence of single VISMAs and GA in multiple VISMAs. Moreover, the study is compared to integral control methods in which, compared to all controllers, the proposed controller reduces undershoot by 0.0674 Hz more than a single VISMAs, in which it is improved approximately by 97.82%. Similarly, the proposed controller improves the system settling time, rise time, and overshoot by more than 99.5% compared to the classical integral controller. To examine the robust operation of the system under the proposed controller, the system was run under a wide range of disturbances and uncertainties using random load perturbation of ± 20%, in which the proposed controller retains the system frequency by reducing or damping the system oscillation.
- 19 September 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (18) , 13892
Open AccessFrequency Stability Enhancement Using Differential-Evolution- and Genetic-Algorithm-Optimized Intelligent Controllers in Multiple Virtual Synchronous Machine Systems
In this paper, multiple virtual synchronous machines (VISMAs) with fuzzy proportional integral derivative (FPID) controllers optimized by differential evolution (DE) are proposed to maintain frequency stability in the grid in the presence of renewable penetration, such as wind and solar photovoltaic (PV) systems, residential loads, and industrial loads, by reducing the area control error in the objective function. Simulations are conducted using MATLAB/Simulink, and in the optimization process, the integral of the time-weighted absolute error (ITAE) is used as the objective function. In the work to obtain optimized values of renewable energy sources (RESs), fuzzy membership functions, controller gain parameters, and loads for system modeling, differential evolution and genetic algorithm (GA) methods are applied and the results were compared. It was shown that better results were achieved while FPID controllers were optimized by DE in the presence of multiple VISMAs than DE in the presence of single VISMAs and GA in multiple VISMAs. Moreover, the study is compared to integral control methods in which, compared to all controllers, the proposed controller reduces undershoot by 0.0674 Hz more than a single VISMAs, in which it is improved approximately by 97.82%. Similarly, the proposed controller improves the system settling time, rise time, and overshoot by more than 99.5% compared to the classical integral controller. To examine the robust operation of the system under the proposed controller, the system was run under a wide range of disturbances and uncertainties using random load perturbation of ± 20%, in which the proposed controller retains the system frequency by reducing or damping the system oscillation.
- 14 June 2023
- Published by Springer Nature
- p. 391-407
Load Frequency Control in Two-Area Interconnected Systems Using DE-PID and PSO-PID
- 14 June 2023
- Published by Springer Nature
- p. 391-407
Load Frequency Control in Two-Area Interconnected Systems Using DE-PID and PSO-PID
- Open Access
- 23 March 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (7) , 5625
DE-Based Design of an Intelligent and Conventional Hybrid Control System with IPFC for AGC of Interconnected Power System
In this study, a fuzzy proportional integral derivative controller (FPID) was adjusted using the differential evolution (DE) method to enhance the automated generation control (AGC) of a three-zone reheat-type power system. The objective function used in this study was an integral of the time-weighted absolute error (ITAE). In the optimization, the gain control parameters of the proportional integral (PI), the integral (I), and FPID were optimized and compared to improve the limitations drawn by the controller over a few parameters. To demonstrate that FPID controllers with IPFC produce better and more accurate optimization results than integral and PI controllers optimized by DE, the interline power flow control (IPFC) of a flexible AC transmission system (FACTS) device with suitable connections and control parameter optimization was used. Also, the particle swarm optimization (PSO) PID with IPFC was compared with the proposed DEFPID + IPFC, and better results were achieved by using the DE technique. Similarly, to demonstrate the suggested technology’s strong control capacity, random load changes were applied to the system in various conditions, and it was demonstrated that the suggested control unit easily tolerated random load perturbations and returned the system to a stable functioning state.
- 23 March 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (7) , 5625
Open AccessDE-Based Design of an Intelligent and Conventional Hybrid Control System with IPFC for AGC of Interconnected Power System
In this study, a fuzzy proportional integral derivative controller (FPID) was adjusted using the differential evolution (DE) method to enhance the automated generation control (AGC) of a three-zone reheat-type power system. The objective function used in this study was an integral of the time-weighted absolute error (ITAE). In the optimization, the gain control parameters of the proportional integral (PI), the integral (I), and FPID were optimized and compared to improve the limitations drawn by the controller over a few parameters. To demonstrate that FPID controllers with IPFC produce better and more accurate optimization results than integral and PI controllers optimized by DE, the interline power flow control (IPFC) of a flexible AC transmission system (FACTS) device with suitable connections and control parameter optimization was used. Also, the particle swarm optimization (PSO) PID with IPFC was compared with the proposed DEFPID + IPFC, and better results were achieved by using the DE technique. Similarly, to demonstrate the suggested technology’s strong control capacity, random load changes were applied to the system in various conditions, and it was demonstrated that the suggested control unit easily tolerated random load perturbations and returned the system to a stable functioning state.
- Open Access
Feasibility and Potential Assessment of Solar Resources: A Case Study in North Shewa Zone, Amhara, Ethiopia
The feasibility and potential assessment (PA) of solar PV energy is one of the key factors in identifying the most promising areas for the installation of solar PV stations. It determines the useful energy generated in the given area. This paper assesses the solar energy distribution and PA in the North Shewa administration zone. Based on the data collected and analysis made, it is found that more than 80% of the North Shewa areas are suitable for the solar energy generation for off-grid and on-grid systems. Hence, the solar potential of the North Shewa zone completely fulfills the standards of sunshine, solar radiation, and temperature. That is, most of the areas have solar radiation of 5.2 kWh/m2, and daily sunshine is greater than 7 h. The maximum energy production is found in December in Shewa Robit, Mehal Meda, Eneware, Debre Berhan, Alem Ketema, and Sela Dengay with 175.35 kWh, 188.18 kWh, 180.78 kWh, 189.54 kWh, 175.78 kWh, and 189.63 kWh, respectively. This is a good opportunity for investors to invest in solar PV electricity generation. It will solve the issue of electricity supply to the community, which currently relies on wood and fossil fuels. It also highlights the positive opportunities for the future implementation of solar energy.
Open AccessFeasibility and Potential Assessment of Solar Resources: A Case Study in North Shewa Zone, Amhara, Ethiopia
The feasibility and potential assessment (PA) of solar PV energy is one of the key factors in identifying the most promising areas for the installation of solar PV stations. It determines the useful energy generated in the given area. This paper assesses the solar energy distribution and PA in the North Shewa administration zone. Based on the data collected and analysis made, it is found that more than 80% of the North Shewa areas are suitable for the solar energy generation for off-grid and on-grid systems. Hence, the solar potential of the North Shewa zone completely fulfills the standards of sunshine, solar radiation, and temperature. That is, most of the areas have solar radiation of 5.2 kWh/m2, and daily sunshine is greater than 7 h. The maximum energy production is found in December in Shewa Robit, Mehal Meda, Eneware, Debre Berhan, Alem Ketema, and Sela Dengay with 175.35 kWh, 188.18 kWh, 180.78 kWh, 189.54 kWh, 175.78 kWh, and 189.63 kWh, respectively. This is a good opportunity for investors to invest in solar PV electricity generation. It will solve the issue of electricity supply to the community, which currently relies on wood and fossil fuels. It also highlights the positive opportunities for the future implementation of solar energy.
- Open Access
- 7 March 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (6) , 4751
Damping of Frequency and Power System Oscillations with DFIG Wind Turbine and DE Optimization
Wind power is one of the most promising renewable energy resources and could become a solution to contribute to the present energy and global warming crisis of the world. The commonly used doubly fed induction generator (DFIG) wind turbines have a general trend of increasing oscillation damping. Unless properly controlled, the high penetration of wind energy will increase the oscillation and affect the control and dynamic interaction of the interconnected generators. This paper discusses power oscillation damping control in the automatic generation control (AGC) of two-area power systems with DFIG wind turbines and Matlab code/Simulink interfacing optimization methods. The differential evolution (DE) optimization technique is used to obtain the controller gain parameters. In the optimization process, a step load perturbation (SLP) of 1% has been considered in Area 1 only, and the integral of time weighted absolute error (ITAE) cost function is used. Three different test studies have been examined on the same power system model with non-reheat turbine thermal power plants. In the first case, the power system model is simulated without a controller. In Case Study 2, the system is simulated with the presence of DFIG and without a controller. In Case Study 3, the system is simulated with a PID controller and DFIG. Most of the studies available in the literature do not optimize the appropriate wind penetrating speed gain parameters for the system and do not consider the ITAE as an objective function to reduce area control error. In this regard, the main contribution and result of this paper is—with the proposed PID+DFIG optimized DE—the ITAE objective function error value in the case study without a controller being 6.7865, which is reduced to 1.6008 in the case study with PID+DFIG-optimized DE. In addition, with the proposed controller methods, the dynamic system time responses such as rise time, settling time, overshoot, and undershoot are improved for system tie-line power, change in frequency, and system area controller error. Similarly, with the proposed controller, fast system convergence and fast system oscillation damping are achieved. Generally, it is inferred that the incorporation of DFIG wind turbines in both areas has appreciably improved the dynamic performance and system stability under consideration.
- 7 March 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (6) , 4751
Open AccessDamping of Frequency and Power System Oscillations with DFIG Wind Turbine and DE Optimization
Wind power is one of the most promising renewable energy resources and could become a solution to contribute to the present energy and global warming crisis of the world. The commonly used doubly fed induction generator (DFIG) wind turbines have a general trend of increasing oscillation damping. Unless properly controlled, the high penetration of wind energy will increase the oscillation and affect the control and dynamic interaction of the interconnected generators. This paper discusses power oscillation damping control in the automatic generation control (AGC) of two-area power systems with DFIG wind turbines and Matlab code/Simulink interfacing optimization methods. The differential evolution (DE) optimization technique is used to obtain the controller gain parameters. In the optimization process, a step load perturbation (SLP) of 1% has been considered in Area 1 only, and the integral of time weighted absolute error (ITAE) cost function is used. Three different test studies have been examined on the same power system model with non-reheat turbine thermal power plants. In the first case, the power system model is simulated without a controller. In Case Study 2, the system is simulated with the presence of DFIG and without a controller. In Case Study 3, the system is simulated with a PID controller and DFIG. Most of the studies available in the literature do not optimize the appropriate wind penetrating speed gain parameters for the system and do not consider the ITAE as an objective function to reduce area control error. In this regard, the main contribution and result of this paper is—with the proposed PID+DFIG optimized DE—the ITAE objective function error value in the case study without a controller being 6.7865, which is reduced to 1.6008 in the case study with PID+DFIG-optimized DE. In addition, with the proposed controller methods, the dynamic system time responses such as rise time, settling time, overshoot, and undershoot are improved for system tie-line power, change in frequency, and system area controller error. Similarly, with the proposed controller, fast system convergence and fast system oscillation damping are achieved. Generally, it is inferred that the incorporation of DFIG wind turbines in both areas has appreciably improved the dynamic performance and system stability under consideration.
- Open Access
DE-Algorithm-Optimized Fuzzy-PID Controller for AGC of Integrated Multi Area Power System with HVDC Link
A power system’s nonlinearity and complexity increase from time to time due to increases of power demand. Therefore, properly designed power system controlsare required. Without these, system instability will cause equipment failures, and possibly even cascading events and blackouts. To cope with this, intelligent controllers using soft computing are necessary for real time operation. In this paper, the reheat type three-area thermal power system is considered, and the output scaling factors, gain parameters of fuzzy membership functions, and parameters of fuzzy-proportional integral derivative (FPID) controllers are optimized using a differential evolution (DE) optimization techniqueand integral time multiplied absolute error (ITAE) as objective functions. To improve the limitations of the controller and to enhance stability of the system, high voltage direct current (HVDC) technology is advantageous due to its quickresponse capabilities. In this paper, a HVDC is connected in parallel to the system, revealing that a FPID controller with a HVDC provides better and more accurate resultscompared to a system without a controller. The test results presented in this paper show the proposed controller’s suitability for managing random load changes.
Open AccessDE-Algorithm-Optimized Fuzzy-PID Controller for AGC of Integrated Multi Area Power System with HVDC Link
A power system’s nonlinearity and complexity increase from time to time due to increases of power demand. Therefore, properly designed power system controlsare required. Without these, system instability will cause equipment failures, and possibly even cascading events and blackouts. To cope with this, intelligent controllers using soft computing are necessary for real time operation. In this paper, the reheat type three-area thermal power system is considered, and the output scaling factors, gain parameters of fuzzy membership functions, and parameters of fuzzy-proportional integral derivative (FPID) controllers are optimized using a differential evolution (DE) optimization techniqueand integral time multiplied absolute error (ITAE) as objective functions. To improve the limitations of the controller and to enhance stability of the system, high voltage direct current (HVDC) technology is advantageous due to its quickresponse capabilities. In this paper, a HVDC is connected in parallel to the system, revealing that a FPID controller with a HVDC provides better and more accurate resultscompared to a system without a controller. The test results presented in this paper show the proposed controller’s suitability for managing random load changes.