Ekaterina A. Chizhonkova
Research Subjects
Ekaterina A. Chizhonkova has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Konstantin S. Avetisov
Krasnov Research Institute of Eye Diseases, Moscow 119021, Russia
8 shared publications - Sergey Eduardovich Avetisov
Krasnov Research Institute of Eye Disease
7 shared publications - E. I. Fettser
Krasnov Research Institute of Eye Diseases
2 shared publications - K.V. Presnyakova
Krasnov Research Institute of Eye Diseases
2 shared publications - O. V. Eksarenko
Krasnov Research Institute of Eye Diseases
2 shared publications - S. I. Kharlap
Research Institute of Eye Diseases, Moscow, Russia
2 shared publications
Latest Publications
- 16 October 2026
- Published by Media Sphere Publishing Group in Russian Annals of Ophthalmology
- Vol. 142 (5)
Modern diagnostic methods for dislocation of the natural lens
The review presents the findings of studies on the clinical use of ultrasound biomicroscopy and anterior segment optical coherence tomography in the diagnosis of natural lens dislocation.
- 16 October 2026
- Published by Media Sphere Publishing Group in Russian Annals of Ophthalmology
- Vol. 142 (5)
Modern diagnostic methods for dislocation of the natural lens
The review presents the findings of studies on the clinical use of ultrasound biomicroscopy and anterior segment optical coherence tomography in the diagnosis of natural lens dislocation.
- Open Access
- 6 July 2026
- Published by MDPI AG in Biomedicines
- Vol. 14 (7) , 1517
Corneal Nerve Fiber Morphology and Biological Age in Healthy Adults
Background/Objectives: Corneal confocal microscopy (CCM) quantifies subbasal corneal nerve fibers noninvasively and may inform peripheral neuroaging. PhenoAge is a validated clinical measure of biological aging linked to morbidity and mortality risk and therefore provides a geriatric-relevant index of systemic aging. We aimed to assess corneal nerve morphology in clinically healthy adults and determine whether CCM-derived parameters are associated with biological age (PhenoAge) beyond chronological age. Methods: Eighty-four healthy volunteers (22–89 years) underwent CCM. PhenoAge was calculated using the Levine algorithm. Associations with chronological age and PhenoAge were tested using Spearman correlations (eye-specific and participant-level mean of both eyes). Paired inter-eye differences were assessed, and linear mixed-effects models (random intercept for participant; fixed effects for age/PhenoAge and eye) were fitted. Results: Mean chronological age was 50.8 ± 15.5 years, and mean PhenoAge was 47.1 ± 16.3 years. No systematic inter-eye differences were detected (all p > 0.05). Across analyses, older age and higher PhenoAge were associated with lower main corneal nerve fiber measures, most consistently for main-fiber density. Participant-level sensitivity analysis (mean of both eyes) confirmed inverse associations of both chronological age and PhenoAge with main-fiber length and density (all p ≤ 0.035). In mixed-effects models, main-fiber density was associated with chronological age (β = −0.020/year, p = 0.032) and PhenoAge (β = −0.019/year, p = 0.037). Conclusions: CCM-derived corneal nerve morphology demonstrates aging-related patterns in clinically healthy adults. The association between PhenoAge and main-fiber density may suggest a systemic biological aging component and warrants longitudinal validation.
- 6 July 2026
- Published by MDPI AG in Biomedicines
- Vol. 14 (7) , 1517
Open AccessCorneal Nerve Fiber Morphology and Biological Age in Healthy Adults
Background/Objectives: Corneal confocal microscopy (CCM) quantifies subbasal corneal nerve fibers noninvasively and may inform peripheral neuroaging. PhenoAge is a validated clinical measure of biological aging linked to morbidity and mortality risk and therefore provides a geriatric-relevant index of systemic aging. We aimed to assess corneal nerve morphology in clinically healthy adults and determine whether CCM-derived parameters are associated with biological age (PhenoAge) beyond chronological age. Methods: Eighty-four healthy volunteers (22–89 years) underwent CCM. PhenoAge was calculated using the Levine algorithm. Associations with chronological age and PhenoAge were tested using Spearman correlations (eye-specific and participant-level mean of both eyes). Paired inter-eye differences were assessed, and linear mixed-effects models (random intercept for participant; fixed effects for age/PhenoAge and eye) were fitted. Results: Mean chronological age was 50.8 ± 15.5 years, and mean PhenoAge was 47.1 ± 16.3 years. No systematic inter-eye differences were detected (all p > 0.05). Across analyses, older age and higher PhenoAge were associated with lower main corneal nerve fiber measures, most consistently for main-fiber density. Participant-level sensitivity analysis (mean of both eyes) confirmed inverse associations of both chronological age and PhenoAge with main-fiber length and density (all p ≤ 0.035). In mixed-effects models, main-fiber density was associated with chronological age (β = −0.020/year, p = 0.032) and PhenoAge (β = −0.019/year, p = 0.037). Conclusions: CCM-derived corneal nerve morphology demonstrates aging-related patterns in clinically healthy adults. The association between PhenoAge and main-fiber density may suggest a systemic biological aging component and warrants longitudinal validation.
- 29 June 2026
- Published by Media Sphere Publishing Group in Russian Annals of Ophthalmology
- Vol. 142 (3) , 5-12
Mucoperiosteal graft in the correction of paralytic lagophthalmos
Various spacers are used to achieve a higher position for the lower eyelid and reduce the degree of lagophthalmos in chronic facial palsy (CFP). Most authors consider a hard palate mucoperiosteal graft (HPG) to have major advantages over other spacers, particularly minimal shrinkage in the postoperative period. However, only a few publications report possible HPG shrinkage, and their findings are based on subjective assessments. Objective. The study aimed to perform clinical and echographic assessment of the lower eyelid tissues after the use of HPG for the correction of paralytic lagophthalmos (PL). Material and methods. The study included 30 patients (30 eyelids) with CFP and PL. The work involved measurement of biometric parameters of the palpebral fissure and ultrasound examination of the lower eyelid (high-resolution grayscale B-scan ultrasonography, color Doppler mapping with 3D mode, echodensitometry, and ultrasound biomicroscopy) at 6 and 12 months after HPG placement. Results. We observed significant changes in palpebral fissure parameters and improvement in the state of the cornea. The distance from the corneal light reflex to the lower eyelid margin (MRD2) decreased from 7.0±1.2 to 5.7±0.8 mm (p<0.001) after surgery, and the degree of lagophthalmos decreased from 2.75 [0.5; 6.0] to 1.0 [0.0; 3.0] mm (p<0.001). At 6 and 12 months, HPG thickness changed from 2.89±0.65 to 2.82±0.69 mm (p=0.68), height from 6.01±0.47 to 5.84±0.54 mm (p=0.449), and volume from 0.56±0.05 to 0.52±0.74 cm³ (p=0.398); these changes were not statistically significant. We identified features of HPG vascularization up to 12 months after HPG placement. The study also describes the complications of HPG placement. Conclusion. The use of HPG for the correction of PL showed high effectiveness and safety. There was no graft shrinkage during the 12-month follow-up period. The study demonstrates the capabilities of ultrasound methods for assessing the dimensions and biointegration features of HPG.
- 29 June 2026
- Published by Media Sphere Publishing Group in Russian Annals of Ophthalmology
- Vol. 142 (3) , 5-12
Mucoperiosteal graft in the correction of paralytic lagophthalmos
Various spacers are used to achieve a higher position for the lower eyelid and reduce the degree of lagophthalmos in chronic facial palsy (CFP). Most authors consider a hard palate mucoperiosteal graft (HPG) to have major advantages over other spacers, particularly minimal shrinkage in the postoperative period. However, only a few publications report possible HPG shrinkage, and their findings are based on subjective assessments. Objective. The study aimed to perform clinical and echographic assessment of the lower eyelid tissues after the use of HPG for the correction of paralytic lagophthalmos (PL). Material and methods. The study included 30 patients (30 eyelids) with CFP and PL. The work involved measurement of biometric parameters of the palpebral fissure and ultrasound examination of the lower eyelid (high-resolution grayscale B-scan ultrasonography, color Doppler mapping with 3D mode, echodensitometry, and ultrasound biomicroscopy) at 6 and 12 months after HPG placement. Results. We observed significant changes in palpebral fissure parameters and improvement in the state of the cornea. The distance from the corneal light reflex to the lower eyelid margin (MRD2) decreased from 7.0±1.2 to 5.7±0.8 mm (p<0.001) after surgery, and the degree of lagophthalmos decreased from 2.75 [0.5; 6.0] to 1.0 [0.0; 3.0] mm (p<0.001). At 6 and 12 months, HPG thickness changed from 2.89±0.65 to 2.82±0.69 mm (p=0.68), height from 6.01±0.47 to 5.84±0.54 mm (p=0.449), and volume from 0.56±0.05 to 0.52±0.74 cm³ (p=0.398); these changes were not statistically significant. We identified features of HPG vascularization up to 12 months after HPG placement. The study also describes the complications of HPG placement. Conclusion. The use of HPG for the correction of PL showed high effectiveness and safety. There was no graft shrinkage during the 12-month follow-up period. The study demonstrates the capabilities of ultrasound methods for assessing the dimensions and biointegration features of HPG.
- 1 July 2025
- Published by Media Sphere Publishing Group in Russian Annals of Ophthalmology
- Vol. 141 (3) , 20-26
Ultrasound evaluation of eyelid weight placement results
Placement of gold eyelid weights (GWs) is an effective minimally invasive method for protecting the cornea in paralytic lagophthalmos (PL). Potential complications of this surgery include nonspecific inflammatory response (NIR), implant dislocation and eruption, and others. Timely detection, monitoring, and management of these complications require assessment of eyelid tissues, GW capsule and GW position using ultrasonography. Purpose. Sonographic evaluation of the results of GW placement in patients with PL. Material and methods. The study included 20 patients (20 eyelids) with chronic facial palsy (CFP) and PL who underwent ultrasound examination (high-resolution gray-scale B-scan, color Doppler mapping (CDM), three-dimensional color Doppler, echodensitometry, ultrasound biomicroscopy (UBM) of the upper eyelid) in the long-term (2 to 13 years) after the placement of a multi-segment gold eyelid weight made of 999-purity gold (99.99% pure metal). Results. This study characterizes ultrasound diagnostic features that allow determining the GW size and echodensity, GW capsule, anterior lamella, as well as the vascularization of surrounding tissues. The study also describes the imaging features of upper eyelid tissue with proper GW placement in the primary fixation site, and in cases of its dislocation and exposure. Conclusion. Ultrasound imaging methods provide reliable visualization of the GW and upper eyelid tissues in both uncomplicated and complicated cases involving implant disclocation or tendency to exposure. These methods show promise for identifying risk factors for implantation-related complications and require further investigation.
- 1 July 2025
- Published by Media Sphere Publishing Group in Russian Annals of Ophthalmology
- Vol. 141 (3) , 20-26
Ultrasound evaluation of eyelid weight placement results
Placement of gold eyelid weights (GWs) is an effective minimally invasive method for protecting the cornea in paralytic lagophthalmos (PL). Potential complications of this surgery include nonspecific inflammatory response (NIR), implant dislocation and eruption, and others. Timely detection, monitoring, and management of these complications require assessment of eyelid tissues, GW capsule and GW position using ultrasonography. Purpose. Sonographic evaluation of the results of GW placement in patients with PL. Material and methods. The study included 20 patients (20 eyelids) with chronic facial palsy (CFP) and PL who underwent ultrasound examination (high-resolution gray-scale B-scan, color Doppler mapping (CDM), three-dimensional color Doppler, echodensitometry, ultrasound biomicroscopy (UBM) of the upper eyelid) in the long-term (2 to 13 years) after the placement of a multi-segment gold eyelid weight made of 999-purity gold (99.99% pure metal). Results. This study characterizes ultrasound diagnostic features that allow determining the GW size and echodensity, GW capsule, anterior lamella, as well as the vascularization of surrounding tissues. The study also describes the imaging features of upper eyelid tissue with proper GW placement in the primary fixation site, and in cases of its dislocation and exposure. Conclusion. Ultrasound imaging methods provide reliable visualization of the GW and upper eyelid tissues in both uncomplicated and complicated cases involving implant disclocation or tendency to exposure. These methods show promise for identifying risk factors for implantation-related complications and require further investigation.
- 7 March 2024
- Published by Media Sphere Publishing Group in Russian Annals of Ophthalmology
- Vol. 140 (1) , 5-10
Structural and functional features of the eye in Marfan syndrome. Report 1. Changes in the fibrous tunic of the eye
Marfan syndrome (MS) is an orphan hereditary connective tissue disease associated with a mutation in the FBN1 gene, which pathological manifestations are characterized by polysystemic involvement. The fibrillin-1 protein is an integral component of the sclera and cornea of the eye, and in MS its structure is distrubed. PURPOSE This study assesses potential structural and functional changes in the cornea and sclera of a patient with MS. MATERIAL AND METHODS Two groups were formed, comparable in the axial length of the eye and age: the main group — 19 patients (38 eyes) with a verified diagnosis of MS, and the control group — 24 patients (48 eyes) with myopia of varying degrees. The results obtained from MS patients were analyzed depending on the absence or presence of ectopia lentis. In addition to measuring the basic ophthalmological parameters (refraction, axial length, visual acuity), topographic keratometry, anterior segment optical coherence tomography, and ocular response analyzer were used for structural and functional assessment of the cornea and sclera. RESULTS In MS there was a statistically significant increase in the radius of curvature and a decrease in corneal refraction in the central zone compared to the control group. There were no significant differences in central corneal thickness, but there was a significant decrease in the thickness of the sclera in the limbal zone compared to the control group. There were no statistically significant changes in corneal hysteresis and corneal resistance factor in MS. CONCLUSION This study confirmed the previously obtained data on the tendency of the optical power to reliably decrease in MS (flattening of the cornea). This symptom can be considered as a compensatory factor affecting clinical refraction, while the decrease in the thickness of the sclera — as the main reason for aaxial length elongation in MS. There were no clear patterns of dependence of the changes in the cornea and sclera analyzed in this study on the presence or absence of ectopia lentis. Changes in the lens, perhaps, should be regarded only as one of the potential components of the ocular symptom complex in MS.
- 7 March 2024
- Published by Media Sphere Publishing Group in Russian Annals of Ophthalmology
- Vol. 140 (1) , 5-10
Structural and functional features of the eye in Marfan syndrome. Report 1. Changes in the fibrous tunic of the eye
Marfan syndrome (MS) is an orphan hereditary connective tissue disease associated with a mutation in the FBN1 gene, which pathological manifestations are characterized by polysystemic involvement. The fibrillin-1 protein is an integral component of the sclera and cornea of the eye, and in MS its structure is distrubed. PURPOSE This study assesses potential structural and functional changes in the cornea and sclera of a patient with MS. MATERIAL AND METHODS Two groups were formed, comparable in the axial length of the eye and age: the main group — 19 patients (38 eyes) with a verified diagnosis of MS, and the control group — 24 patients (48 eyes) with myopia of varying degrees. The results obtained from MS patients were analyzed depending on the absence or presence of ectopia lentis. In addition to measuring the basic ophthalmological parameters (refraction, axial length, visual acuity), topographic keratometry, anterior segment optical coherence tomography, and ocular response analyzer were used for structural and functional assessment of the cornea and sclera. RESULTS In MS there was a statistically significant increase in the radius of curvature and a decrease in corneal refraction in the central zone compared to the control group. There were no significant differences in central corneal thickness, but there was a significant decrease in the thickness of the sclera in the limbal zone compared to the control group. There were no statistically significant changes in corneal hysteresis and corneal resistance factor in MS. CONCLUSION This study confirmed the previously obtained data on the tendency of the optical power to reliably decrease in MS (flattening of the cornea). This symptom can be considered as a compensatory factor affecting clinical refraction, while the decrease in the thickness of the sclera — as the main reason for aaxial length elongation in MS. There were no clear patterns of dependence of the changes in the cornea and sclera analyzed in this study on the presence or absence of ectopia lentis. Changes in the lens, perhaps, should be regarded only as one of the potential components of the ocular symptom complex in MS.
- 7 March 2024
- Published by Media Sphere Publishing Group in Russian Annals of Ophthalmology
- Vol. 140 (1) , 11-18
Structural and functional features of the eye in Marfan syndrome. Report 2. Changes in the anatomical complex of the lens
Analysis of lens changes in Marfan syndrome (MS), in addition to assessing the position of the lens itself, should include the possibility of examining its supporting and accommodative components (ciliary zonule and ciliary body), or what can be called the entire anatomical complex of the lens. Optical methods of studying the structures of the anterior segment of the eye, due to iris opacity, allow only to analyze the state of the lens within the natural or medically enlarged pupil width. Visualization of the structures located behind the iris is possible with the use of radiation diagnostic methods, in particular ultrasound biomicroscopy (UBM). Purpose. This study assesses the state of the anatomical complex of the lens in MS using UBM. Material and methods. The study was carried out on clinical material previously used by us to analyze changes in the fibrous membrane of the eye in MS. At the first stage, the main (19 patients with MS, 38 eyes) and the control (24 patients with myopia, 48 eyes) groups were formed for comparative evaluation. The formed groups were standardized according to the age of the patients and the axial length of the eye. At the second stage, patients with MS were divided into subgroups depending on the absence or presence of biomicroscopic signs of ectopia lentis (22 and 16 eyes, respectively). For UBM, an ultrasound linear sensor with a scanning frequency of 50 MHz was used (Aviso device, Quantel Medical, France). Various biometric UBM indicators were determined: lens thickness, diameter of the lens, lens-axial length factor, iris-lens angle, iris-lens contact distance, posterior chamber depth, length of the fibers of ciliary zonule, thickness of the ciliary body, sclera-ciliary process angle. Results. There are changes in the anatomical complex of the lens as a whole in MS (in the lens itself, the ciliary zonule, and the ciliary body), which are characterized by an increase in lens thickness and a decrease in the diameter of the lens, an increase in the length of the fibers of the ciliary zonule and a decrease in the thickness of the ciliary body. At the same time, the displacement of the lens detected by optical biomicroscopy (ectopia lentis) can be considered as an advanced stage of changes in the anatomical complex of the lens. Conclusion. UBM provides the possibility of full-fledged visualization of all components of the anatomical complex of the lens in terms of both diagnostics, and monitoring of changes in MS. The question of the advisability of including this method in the algorithm for diagnosing ocular manifestations in order to verify the MS remains open. Possible obstacles may be, on the one hand, related to the need for special and expensive equipment, and on the other hand, the absence of a generally accepted «normal» values of UBM indicators of the anatomical complex of the lens.
- 7 March 2024
- Published by Media Sphere Publishing Group in Russian Annals of Ophthalmology
- Vol. 140 (1) , 11-18
Structural and functional features of the eye in Marfan syndrome. Report 2. Changes in the anatomical complex of the lens
Analysis of lens changes in Marfan syndrome (MS), in addition to assessing the position of the lens itself, should include the possibility of examining its supporting and accommodative components (ciliary zonule and ciliary body), or what can be called the entire anatomical complex of the lens. Optical methods of studying the structures of the anterior segment of the eye, due to iris opacity, allow only to analyze the state of the lens within the natural or medically enlarged pupil width. Visualization of the structures located behind the iris is possible with the use of radiation diagnostic methods, in particular ultrasound biomicroscopy (UBM). Purpose. This study assesses the state of the anatomical complex of the lens in MS using UBM. Material and methods. The study was carried out on clinical material previously used by us to analyze changes in the fibrous membrane of the eye in MS. At the first stage, the main (19 patients with MS, 38 eyes) and the control (24 patients with myopia, 48 eyes) groups were formed for comparative evaluation. The formed groups were standardized according to the age of the patients and the axial length of the eye. At the second stage, patients with MS were divided into subgroups depending on the absence or presence of biomicroscopic signs of ectopia lentis (22 and 16 eyes, respectively). For UBM, an ultrasound linear sensor with a scanning frequency of 50 MHz was used (Aviso device, Quantel Medical, France). Various biometric UBM indicators were determined: lens thickness, diameter of the lens, lens-axial length factor, iris-lens angle, iris-lens contact distance, posterior chamber depth, length of the fibers of ciliary zonule, thickness of the ciliary body, sclera-ciliary process angle. Results. There are changes in the anatomical complex of the lens as a whole in MS (in the lens itself, the ciliary zonule, and the ciliary body), which are characterized by an increase in lens thickness and a decrease in the diameter of the lens, an increase in the length of the fibers of the ciliary zonule and a decrease in the thickness of the ciliary body. At the same time, the displacement of the lens detected by optical biomicroscopy (ectopia lentis) can be considered as an advanced stage of changes in the anatomical complex of the lens. Conclusion. UBM provides the possibility of full-fledged visualization of all components of the anatomical complex of the lens in terms of both diagnostics, and monitoring of changes in MS. The question of the advisability of including this method in the algorithm for diagnosing ocular manifestations in order to verify the MS remains open. Possible obstacles may be, on the one hand, related to the need for special and expensive equipment, and on the other hand, the absence of a generally accepted «normal» values of UBM indicators of the anatomical complex of the lens.
- 28 August 2023
- Published by Media Sphere Publishing Group in Russian Annals of Ophthalmology
- Vol. 139 (4) , 59-64
Endocapsular fixation of intraocular lens in patients with ectopia lentis and Marfan syndrome (case study)
Modern trends in advancement of phaco surgery techniques in patients with ectopia lentis (including patients with Marfan syndrome) are characterized by the transition from complete removal of the lens (lensectomy) to aspiration of the lens substance and attempts to preserve and reposition the capsular bag. This case study analyzes the results of surgical treatment of bilateral ectopia lentis in a 6-year-old patient with Marfan syndrome. The specifics of microinvasive phaco surgery consisted in capsular bag preservation and endocapsular fixation of the intraocular lens. The article presents the results of ophthalmological observation over a seven-year period.
- 28 August 2023
- Published by Media Sphere Publishing Group in Russian Annals of Ophthalmology
- Vol. 139 (4) , 59-64
Endocapsular fixation of intraocular lens in patients with ectopia lentis and Marfan syndrome (case study)
Modern trends in advancement of phaco surgery techniques in patients with ectopia lentis (including patients with Marfan syndrome) are characterized by the transition from complete removal of the lens (lensectomy) to aspiration of the lens substance and attempts to preserve and reposition the capsular bag. This case study analyzes the results of surgical treatment of bilateral ectopia lentis in a 6-year-old patient with Marfan syndrome. The specifics of microinvasive phaco surgery consisted in capsular bag preservation and endocapsular fixation of the intraocular lens. The article presents the results of ophthalmological observation over a seven-year period.
- 16 March 2023
- Published by Media Sphere Publishing Group in Russian Annals of Ophthalmology
- Vol. 139 (1) , 129-136
Hereditary ectopia lentis: diagnosis and surgical treatment
This review describes hereditary diseases in which ectopia lentis may be present as one of the symptoms, considers the basic diagnostic concepts of lens disposition, and analyzes the options in surgical treatment of ectopia lentis and optical correction of aphakia.
- 16 March 2023
- Published by Media Sphere Publishing Group in Russian Annals of Ophthalmology
- Vol. 139 (1) , 129-136
Hereditary ectopia lentis: diagnosis and surgical treatment
This review describes hereditary diseases in which ectopia lentis may be present as one of the symptoms, considers the basic diagnostic concepts of lens disposition, and analyzes the options in surgical treatment of ectopia lentis and optical correction of aphakia.
- 1 January 2022
- Published by Media Sphere Publishing Group in Russian Annals of Ophthalmology
- Vol. 138 (4)
Ocular manifestations of Marfan syndrome
- 1 January 2022
- Published by Media Sphere Publishing Group in Russian Annals of Ophthalmology
- Vol. 138 (4)
Ocular manifestations of Marfan syndrome
- 1 January 2022
- Published by Media Sphere Publishing Group in Russian Annals of Ophthalmology
- Vol. 138 (4) , 94-100
Ocular manifestations of Marfan syndrome
Синдром Марфана — орфанное заболевание, которое вызывается мутацией в расположенном на 15-й хромосоме (15q21.1) гене FBN1 и, как правило, наследуется аутосомно-доминантным путем. В обзоре представлены результаты исследований, касающиеся потенциальных глазных проявлений синдрома Марфана.
- 1 January 2022
- Published by Media Sphere Publishing Group in Russian Annals of Ophthalmology
- Vol. 138 (4) , 94-100
Ocular manifestations of Marfan syndrome
Синдром Марфана — орфанное заболевание, которое вызывается мутацией в расположенном на 15-й хромосоме (15q21.1) гене FBN1 и, как правило, наследуется аутосомно-доминантным путем. В обзоре представлены результаты исследований, касающиеся потенциальных глазных проявлений синдрома Марфана.