PMPaweł Mikrut

Paweł Mikrut

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Paweł Mikrut has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Influence of Loaded Power Cable Cyclic Transversal Bending on Trend Evolution of Dielectric Loss and Partial Discharges

    by Marek Florkowski, Maciej Kuniewski, Pawel Mikrut

    Zero-emission goals necessitate future global energy strategies to rely on renewable energy sources. As a result, significant investments are being directed toward large-scale offshore wind farms around the world. This has led to substantial advancements and growing demand for submarine cables for linking these offshore farms to the power grids (especially, a new class that refers to floating cables that are exposed to cyclic or fluctuating mechanical stresses). In this article, investigations on the influence of a loaded power cable's transversal bending on its performance indicators during cyclic transversal bending are presented. During the tests, phase-resolved partial discharge (PD), dielectric-loss, and cable temperature measurements were simultaneously performed. The original concept was a real-time synchronous correlation of the above markers recorded up to the cable's electrical breakdown during consecutive bending cycles. The loaded cable temperature evolution was analyzed in correlation with the performance indicators and the number of bending cycles. The article presents an original methodology for measuring and assessing trends, along with a quantitative framework for analyzing the degradation of dynamic cables. The individual stages of cable degradation, such as the cracking of the wires in both the cable core and the outer screen as well as insulation deterioration, were identified and correlated with the dielectric loss waveforms and PD patterns. The methodology and results may contribute to the testing and diagnostics of dynamic power cables that are exposed to frequent mechanical movements during normal operations, such as in industry, mining, and (particularly) subsea applications. This is especially relevant for future submarine dynamic cables, which will demand enhanced mechanical and electrical durability.

  • Effect of Phase Angle of High-Voltage Harmonics on PD Power Losses

    by Marek Florkowski, Maciej Kuniewski, Paweł Mikrut

    Interpretation of dielectric losses is critical for high-voltage insulation reliability and long-term endurance. Electrical insulation in various sectors, such as power grids and transportation electrification, is exposed to high voltages (HV) containing harmonics due to ubiquitous power electronic-based conversions, non-linear elements, and transients. This letter highlights the contribution of partial discharge (PD)-related power losses. In particular, it presents a methodology for the quantitative extraction of PD-related power losses caused by HV harmonics, as well as the role of the phase angle in either amplifying or attenuating these components. The investigation is performed on a polyethylene specimen, typical for HV insulation. The results clearly indicate the influence of the harmonic phase angle on the quantitative contribution to PD power losses. The presented methodology can be useful both in the design of HV insulation systems and for diagnostic purposes.


  • Open Access

    Numerical Analysis of Conditions for Partial Discharge Inception in Spherical Gaseous Voids in XLPE Insulation of AC Cables at Rated Voltage and During AC, VLF and DAC Tests

    by Paweł Mikrut, Paweł Zydroń

    AC power cables play an important role in power systems, in the transmission and distribution of electrical energy. For this reason, to ensure high operational reliability, voltage withstand tests and diagnostic tests are performed at every stage of their technical life to determine the condition of cable insulation. Due to the large electrical capacitances of cable systems, modern testing methods use very low frequency (VLF) and damped oscillating (DAC) voltages. The research presented in the article analyzed the effect of the test voltage waveform parameters on the partial discharge (PD) inception conditions in spherical gaseous voids present in the XLPE insulation of AC cable model. Using COMSOL 6.1 and MATLAB R2021b, a coupled electro-thermal model of a 110 kV AC cable was implemented, for which the critical gaseous void dimensions were estimated and phase-resolved PD patterns were generated for the rated voltage and the VLF and DAC test voltages specified in the relevant standards. In the analyses for the rated voltage, the influence of internal temperature distribution, which causes modification of XLPE permittivity, was taken into account in the numerical cable model.


  • Effects of Mechanical Transversal Bending of Power Cable on Partial Discharges and Dielectric-Loss Evolution

    by Marek Florkowski, Maciej Kuniewski, Paweł Mikrut

    In this article, investigations of transversal power cable bending cycles on dielectric performance are presented. The effects were assessed by two electrical methods: phase-resolved partial discharge (PD) measurements, and dielectric-loss measurements. The original element was a real-time synchronous correlation of these indicators over consecutive bending cycles up to the electrical breakdown of the cable’s insulation. In addition, the impact of the mechanical stress was observed on the bending moment. The article depicts an original measurement and assessment methodology for trend monitoring and a quantitative approach for evaluating dynamic cable deterioration. The evolution of the dissipation factor while applying consecutive transversal bending cycles revealed a strong correlation with the deterioration progress. Just prior to breakdown stage (at 500 bending cycles), the dielectric loss factor rise was observed from 0.009 to 0.014. A similar strong correlation was obtained for the dropping trends of the PD-inception voltage and PD-pattern transformations. The inception voltage decreased from 10 kV to even below 4 kV just before breakdown. The study may contribute to the testing and diagnostics of dynamic power cables that are subjected to many mechanical movements under normal operation conditions; e.g., in industry, mining, and especially in subsea applications. This especially refers to future submarine dynamic cables, which will require extended mechanical and electrical endurance.


  • Open Access

    Control of Dielectric Parameters of Micro- and Nanomodified Epoxy Resin Using Electrophoresis

    by Anna Dąda, Paweł Błaut, Paweł Mikrut, Maciej Kuniewski, Paweł Zydroń

    This work presents the results of research on submicro- and nanocomposites with gradient properties, produced in a planned electrophoretic process. Epoxy-resin-based samples were filled with TiO2 particles of three different sizes (13 nm, 38 nm, and Eav (0.0 Vmm−1, 125 Vmm−1, 250 Vmm−1, and 500 Vmm−1) for 1 h each. Changes in selected dielectric parameters (dielectric constant εr and dielectric loss factor tanδ) of the composites were analyzed using broadband dielectric spectroscopy (10−1 Hz to 105 Hz). The influence of the Eav and the current i(t) flowing through the sample material and the Joule heat generated in it on the resin curing process and the final gradient of dielectric parameters were investigated. The results show that the degree of modification of the εr gradient increases with increasing Eav and is more pronounced in the case of TiO2 nanoparticles. The largest modifications in the εr and tanδ were obtained for nanoparticles with a diameter of 13 nm at Eav = 500 Vmm−1, while the lowest for particles < 1 µm at Eav = 125 Vmm−1. The effect of electrophoresis on the dielectric parameters is significant, especially near the anode region. Increasing the concentration of TiO2 particles at the anode occurs at the expense of reducing their concentration in the remaining volume of the sample. The test results clearly demonstrate the importance of particle dimension and electric field strength for the gradient modification of the properties of the epoxy composite using electrophoresis. Numerical simulations of electric field stresses in the epoxy resin during the electrophoresis process, performed in the COMSOL program, revealed a significant increase in the E field strength in the areas close to the anode and cathode.


  • Open Access

    Numerical Modeling of PD Pulses Formation in a Gaseous Void Located in XLPE Insulation of a Loaded HVDC Cable

    by Paweł Mikrut, Paweł Zydroń

    Power cables are one of the key components of fast-growing HVDC transmission systems. The long-term reliability of HVDC cables is closely related to the occurrence of partial discharges (PDs) in their insulation systems. The article analyzes the conditions for the formation of PD pulses in gaseous voids located in the XLPE insulation of an HVDC cable. For this purpose, the MATLAB® procedure and the coupled electro-thermal simulation model implemented in COMSOL Multiphysics® software were used. The FEM model was used to study the effect of the applied voltage, the temperature field (created in the insulation of the loaded cable) and the location of the gaseous void (on cable radius) in the distribution and values of the electric field in the cable insulation. The model takes into account the influence of temperature and the electric field on the conductivity of the insulating material and relates the value of the PD inception field to the temperature/pressure of the gas inside the void. In the numerical simulation procedure, the time sequences of PDs arising in the gaseous defects of the HVDC cable insulation were analyzed, by observing changes caused by the increase in the temperature of the cable core. The model was used for a study of conditions for PD formation in models of three HVDC cables, for DC voltages from 150 kV to 500 kV. The critical dimensions of gaseous voids were also estimated for each of the analyzed cables, i.e., the dimension which, if exceeded, makes a void a source of PD.


  • Wybrane problemy inżynierii i diagnostyki wysokonapięciowej we współczesnej elektroenergetyce

    by Marek Florkowski, Jakub Furgał, Paweł Zydroń, Maciej Kuniewski, Piotr Pająk, Józef Roehrich, Michał Bonk, Paweł Mikrut