Yanping Zhu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yanping Zhu has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Deming Kong
School of Electrical Engineering, Yanshan University, Qinhuangdao, China
2 shared publications Chuanjin Cui
College of Electrical Engineering, North China University of Science and Technology, Tangshan, China
1 shared publication- Chuanjin Cui
College of Electrical Engineering, North China University of Science and Technology, Tangshan, China
1 shared publication Fubin Wang
College of Electrical Engineering, North China University of Science and Technology, Tangshan, China
1 shared publicationJiahao Yin
1 shared publicationJiangtao Lv
1 shared publication
Latest Publications
- 18 February 2025
- Published by Elsevier in Measurement
- Vol. 249
Study on oil spill emulsification degree based on 3D fluorescence spectra combined with multi-modal attention feature fusion
- 18 February 2025
- Published by Elsevier in Measurement
- Vol. 249
Study on oil spill emulsification degree based on 3D fluorescence spectra combined with multi-modal attention feature fusion
- Open Access
- 28 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 103733-103748
Determination of Oil Pollutants by Microchannel Laser Induced Fluorescence Technology
Laser-induced fluorescence technology is an effective method for detecting oil pollutants. The laser induced fluorescence detection system was developed, and four parallel microchannel sample pools were designed to improve the detection accuracy of fluorescence signals. The grating scanning system is improved by introducing grating feedback link to improve the wavelength scanning accuracy of the system.The experimental results show that the wavelength scanning resolution of the microchannel laser-induced fluorescence detection system is improved by 0.4 nm. Aiming at the defects of the traditional parallel factor algorithm which is sensitive to the sample components, slow operation speed and easy to fall into local convergence, the generalized inverse singular value decomposition is used to improve the parallel factor algorithm. Configure different concentrations of diesel, gasoline and kerosene solution samples. The experimental verification shows that the excitation-emission spectra of each component obtained by the improved parallel factor algorithm are highly consistent with the measured spectral characteristics, indicating that the microchannel laser-induced fluorescence detection system combined with the improved parallel factor analysis method can accurately identify oil pollutants.
- 28 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 103733-103748
Open AccessDetermination of Oil Pollutants by Microchannel Laser Induced Fluorescence Technology
Laser-induced fluorescence technology is an effective method for detecting oil pollutants. The laser induced fluorescence detection system was developed, and four parallel microchannel sample pools were designed to improve the detection accuracy of fluorescence signals. The grating scanning system is improved by introducing grating feedback link to improve the wavelength scanning accuracy of the system.The experimental results show that the wavelength scanning resolution of the microchannel laser-induced fluorescence detection system is improved by 0.4 nm. Aiming at the defects of the traditional parallel factor algorithm which is sensitive to the sample components, slow operation speed and easy to fall into local convergence, the generalized inverse singular value decomposition is used to improve the parallel factor algorithm. Configure different concentrations of diesel, gasoline and kerosene solution samples. The experimental verification shows that the excitation-emission spectra of each component obtained by the improved parallel factor algorithm are highly consistent with the measured spectral characteristics, indicating that the microchannel laser-induced fluorescence detection system combined with the improved parallel factor analysis method can accurately identify oil pollutants.
- Open Access
- 19 August 2022
- Published by SAGE Publications in Measurement and Control
- Vol. 55 (9-10) , 1078-1087
Determination of oil pollutants by three-dimensional fluorescence spectroscopy combined with improved pattern recognition algorithm
Petroleum refineries are one of the main sources of hazardous air pollutants, so the accurate determination of petroleum pollutants is of great significance to maintain ecological balance. In this study, three-dimensional (3D) fluorescence spectroscopy combined with pattern recognition algorithm is adopted to distinguish the composition and content of oil pollutants efficiently and accurately. Three hundred samples of kerosene, diesel, and gasoline mixed solutions with different concentrations are prepared. The principal component analysis is used to extract the optimal feature variables, and the correlation coefficient method is used to obtain eight groups of principal component features in the spectra. The dimension is selected as 8, and the principal component score is calculated, which is used as the input data of the extension neural network. Next, the pattern recognition method is improved, and the designed neural network has functions of both resolution and measurement. The results of neural network pattern recognition are used as the input of the concentration network. The first 270 samples are used as the training samples to train the network model, and the remaining 30 samples are used as test samples, which are applied to the input layer of the trained neural network. The relative fluorescence intensity, relative slope, and comprehensive background parameters are used as the input parameters, and the extension neural network is used for pattern recognition and evaluation of oil pollutants. The experimental results show that the average recognition rate of the improved pattern recognition algorithm for oil pollutants is 98.43%, and the average recovery rate of concentration is 98.67%. Further, the average time for pattern recognition is 1.53 s, while the parallel factor analysis algorithm takes 2.89 s. This suggests that the improved extension neural network is an effective and reliable pattern recognition method for the identification of mixed oil pollutants.
- 19 August 2022
- Published by SAGE Publications in Measurement and Control
- Vol. 55 (9-10) , 1078-1087
Open AccessDetermination of oil pollutants by three-dimensional fluorescence spectroscopy combined with improved pattern recognition algorithm
Petroleum refineries are one of the main sources of hazardous air pollutants, so the accurate determination of petroleum pollutants is of great significance to maintain ecological balance. In this study, three-dimensional (3D) fluorescence spectroscopy combined with pattern recognition algorithm is adopted to distinguish the composition and content of oil pollutants efficiently and accurately. Three hundred samples of kerosene, diesel, and gasoline mixed solutions with different concentrations are prepared. The principal component analysis is used to extract the optimal feature variables, and the correlation coefficient method is used to obtain eight groups of principal component features in the spectra. The dimension is selected as 8, and the principal component score is calculated, which is used as the input data of the extension neural network. Next, the pattern recognition method is improved, and the designed neural network has functions of both resolution and measurement. The results of neural network pattern recognition are used as the input of the concentration network. The first 270 samples are used as the training samples to train the network model, and the remaining 30 samples are used as test samples, which are applied to the input layer of the trained neural network. The relative fluorescence intensity, relative slope, and comprehensive background parameters are used as the input parameters, and the extension neural network is used for pattern recognition and evaluation of oil pollutants. The experimental results show that the average recognition rate of the improved pattern recognition algorithm for oil pollutants is 98.43%, and the average recovery rate of concentration is 98.67%. Further, the average time for pattern recognition is 1.53 s, while the parallel factor analysis algorithm takes 2.89 s. This suggests that the improved extension neural network is an effective and reliable pattern recognition method for the identification of mixed oil pollutants.