Baha Erim Uzunoğlu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Baha Erim Uzunoğlu has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Amay Jairaj Bandodkar
Department of Electrical and Computer Engineering, North Carolina State University, Raleigh, NC, USA
2 shared publications - Rajaram Kaveti
Department of Electrical and Computer Engineering, North Carolina State University, Raleigh, NC 27606, USA
2 shared publications - Abraham Vázquez-Guardado
Department of Electrical and Computer Engineering North Carolina State University Raleigh North Carolina USA
1 shared publication - Adrian Rodriguez-Kattan
Department of Electrical and Computer Engineering, North Carolina State University, Raleigh, NC 27606, USA
1 shared publication Akshay Bhardwaj
Department of Electrical and Computer Engineering, North Carolina State University, Raleigh, NC 27606, USA
1 shared publication- Aristidis Veves
Joslin-Beth Israel Deaconess Foot Center and The Rongxiang Xu, MD, Center for Regenerative Therapeutics, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, USA
1 shared publication
Latest Publications
- Open Access
- 3 July 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (27) , eaee2065
Safe, high-performance, moisture-activated batteries for powering next-generation Internet-of-Things devices
Conventional batteries are heavy, nonconformal, and toxic, while energy harvesters offer low/variable power, rendering them unsuitable for emerging wearable, robotic, and other Internet-of-Things (IoT) devices. Here, we introduce a nontoxic, thin-film battery superior to several commercial batteries inspired by advances in water harvesting techniques. It scavenges ambient moisture to serve as its electrolyte, combining features of an energy harvester with attractive features of a battery (stable and high power). It functions in a wide range of environments and offers an open-circuit voltage of ~1.6 volts, specific capacity of ~52 milliampere-hours per gram, and specific energy of ~81 milliwatt-hours per gram. Unique pangolin skin–mimicking design imparts high flexibility, stretchability, and fill factor to the battery, ensuring conformability without compromising on capacity. Experimental and computer simulation studies reveal the distinctive materials and design features responsible for the battery’s impressive performance. Examples of a wireless wearable pulse oximeter and surveillance monitor with a unique kill switch that secures it from unauthorized access demonstrate the versatility of the battery to power various IoT devices.
- 3 July 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (27) , eaee2065
Open AccessSafe, high-performance, moisture-activated batteries for powering next-generation Internet-of-Things devices
Conventional batteries are heavy, nonconformal, and toxic, while energy harvesters offer low/variable power, rendering them unsuitable for emerging wearable, robotic, and other Internet-of-Things (IoT) devices. Here, we introduce a nontoxic, thin-film battery superior to several commercial batteries inspired by advances in water harvesting techniques. It scavenges ambient moisture to serve as its electrolyte, combining features of an energy harvester with attractive features of a battery (stable and high power). It functions in a wide range of environments and offers an open-circuit voltage of ~1.6 volts, specific capacity of ~52 milliampere-hours per gram, and specific energy of ~81 milliwatt-hours per gram. Unique pangolin skin–mimicking design imparts high flexibility, stretchability, and fill factor to the battery, ensuring conformability without compromising on capacity. Experimental and computer simulation studies reveal the distinctive materials and design features responsible for the battery’s impressive performance. Examples of a wireless wearable pulse oximeter and surveillance monitor with a unique kill switch that secures it from unauthorized access demonstrate the versatility of the battery to power various IoT devices.
- Open Access
- 9 August 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (32) , eado7538
Water-powered, electronics-free dressings that electrically stimulate wounds for rapid wound closure
Chronic wounds affect ~2% of the U.S. population and increase risks of amputation and mortality. Unfortunately, treatments for such wounds are often expensive, complex, and only moderately effective. Electrotherapy represents a cost-effective treatment; however, its reliance on bulky equipment limits its clinical use. Here, we introduce water-powered, electronics-free dressings (WPEDs) that offer a unique solution to this issue. The WPED performs even under harsh conditions—situations wherein many present treatments fail. It uses a flexible, biocompatible magnesium-silver/silver chloride battery and a pair of stimulation electrodes; upon the addition of water, the battery creates a radial electric field. Experiments in diabetic mice confirm the WPED’s ability to accelerate wound closure and promote healing by increasing epidermal thickness, modulating inflammation, and promoting angiogenesis. Across preclinical wound models, the WPED-treated group heals faster than the control with wound closure rates comparable to treatments requiring expensive biologics and/or complex electronics. The results demonstrate the WPED’s potential as an effective and more practical wound treatment dressing.
- 9 August 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (32) , eado7538
Open AccessWater-powered, electronics-free dressings that electrically stimulate wounds for rapid wound closure
Chronic wounds affect ~2% of the U.S. population and increase risks of amputation and mortality. Unfortunately, treatments for such wounds are often expensive, complex, and only moderately effective. Electrotherapy represents a cost-effective treatment; however, its reliance on bulky equipment limits its clinical use. Here, we introduce water-powered, electronics-free dressings (WPEDs) that offer a unique solution to this issue. The WPED performs even under harsh conditions—situations wherein many present treatments fail. It uses a flexible, biocompatible magnesium-silver/silver chloride battery and a pair of stimulation electrodes; upon the addition of water, the battery creates a radial electric field. Experiments in diabetic mice confirm the WPED’s ability to accelerate wound closure and promote healing by increasing epidermal thickness, modulating inflammation, and promoting angiogenesis. Across preclinical wound models, the WPED-treated group heals faster than the control with wound closure rates comparable to treatments requiring expensive biologics and/or complex electronics. The results demonstrate the WPED’s potential as an effective and more practical wound treatment dressing.
- 18 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 31 (5) , 741-752
A Ring Gyroscope With On-Chip Capacitive Stress Compensation
We present long-term stress compensation results for a 3.2mm diameter ring gyroscope integrated with 16 capacitive stress sensors for the first time in this work. A bridge-type capacitive sensor is preferred due to its compact size and temperature insensitivity for on-chip stress measurements. The ring design enables a high level of integration and stress sensor-gyroscope output correlation. We first demonstrate the stress sensor operation on a stress test-bed. The drift test for sixteen days at mismatched mode and the drift test for eight days at matched mode in room temperature reveal that the stress compensation can eliminate the gyroscope drift. The stability of the stress compensated gyroscope output can reach 0.008°/h in mismatched mode and 0.003°/h in matched mode at an averaging time of two days with no signs of long-term drift. High gyroscope stability is achieved with a partial least-squares fitting algorithm; however, we believe that stress and gyroscope output relation might be linear time-variant with possible nonlinear and hysteresis effects. Analysis of the drive and sense mode frequencies shows that only temperature cannot explain the frequency variations, and the inclusion of stress can comprehensively describe the frequency changes. [2022-0108]
- 18 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 31 (5) , 741-752
A Ring Gyroscope With On-Chip Capacitive Stress Compensation
We present long-term stress compensation results for a 3.2mm diameter ring gyroscope integrated with 16 capacitive stress sensors for the first time in this work. A bridge-type capacitive sensor is preferred due to its compact size and temperature insensitivity for on-chip stress measurements. The ring design enables a high level of integration and stress sensor-gyroscope output correlation. We first demonstrate the stress sensor operation on a stress test-bed. The drift test for sixteen days at mismatched mode and the drift test for eight days at matched mode in room temperature reveal that the stress compensation can eliminate the gyroscope drift. The stability of the stress compensated gyroscope output can reach 0.008°/h in mismatched mode and 0.003°/h in matched mode at an averaging time of two days with no signs of long-term drift. High gyroscope stability is achieved with a partial least-squares fitting algorithm; however, we believe that stress and gyroscope output relation might be linear time-variant with possible nonlinear and hysteresis effects. Analysis of the drive and sense mode frequencies shows that only temperature cannot explain the frequency variations, and the inclusion of stress can comprehensively describe the frequency changes. [2022-0108]