JLJianwei Liao

Jianwei Liao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jianwei Liao has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Development of a Time Projection Chamber Readout with Hybrid Pixel Sensors for Beam Monitoring

    by Yingdong Song, Haibo Yang, Yuezhao Zhang, Jianwei Liao, Yanhao Jia, Peng Ma, Yufeng Hou, Xiangming Sun, Hulin Wang, Haisheng Song, et al.

    To monitor the position and profile of therapeutic carbon beams in real-time, in this paper, we proposed a system called HiBeam-T. The HiBeam-T is a time projection chamber (TPC) with forty Topmetal-II- CMOS pixel sensors as its readout. Each Topmetal-II- has 72 × 72 pixels with the size of 83 μm × 83 μm. The detector consists of the charge drift region and the charge collection area. The readout electronics comprise three Readout Control Modules and one Clock Synchronization Module. This Hibeam-T has a sensitive area of 20 × 20 cm and can acquire the center of the incident beams. The test with a continuous 80.55 MeV/u 12C6+ beam shows that the measurement resolution to the beam center could reach 6.45 μm for unsaturated beam projections.

  • Open Access

    Readout Electronics of the Prototype Beam Monitor in the HIRFL-CSR External-Target Experiment

    by Haibo Yang, Jianwei Liao, Hulin Wang, Chaosong Gao, Honglin Zhang, Wenchao Sun, Xianqin Li, Chengxin Zhao

    The External-target Experiment (CEE) at the Cooling Storage Ring of the Heavy-Ion Research Facility in Lanzhou (HIRFL-CSR) will be the first large-scale experiment in nuclear physics independently developed in China covering the GeV energy regime. The beam monitor located at the center front of the CEE accurately measures the position of the particles with a few tens of um accuracy in a non-interceptive way. This unique advantage significantly improves the accuracy of the particle track reconstructions. This beam monitor’s readout electronics consist of the Front-end module (FEM), Readout Control Module (RCM), and Clock Synchronization module (CSM). Twhe novel Topmetal series pixel sensors directly collect the ionized charge along the track of the ion beam while it passes through the gas in the beam monitor. Lab test proves that the readout electronics have an INL of less than 1%. In addition, the prototype beam monitor can measure the position of the 40Ar beam of 320 MeV/u with a resolution of ~6.9 μm. This paper will discuss the design, characterization, and test of the readout electronics.