Michael Kohler
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Michael Kohler has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Fang Li
Department of Mechanical Engineering, New York Institute of Technology, Old Westbury, NY, USA
3 shared publications - Reza Khalaj Amineh
Department of Electrical and Computer Engineering, New York Institute of Technology, New York, NY 10023, USA
2 shared publications - Ziqian Dong
Department of Electrical and Computer Engineering, New York Institute of Technology, New York, NY, USA
2 shared publications Britta Neuweger
Bremer Umweltinstitut GmbH, Germany
1 shared publicationChris Vanessa Sumowski
Bremer Umweltinstitut GmbH, Germany
1 shared publication- Fernando Camino
Center for Functional Nanomaterials, Brookhaven National Laboratory 1 , Upton, New York 11973
1 shared publication
Latest Publications
- 30 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (24) , 43690-43701
Temperature and Strain Sensing Characteristics of a 128° YX-Cut LiNbO 3 Rayleigh-Mode SAW Sensor From Room to Cryogenic Temperatures
Accurate, passive, and wireless monitoring of cryogenic hardware is essential for high-energy physics, space propulsion, and biomedical instrumentation. This study quantifies the coupled temperature–strain behavior of Rayleigh-mode surface acoustic-wave (SAW) delay-line sensors fabricated on 128◦ YX-cut LiNbO3. A nonlinear finite-element (FE) model incorporating Varshni-based elastic constants, higher order thermal expansion, and temperature-dependent piezoelectric and dielectric coefficients was developed and validated experimentally between 280 and 80 K. Free-standing (first test condition) and bonded/wired (second test condition) devices exhibited indistinguishable thermal responses; the average temperature coefficient of delay (TCD) in the critical cryogenic range from 130 down to 80K differed by only 0.15ppm/K (0.32%), confirming that bonding-induced stress is negligible. Over 280–80 K, the measured TCD was 61.77 ppm/K, while the FE model predicted an equivalent temperature coefficient of frequency (TCF) of −62.74 ppm/K with an overall coefficient of determination R2 = 0.998. In the critical cryogenic interval 130–80 K, the TCD fell to 47.66 ppm/K, indicating improved thermal stability at low temperature. Controlled loading (0–300 με) revealed a strain coefficient of delay (SCD) that rises from 0.53 ± 0.02ppm/με at 300K to 1.05 ± 0.02ppm/με at 80 K. This modest sensitivity confirms that, for temperature sensing, strain is a second-order perturbation above 135K but must be compensated at deeper cryogenic levels. Overall, this work establishes a predictive multiphysics model together with repeatable wired measurements that confirm the suitability of SAWsensors for temperature and strain monitoring in extreme cryogenic environments while also providing a baseline for future wireless implementations.
- 30 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (24) , 43690-43701
Temperature and Strain Sensing Characteristics of a 128° YX-Cut LiNbO 3 Rayleigh-Mode SAW Sensor From Room to Cryogenic Temperatures
Accurate, passive, and wireless monitoring of cryogenic hardware is essential for high-energy physics, space propulsion, and biomedical instrumentation. This study quantifies the coupled temperature–strain behavior of Rayleigh-mode surface acoustic-wave (SAW) delay-line sensors fabricated on 128◦ YX-cut LiNbO3. A nonlinear finite-element (FE) model incorporating Varshni-based elastic constants, higher order thermal expansion, and temperature-dependent piezoelectric and dielectric coefficients was developed and validated experimentally between 280 and 80 K. Free-standing (first test condition) and bonded/wired (second test condition) devices exhibited indistinguishable thermal responses; the average temperature coefficient of delay (TCD) in the critical cryogenic range from 130 down to 80K differed by only 0.15ppm/K (0.32%), confirming that bonding-induced stress is negligible. Over 280–80 K, the measured TCD was 61.77 ppm/K, while the FE model predicted an equivalent temperature coefficient of frequency (TCF) of −62.74 ppm/K with an overall coefficient of determination R2 = 0.998. In the critical cryogenic interval 130–80 K, the TCD fell to 47.66 ppm/K, indicating improved thermal stability at low temperature. Controlled loading (0–300 με) revealed a strain coefficient of delay (SCD) that rises from 0.53 ± 0.02ppm/με at 300K to 1.05 ± 0.02ppm/με at 80 K. This modest sensitivity confirms that, for temperature sensing, strain is a second-order perturbation above 135K but must be compensated at deeper cryogenic levels. Overall, this work establishes a predictive multiphysics model together with repeatable wired measurements that confirm the suitability of SAWsensors for temperature and strain monitoring in extreme cryogenic environments while also providing a baseline for future wireless implementations.
- Open Access
Real-Time Nitrate Ion Monitoring with Poly(3,4-ethylenedioxythiophene) (PEDOT) Materials
Nitrate (NO3) pollution in groundwater, caused by various factors both natural and synthetic, contributes to the decline of human health and well-being. Current techniques used for nitrate detection include spectroscopic, electrochemical, chromatography, and capillary electrophoresis. It is highly desired to develop a simple cost-effective alternative to these complex methods for nitrate detection. Therefore, a real-time poly (3,4-ethylenedioxythiophene) (PEDOT)-based sensor for nitrate ion detection via electrical property change is introduced in this study. Vapor phase polymerization (VPP) is used to create a polymer thin film. Variations in specific parameters during the process are tested and compared to develop new insights into PEDOT sensitivity towards nitrate ions. Through this study, the optimal fabrication parameters that produce a sensor with the highest sensitivity toward nitrate ions are determined. With the optimized parameters, the electrical resistance response of the sensor to 1000 ppm nitrate solution is 41.79%. Furthermore, the sensors can detect nitrate ranging from 1 ppm to 1000 ppm. The proposed sensor demonstrates excellent potential to detect the overabundance of nitrate ions in aqueous solutions in real time.
Open AccessReal-Time Nitrate Ion Monitoring with Poly(3,4-ethylenedioxythiophene) (PEDOT) Materials
Nitrate (NO3) pollution in groundwater, caused by various factors both natural and synthetic, contributes to the decline of human health and well-being. Current techniques used for nitrate detection include spectroscopic, electrochemical, chromatography, and capillary electrophoresis. It is highly desired to develop a simple cost-effective alternative to these complex methods for nitrate detection. Therefore, a real-time poly (3,4-ethylenedioxythiophene) (PEDOT)-based sensor for nitrate ion detection via electrical property change is introduced in this study. Vapor phase polymerization (VPP) is used to create a polymer thin film. Variations in specific parameters during the process are tested and compared to develop new insights into PEDOT sensitivity towards nitrate ions. Through this study, the optimal fabrication parameters that produce a sensor with the highest sensitivity toward nitrate ions are determined. With the optimized parameters, the electrical resistance response of the sensor to 1000 ppm nitrate solution is 41.79%. Furthermore, the sensors can detect nitrate ranging from 1 ppm to 1000 ppm. The proposed sensor demonstrates excellent potential to detect the overabundance of nitrate ions in aqueous solutions in real time.
- Open Access
Software Defined Radio-Based Wireless Sensing System
In this paper, we investigate the application of using software-defined radio (SDR) and surface acoustic wave (SAW) device for wireless measurement of the response of in situ sensors. SDR uses software to realize different communication functions. After collecting the magnitude and phase of the response at discrete frequencies, we apply inverse Fourier transform to analyze the time domain responses which, in turn, allows for monitoring the changes of the response of the in situ sensor. We employ microwave signal flow graph concepts to improve the quality of the received signals. Comparing the normalized results obtained by SDR with those obtained from a commercial vector network analyzer (VNA), we demonstrate that the results are sufficiently close, and the SDR-based experiments can provide satisfactory measurement of the in-situ sensors. The objective is to eventually employ this wireless measurement system for soil nutrient sensing.
Open AccessSoftware Defined Radio-Based Wireless Sensing System
In this paper, we investigate the application of using software-defined radio (SDR) and surface acoustic wave (SAW) device for wireless measurement of the response of in situ sensors. SDR uses software to realize different communication functions. After collecting the magnitude and phase of the response at discrete frequencies, we apply inverse Fourier transform to analyze the time domain responses which, in turn, allows for monitoring the changes of the response of the in situ sensor. We employ microwave signal flow graph concepts to improve the quality of the received signals. Comparing the normalized results obtained by SDR with those obtained from a commercial vector network analyzer (VNA), we demonstrate that the results are sufficiently close, and the SDR-based experiments can provide satisfactory measurement of the in-situ sensors. The objective is to eventually employ this wireless measurement system for soil nutrient sensing.
- 19 September 2013
- Published by Environmental Health Perspectives in ISEE Conference Abstracts
- Vol. 2013 (1)
Exposure of Nanoparticles in Indoor Air and on Interior Surfaces – A Study of Detection Techniques
Environmental Health Perspectives is an Open Access journal published by the National Institute of Environmental Health Sciences. Environmental Health Perspectives is an Open Access journal published by the National Institute of Environmental Health Sciences.
- 19 September 2013
- Published by Environmental Health Perspectives in ISEE Conference Abstracts
- Vol. 2013 (1)
Exposure of Nanoparticles in Indoor Air and on Interior Surfaces – A Study of Detection Techniques
Environmental Health Perspectives is an Open Access journal published by the National Institute of Environmental Health Sciences. Environmental Health Perspectives is an Open Access journal published by the National Institute of Environmental Health Sciences.
- 5 July 2005
- Published by Wiley in Chemie Ingenieur Technik
- Vol. 77 (7) , 867-873
Bildung von Goldnanopartikeln und Nanopartikelaggregaten in statischen Mikromischern in Gegenwart von Rinderserumalbumin (BSA)
- 5 July 2005
- Published by Wiley in Chemie Ingenieur Technik
- Vol. 77 (7) , 867-873
Bildung von Goldnanopartikeln und Nanopartikelaggregaten in statischen Mikromischern in Gegenwart von Rinderserumalbumin (BSA)