Maryam Habibollahi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Maryam Habibollahi has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Andreas Demosthenous
University College London
4 shared publications - Dai Jiang
University College London
4 shared publications - Henry Thomas Lancashire
University College London
3 shared publications - Noora Almarri
University College London,Department of Electronic and Electrical Engineering,London,UK,WC1E 7JE
3 shared publications - Yu Wu
Department of Electronic and Electrical Engineering, University College London, London, U.K.
2 shared publications Barney Bryson
Department of Neuromuscular Diseases, UCL Institute of Neurology, London, U.K.
1 shared publication
Latest Publications
- Open Access
- 17 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 18 (5) , 954-975
Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review
Interfaces with peripheral nerves have been widely developed to enable bioelectronic control of neural activity. Peripheral nerve neuromodulation shows great potential in addressing motor dysfunctions, neurological disorders, and psychiatric conditions. The integration of high-density neural electrodes with stimulation and recording circuits poses a challenge in the design of neural interfaces. Recent advances in active electrode strategies have achieved improved reliability and performance by implementing in-situ control, stimulation, and recording of neural fibers. This paper presents an overview of state-of-the-art neural interface systems that comprise a range of neural electrodes, neurostimulators, and bio-amplifier circuits, with a special focus on interfaces for the peripheral nerves. A discussion on the efficacy of active electrode systems and recommendations for future directions conclude this paper.
- 17 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 18 (5) , 954-975
Open AccessActive Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review
Interfaces with peripheral nerves have been widely developed to enable bioelectronic control of neural activity. Peripheral nerve neuromodulation shows great potential in addressing motor dysfunctions, neurological disorders, and psychiatric conditions. The integration of high-density neural electrodes with stimulation and recording circuits poses a challenge in the design of neural interfaces. Recent advances in active electrode strategies have achieved improved reliability and performance by implementing in-situ control, stimulation, and recording of neural fibers. This paper presents an overview of state-of-the-art neural interface systems that comprise a range of neural electrodes, neurostimulators, and bio-amplifier circuits, with a special focus on interfaces for the peripheral nerves. A discussion on the efficacy of active electrode systems and recommendations for future directions conclude this paper.
- Open Access
- 19 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
A High-Voltage, Implantable ASIC for Active Interfaces of the Vagus Nerve
Versatility of neural interfaces is a key factor in the efficacy of bioelectronic solutions for treating neurological and cardiac disorders. High-density and highly selective interfaces demand a small form factor, resulting in very high electrode impedances that require a large compliance voltage. This paper presents the design of a low-noise, electrode-driving ASIC in 180-nm high-voltage CMOS technology to achieve concurrent stimulation and recording for vagus nerve interfaces. Inter-channel crosstalk is minimized using pole-shifting. The ASIC has a variable recording gain of 60 to 74 dB and programmable, stimulating currents of 4 to 124 μA, which account for variations in the electrode characteristics. The ASIC occupies an area of 2.31 mm 2 . Measured results show clear biphasic stimulus pulses ranging in widths from 10 to 500 μs. To address the impact of artifacts on biopotential recording, the recording amplifier has a very low input-referred noise of 2.92 μVrms over a variable bandwidth that ranges from 300 Hz to 1.4 kHz or 6.6 kHz with or without pole shifting, respectively.
- 19 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Open AccessA High-Voltage, Implantable ASIC for Active Interfaces of the Vagus Nerve
Versatility of neural interfaces is a key factor in the efficacy of bioelectronic solutions for treating neurological and cardiac disorders. High-density and highly selective interfaces demand a small form factor, resulting in very high electrode impedances that require a large compliance voltage. This paper presents the design of a low-noise, electrode-driving ASIC in 180-nm high-voltage CMOS technology to achieve concurrent stimulation and recording for vagus nerve interfaces. Inter-channel crosstalk is minimized using pole-shifting. The ASIC has a variable recording gain of 60 to 74 dB and programmable, stimulating currents of 4 to 124 μA, which account for variations in the electrode characteristics. The ASIC occupies an area of 2.31 mm 2 . Measured results show clear biphasic stimulus pulses ranging in widths from 10 to 500 μs. To address the impact of artifacts on biopotential recording, the recording amplifier has a very low input-referred noise of 2.92 μVrms over a variable bandwidth that ranges from 300 Hz to 1.4 kHz or 6.6 kHz with or without pole shifting, respectively.
- 26 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 16 (5) , 752-765
A Fully Implantable Opto-Electro Closed-Loop Neural Interface for Motor Neuron Disease Studies
This paper presents a fully implantable closed-loop device for use in freely moving rodents to investigate new treatments for motor neuron disease. The 0.18 µm CMOS integrated circuit comprises 4 stimulators, each featuring 16 channels for optical and electrical stimulation using arbitrary current waveforms at frequencies from 1.5 Hz to 50 kHz, and a bandwidth programmable front-end for neural recording. The implant uses a Qi wireless inductive link which can deliver >100 mW power at a maximum distance of 2 cm for a freely moving rodent. A backup rechargeable battery can support 10 mA continuous stimulation currents for 2.5 hours in the absence of an inductive power link. The implant is controlled by a graphic user interface with broad programmable parameters via a Bluetooth low energy bidirectional data telemetry link. The encapsulated implant is 40 mm × 20 mm × 10 mm. Measured results are presented showing the electrical performance of the electronics and the packaging method.
- 26 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 16 (5) , 752-765
A Fully Implantable Opto-Electro Closed-Loop Neural Interface for Motor Neuron Disease Studies
This paper presents a fully implantable closed-loop device for use in freely moving rodents to investigate new treatments for motor neuron disease. The 0.18 µm CMOS integrated circuit comprises 4 stimulators, each featuring 16 channels for optical and electrical stimulation using arbitrary current waveforms at frequencies from 1.5 Hz to 50 kHz, and a bandwidth programmable front-end for neural recording. The implant uses a Qi wireless inductive link which can deliver >100 mW power at a maximum distance of 2 cm for a freely moving rodent. A backup rechargeable battery can support 10 mA continuous stimulation currents for 2.5 hours in the absence of an inductive power link. The implant is controlled by a graphic user interface with broad programmable parameters via a Bluetooth low energy bidirectional data telemetry link. The encapsulated implant is 40 mm × 20 mm × 10 mm. Measured results are presented showing the electrical performance of the electronics and the packaging method.
- 27 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 14 (5) , 997-1007
Time Stamp – A Novel Time-to-Digital Demodulation Method for Bioimpedance Implant Applications
Bioimpedance analysis is a non-invasive and inexpensive technology to investigate the electrical properties of biological tissues. The analysis requires demodulation to extract the real and imaginary parts of the impedance. Conventional systems use complex architectures such as I-Q demodulation. In this paper, a very simple alternative time-to-digital demodulation method or time stamp is proposed. It employs only three comparators to identify or stamp in the time domain, the crossing points of the excitation signal and the measured signal. In a CMOS proof of concept design, the accuracy of impedance magnitude and phase is 97.06% and 98.81% respectively over a bandwidth of 10 kHz to 500 kHz. The effect of fractional-N synthesis is analysed for the counter-based zero crossing phase detector obtaining a finer phase resolution (0.51 at 500 kHz) using a counter clock frequency (f_clk = 12.5 MHz). Because of its circuit simplicity and ease of transmitting the time stamps, the method is very suited to implantable devices requiring low area and power consumption.
- 27 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 14 (5) , 997-1007
Time Stamp – A Novel Time-to-Digital Demodulation Method for Bioimpedance Implant Applications
Bioimpedance analysis is a non-invasive and inexpensive technology to investigate the electrical properties of biological tissues. The analysis requires demodulation to extract the real and imaginary parts of the impedance. Conventional systems use complex architectures such as I-Q demodulation. In this paper, a very simple alternative time-to-digital demodulation method or time stamp is proposed. It employs only three comparators to identify or stamp in the time domain, the crossing points of the excitation signal and the measured signal. In a CMOS proof of concept design, the accuracy of impedance magnitude and phase is 97.06% and 98.81% respectively over a bandwidth of 10 kHz to 500 kHz. The effect of fractional-N synthesis is analysed for the counter-based zero crossing phase detector obtaining a finer phase resolution (0.51 at 500 kHz) using a counter clock frequency (f_clk = 12.5 MHz). Because of its circuit simplicity and ease of transmitting the time stamps, the method is very suited to implantable devices requiring low area and power consumption.