Tristan Sumner Grieve
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tristan Sumner Grieve has a total of 130 co-authors. Here are the top co-authors by number of shared publications:
- Joel A. Kulesza
Los Alamos National Laboratory
4 shared publications - Alexander Rich Clark
Los Alamos National Laboratory
3 shared publications - Colin James Josey
Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)
3 shared publications - I. Holmes
Commonwealth Fusion Systems 1 , Devens, Massachusetts 01434
3 shared publications - Jeffrey S. Bull
Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)
3 shared publications - Jerawan Chudoung Armstrong
Los Alamos National Laboratory
3 shared publications
Latest Publications
- 29 August 2025
- Published by Elsevier in Fusion Engineering and Design
- Vol. 221
An OpenMC model of the SPARC tokamak for the diagnostic scoping studies
- 29 August 2025
- Published by Elsevier in Fusion Engineering and Design
- Vol. 221
An OpenMC model of the SPARC tokamak for the diagnostic scoping studies
- Open Access
- 1 October 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (10)
Overview of the early campaign diagnostics for the SPARC tokamak (invited)
The SPARC tokamak is a high-field, Bt0 ∼12 T, medium-sized, R0 = 1.85 m, tokamak that is presently under construction in Devens, MA, led by Commonwealth Fusion Systems. It will be used to de-risk the high-field tokamak path to a fusion power plant and demonstrate the commercial viability of fusion energy. SPARC’s first campaign plan is to achieve Qfus > 1 using an ICRF-heated, 15 m from the center of the tokamak, on the other side of a 2.4 m concrete shielding wall. A series of 31 large-scale penetrations have been included in the SPARC Tokamak Hall to facilitate integration of early campaign diagnostics and to provide upgradability.
- 1 October 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (10)
Open AccessOverview of the early campaign diagnostics for the SPARC tokamak (invited)
The SPARC tokamak is a high-field, Bt0 ∼12 T, medium-sized, R0 = 1.85 m, tokamak that is presently under construction in Devens, MA, led by Commonwealth Fusion Systems. It will be used to de-risk the high-field tokamak path to a fusion power plant and demonstrate the commercial viability of fusion energy. SPARC’s first campaign plan is to achieve Qfus > 1 using an ICRF-heated, 15 m from the center of the tokamak, on the other side of a 2.4 m concrete shielding wall. A series of 31 large-scale penetrations have been included in the SPARC Tokamak Hall to facilitate integration of early campaign diagnostics and to provide upgradability.
- Open Access
- 1 August 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (8)
Neutronics simulations for the design of neutron flux monitors in SPARC
This paper presents the development and application of high-fidelity neutronic models of the SPARC tokamak for the design of neutron flux monitors (NFM) for application during plasma operations. NFMs measure the neutron flux in the tokamak hall, which is related to fusion power via calibration. We have explored Boron-10 gamma-compensated ionization chambers (ICs) and parallel-plate Uranium-238 fission chambers (FCs). We plan for all NFMs to be located by the wall in the tokamak hall and directly exposed to neutrons streaming through a shielded opening in a midplane port. Our simulations primarily use a constructive solid geometry-based OpenMC model based on the true SPARC geometry. The OpenMC model is benchmarked against a detailed CAD-based MCNP6 model. The B10 ICs are equipped with high-density polyethylene (HDPE) sleeves, borated HDPE housings, and borated aluminum covers to shield out scattered neutrons, optimize detector response levels, and make calibration robust against changes in the tokamak hall. The B10 neutron absorption branching ratio may cause the detectors’ responses to be non-linear to neutron flux >200 keV. However, our simulations unveil that, in the SPARC environment and with the proposed housings and sleeves, >99% of the detector responses are induced by <100 keV neutrons. U238’s insensitivity to slow neutrons makes this FC a promising candidate for direct fusion neutron measurements. Along with a borated HDPE sleeve, about 60% of the FCs’ responses are induced by direct neutrons.
- 1 August 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (8)
Open AccessNeutronics simulations for the design of neutron flux monitors in SPARC
This paper presents the development and application of high-fidelity neutronic models of the SPARC tokamak for the design of neutron flux monitors (NFM) for application during plasma operations. NFMs measure the neutron flux in the tokamak hall, which is related to fusion power via calibration. We have explored Boron-10 gamma-compensated ionization chambers (ICs) and parallel-plate Uranium-238 fission chambers (FCs). We plan for all NFMs to be located by the wall in the tokamak hall and directly exposed to neutrons streaming through a shielded opening in a midplane port. Our simulations primarily use a constructive solid geometry-based OpenMC model based on the true SPARC geometry. The OpenMC model is benchmarked against a detailed CAD-based MCNP6 model. The B10 ICs are equipped with high-density polyethylene (HDPE) sleeves, borated HDPE housings, and borated aluminum covers to shield out scattered neutrons, optimize detector response levels, and make calibration robust against changes in the tokamak hall. The B10 neutron absorption branching ratio may cause the detectors’ responses to be non-linear to neutron flux >200 keV. However, our simulations unveil that, in the SPARC environment and with the proposed housings and sleeves, >99% of the detector responses are induced by <100 keV neutrons. U238’s insensitivity to slow neutrons makes this FC a promising candidate for direct fusion neutron measurements. Along with a borated HDPE sleeve, about 60% of the FCs’ responses are induced by direct neutrons.
- Open Access
- 5 May 2023
- Published by Office of Scientific and Technical Information (OSTI)
Installing MCNP6.2 on Microsoft Windows
The U.S. Department of Energy's Office of Scientific and Technical Information
- 5 May 2023
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessInstalling MCNP6.2 on Microsoft Windows
The U.S. Department of Energy's Office of Scientific and Technical Information
- Open Access
- 10 January 2023
- Published by Office of Scientific and Technical Information (OSTI)
MCNP® Code V.6.3.0 Release Notes
The U.S. Department of Energy's Office of Scientific and Technical Information
- 10 January 2023
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessMCNP® Code V.6.3.0 Release Notes
The U.S. Department of Energy's Office of Scientific and Technical Information
- Open Access
- 29 September 2022
- Published by Office of Scientific and Technical Information (OSTI)
Inferring Water Content from Neutron Die-away Curves for Planetary Science Applications
The U.S. Department of Energy's Office of Scientific and Technical Information
- 29 September 2022
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessInferring Water Content from Neutron Die-away Curves for Planetary Science Applications
The U.S. Department of Energy's Office of Scientific and Technical Information
- 28 September 2022
- Published by Office of Scientific and Technical Information (OSTI)
MCNP® Code Version 6.3.0 Theory & User Manual
The U.S. Department of Energy's Office of Scientific and Technical Information
- 28 September 2022
- Published by Office of Scientific and Technical Information (OSTI)
MCNP® Code Version 6.3.0 Theory & User Manual
The U.S. Department of Energy's Office of Scientific and Technical Information
- 17 August 2022
- Published by Office of Scientific and Technical Information (OSTI)
Performance Analysis of the Expected Track Length Estimator
The U.S. Department of Energy's Office of Scientific and Technical Information
- 17 August 2022
- Published by Office of Scientific and Technical Information (OSTI)
Performance Analysis of the Expected Track Length Estimator
The U.S. Department of Energy's Office of Scientific and Technical Information
- 15 February 2022
- Published by Office of Scientific and Technical Information (OSTI)
FY21 MCNP® Updates for the Nuclear Criticality Safety Program [Slides]
LANL has devoted a substantial amount effort toward the MCNP6.3 release over the past year by improving many of their processes, infrastructure, and capabilities. Many new resources in support of the MCNP code and DOE NCSP applications are coming online now. LANL is excited to receive feedback on all of the new and improved capabilities that will be packaged with MCNP6.3.
- 15 February 2022
- Published by Office of Scientific and Technical Information (OSTI)
FY21 MCNP® Updates for the Nuclear Criticality Safety Program [Slides]
LANL has devoted a substantial amount effort toward the MCNP6.3 release over the past year by improving many of their processes, infrastructure, and capabilities. Many new resources in support of the MCNP code and DOE NCSP applications are coming online now. LANL is excited to receive feedback on all of the new and improved capabilities that will be packaged with MCNP6.3.