Zhengjian Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhengjian Wang has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Xichun Luo
Centre for Precision Manufacturing, DMEM, University of Strathclyde, Glasgow, UK
3 shared publications - Asimina Kazakidi
Department of Biomedical Engineering, University of Strathclyde, Glasgow, UK
1 shared publication Faxian Cao
Centre for Precision Manufacturing, DMEM, University of Strathclyde, Glasgow, G1 1XJ, UK
1 shared publicationGrant D. Stewart
Department of Surgery, University of Cambridge, Cambridge Biomedical Campus, Cambridge, UK
1 shared publication- Jian Gao
Centre for Precision Manufacturing, Department of Design, Manufacturing and Engineering Management, University of Strathclyde, Glasgow G1 1XJ, U.K.
1 shared publication - Jining Sun
Dalian University of Technology
1 shared publication
Latest Publications
- Open Access
- 4 July 2025
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 270, 108937
A numerical simulation study of soft tissue resection for low-damage precision cancer surgery
- 4 July 2025
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 270, 108937
Open AccessA numerical simulation study of soft tissue resection for low-damage precision cancer surgery
- Open Access
- 19 January 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (1) , 110
Investigation of Chip Morphology in Elliptical Vibration Micro-Turning of Silk Fibroin
Silk fibroin, known for its biocompatibility and biodegradability, holds significant promise for biomedical applications, particularly in drug delivery systems. The precise fabrication of silk fibroin particles, specifically those ranging from tens of nanometres to hundreds of microns, is critical for these uses. This study introduces elliptical vibration micro-turning as a method for producing silk fibroin particles in the form of cutting chips to serve as carriers for drug delivery systems. A hybrid finite element and smoothed particle hydrodynamics (FE-SPH) model was used to investigate how vibration parameters, such as frequency and amplitude, influence chip formation and morphology. This research is essential for determining the size and shape of silk fibroin particles, which are crucial for their effectiveness in drug delivery systems. The results demonstrate the superior capability of elliptical vibration micro-turning for producing shorter, spiral-shaped chips in the size range of tens of microns, in contrast to the long, continuous chips with zig-zag folds and segmented edges generated by conventional micro-turning. The unique zig-zag shapes result from the interplay between the high flexibility and hierarchical structure of silk fibroin and the controlled cutting environment provided by the diamond tool. Additionally, higher vibration frequencies and lower vertical amplitudes promote chip curling, facilitate breakage, and improve chip control, while reducing cutting forces. Experimental trials further validate the accuracy of the hybrid model. This study represents a significant advancement in the processing of silk fibroin film, offering a complementary approach to fabricating short, spiral-shaped silk fibroin particles with a high surface-area-to-volume ratio compared to traditional spheroids, which holds great potential for enhancing drug-loading efficiency in high-precision drug delivery systems.
- 19 January 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (1) , 110
Open AccessInvestigation of Chip Morphology in Elliptical Vibration Micro-Turning of Silk Fibroin
Silk fibroin, known for its biocompatibility and biodegradability, holds significant promise for biomedical applications, particularly in drug delivery systems. The precise fabrication of silk fibroin particles, specifically those ranging from tens of nanometres to hundreds of microns, is critical for these uses. This study introduces elliptical vibration micro-turning as a method for producing silk fibroin particles in the form of cutting chips to serve as carriers for drug delivery systems. A hybrid finite element and smoothed particle hydrodynamics (FE-SPH) model was used to investigate how vibration parameters, such as frequency and amplitude, influence chip formation and morphology. This research is essential for determining the size and shape of silk fibroin particles, which are crucial for their effectiveness in drug delivery systems. The results demonstrate the superior capability of elliptical vibration micro-turning for producing shorter, spiral-shaped chips in the size range of tens of microns, in contrast to the long, continuous chips with zig-zag folds and segmented edges generated by conventional micro-turning. The unique zig-zag shapes result from the interplay between the high flexibility and hierarchical structure of silk fibroin and the controlled cutting environment provided by the diamond tool. Additionally, higher vibration frequencies and lower vertical amplitudes promote chip curling, facilitate breakage, and improve chip control, while reducing cutting forces. Experimental trials further validate the accuracy of the hybrid model. This study represents a significant advancement in the processing of silk fibroin film, offering a complementary approach to fabricating short, spiral-shaped silk fibroin particles with a high surface-area-to-volume ratio compared to traditional spheroids, which holds great potential for enhancing drug-loading efficiency in high-precision drug delivery systems.
- Open Access
- 26 August 2022
- Published by Springer Nature in Nanomanufacturing and Metrology
- Vol. 5 (3) , 250-258
Insight into Atomic-Scale Adhesion at the C–Cu Interface During the Initial Stage of Nanoindentation
Adhesion is a common phenomenon in nanomachining which affects processing accuracy and repeatability. As material removal approaches the atomic or close-to-atomic scale, quantum mechanics becomes the dominant principle behind the atomic-level interaction. However, atomic-scale effects cannot be properly described by empirical potential function-based molecular dynamics simulations. This study uses a first-principles method to reveal the atomic-scale adhesion between a diamond tip and a copper slab during initial-stage nanoindentation. Using a simplified tip and slab model, adhesion energy, electronic distribution, and density of states are analyzed based on quantum chemistry calculation. Results show that atomic adhesion is primarily due to the covalent bonding interaction between C and Cu atoms, which can induce structural changes to the diamond tip and copper slab. The effects of tip position and angles on adhesion are further studied through a series of simulations. The results show that adhesion between the tip and slab is sensitive to the lattice structure and a variant in angstroms is enough to cause different adhesion and structural changes. The actual determinants of adhesion can only be the atomic and electronic structures at the tip–slab interface. Bond rotation and breakage are observed during simulation and their effects on adhesion are further discussed. To conclude, the first-principles method is important for the analysis of an atomic-scale interaction system, even if only as an aid to describing adhesion at atomic and electronic scales.
- 26 August 2022
- Published by Springer Nature in Nanomanufacturing and Metrology
- Vol. 5 (3) , 250-258
Open AccessInsight into Atomic-Scale Adhesion at the C–Cu Interface During the Initial Stage of Nanoindentation
Adhesion is a common phenomenon in nanomachining which affects processing accuracy and repeatability. As material removal approaches the atomic or close-to-atomic scale, quantum mechanics becomes the dominant principle behind the atomic-level interaction. However, atomic-scale effects cannot be properly described by empirical potential function-based molecular dynamics simulations. This study uses a first-principles method to reveal the atomic-scale adhesion between a diamond tip and a copper slab during initial-stage nanoindentation. Using a simplified tip and slab model, adhesion energy, electronic distribution, and density of states are analyzed based on quantum chemistry calculation. Results show that atomic adhesion is primarily due to the covalent bonding interaction between C and Cu atoms, which can induce structural changes to the diamond tip and copper slab. The effects of tip position and angles on adhesion are further studied through a series of simulations. The results show that adhesion between the tip and slab is sensitive to the lattice structure and a variant in angstroms is enough to cause different adhesion and structural changes. The actual determinants of adhesion can only be the atomic and electronic structures at the tip–slab interface. Bond rotation and breakage are observed during simulation and their effects on adhesion are further discussed. To conclude, the first-principles method is important for the analysis of an atomic-scale interaction system, even if only as an aid to describing adhesion at atomic and electronic scales.