Matthew J. Lohr
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Matthew J. Lohr has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Manuel K. Rausch
Department of Biomedical Engineering, The University of Texas at Austin, Austin, USA
4 shared publications - Adrian Buganza Tepole
School of Mechanical Engineering, Purdue University, West Lafayette, USA
1 shared publication - Alberto Madariaga
Department of Biomedical Engineering, The University of Texas at Austin
1 shared publication - Berkin Dortdivanlioglu
The University of Texas at Austin
1 shared publication - Chien-Yu Lin
Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX, USA
1 shared publication - Christian M. Jennings
Department of Biomedical Engineering, University of Texas at Austin, Austin, TX 78712
1 shared publication
Latest Publications
- Open Access
- 20 October 2026
- Published by Elsevier in SSRN Electronic Journal
The Impact of Embedding Matrices on Fiber Network Fracture Mechanics
In fibrous soft materials, fiber networks are embedded within a soft matrix. While the mechanics of these embedded fiber networks are vital to the function of these materials, the impact of the embedding matrix on fiber network mechanics remains poorly understood. This work addresses this gap by characterizing the macroscopic and microstructural effects of embedding matrices, fiber volume fraction, and network-matrix stiffness ratio. To this end, we utilized a mortar-type finite element framework to compare the energy release rates of embedded fiber networks, non-embedded fiber networks, and solitary matrices across seven stiffness ratios and up to nine fiber volume fractions. We found that softer matrices induce a greater increase in energy release rate, and that the optimal network-matrix stiffness ratio depends on the fiber volume fraction. Additionally, there is a maximum fiber volume fraction at which embedding increases the energy release rate. Beyond this fiber volume fraction value, the kinematic constraints imposed by the matrix cause the embedded fiber networks to have decreased energy release rate compared to their non-embedded counterparts. Finally, we identified that there is an optimal strain for a given fiber volume fraction at which embedding maximizes the energy release rate. Overall, this work ties microstructural kinematics to the macroscopic mechanics of embedded fiber networks and establishes a foundation for future experimental studies.
- 20 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessThe Impact of Embedding Matrices on Fiber Network Fracture Mechanics
In fibrous soft materials, fiber networks are embedded within a soft matrix. While the mechanics of these embedded fiber networks are vital to the function of these materials, the impact of the embedding matrix on fiber network mechanics remains poorly understood. This work addresses this gap by characterizing the macroscopic and microstructural effects of embedding matrices, fiber volume fraction, and network-matrix stiffness ratio. To this end, we utilized a mortar-type finite element framework to compare the energy release rates of embedded fiber networks, non-embedded fiber networks, and solitary matrices across seven stiffness ratios and up to nine fiber volume fractions. We found that softer matrices induce a greater increase in energy release rate, and that the optimal network-matrix stiffness ratio depends on the fiber volume fraction. Additionally, there is a maximum fiber volume fraction at which embedding increases the energy release rate. Beyond this fiber volume fraction value, the kinematic constraints imposed by the matrix cause the embedded fiber networks to have decreased energy release rate compared to their non-embedded counterparts. Finally, we identified that there is an optimal strain for a given fiber volume fraction at which embedding maximizes the energy release rate. Overall, this work ties microstructural kinematics to the macroscopic mechanics of embedded fiber networks and establishes a foundation for future experimental studies.
- Open Access
The Mechanical and Biological Evolution of Pressure Ulcer Formation and Healing in Mice
Pressure ulcers arise from sustained mechanical loading that impairs perfusion and damages skin tissues, yet the coupled mechanical and biological mechanisms of their formation and healing remain poorly characterized. We addressed this gap using a mouse model in which dorsal skin underwent 72 hours of magnet-induced ischemia followed by reperfusion, with tissue collected at 0, 3, 6, and 9 days and compared with baseline controls. From each mouse, we obtained paired samples from pressure ulcer and remote control (non-loaded) sites, mapped thickness by tissue profilometry, and performed equibiaxial testing with full-field digital image correlation and inverse finite element analysis to estimate regional material parameters. In parallel, we quantified CD31 + vasculature, F4/80 + macrophages, collagen content, and key cytokines. Pressure ulcer sites were compressed and thinner at Day 0, developed ulcers by Day 3, and continued to remodel through Day 9. Mechanical tests revealed heterogeneous strain fields with elevated deformation along ulcer borders, while remote control tissue deformed more homogeneously. These mechanical changes evolved alongside dynamic vessel and macrophage repopulation, increased collagen content at early time points, and cytokine upregulation within pressure ulcer tissue. Collectively, our data define the spatiotemporal co-evolution of tissue geometry, mechanics, collagen remodeling, and inflammation in pressure ulcers and provide a quantitative foundation for predictive mechanobiological models.
Open AccessThe Mechanical and Biological Evolution of Pressure Ulcer Formation and Healing in Mice
Pressure ulcers arise from sustained mechanical loading that impairs perfusion and damages skin tissues, yet the coupled mechanical and biological mechanisms of their formation and healing remain poorly characterized. We addressed this gap using a mouse model in which dorsal skin underwent 72 hours of magnet-induced ischemia followed by reperfusion, with tissue collected at 0, 3, 6, and 9 days and compared with baseline controls. From each mouse, we obtained paired samples from pressure ulcer and remote control (non-loaded) sites, mapped thickness by tissue profilometry, and performed equibiaxial testing with full-field digital image correlation and inverse finite element analysis to estimate regional material parameters. In parallel, we quantified CD31 + vasculature, F4/80 + macrophages, collagen content, and key cytokines. Pressure ulcer sites were compressed and thinner at Day 0, developed ulcers by Day 3, and continued to remodel through Day 9. Mechanical tests revealed heterogeneous strain fields with elevated deformation along ulcer borders, while remote control tissue deformed more homogeneously. These mechanical changes evolved alongside dynamic vessel and macrophage repopulation, increased collagen content at early time points, and cytokine upregulation within pressure ulcer tissue. Collectively, our data define the spatiotemporal co-evolution of tissue geometry, mechanics, collagen remodeling, and inflammation in pressure ulcers and provide a quantitative foundation for predictive mechanobiological models.
- Open Access
Loading causes molecular damage in fibrin fibers
Blood clotting is the body’s natural reaction in wound healing and is also the cause of many pathologies. Fibrin – the main protein in the clotting process provides clots’ mechanical strength by forming a scaffold of complex fibrin fibers. Fibrin fibers exhibit high extensibility and primarily elastic properties under static loading, which differ from in vivo dynamic forces. In many biological materials, the mechanical response changes under repeated loading/unloading (cyclic loading). Using lateral force microscopy, we show fibrin fibers possess viscoelastic behavior and experience irreversible damage under cyclic loading. Cross-linking results in a more rigid structure with permanent damage occurring mostly at larger strains, which is corroborated by computational modeling of fibrin extension using a hyperelastic model. Molecular spectroscopy analysis with broadband coherent anti-Stokes Raman scattering spectroscopy in addition to molecular dynamic simulations allow identification of the source of damage, the unfolding pattern, and inter and intramolecular changes in fibrin. The results show partial recovery of protein’s secondary and tertiary structures under load, providing deeper understanding of fibrin’s unique behavior in wound healing or pathologies like stroke and embolism.
Open AccessLoading causes molecular damage in fibrin fibers
Blood clotting is the body’s natural reaction in wound healing and is also the cause of many pathologies. Fibrin – the main protein in the clotting process provides clots’ mechanical strength by forming a scaffold of complex fibrin fibers. Fibrin fibers exhibit high extensibility and primarily elastic properties under static loading, which differ from in vivo dynamic forces. In many biological materials, the mechanical response changes under repeated loading/unloading (cyclic loading). Using lateral force microscopy, we show fibrin fibers possess viscoelastic behavior and experience irreversible damage under cyclic loading. Cross-linking results in a more rigid structure with permanent damage occurring mostly at larger strains, which is corroborated by computational modeling of fibrin extension using a hyperelastic model. Molecular spectroscopy analysis with broadband coherent anti-Stokes Raman scattering spectroscopy in addition to molecular dynamic simulations allow identification of the source of damage, the unfolding pattern, and inter and intramolecular changes in fibrin. The results show partial recovery of protein’s secondary and tertiary structures under load, providing deeper understanding of fibrin’s unique behavior in wound healing or pathologies like stroke and embolism.
- Open Access
- 29 August 2022
- Published by The Royal Society in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Vol. 380 (2234) , 20210365
An introduction to the Ogden model in biomechanics: benefits, implementation tools and limitations
Constitutive models are important to biomechanics for two key reasons. First, constitutive modelling is an essential component of characterizing tissues’ mechanical properties for informing theoretical and computational models of biomechanical systems. Second, constitutive models can be used as a theoretical framework for extracting and comparing key quantities of interest from material characterization experiments. Over the past five decades, the Ogden model has emerged as a popular constitutive model in soft tissue biomechanics with relevance to both informing theoretical and computational models and to comparing material characterization experiments. The goal of this short review is threefold. First, we will discuss the broad relevance of the Ogden model to soft tissue biomechanics and the general characteristics of soft tissues that are suitable for approximating with the Ogden model. Second, we will highlight exemplary uses of the Ogden model in brain tissue, blood clot and other tissues. Finally, we offer a tutorial on fitting the one-term Ogden model to pure shear experimental data via both an analytical approximation of homogeneous deformation and a finite-element model of the tissue domain. Overall, we anticipate that this short review will serve as a practical introduction to the use of the Ogden model in biomechanics. This article is part of the theme issue ‘The Ogden model of rubber mechanics: Fifty years of impact on nonlinear elasticity’.
- 29 August 2022
- Published by The Royal Society in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Vol. 380 (2234) , 20210365
Open AccessAn introduction to the Ogden model in biomechanics: benefits, implementation tools and limitations
Constitutive models are important to biomechanics for two key reasons. First, constitutive modelling is an essential component of characterizing tissues’ mechanical properties for informing theoretical and computational models of biomechanical systems. Second, constitutive models can be used as a theoretical framework for extracting and comparing key quantities of interest from material characterization experiments. Over the past five decades, the Ogden model has emerged as a popular constitutive model in soft tissue biomechanics with relevance to both informing theoretical and computational models and to comparing material characterization experiments. The goal of this short review is threefold. First, we will discuss the broad relevance of the Ogden model to soft tissue biomechanics and the general characteristics of soft tissues that are suitable for approximating with the Ogden model. Second, we will highlight exemplary uses of the Ogden model in brain tissue, blood clot and other tissues. Finally, we offer a tutorial on fitting the one-term Ogden model to pure shear experimental data via both an analytical approximation of homogeneous deformation and a finite-element model of the tissue domain. Overall, we anticipate that this short review will serve as a practical introduction to the use of the Ogden model in biomechanics. This article is part of the theme issue ‘The Ogden model of rubber mechanics: Fifty years of impact on nonlinear elasticity’.