MAMukul Anand

Mukul Anand

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mukul Anand has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Optimal frequency determination for wind–hydro hybrid unit using Telegrapher’s method for low-frequency transmission lines

    by Mukul Anand, Debashis Chatterjee, Swapan Kumar Goswami

    This study addresses the optimal load flow problem for low-frequency transmission lines connected to wind farms and Pumped Storage Hydropower (PSH). The losses in the LF-HVac system and the voltage stability index are highly reliant on the operating frequency. Hence, it is essential to integrate an Optimal Load Flow (OLF) method in order to ascertain the appropriate solutions for these systems. The load flow solutions in this system involve the utilization of the Newton–Raphson method in conjunction with STATCOM. A proposed approach to simplify mathematical calculations involves the development of a two-port equivalent model for transmission lines. This model is based on solutions derived from the Telegrapher’s method. The OLF method, which has been proposed, has undergone testing with various algorithms and has been successfully implemented in the IEEE 39-BUS system. The obtained results demonstrate that the LF method, when combined with the proposed metaheuristic algorithm, achieves optimal frequency for low-frequency HVac systems while simultaneously ensuring system stability.

  • Open Access

    Online analysis of MFC-fuzzy PI based LF-HVAC system

    by Mukul Anand, Swapan Kumar Goswami, Debashis Chatterjee

  • Modified jaya optimization and TOPSIS for determining the optimal frequency in LF-HVac

    by Mukul Anand, Swapan Kumar Goswami, Debashis Chatterjee, Anagha Bhattacharya, Jalil Piran


  • Open Access

    Loss Minimization and Voltage Stability With Optimum Frequency Determination of LF-HVac Lines Based on Wind-Hydro-Gas Turbine Unit

    by Mukul Anand, Debashis Chatterjee, Swapan Kumar Goswami, Anagha Bhattacharya, Hyun Han Kwon, Jalil Piran

    This study addresses the loss minimization and voltage stability analysis for low-frequency transmission lines connected to wind farms, pumped storage Hydropower (PSH) and Gas Turbine plant. The losses and the voltage stability index connected with renewable energy systems are heavily dependent on the operating frequency and create uncertainties in terms of voltage and frequency. Therefore, optimal frequency selection for LF-HVac lines also become important for the system. The voltage stability has been improved by STATCOM (Static Synchronous Compensator) for given system placed at different buses to maintain stability of system. A simplified two-port equivalent model for transmission lines based on solutions to Telegrapher’ method has been proposed for reducing system complexity and losses. The proposed method is tested with different existing algorithms and implemented in IEEE 39-Bus system and for scalability compared with IEEE 57-Bus system. The results obtained in MATLAB environment in Simulation lab which indicate that the proposed LF estimation method with the modified metaheuristic algorithm gives optimal frequency for low-frequency HVac systems.


  • Loss minimization based optimal frequency selection for low frequency transmission lines using telegrapher’s method

    by Mukul Anand, Debashis Chatterjee, Swapan Kumar Goswami

    The purpose of this study is to obtain the optimal frequency for low-frequency transmission lines while minimizing losses and maintaining the voltage stability of low-frequency systems. This study also emphasizes a reduction in calculations based on mathematical approaches. Telegrapher’s method has been used to reduce large calculations in low-frequency high-voltage alternating current (LF-HVac) lines. The static compensator (STATCOM) has been used to maintain voltage stability. For optimal frequency selection, a modified Jaya algorithm (MJAYA) for optimal load flow analysis was implemented. The MJAYA algorithm performed better than other conventional algorithms and determined the optimum frequency selection while minimizing losses. Voltage stability was also achieved with the proposed optimal load flow (OLF), and statistical analysis showed that the proposed OLF reduces the frequency deviation and standard error of the LF-HVac lines. The optimal frequency for LF-HVac lines has been achieved, Telegrapher’s method has been used in OLF, and STATCOM has been used in LF-HVac transmission lines.

  • State of Charge Analysis of Electric Vehicle Charging Stations using Renewable sources

    by Mukul Anand, Debashis Chatterjee, Swapan Kumar Goswami

    In this paper, Wind turbine (WT), Photovoltaic system (PV), Fuel Cell system (FC) and Hydel power system (HP) is utilized for Electric Vehicle charging stations (EVCS). With growing demand of electric vehicles, charging of EVCS became most important. The EVCS is designed to extract power and charge battery from different renewable source at different terrains. In difficult terrains, EVCS becomes ineffective to store charge for electric vehicles. So sources availability in particular terrain can increase the use of electric vehicles. However, State of charge (SOC) of battery is one of the challenging parameter for best performance of battery. SOC variation with power and voltage of renewable energy systems are calculated. Simulation based results is obtained with comparison analysis of SOC variation. The proposed analysis may be used to increase the EVCS system installation in difficult terrain areas and increase the demand of Electric vehicles.

  • A Reduced Switch Count Multilevel Inverter for PV Standalone System using Modified JAYA Algorithm

    by Rupali Mohanty, Debasish Chatterjee, Swati Suman, Mukul Anand

    This paper introduces a hybrid Multilevel Inverter with reduced switch count, which can generate higher output voltage level with minimum number of DC input sources. The operation of this proposed Multi Level Inverter (MLI) is carried out with unequal DC sources to achieve desired output voltage level. The reduced MLI output voltage is set to minimal Total Harmonic Distortion (THD) by the help of Modified JAYA algorithm. JAYA algorithm with improved steps by adopting an accelerating parameter has been proposed in this research work to obtain faster convergence of objective function. Modified JAYA algorithm has provided the suitable switching angles for the proposed three phase 15-level MLI and reduced the output voltage THD to 2.23%, which satisfies the standard set by IEEE-519. To prove the efficiency of this proposed modified algorithm, the comparative analysis is carried out through MATLAB program and Simulink tool using common JAYA and modified PSO algorithms. The performance and productivity of the proposed MLI has been investigated through simulation and experimental setup.


  • Multi-frequency control with fuzzy 2DOFPI in HVBTB converter of LF-HVAC system

    by Mukul Anand, Swapan Kumar Goswami, Debashis Chatterjee

    This paper illustrates the design of closed-loop controllers operating High Voltage Back to Back three-phase converter for frequency stabilization and power quality improvement. Simulations of the converter with Multi-frequency control with the proposed Fuzzy-2DOFPI (two degrees of freedom) are carried out in Simulink/MATLAB. Performance parameters such as frequency stabilization and source voltage total harmonic distortion (THD) are considered for comparison of the controllers with conventional ones. The fuzzy-tuned 2DOFPI controller with multi-frequency provides a better result, with a source-voltage THD of 0.23% and acts as a source-side filter for the converter. Finally, the fuzzy-tuned 2DOFPI with multi-frequency controller combination is implemented in an OPAL-RT 5650 real-time simulator for experimental validation of power quality enhancement and frequency stabilization.