Yiming Song
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yiming Song has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Hong Zhang
3 shared publications- Wang Zhang
Department of Architecture, Shanghai academy of fine arts, Shanghai University, Shanghai 200444, China
2 shared publications - Haisong Wang
Shanghai Academy of Fine Arts, Shanghai University, Shanghai 200040, China
1 shared publication Hongzhi Mo
Department of Architecture, Shanghai University, China
1 shared publication- Hongzhi Mo
Department of Architecture, Shanghai academy of fine arts, Shanghai University, Shanghai 200444, China
1 shared publication - Hongzhi Mo
Department of Architecture, Shanghai academy of fine arts, Shanghai University, Shanghai 200444, China
1 shared publication
Latest Publications
- 7 September 2026
- Published by Elsevier in Journal of Environmental Psychology
- Vol. 115
Restorative and cognitive effects of window views in university indoor settings: A scoping review
- 7 September 2026
- Published by Elsevier in Journal of Environmental Psychology
- Vol. 115
Restorative and cognitive effects of window views in university indoor settings: A scoping review
- Open Access
Decoding Spatial Vitality in Historic Districts: A Grey Relational Analysis of Multidimensional Built Environment Factors in Shanghai’s Zhangyuan
Enhancing the vitality of historic districts is a key challenge in China’s urban regeneration. This study takes Shanghai’s Zhangyuan Historic District as a case, constructing a framework with six spatial indicators—width-to-height ratio (W/H), interface transparency, connectivity, integration, Universal Thermal Climate Index (UTCI), and mean radiant temperature (MRT)—across spatial morphology, path accessibility, and thermal comfort. Using Grey Relational Analysis, the study quantitatively examines how these factors affect spatial vitality and pedestrian behavior. Findings indicate that, overall, W/H and connectivity are the primary drivers of vitality in plazas and alleys, while thermal comfort (MRT, UTCI) strongly affects stationary behaviors. By typology, plazas exhibit the strongest association with interface transparency (grey relational grade = 0.870), demonstrating that open sightlines and permeable interfaces promote pedestrian flow and staying. North–south alleys show pronounced associations with thermal comfort (MRT = 0.918; UTCI = 0.874), suggesting microclimate-friendly environments can substantially enhance vitality in linear walking spaces. East–west alleys are dominated by connectivity (0.831) and W/H (0.849), whereas integration shows a low grade (0.512), revealing weaker configurational coherence for this spatial type. At the micro-scale, connectivity outperforms integration in predicting pedestrian route choices, reflecting actual movement preferences. The study highlights the combined effects of multidimensional built environment factors and provides a scientific basis for targeted spatial optimization, sustainable renewal, and vitality-oriented design in historic urban areas.
Open AccessDecoding Spatial Vitality in Historic Districts: A Grey Relational Analysis of Multidimensional Built Environment Factors in Shanghai’s Zhangyuan
Enhancing the vitality of historic districts is a key challenge in China’s urban regeneration. This study takes Shanghai’s Zhangyuan Historic District as a case, constructing a framework with six spatial indicators—width-to-height ratio (W/H), interface transparency, connectivity, integration, Universal Thermal Climate Index (UTCI), and mean radiant temperature (MRT)—across spatial morphology, path accessibility, and thermal comfort. Using Grey Relational Analysis, the study quantitatively examines how these factors affect spatial vitality and pedestrian behavior. Findings indicate that, overall, W/H and connectivity are the primary drivers of vitality in plazas and alleys, while thermal comfort (MRT, UTCI) strongly affects stationary behaviors. By typology, plazas exhibit the strongest association with interface transparency (grey relational grade = 0.870), demonstrating that open sightlines and permeable interfaces promote pedestrian flow and staying. North–south alleys show pronounced associations with thermal comfort (MRT = 0.918; UTCI = 0.874), suggesting microclimate-friendly environments can substantially enhance vitality in linear walking spaces. East–west alleys are dominated by connectivity (0.831) and W/H (0.849), whereas integration shows a low grade (0.512), revealing weaker configurational coherence for this spatial type. At the micro-scale, connectivity outperforms integration in predicting pedestrian route choices, reflecting actual movement preferences. The study highlights the combined effects of multidimensional built environment factors and provides a scientific basis for targeted spatial optimization, sustainable renewal, and vitality-oriented design in historic urban areas.
- Open Access
Optimization Potential of Side-Lit Windows for Energy and Daylight Performance of University Classrooms in Shanghai
University classrooms have an urgent need for energy saving and environmental optimization due to the energy consumption characteristics and the demand for a daylight environment. Classrooms in hot summer and cold winter (HSCW) areas in China are typically designed with a south-facing layout, but the indoor environment of the classrooms in actual use is not as satisfactory as it should be. This research examines the impacts of side-lit window design parameters and shading forms on the energy and daylight performance by using measurements and simulation. It is found that there is significant seasonal variation in the energy consumption of teaching buildings in HSCW areas, with cooling energy consumption being the primary focus of energy conservation. Additionally, appropriate shading measures can not only compensate for the energy deficiencies of the orientation and window-to-wall ratio (WWR), but also considerably enhance the indoor daylight conditions. The results indicate that the most effective way to optimize energy and daylight performance in classrooms is to adopt a north-facing layout with 400 mm shading louvers. The illuminance level of the working plane can be made more uniform and the useful daylight illuminance (UDI) can be increased to over 60%. Therefore, classroom designs in HSCW areas can be more flexible in terms of optimizing energy efficiency and daylight conditions by integrating various design parameters and shading measures.
Open AccessOptimization Potential of Side-Lit Windows for Energy and Daylight Performance of University Classrooms in Shanghai
University classrooms have an urgent need for energy saving and environmental optimization due to the energy consumption characteristics and the demand for a daylight environment. Classrooms in hot summer and cold winter (HSCW) areas in China are typically designed with a south-facing layout, but the indoor environment of the classrooms in actual use is not as satisfactory as it should be. This research examines the impacts of side-lit window design parameters and shading forms on the energy and daylight performance by using measurements and simulation. It is found that there is significant seasonal variation in the energy consumption of teaching buildings in HSCW areas, with cooling energy consumption being the primary focus of energy conservation. Additionally, appropriate shading measures can not only compensate for the energy deficiencies of the orientation and window-to-wall ratio (WWR), but also considerably enhance the indoor daylight conditions. The results indicate that the most effective way to optimize energy and daylight performance in classrooms is to adopt a north-facing layout with 400 mm shading louvers. The illuminance level of the working plane can be made more uniform and the useful daylight illuminance (UDI) can be increased to over 60%. Therefore, classroom designs in HSCW areas can be more flexible in terms of optimizing energy efficiency and daylight conditions by integrating various design parameters and shading measures.
- Open Access
Design Parameters Affecting Energy Consumption of University Educational Buildings in Hot Summer and Cold Winter Area of China
The number of colleges and universities in China has been increasing year by year. University buildings have tremendous energy-saving potential due to their high personnel density and energy consumption demand. However, there is a lack of research and regulations focusing on such buildings and taking functional requirements, operating patterns, and climate conditions into account. In the HSCW zone of China, the overlap of energy consumption peak and universities’ winter and summer vacations will lead to improper or excessive implementation of energy-saving measures in practice. This research study on a university teaching building in Shanghai simulated the energy consumption with EnergyPlus (Version 22.1.0) to compare the variation trend of the building’s energy consumption (heating, cooling and annual energy consumption) under different design parameter settings. The influence of orientation and window–wall ratio on the energy consumption intensity of classrooms of various sizes was analyzed, and design strategies were proposed. The research indicates that the annual energy consumption of educational buildings in hot summer and cold winter areas can be reduced by approximately 44.4% during vacations. However, cooling energy consumption remains 18.0–19.4% greater than heating energy consumption. The energy intensity of classrooms decreases as the space size increases. Medium-sized classrooms, with an energy intensity ranging from 44.2–47.6 kWh/m2, require priority in energy-efficient design owing to their considerable quantity and high utilization. The findings offer design suggestions for the optimal orientation and window-to-wall ratios of classrooms of different scales, which can be used as a reference for the design of university teaching buildings and the energy-saving retrofit of existing campus buildings.
Open AccessDesign Parameters Affecting Energy Consumption of University Educational Buildings in Hot Summer and Cold Winter Area of China
The number of colleges and universities in China has been increasing year by year. University buildings have tremendous energy-saving potential due to their high personnel density and energy consumption demand. However, there is a lack of research and regulations focusing on such buildings and taking functional requirements, operating patterns, and climate conditions into account. In the HSCW zone of China, the overlap of energy consumption peak and universities’ winter and summer vacations will lead to improper or excessive implementation of energy-saving measures in practice. This research study on a university teaching building in Shanghai simulated the energy consumption with EnergyPlus (Version 22.1.0) to compare the variation trend of the building’s energy consumption (heating, cooling and annual energy consumption) under different design parameter settings. The influence of orientation and window–wall ratio on the energy consumption intensity of classrooms of various sizes was analyzed, and design strategies were proposed. The research indicates that the annual energy consumption of educational buildings in hot summer and cold winter areas can be reduced by approximately 44.4% during vacations. However, cooling energy consumption remains 18.0–19.4% greater than heating energy consumption. The energy intensity of classrooms decreases as the space size increases. Medium-sized classrooms, with an energy intensity ranging from 44.2–47.6 kWh/m2, require priority in energy-efficient design owing to their considerable quantity and high utilization. The findings offer design suggestions for the optimal orientation and window-to-wall ratios of classrooms of different scales, which can be used as a reference for the design of university teaching buildings and the energy-saving retrofit of existing campus buildings.
- 5 November 2022
- Published by Elsevier in Energy and Buildings
- Vol. 278
Research on influences of wall design on embodied and operating energy consumption: A case study of temporary building in China
- 5 November 2022
- Published by Elsevier in Energy and Buildings
- Vol. 278
Research on influences of wall design on embodied and operating energy consumption: A case study of temporary building in China
- Open Access
Parametric Design and Spatial Optimization of East–West-Oriented Teaching Spaces in Shanghai
The goal of the current study was to determine the appropriate spatial shapes for classroom occupants while saving energy. The research used parametric design and Genetic Algorithm (GA) to achieve this. Four recognized performance indicators, Energy Use Intensity (EUI), Useful Daylight Illuminance (UDI), Daylight Factor (DF), and Daylight Autonomy (DA), were used as the evaluation indexes for the research. The tests took place in six east–west-oriented classrooms at Shanghai University, China. The methodology was based on four steps: (1) parametric 3D modeling by Rhino and Grasshopper; (2) using building performance simulation tools; (3) running algorithm optimization; (4) outputting the useful results. The results proved that the methodology worked successfully in reducing energy consumption: optimized classrooms could be reduced by 7.5~14.5%, and classrooms with east directions were generally 4.8~8.3% more efficient than west-facing ones. The indoor lighting environment was also significantly improved, being slightly better than north–south-oriented classrooms in terms of the UDI index (60~75%) and inferior (but still high) in terms of the DF (4.0~7.0%) and DA (60~80%) indexes. The conclusion can help save design time in the early design process of teaching spaces.
Open AccessParametric Design and Spatial Optimization of East–West-Oriented Teaching Spaces in Shanghai
The goal of the current study was to determine the appropriate spatial shapes for classroom occupants while saving energy. The research used parametric design and Genetic Algorithm (GA) to achieve this. Four recognized performance indicators, Energy Use Intensity (EUI), Useful Daylight Illuminance (UDI), Daylight Factor (DF), and Daylight Autonomy (DA), were used as the evaluation indexes for the research. The tests took place in six east–west-oriented classrooms at Shanghai University, China. The methodology was based on four steps: (1) parametric 3D modeling by Rhino and Grasshopper; (2) using building performance simulation tools; (3) running algorithm optimization; (4) outputting the useful results. The results proved that the methodology worked successfully in reducing energy consumption: optimized classrooms could be reduced by 7.5~14.5%, and classrooms with east directions were generally 4.8~8.3% more efficient than west-facing ones. The indoor lighting environment was also significantly improved, being slightly better than north–south-oriented classrooms in terms of the UDI index (60~75%) and inferior (but still high) in terms of the DF (4.0~7.0%) and DA (60~80%) indexes. The conclusion can help save design time in the early design process of teaching spaces.
- Open Access
- 1 March 2021
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 696 (1) , 012023
A LCA-based Optimization Method of Green Ecological Building Envelopes: A Case Study in China
Climate change and resource depletion have led to the destruction of the environment, making it more urgent to address the irreversible environmental effects caused by construction industry. Life Cycle Assessment (LCA) is a systematic analytical method applied to evaluate buildings since 1990, covering every phase of buildings’ whole life cycle. However, the application and influence of LCA has been restricted due to the time-consuming procedures, the high cost of software, the hysteresis and limited samples in academic studies. This research takes a light-frame industrialized housing product as a prototype, collects a variety of common building envelope materials, evaluates the life cycle energy of 1344 possible wall assemblies by using C# language, and investigates the influences of different materials. The results show that construction energy accounts for 65.97% to 68.41% of life cycle energy, which is the largest part in the whole life span, much higher than the proportion of operation energy. Meanwhile, both life cycle energy and construction energy are strongly influenced by the outer layer materials of the building’s envelope, and the operation energy is closely related to the thermal insulation materials. In addition, this paper also shows a feasible methodology that could be adjusted to estimate various life cycle performance (including life cycle energy, life cycle carbon emissions, life cycle cost assessment, etc.) automatically in the architectural design stage and guide the buildings’ design more effectively.
- 1 March 2021
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 696 (1) , 012023
Open AccessA LCA-based Optimization Method of Green Ecological Building Envelopes: A Case Study in China
Climate change and resource depletion have led to the destruction of the environment, making it more urgent to address the irreversible environmental effects caused by construction industry. Life Cycle Assessment (LCA) is a systematic analytical method applied to evaluate buildings since 1990, covering every phase of buildings’ whole life cycle. However, the application and influence of LCA has been restricted due to the time-consuming procedures, the high cost of software, the hysteresis and limited samples in academic studies. This research takes a light-frame industrialized housing product as a prototype, collects a variety of common building envelope materials, evaluates the life cycle energy of 1344 possible wall assemblies by using C# language, and investigates the influences of different materials. The results show that construction energy accounts for 65.97% to 68.41% of life cycle energy, which is the largest part in the whole life span, much higher than the proportion of operation energy. Meanwhile, both life cycle energy and construction energy are strongly influenced by the outer layer materials of the building’s envelope, and the operation energy is closely related to the thermal insulation materials. In addition, this paper also shows a feasible methodology that could be adjusted to estimate various life cycle performance (including life cycle energy, life cycle carbon emissions, life cycle cost assessment, etc.) automatically in the architectural design stage and guide the buildings’ design more effectively.
- 1 September 2016
- Published by Elsevier in Energy and Buildings
- Vol. 128, 394-404
Life-time performance of post-disaster temporary housing: A case study in Nanjing
- 1 September 2016
- Published by Elsevier in Energy and Buildings
- Vol. 128, 394-404
Life-time performance of post-disaster temporary housing: A case study in Nanjing