Arpan A. Patel
Research Subjects
Arpan A. Patel has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
Alexander Spiessberger
Cleveland Clinic Foundation, Neurological Institute, Cleveland, OH, USA; Cleveland Clinic Foundation, Department of Neurosurgery, Cleveland, OH, USA
6 shared publicationsMichael P. Steinmetz
Department of Neurosurgery, Center for Spine Health, Cleveland Clinic Foundation, Cleveland Clinic Lerner College of Medicine, 9500 Euclid Avenue, Cleveland, OH 44195, USA
4 shared publicationsShaarada Srivatsa
Cleveland Clinic Foundation
4 shared publicationsGhaith Habboub
Cleveland Clinic Foundation
3 shared publicationsAjit Krishnaney
Cleveland Clinic Foundation
2 shared publicationsEdin Nevzati
Denver Health and Hospital Authority, Denver, CO, USA; Cantonal Hospital of Lucerne, Lucerne, Switzerland; University of Basel, Faculty of Medicine, Basel, Switzerland
2 shared publications
Latest Publications
- 23 September 2026
- Published by Wolters Kluwer Health in Clinical Spine Surgery
- Vol. 39 (9) , E439-E446
Instrumentation Strategies and New Technologies in Treating Cervical Spine Tumors
Study Design: Narrative review. Objective: This paper summarizes instrumentation strategies and emerging technologies for the treatment of cervical spine tumors. Summary of Background Data: The management of cervical spine tumors involves unique challenges due to inherent anatomic differences between the cervical spine compared with the remainder of the spine. Existing and emerging technologies, such as CT-based navigation, robotic-assisted surgery, ultrasound, and augmented reality, allow for increased efficiency and efficacy with instrumentation and surgical decompression. Methods: A thorough review of the cervical spine oncologic literature was performed using the PubMed database, and articles addressing the topic of instrumentation strategies and emerging technologies were included within the narrative review. Results: Cervical spine approaches in the oncologic patient involve a multidisciplinary approach, careful consideration of the patient’s systemic disease, and thorough anatomic and preoperative imaging review. Depending on the approach and extent of resection and expected structural instability, reconstruction methods vary from anterior-based, posterior-based, and circumferential. The unique considerations of the oncologic spine inform implant, graft, and reconstruction choice. Use of neuronavigation and, increasingly, robotic systems provides safe and beneficial adjuncts to the operative workflow. Future directions in cervical oncologic surgery include patient-specific implant design, artificial intelligence and machine-learning-based models, and augmented and mixed-reality systems to aid in intraoperative decision-making and navigation. Conclusions: Existing reconstruction and navigation technologies provide safe and accurate tools for cervical spine reconstruction after tumor resection. With improved systemic disease control, future surgical innovations may enhance intraoperative workflow, minimize imaging artifacts, and improve postoperative fusion in oncologic patients.
- 23 September 2026
- Published by Wolters Kluwer Health in Clinical Spine Surgery
- Vol. 39 (9) , E439-E446
Instrumentation Strategies and New Technologies in Treating Cervical Spine Tumors
Study Design: Narrative review. Objective: This paper summarizes instrumentation strategies and emerging technologies for the treatment of cervical spine tumors. Summary of Background Data: The management of cervical spine tumors involves unique challenges due to inherent anatomic differences between the cervical spine compared with the remainder of the spine. Existing and emerging technologies, such as CT-based navigation, robotic-assisted surgery, ultrasound, and augmented reality, allow for increased efficiency and efficacy with instrumentation and surgical decompression. Methods: A thorough review of the cervical spine oncologic literature was performed using the PubMed database, and articles addressing the topic of instrumentation strategies and emerging technologies were included within the narrative review. Results: Cervical spine approaches in the oncologic patient involve a multidisciplinary approach, careful consideration of the patient’s systemic disease, and thorough anatomic and preoperative imaging review. Depending on the approach and extent of resection and expected structural instability, reconstruction methods vary from anterior-based, posterior-based, and circumferential. The unique considerations of the oncologic spine inform implant, graft, and reconstruction choice. Use of neuronavigation and, increasingly, robotic systems provides safe and beneficial adjuncts to the operative workflow. Future directions in cervical oncologic surgery include patient-specific implant design, artificial intelligence and machine-learning-based models, and augmented and mixed-reality systems to aid in intraoperative decision-making and navigation. Conclusions: Existing reconstruction and navigation technologies provide safe and accurate tools for cervical spine reconstruction after tumor resection. With improved systemic disease control, future surgical innovations may enhance intraoperative workflow, minimize imaging artifacts, and improve postoperative fusion in oncologic patients.
- 14 February 2026
- Published by Taylor & Francis in Expert Review of Medical Devices
- Vol. 23 (4) , 393-400
Review and evolution of occipital fixation devices and techniques
Occipital-cervical (OC) fixation poses distinctive challenges due to unique craniocervical junction (CCJ) anatomy and a complex range of pathology leading to CCJ instability. There has been substantial evolution in modern OC fixation techniques since their introduction in the 1990s, each with implications on rate of fusion, range of motion, and ease of use. We performed a manual review of OC fixation techniques via a query of the National Library of Medicine MEDLINE database between September 10 and 1 October 2025. Categories of OC fixation included sublaminar wiring and bone graft, pre-integrated and modular plate-based constructs, non-plate-based screw-rod constructs, occipital condyle screws, and C1-occipital transarticular screws. Patient outcomes are comparable between modern plate-based and non-plate-based fixation systems, thus selection of technique is determined by surgeon preference, ease of use, and patient-specific anatomical considerations. Increasingly, modular plate-based and eyelet screw systems are gaining popularity due to their adaptability to varying anatomy, with poly-axial condylar and transarticular screws representing bail-out options in cases of suboccipital decompression or prior hardware failure due to the risk this technique poses to neurovascular structures. Future innovation may give rise to 3-D printed personalized implants for cases with complex anatomical or pathological considerations.
- 14 February 2026
- Published by Taylor & Francis in Expert Review of Medical Devices
- Vol. 23 (4) , 393-400
Review and evolution of occipital fixation devices and techniques
Occipital-cervical (OC) fixation poses distinctive challenges due to unique craniocervical junction (CCJ) anatomy and a complex range of pathology leading to CCJ instability. There has been substantial evolution in modern OC fixation techniques since their introduction in the 1990s, each with implications on rate of fusion, range of motion, and ease of use. We performed a manual review of OC fixation techniques via a query of the National Library of Medicine MEDLINE database between September 10 and 1 October 2025. Categories of OC fixation included sublaminar wiring and bone graft, pre-integrated and modular plate-based constructs, non-plate-based screw-rod constructs, occipital condyle screws, and C1-occipital transarticular screws. Patient outcomes are comparable between modern plate-based and non-plate-based fixation systems, thus selection of technique is determined by surgeon preference, ease of use, and patient-specific anatomical considerations. Increasingly, modular plate-based and eyelet screw systems are gaining popularity due to their adaptability to varying anatomy, with poly-axial condylar and transarticular screws representing bail-out options in cases of suboccipital decompression or prior hardware failure due to the risk this technique poses to neurovascular structures. Future innovation may give rise to 3-D printed personalized implants for cases with complex anatomical or pathological considerations.
- 22 November 2025
- Published by Elsevier in Clinical Biomechanics
- Vol. 131, 106712
A biomechanical study comparing combined S1AI and S3AI trajectories to other pelvic fixation techniques: A finite element analysis
- 22 November 2025
- Published by Elsevier in Clinical Biomechanics
- Vol. 131, 106712
A biomechanical study comparing combined S1AI and S3AI trajectories to other pelvic fixation techniques: A finite element analysis
- 31 March 2025
- Published by Wolters Kluwer Health in Clinical Spine Surgery
- Vol. 38 (5) , 230-237
Different Concepts in Short Segment Reconstruction of Moderate to Severe PI-LL Mismatch Deformity with ALIF, Mini-PSO, and TLIF
Sagittal plane deformities of the thoracolumbar spine, in which there is a significant mismatch between pelvic incidence (PI) and lumbar lordosis (LL) can negatively impact quality of life. Reconstructive surgery frequently involves long-segment spinal fusion. This video case series presents 3 patients with moderate to severe PI-LL mismatch spinal deformities, who underwent short construct corrections using varying strategies. Case 1 utilizes a combination of posterior column osteotomy (PCO) and anterior lumbar interbody fusion (ALIF) to achieve correction. Case 2 describes a combined transforaminal lumbar interbody fusion (TLIF) with a partial pedicle subtraction osteotomy (PSO). Lastly, case 3 details deformity correction with a multilevel TLIF, using extra-large footprint static banana cages, combined with posterior column osteotomy. The aim of this video case series is to outline these 3 techniques and illustrate that in select cases, a short-segment fusion limited to the lumbar spine can achieve significant deformity correction.
- 31 March 2025
- Published by Wolters Kluwer Health in Clinical Spine Surgery
- Vol. 38 (5) , 230-237
Different Concepts in Short Segment Reconstruction of Moderate to Severe PI-LL Mismatch Deformity with ALIF, Mini-PSO, and TLIF
Sagittal plane deformities of the thoracolumbar spine, in which there is a significant mismatch between pelvic incidence (PI) and lumbar lordosis (LL) can negatively impact quality of life. Reconstructive surgery frequently involves long-segment spinal fusion. This video case series presents 3 patients with moderate to severe PI-LL mismatch spinal deformities, who underwent short construct corrections using varying strategies. Case 1 utilizes a combination of posterior column osteotomy (PCO) and anterior lumbar interbody fusion (ALIF) to achieve correction. Case 2 describes a combined transforaminal lumbar interbody fusion (TLIF) with a partial pedicle subtraction osteotomy (PSO). Lastly, case 3 details deformity correction with a multilevel TLIF, using extra-large footprint static banana cages, combined with posterior column osteotomy. The aim of this video case series is to outline these 3 techniques and illustrate that in select cases, a short-segment fusion limited to the lumbar spine can achieve significant deformity correction.
- 15 October 2024
- Published by Elsevier in Neurosurgery Clinics of North America
- Vol. 36 (1) , 11-20
Posterior and Transforaminal Lumbar Interbody Fusion
- 15 October 2024
- Published by Elsevier in Neurosurgery Clinics of North America
- Vol. 36 (1) , 11-20
Posterior and Transforaminal Lumbar Interbody Fusion
- Open Access
- 22 August 2024
- Published by Elsevier in World Neurosurgery
- Vol. 191, 197
Surgical Technique for TDR/ACDF Hybrid Constructs: A Surgical Video Case Example
- 22 August 2024
- Published by Elsevier in World Neurosurgery
- Vol. 191, 197
Open AccessSurgical Technique for TDR/ACDF Hybrid Constructs: A Surgical Video Case Example
- 1 August 2024
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery: Spine
- Vol. 41 (2) , 159-166
C1–2 hypermobility and its impact on the spinal cord: a finite element analysis
OBJECTIVE: The authors present a finite element analysis (FEA) evaluating the mechanical impact of C1–2 hypermobility on the spinal cord. METHODS: The Code_Aster program was used to perform an FEA to determine the mechanical impact of C1–2 hypermobility on the spinal cord. Normative values of Young’s modulus were applied to the various components of the model, including bone, ligaments, and gray and white matter. Two models were created: 25° and 50° of C1-on-C2 rotation, and 2.5 and 5 mm of C1-on-C2 lateral translation. Maximum von Mises stress (VMS) throughout the cervicomedullary junction was calculated and analyzed. RESULTS: The FEA model of 2.5 mm lateral translation of C1 on C2 revealed maximum VMS for gray and white matter of 0.041 and 0.097 MPa, respectively. In the 5-mm translation model, the maximum VMS for gray and white matter was 0.069 and 0.162 MPa. The FEA model of 25° of C1-on-C2 rotation revealed maximum VMS for gray and white matter of 0.052 and 0.123 MPa. In the 50° rotation model, the maximum VMS for gray and white matter was 0.113 and 0.264 MPa. CONCLUSIONS: This FEA revealed significant spinal cord stress during pathological rotation (50°) and lateral translation (5 mm) consistent with values found during severe spinal cord compression and in patients with myelopathy. While this finite element model requires oversimplification of the atlantoaxial joint, the study provides biomechanical evidence that hypermobility within the C1–2 joint leads to pathological spinal cord stress.
- 1 August 2024
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery: Spine
- Vol. 41 (2) , 159-166
C1–2 hypermobility and its impact on the spinal cord: a finite element analysis
OBJECTIVE: The authors present a finite element analysis (FEA) evaluating the mechanical impact of C1–2 hypermobility on the spinal cord. METHODS: The Code_Aster program was used to perform an FEA to determine the mechanical impact of C1–2 hypermobility on the spinal cord. Normative values of Young’s modulus were applied to the various components of the model, including bone, ligaments, and gray and white matter. Two models were created: 25° and 50° of C1-on-C2 rotation, and 2.5 and 5 mm of C1-on-C2 lateral translation. Maximum von Mises stress (VMS) throughout the cervicomedullary junction was calculated and analyzed. RESULTS: The FEA model of 2.5 mm lateral translation of C1 on C2 revealed maximum VMS for gray and white matter of 0.041 and 0.097 MPa, respectively. In the 5-mm translation model, the maximum VMS for gray and white matter was 0.069 and 0.162 MPa. The FEA model of 25° of C1-on-C2 rotation revealed maximum VMS for gray and white matter of 0.052 and 0.123 MPa. In the 50° rotation model, the maximum VMS for gray and white matter was 0.113 and 0.264 MPa. CONCLUSIONS: This FEA revealed significant spinal cord stress during pathological rotation (50°) and lateral translation (5 mm) consistent with values found during severe spinal cord compression and in patients with myelopathy. While this finite element model requires oversimplification of the atlantoaxial joint, the study provides biomechanical evidence that hypermobility within the C1–2 joint leads to pathological spinal cord stress.
- Open Access
- 20 May 2024
- Published by SAGE Publications in Global Spine Journal
- Vol. 15 (3) , 1676-1684
Radiographic Alignment Parameters for Lumbosacral Reconstruction in Patients With Altered S1 Morphology
Study Design: Retrospective quantitative analysis study. Objectives: Pelvic incidence has been established as central radiographic marker which determines patient-specific correction goals during surgery for adult spinal deformity. In cases with sacral doming or sacral osteotomy where the PI cannot be calculated, reliable radiographic parameters need to be established to determine surgical goals. We aim to determine multiple radiographic parameters and formulas that can be utilized when the S1 superior endplate is obscured. Methods: Retrospective analysis was performed on 68 healthy volunteers without prior spine surgery with full-length radiographs. Pelvic incidence, sacral slope, and pelvic tilt were calculated for each patient. Additional measurements such as L4, L5, and S2 incidence, tilt, and slope were collected. A new radiographic parameter defined as the L4-Sciatic notch angle was measured. Regression analysis was performed on each value to determine its relationship with S1 based incidence, tilt, and slope. Results: Mean values for L5 incidence, L4 incidence, and L4 sciatic notch angle were 21.8° ± 8.9, 4.4° ± 8.1, and 44.4° ± 12, respectively. The linear regression analysis produced the following formulas which can be utilized to determine deformity correction goals when pelvic incidence can be calculated pre-operatively: L5i = .65*S1i–11.4, L4i = .44*S1i-18.6, and L4SNA = −.34*S1i + 66.5. In settings where pelvic incidence cannot be calculated, the following formulas can be utilized: L5i = .66*S2i-32.3 and L4SNA = −.02*S2i 2 + 1.1*S2i + 63.5. P -values for all regression analyses were <.001. Conclusion: This study provides target radiographic alignment values that can be utilized for patients with either pre-operative altered S1 endplates or in cases with intraoperative alteration of S1 (sacral osteotomy).
- 20 May 2024
- Published by SAGE Publications in Global Spine Journal
- Vol. 15 (3) , 1676-1684
Open AccessRadiographic Alignment Parameters for Lumbosacral Reconstruction in Patients With Altered S1 Morphology
Study Design: Retrospective quantitative analysis study. Objectives: Pelvic incidence has been established as central radiographic marker which determines patient-specific correction goals during surgery for adult spinal deformity. In cases with sacral doming or sacral osteotomy where the PI cannot be calculated, reliable radiographic parameters need to be established to determine surgical goals. We aim to determine multiple radiographic parameters and formulas that can be utilized when the S1 superior endplate is obscured. Methods: Retrospective analysis was performed on 68 healthy volunteers without prior spine surgery with full-length radiographs. Pelvic incidence, sacral slope, and pelvic tilt were calculated for each patient. Additional measurements such as L4, L5, and S2 incidence, tilt, and slope were collected. A new radiographic parameter defined as the L4-Sciatic notch angle was measured. Regression analysis was performed on each value to determine its relationship with S1 based incidence, tilt, and slope. Results: Mean values for L5 incidence, L4 incidence, and L4 sciatic notch angle were 21.8° ± 8.9, 4.4° ± 8.1, and 44.4° ± 12, respectively. The linear regression analysis produced the following formulas which can be utilized to determine deformity correction goals when pelvic incidence can be calculated pre-operatively: L5i = .65*S1i–11.4, L4i = .44*S1i-18.6, and L4SNA = −.34*S1i + 66.5. In settings where pelvic incidence cannot be calculated, the following formulas can be utilized: L5i = .66*S2i-32.3 and L4SNA = −.02*S2i 2 + 1.1*S2i + 63.5. P -values for all regression analyses were <.001. Conclusion: This study provides target radiographic alignment values that can be utilized for patients with either pre-operative altered S1 endplates or in cases with intraoperative alteration of S1 (sacral osteotomy).
- Open Access
- 29 April 2024
- Published by Elsevier in World Neurosurgery
- Vol. 187, e707-e713
The Use of Cranial Aneurysm Clips for Repair of Incidental Lumbar Durotomy: Operative Technique and Case Series
- 29 April 2024
- Published by Elsevier in World Neurosurgery
- Vol. 187, e707-e713
Open AccessThe Use of Cranial Aneurysm Clips for Repair of Incidental Lumbar Durotomy: Operative Technique and Case Series
- 1 April 2024
- Published by Taylor & Francis in Expert Review of Medical Devices
- Vol. 21 (5) , 381-390
Review of mechanisms of expandable spine surgery devices
1. Expandable devices such as interbody cages, vertebral body reconstruction cages, and intravertebral body expansion devices are frequently utilized in spine surgery to restore lordosis as well as...
- 1 April 2024
- Published by Taylor & Francis in Expert Review of Medical Devices
- Vol. 21 (5) , 381-390
Review of mechanisms of expandable spine surgery devices
1. Expandable devices such as interbody cages, vertebral body reconstruction cages, and intravertebral body expansion devices are frequently utilized in spine surgery to restore lordosis as well as...