Ali Altan Ertan Boz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ali Altan Ertan Boz has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
Erkan Çelik
Sakarya University Training and Research Hospital, Department of Ophthalmology, Sakarya, Turkey
4 shared publicationsMahmut Atum
Sakarya University Training and Research Hospital, Department of Ophthalmology, Sakarya, Turkey
4 shared publications- Ahmet Kaderli
Ophthalmology Department, Mugla Sitki Kocman University, Muğla, Turkey
2 shared publications Nilgün Özkan Aksoy
Sakarya University Training and Research Hospital, Department of Ophthalmology, Sakarya, Turkey
2 shared publicationsSedat Özmen
Sakarya University Training and Research Hospital, Department of Ophthalmology, Sakarya, Turkey
2 shared publicationsİsa Yuvacı
Sakarya University Training and Research Hospital, Department of Ophthalmology, Sakarya, Turkey
2 shared publications
Latest Publications
- 4 November 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
Formula Discordance and Refractive Target Error: Temporal Validation of Legacy–Modern Intraocular Lens Formula Disagreement as a Quality-Control Marker
Purpose: To determine whether disagreement between third-generation and modern intraocular lens (IOL) formulas identifies eyes at increased risk of refractive target error. Setting: Yenikent State Hospital, Sakarya, Türkiye. Design: Retrospective cohort with chronological derivation and temporal validation. Methods: Six hundred eyes with foldable one-piece IOL implantation were analyzed. Third-generation formulas were SRK/T, Hoffer Q, and Holladay 1; modern formulas were Barrett Universal II, Kane, EVO 2.0, PEARL-DGS, and Cooke K6. Formula-specific offsets were estimated in 400 earlier eyes and frozen for 200 later validation eyes. The Legacy–Modern Gap (LMG) was the absolute difference between mean predicted postoperative spherical equivalent of the 2 formula groups. The primary endpoint was an absolute target miss of at least 0.50 D. Results: Target miss occurred in 29.0% of derivation eyes and 26.0% of validation eyes. Validation mean absolute error was 0.284-0.317 D for modern formulas and 0.358-0.424 D for third-generation formulas (P<0.001). Each 0.10 D increase in LMG was associated with target error (adjusted odds ratio, 1.21; 95% CI, 1.05-1.38; P=0.007). Validation AUC was 0.650 versus 0.603 for biometrics alone (ΔAUC, 0.047; 95% CI, -0.015 to 0.111). Brier score improved by 0.0116 (95% CI, 0.0034-0.0200); calibration intercept was 0.01 and slope 1.25. Conclusions: Formula disagreement added information beyond biometrics but had modest discrimination. LMG is a supplementary quality-control signal rather than an independent rule for IOL selection.
- 4 November 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
Formula Discordance and Refractive Target Error: Temporal Validation of Legacy–Modern Intraocular Lens Formula Disagreement as a Quality-Control Marker
Purpose: To determine whether disagreement between third-generation and modern intraocular lens (IOL) formulas identifies eyes at increased risk of refractive target error. Setting: Yenikent State Hospital, Sakarya, Türkiye. Design: Retrospective cohort with chronological derivation and temporal validation. Methods: Six hundred eyes with foldable one-piece IOL implantation were analyzed. Third-generation formulas were SRK/T, Hoffer Q, and Holladay 1; modern formulas were Barrett Universal II, Kane, EVO 2.0, PEARL-DGS, and Cooke K6. Formula-specific offsets were estimated in 400 earlier eyes and frozen for 200 later validation eyes. The Legacy–Modern Gap (LMG) was the absolute difference between mean predicted postoperative spherical equivalent of the 2 formula groups. The primary endpoint was an absolute target miss of at least 0.50 D. Results: Target miss occurred in 29.0% of derivation eyes and 26.0% of validation eyes. Validation mean absolute error was 0.284-0.317 D for modern formulas and 0.358-0.424 D for third-generation formulas (P<0.001). Each 0.10 D increase in LMG was associated with target error (adjusted odds ratio, 1.21; 95% CI, 1.05-1.38; P=0.007). Validation AUC was 0.650 versus 0.603 for biometrics alone (ΔAUC, 0.047; 95% CI, -0.015 to 0.111). Brier score improved by 0.0116 (95% CI, 0.0034-0.0200); calibration intercept was 0.01 and slope 1.25. Conclusions: Formula disagreement added information beyond biometrics but had modest discrimination. LMG is a supplementary quality-control signal rather than an independent rule for IOL selection.
- Open Access
- 24 September 2026
- Published by Springer Nature in Cureus
- Vol. 18 (9) , e116840
Delayed Reconstruction of Post-traumatic Enophthalmos and Orbitomaxillary Deformity 25 Years After a Childhood Dog-Bite Injury: A Case Report
Dog-bite injuries in children usually involve facial soft tissues, while associated craniofacial fractures are uncommon and may be overlooked during the acute phase. A 35-year-old woman presented with long-standing right periocular asymmetry, infraorbital hollowing, anterior maxillary depression, and a medial lower eyelid notch 25 years after a childhood dog-bite injury. Best-corrected visual acuity was 20/20 in both eyes, ocular motility was normal, and diplopia was absent. Hertel exophthalmometry measured 18 mm on the right and 22 mm on the left. Computed tomography demonstrated chronic deformity of the right inferior orbital wall and anterior maxilla. Through a transconjunctival lower orbital approach extended to the anterior maxillary wall, the deformed anterior maxilla was divided vertically into three segments, reconstructed with block allograft bone, and stabilized with titanium plates and screws. The orbital floor was reconstructed with contoured titanium mesh, and the lower eyelid notch was treated by wedge resection and primary repair. At one month, periocular symmetry and midfacial projection had improved; Hertel measurements were 22 mm bilaterally, and postoperative imaging confirmed the position of the orbital mesh and maxillary fixation. This case illustrates the need to evaluate orbital support, midfacial projection, and eyelid contour together when treating chronic combined orbitomaxillary deformity after childhood facial trauma.
- 24 September 2026
- Published by Springer Nature in Cureus
- Vol. 18 (9) , e116840
Open AccessDelayed Reconstruction of Post-traumatic Enophthalmos and Orbitomaxillary Deformity 25 Years After a Childhood Dog-Bite Injury: A Case Report
Dog-bite injuries in children usually involve facial soft tissues, while associated craniofacial fractures are uncommon and may be overlooked during the acute phase. A 35-year-old woman presented with long-standing right periocular asymmetry, infraorbital hollowing, anterior maxillary depression, and a medial lower eyelid notch 25 years after a childhood dog-bite injury. Best-corrected visual acuity was 20/20 in both eyes, ocular motility was normal, and diplopia was absent. Hertel exophthalmometry measured 18 mm on the right and 22 mm on the left. Computed tomography demonstrated chronic deformity of the right inferior orbital wall and anterior maxilla. Through a transconjunctival lower orbital approach extended to the anterior maxillary wall, the deformed anterior maxilla was divided vertically into three segments, reconstructed with block allograft bone, and stabilized with titanium plates and screws. The orbital floor was reconstructed with contoured titanium mesh, and the lower eyelid notch was treated by wedge resection and primary repair. At one month, periocular symmetry and midfacial projection had improved; Hertel measurements were 22 mm bilaterally, and postoperative imaging confirmed the position of the orbital mesh and maxillary fixation. This case illustrates the need to evaluate orbital support, midfacial projection, and eyelid contour together when treating chronic combined orbitomaxillary deformity after childhood facial trauma.
- Open Access
- 8 July 2026
- Published by Springer Nature in BMC Ophthalmology
- Vol. 26 (1) , 392
Expanding visual horizons: comparative outcomes of bilateral implantation of an extended depth-of-focus versus enhanced and standard monofocal intraocular lenses
Patients undergoing cataract surgery have different postoperative visual priorities. Some primarily seek excellent uncorrected distance vision and accept t
- 8 July 2026
- Published by Springer Nature in BMC Ophthalmology
- Vol. 26 (1) , 392
Open AccessExpanding visual horizons: comparative outcomes of bilateral implantation of an extended depth-of-focus versus enhanced and standard monofocal intraocular lenses
Patients undergoing cataract surgery have different postoperative visual priorities. Some primarily seek excellent uncorrected distance vision and accept t
- 8 November 2024
- Published by Academician Publishing
- p. 71-92
Orbita Taban Kırıkları ve Cerrahi Tedavisinde Kullanılan İmplantlar
Orbita taban kırıkları en sık görülen orbita duvar kırığıdır. Tanısında maxillo-fasyal bilgisayarlı tomografi görüntülemesi altın standarttır. Cerrahi endikasyonlar ve müdahale zamanı hastanın başlangıçtaki klinik durumuna bağlıdır. Genellikle, ilk 7-10 gün ödem, kanama ve diplopinin geçmesi açısından hastalar gözlenmelidir. Persistan diplopi, enoftalmus, ekstraoküler hareket kısıtlılığı ve okülokardiyak refleks varlığı genellikle cerrahi onarım gerekliliğini belirleyen ana faktörlerdir. Cerrahi teknikte genellikle güvenli olan transkonjonktival yaklaşım tercih edilir. İdeal rekonstrüksiyon materyali konusunda literatürde hala bir konsensus bulunmamaktadır. İmplant seçiminde en iyi sonuç alınabilen ve en düşük komplikasyon oranına sahip implantlar seçilmelidir. İdeal materyal rezorbabl, osteokondüktif, enfeksiyona dirençli, minimum derecede reaksiyon gösteren, kemik büyümesine izin veren, ucuz ve kolayca bulunabilir olmalıdır. İmplantların bilgisayar destekli 3 boyutlu baskı tekniği ile üretilmesi orbital taban kırıkları onarımında kişiye ve kırığa özel implantların geliştirilmesine ve komplikasyonların azalmasına yardımcı olacaktır. Orbital floor fractures are the most common type of orbital wall fracture. Maxillofacial computed tomography imaging is considered the gold standard for diagnosis. Surgical indications and timing of intervention depend on the patient's initial clinical presentation. Typically, patients should be observed for the first 7–10 days to allow for the resolution of edema, hemorrhage, and diplopia. Persistent diplopia, enophthalmos, restricted extraocular movements, and the presence of an oculocardiac reflex are the primary factors that generally necessitate surgical repair. The transconjunctival approach, which is considered generally safe, is preferred in most surgical techniques. There remains no consensus in the literature regarding the ideal reconstruction material. The selection of implants should prioritize those that yield the best outcomes with the lowest complication rates. The ideal material should be resorbable, osteoconductive, resistant to infection, minimally reactive, promote bone growth, and be cost-effective and readily available. The use of computer-assisted 3D printing techniques in implant production can aid in the development of patient- and fracture-specific implants for orbital floor fracture repair, thereby reducing complications.
- 8 November 2024
- Published by Academician Publishing
- p. 71-92
Orbita Taban Kırıkları ve Cerrahi Tedavisinde Kullanılan İmplantlar
Orbita taban kırıkları en sık görülen orbita duvar kırığıdır. Tanısında maxillo-fasyal bilgisayarlı tomografi görüntülemesi altın standarttır. Cerrahi endikasyonlar ve müdahale zamanı hastanın başlangıçtaki klinik durumuna bağlıdır. Genellikle, ilk 7-10 gün ödem, kanama ve diplopinin geçmesi açısından hastalar gözlenmelidir. Persistan diplopi, enoftalmus, ekstraoküler hareket kısıtlılığı ve okülokardiyak refleks varlığı genellikle cerrahi onarım gerekliliğini belirleyen ana faktörlerdir. Cerrahi teknikte genellikle güvenli olan transkonjonktival yaklaşım tercih edilir. İdeal rekonstrüksiyon materyali konusunda literatürde hala bir konsensus bulunmamaktadır. İmplant seçiminde en iyi sonuç alınabilen ve en düşük komplikasyon oranına sahip implantlar seçilmelidir. İdeal materyal rezorbabl, osteokondüktif, enfeksiyona dirençli, minimum derecede reaksiyon gösteren, kemik büyümesine izin veren, ucuz ve kolayca bulunabilir olmalıdır. İmplantların bilgisayar destekli 3 boyutlu baskı tekniği ile üretilmesi orbital taban kırıkları onarımında kişiye ve kırığa özel implantların geliştirilmesine ve komplikasyonların azalmasına yardımcı olacaktır. Orbital floor fractures are the most common type of orbital wall fracture. Maxillofacial computed tomography imaging is considered the gold standard for diagnosis. Surgical indications and timing of intervention depend on the patient's initial clinical presentation. Typically, patients should be observed for the first 7–10 days to allow for the resolution of edema, hemorrhage, and diplopia. Persistent diplopia, enophthalmos, restricted extraocular movements, and the presence of an oculocardiac reflex are the primary factors that generally necessitate surgical repair. The transconjunctival approach, which is considered generally safe, is preferred in most surgical techniques. There remains no consensus in the literature regarding the ideal reconstruction material. The selection of implants should prioritize those that yield the best outcomes with the lowest complication rates. The ideal material should be resorbable, osteoconductive, resistant to infection, minimally reactive, promote bone growth, and be cost-effective and readily available. The use of computer-assisted 3D printing techniques in implant production can aid in the development of patient- and fracture-specific implants for orbital floor fracture repair, thereby reducing complications.
- Open Access
- 8 November 2024
- Published by Academician Publishing
Göz Hastalıklarında Güncel Çalışmalar VI
Glokom Tanısında Patern Elektroretinografi, Farnsworth-Munsell 100 Hue Renk Testi ve Heıdelberg Retina Tomografisi II İle Cup/Disk Oranı Sonuçlarının Normal Bireylerle ve Birbirleriyle İlişkisinin Karşılaştırılması Berrin UZUNOVALI Ertuğrul MİRZA Prematür Retinopatisinde Güncel Yaklaşım Aylin KARALEZLI Ahmet KADERLI Yaşa Bağlı Maküler Dejenerasyonda Gözlenen Geografik Atrofiye Yönelik Güncel Tedaviler Aylin KARALEZLI Sema KADERLI Glokomun Medikal Tedavisinde Yenilikler Ahmet KADERLI Umay GÜVENÇ Glokom ve Miyopi Başak MEMIŞ Ahmet KADERLI Orbita Taban Kırıkları ve Cerrahi Tedavisinde Kullanılan İmplantlar Ali Altan Ertan BOZ Kuru Göz Hastalığı Tanı ve Tedavisi Başak MEMIŞ Hüseyin Cem ŞİMŞEK Retina Ven Tıkanıklıkları Tedavisinde İntravitreal Deksametazon İmplant Sonuçları Serdar BİLİCİ Figen ŞERMET Pterjium Şerife Gülhan KONUK Pediatrik Hastalarda Ambliyopi Merve ŞİMŞEK Pediatrik Hastalarda Non-Paralitik Horizontal Şaşılıklar Merve ŞİMŞEK Yapay Zekanın Oftalmolojide Kullanımı Özgür EROĞUL Murat KAŞIKCI
- 8 November 2024
- Published by Academician Publishing
Open AccessGöz Hastalıklarında Güncel Çalışmalar VI
Glokom Tanısında Patern Elektroretinografi, Farnsworth-Munsell 100 Hue Renk Testi ve Heıdelberg Retina Tomografisi II İle Cup/Disk Oranı Sonuçlarının Normal Bireylerle ve Birbirleriyle İlişkisinin Karşılaştırılması Berrin UZUNOVALI Ertuğrul MİRZA Prematür Retinopatisinde Güncel Yaklaşım Aylin KARALEZLI Ahmet KADERLI Yaşa Bağlı Maküler Dejenerasyonda Gözlenen Geografik Atrofiye Yönelik Güncel Tedaviler Aylin KARALEZLI Sema KADERLI Glokomun Medikal Tedavisinde Yenilikler Ahmet KADERLI Umay GÜVENÇ Glokom ve Miyopi Başak MEMIŞ Ahmet KADERLI Orbita Taban Kırıkları ve Cerrahi Tedavisinde Kullanılan İmplantlar Ali Altan Ertan BOZ Kuru Göz Hastalığı Tanı ve Tedavisi Başak MEMIŞ Hüseyin Cem ŞİMŞEK Retina Ven Tıkanıklıkları Tedavisinde İntravitreal Deksametazon İmplant Sonuçları Serdar BİLİCİ Figen ŞERMET Pterjium Şerife Gülhan KONUK Pediatrik Hastalarda Ambliyopi Merve ŞİMŞEK Pediatrik Hastalarda Non-Paralitik Horizontal Şaşılıklar Merve ŞİMŞEK Yapay Zekanın Oftalmolojide Kullanımı Özgür EROĞUL Murat KAŞIKCI
- 21 September 2024
- Published by Sakarya Tip Dergisi in Sakarya Medical Journal
The Efficacy of Prismatic Bifocal Spectacle Lenses in Controlling Myopia Progression in Children.
Objective: Progression of myopia can lead to vision impairment and increase the risk of sight-threatening complications. Various strategies were described to control the progression of myopia, including the use of specialized spectacle. This retrospective study aimed to analyze the efficacy of prismatic bifocal spectacle lenses in controlling the progression of myopia in pediatric patients. Materials and Methods: Fifty-two eyes of 26 patients using prismatic bifocal spectacle lenses were retrospectively analyzed. Both eyes of each patient with a cycloplegic objective refraction measurement of ≥-2.00 D were included. Demographic data of the patients such as age and gender were investigated. The increase in objective spherical equivalent and axial length over the one year of single-vision spectacle use was compared with the increase observed one year after the prescription of bifocal prismatic spectacle. Results: The mean age of the patients was 11.65 ± 2.70 years. Sixteen patients were male, and 10 patients were female. The increase in mean spherical equivalent in eyes using single vision spectacles over one year was 1.25 ± 0.76 D, compared to 0.24 ± 0.14 D with prismatic bifocal spectacles, which was statistically significant). Similarly, the increase in mean axial length was 0.66 ± 0.31 mm with single vision spectacles and 0.014 ± 0.015 mm with bifocal spectacle, also statistically significant Multiple linear regression analysis revealed that baseline higher myopia and baseline shorter axial length were significantly associated with the treatment effect. Conclusion: The findings suggest that bifocal prismatic lenses have the potential to be an effective intervention for managing myopia in children, particularly those with high rates of progression. However, further research with larger sample sizes and longer follow-up periods is needed to fully understand the long-term impacts of this treatment approach.
- 21 September 2024
- Published by Sakarya Tip Dergisi in Sakarya Medical Journal
The Efficacy of Prismatic Bifocal Spectacle Lenses in Controlling Myopia Progression in Children.
Objective: Progression of myopia can lead to vision impairment and increase the risk of sight-threatening complications. Various strategies were described to control the progression of myopia, including the use of specialized spectacle. This retrospective study aimed to analyze the efficacy of prismatic bifocal spectacle lenses in controlling the progression of myopia in pediatric patients. Materials and Methods: Fifty-two eyes of 26 patients using prismatic bifocal spectacle lenses were retrospectively analyzed. Both eyes of each patient with a cycloplegic objective refraction measurement of ≥-2.00 D were included. Demographic data of the patients such as age and gender were investigated. The increase in objective spherical equivalent and axial length over the one year of single-vision spectacle use was compared with the increase observed one year after the prescription of bifocal prismatic spectacle. Results: The mean age of the patients was 11.65 ± 2.70 years. Sixteen patients were male, and 10 patients were female. The increase in mean spherical equivalent in eyes using single vision spectacles over one year was 1.25 ± 0.76 D, compared to 0.24 ± 0.14 D with prismatic bifocal spectacles, which was statistically significant). Similarly, the increase in mean axial length was 0.66 ± 0.31 mm with single vision spectacles and 0.014 ± 0.015 mm with bifocal spectacle, also statistically significant Multiple linear regression analysis revealed that baseline higher myopia and baseline shorter axial length were significantly associated with the treatment effect. Conclusion: The findings suggest that bifocal prismatic lenses have the potential to be an effective intervention for managing myopia in children, particularly those with high rates of progression. However, further research with larger sample sizes and longer follow-up periods is needed to fully understand the long-term impacts of this treatment approach.
- 5 August 2024
- Published by Springer Nature in International Ophthalmology
- Vol. 44 (1) , 1-10
Use of a dexamethasone implant to treat macular edema following pars plana vitrectomy and removal of the primary epiretinal membrane
Purpose The purpose of this study was to evaluate the effectiveness and safety of an intravitreal dexamethasone (DEX) implant for the treatment of macular edema (ME) following pars plana vitrectomy (PPV) and removal of the primary epiretinal membrane (ERM) and to assess the impact of the integrity of the ellipsoid zone (EZ) and disorganization of the retinal inner layer (DRIL) grade on visual and anatomical outcomes. Methods Forty-two pseudophakic patients who developed ME following PPV and removal of the primary stage 2–3 ERM were included. Patients were divided into two groups when ME was diagnosed via spectral domain optic coherence tomography (SD-OCT). In the DEX group (n = 22), DEX was implanted for the treatment of ME. In the control group (n = 20), only observation was conducted, without any treatment. The best-corrected visual acuity (BCVA) and macular thickness (MT) of the two groups were compared at baseline and 1, 6, and 12 months after DEX implantation. The effects of OCT parameters such as EZ integrity and DRIL grade were also evaluated in terms of decreases in MT and increases in VA in the treatment of ME with DEX implantation. Intraocular pressure (IOP), number of DEX implantations and adverse effects were also recorded. Results While a statistically significant increase in the mean BCVA was observed in the DEX group (p < 0.001 at months 1, 6, and 12, respectively), no such increase was detected in the control group (p = 0.169, p = 0.065, and p = 0.058 at months 1, 6 and 12, respectively) compared with the baseline. A statistically significant decrease in the mean MT was observed in the DEX group (p < 0.001 at months 1, 6, and 12); however, no significant difference was observed in the control group (p = 0.081, p = 0.065, and p = 0.054 at months 1, 6 and 12, respectively) compared with the baseline. Significant differences were found between the two groups in terms of the increase in BCVA (p < 0.01) and decrease in MT (p < 0.01) at all visits, with the outcomes being more favorable in the DEX group. A statistically significant relationship was found between the increase in VA and EZ integrity and DRIL grade in both groups. Ten patients (45.4%) received two injections of DEX during the follow-up. An increase in IOP was observed in five patients (22.7%) who were treated with topical antiglaucomatous drops. No significant side effects were observed. Conclusion DEX implantation was found to be effective and safe for the treatment of ME following PPV and primary ERM removal, although some eyes may require repeated injections to achieve visual and anatomical success. Additionally, a relationship was found between EZ integrity, DRIL grade and visual-anatomical outcomes.
- 5 August 2024
- Published by Springer Nature in International Ophthalmology
- Vol. 44 (1) , 1-10
Use of a dexamethasone implant to treat macular edema following pars plana vitrectomy and removal of the primary epiretinal membrane
Purpose The purpose of this study was to evaluate the effectiveness and safety of an intravitreal dexamethasone (DEX) implant for the treatment of macular edema (ME) following pars plana vitrectomy (PPV) and removal of the primary epiretinal membrane (ERM) and to assess the impact of the integrity of the ellipsoid zone (EZ) and disorganization of the retinal inner layer (DRIL) grade on visual and anatomical outcomes. Methods Forty-two pseudophakic patients who developed ME following PPV and removal of the primary stage 2–3 ERM were included. Patients were divided into two groups when ME was diagnosed via spectral domain optic coherence tomography (SD-OCT). In the DEX group (n = 22), DEX was implanted for the treatment of ME. In the control group (n = 20), only observation was conducted, without any treatment. The best-corrected visual acuity (BCVA) and macular thickness (MT) of the two groups were compared at baseline and 1, 6, and 12 months after DEX implantation. The effects of OCT parameters such as EZ integrity and DRIL grade were also evaluated in terms of decreases in MT and increases in VA in the treatment of ME with DEX implantation. Intraocular pressure (IOP), number of DEX implantations and adverse effects were also recorded. Results While a statistically significant increase in the mean BCVA was observed in the DEX group (p < 0.001 at months 1, 6, and 12, respectively), no such increase was detected in the control group (p = 0.169, p = 0.065, and p = 0.058 at months 1, 6 and 12, respectively) compared with the baseline. A statistically significant decrease in the mean MT was observed in the DEX group (p < 0.001 at months 1, 6, and 12); however, no significant difference was observed in the control group (p = 0.081, p = 0.065, and p = 0.054 at months 1, 6 and 12, respectively) compared with the baseline. Significant differences were found between the two groups in terms of the increase in BCVA (p < 0.01) and decrease in MT (p < 0.01) at all visits, with the outcomes being more favorable in the DEX group. A statistically significant relationship was found between the increase in VA and EZ integrity and DRIL grade in both groups. Ten patients (45.4%) received two injections of DEX during the follow-up. An increase in IOP was observed in five patients (22.7%) who were treated with topical antiglaucomatous drops. No significant side effects were observed. Conclusion DEX implantation was found to be effective and safe for the treatment of ME following PPV and primary ERM removal, although some eyes may require repeated injections to achieve visual and anatomical success. Additionally, a relationship was found between EZ integrity, DRIL grade and visual-anatomical outcomes.
- Open Access
- 30 July 2024
- Published by Wolters Kluwer Health in Indian Journal of Ophthalmology - Case Reports
- Vol. 4 (3) , 633-634
Bilateral cataract related to the use of methylphenidate in a 10-year-old girl
The purpose of the case report is to highlight the fact that the use of methylphenidate (MPH) treatment for attention deficit hyperactivity disorder (ADHD) causes bilateral cataracts. A 10-year-old girl was referred to us for blurred vision using MPH 30 mg/day for four years. A complete cataract in the right eye with a perception of light visual acuity (VA) and a posterior subcapsular cataract in the left eye with 6/20 VA were observed. After cataract surgery, VA was 20/20 in both eyes. Increasing norepinephrine and dopamine levels in the aqueous with the use of MPH may induce the inflammation that causes cataract.
- 30 July 2024
- Published by Wolters Kluwer Health in Indian Journal of Ophthalmology - Case Reports
- Vol. 4 (3) , 633-634
Open AccessBilateral cataract related to the use of methylphenidate in a 10-year-old girl
The purpose of the case report is to highlight the fact that the use of methylphenidate (MPH) treatment for attention deficit hyperactivity disorder (ADHD) causes bilateral cataracts. A 10-year-old girl was referred to us for blurred vision using MPH 30 mg/day for four years. A complete cataract in the right eye with a perception of light visual acuity (VA) and a posterior subcapsular cataract in the left eye with 6/20 VA were observed. After cataract surgery, VA was 20/20 in both eyes. Increasing norepinephrine and dopamine levels in the aqueous with the use of MPH may induce the inflammation that causes cataract.
- Open Access
- 1 January 2024
- Published by Turkiye Klinikleri in Turkiye Klinikleri Journal of Ophthalmology
- Vol. 33 (3) , 156-162
Prognosis and Cost Effectiveness of the Monocanalicular Intubation with Re-Sterilized Silicone Tubes in Canalicular Lacerations: Observational Case Series
Objective: Canalicular lacerations are usually treated with monocanalicular or bicanalicular silicon stent intubation. This study aimed to report the prognosis and cost-effectiveness of monocanalicular intubation using re-sterilized silicone tubes for canalicular lacerations. Material and Methods: Patient demographics, surgery timing, surgical time, postoperative treatment, follow-up, timing of the silicon tube removal, and postoperative lacrimal patency (anatomical success) and subjective epiphora (functional success) were investigated. Five-centimeter silicone tubes remaining from dacryocystorhinostomy surgery, re-sterilized with ethylene oxide, were used. The silicone tube was left approximately 1.5 centimeters beyond the lacrimal punctum to avoid corneal contact. The free end of the tube was sutured to the skin and orbicularis muscle, positioning it downward. Anatomical success was determined with the lacrimal irrigation test upon removal, and functional success was assessed using the Munk score. Results: Twenty-seven patients with an average age of 47.5 years and a mean follow-up of 7.6 months were included. Canalicular reconstruction was performed within 24 hours of injury, with an average surgical time of 24.7 minutes. No intraoperative complications, ocular surface irritation, stent migration, spontaneous stent loss, or infection were observed. Granuloma formation occurred in one (3.7%) patient, and medial ectropion of the lower eyelid in one (3.7%) patient. Anatomical success was 100%, and functional success was 96.2%. Conclusion: Repairing lacerated canaliculi with re-sterilized silicon tubes was successful and cost-effective. This technique avoids manipulation of the uninjured canaliculus, making tube insertion and removal straightforward. Its significant advantage is the lack of additional costs or instruments, valuable during limited instrument availability, such as the COVID-19 pandemic.
- 1 January 2024
- Published by Turkiye Klinikleri in Turkiye Klinikleri Journal of Ophthalmology
- Vol. 33 (3) , 156-162
Open AccessPrognosis and Cost Effectiveness of the Monocanalicular Intubation with Re-Sterilized Silicone Tubes in Canalicular Lacerations: Observational Case Series
Objective: Canalicular lacerations are usually treated with monocanalicular or bicanalicular silicon stent intubation. This study aimed to report the prognosis and cost-effectiveness of monocanalicular intubation using re-sterilized silicone tubes for canalicular lacerations. Material and Methods: Patient demographics, surgery timing, surgical time, postoperative treatment, follow-up, timing of the silicon tube removal, and postoperative lacrimal patency (anatomical success) and subjective epiphora (functional success) were investigated. Five-centimeter silicone tubes remaining from dacryocystorhinostomy surgery, re-sterilized with ethylene oxide, were used. The silicone tube was left approximately 1.5 centimeters beyond the lacrimal punctum to avoid corneal contact. The free end of the tube was sutured to the skin and orbicularis muscle, positioning it downward. Anatomical success was determined with the lacrimal irrigation test upon removal, and functional success was assessed using the Munk score. Results: Twenty-seven patients with an average age of 47.5 years and a mean follow-up of 7.6 months were included. Canalicular reconstruction was performed within 24 hours of injury, with an average surgical time of 24.7 minutes. No intraoperative complications, ocular surface irritation, stent migration, spontaneous stent loss, or infection were observed. Granuloma formation occurred in one (3.7%) patient, and medial ectropion of the lower eyelid in one (3.7%) patient. Anatomical success was 100%, and functional success was 96.2%. Conclusion: Repairing lacerated canaliculi with re-sterilized silicon tubes was successful and cost-effective. This technique avoids manipulation of the uninjured canaliculus, making tube insertion and removal straightforward. Its significant advantage is the lack of additional costs or instruments, valuable during limited instrument availability, such as the COVID-19 pandemic.