SPSurya Dewi Puspitasari

Surya Dewi Puspitasari

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Surya Dewi Puspitasari has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Deterioration models for predicting RC structures of port mooring facilities condition: A review

    by Surya Dewi Puspitasari, Pengyong Miao, Anasya Arsita Laksmi, Muhammad Hamzah Fansuri, Wibby Aldryani Astuti Praditasari

    Maritime transportation plays a vital role with approximately 90% of goods being transported by sea. It is essential to ensure uninterrupted port operations to Maritime transportation plays a vital role with approximately 90% of goods being transported by sea. It is essential to ensure uninterrupted port operations to

  • Open Access

    PEMANFAATAN BUILDING INFORMATION MODELLING (BIM) PADA PERANCANGAN STRUKTUR BAJA TERHADAP BEBAN GEMPA

    by Pinta Astuti, Rangga Kurnianto, Surya Dewi Puspitasari

    This study focuses on designing the steel structure construction toward earthquake load, which uses Istana Qur’an as a research object. Modeling and designing the steel structural building by using two different software, SAP2000, and Tekla Structure. In the making process, the authors made presumptions on workload according to Indonesian Design Standards such as minimum design loads, seismic load design, seismic load for steel structure design, and joints in steel structure. Not only from a structural strength view for human safety but also the construction time and material cost are also able to be estimated which is becoming faster and more affordable compared to implementing the conventional method. As a full analysis result, in this steel design, there are six different steel profiles were used for steel building construction. For instance, IWF 440.300.11.18 as the column, IWF 350.175.7.11 and IWF 250.125.6.9 as the beams, IWF 200.100.5,5.8 as the gable roof frame, UNP 150.75.9.12,5 as purlin and L 150.150.15 as collar tie.


  • Corrosion assessment of steel bar in concrete by using electrochemical test method

    by Pinta Astuti, Adhitya Yoga Purnama, Surya Dewi Puspitasari, Sabrina Harahap

    The assessment of steel corrosion in concrete is the global concern, particularly for RC structures in hostile environments. Despite a decade of rigorous research on steel corrosion in concrete, measuring corrosion technology continues to present. This study provided a comprehensive overview of corrosion evaluation using electrochemical methods, such as half-cell potential measurement, electrical resistivity of concrete, and rate of corrosion, after explaining the corrosion process. Half-cell potential measurement has proved a highly valuable, method of non-destructive for locating corrosion regions for monitoring, condition assessment, and estimating repair efficacy. The resistivity of concrete may reveal the permeable areas, where the penetration of chloride is most likely to be rapid and value of rate of corrosion in the future will be the highest; appropriate preventive action can be taken. Corrosion rates are classified as the average value and direct value of rate of corrosion. The average value of rate of corrosion is the medium for a long time period of measurement process by checking the weight loss or cross-sectional loss of steel bars. In contrast, the direct rate of corrosion can be measured electrochemically, specifically resistance of polarization tests. The goal of this work is not only to provide information on concrete corrosion assessment, but also to shed light on modern corrosion assessment techniques for accurate and rapid detection.

  • Open Access

    Application of permeable pavement in urban roads as an alternative flooding reduction in Jakarta

    by Surya Dewi Puspitasari, Laura Elvirandra, Muhammad Bagus Yulistian, Rena Avinika Ningtyas, Sabrina Harahap, Oktaviani Tri Handayani, Pinta Astuti

    Over decades, urban roads in Jakarta have been suffering from flooding due to excessive surface runoff. A majority of existing urban road pavement installation in Jakarta has been utilizing the conventional pavement type. A typical conventional pavement is ineffective in reducing the surface runoff volume, particularly during high precipitation events. All stormwater has to flow onto the drainage with extreme discharge. As a consequence, the urban roads are full of puddles of various heights and lengths of time. To reflect on this issue, the authors conducted a review paper, to sum up, the extensive but dispersed literature on commonly permeable pavements. This study reviewed porous asphalt, pervious concrete, and interlocking concrete pavers. In addition, four crucial points are highlighted as consideration: (1) the structural capability, (2) permeability, (3) water quality and (4) economic risk. This research review concluded that permeable pavement is more effective in reducing flooding compared to conventional pavement. Among those three pavement types, porous asphalt pavement is the most possible to be implemented for urban roads in Jakarta, especially for light traffic. Since this pavement meets the Indonesian national standard requirements for structural capability and has less economic risk.


  • A study on the application of piezoelectric based – Early warning system for earthquake hazard

    by Rahmad Afriansya, Evelyn Anabela Anisa, Pinta Astuti, Surya Dewi Puspitasari

    Earthquakes are one of the disasters that often occur in Indonesia. This disaster causes severe vibrations in buildings, which impact structural failure so that a building can suffer damage or even destruction. Based on official data from BNPB, from 2000-2020, there were 282 earthquake cases in Indonesia, up to 71,174 fatalities. For example, a tectonic earthquake with a magnitude of 5.9 SR for 57 seconds struck D.I Yogyakarta and parts of Central Java in 2006, to be precise, at 05:55 WIB, claiming more than 6000 lives. A large number of casualties was caused by the community’s unpreparedness for the earthquake that occurred. The risk of earthquakes is greatest from night to morning when the majority of the population is resting. Therefore, it is necessary to innovate and educate the public about disaster mitigation in the form of technological innovation in early warning of earthquake disasters. This system is a piezoelectric sensor that is planted in the ground. This piezoelectric sensor works when a vibration occurs due to an earthquake. The sensor can work when the land perception occurs> 0.14 m / s2, which is included in the medium scale earthquake categorized as Meecally scale IV. In this study, historical data for the 2006 Yogyakarta earthquake which occurred at a depth of 12.5 km, precisely at the coordinates of 7,977o South Latitude and 110,318 East Longitude, with an epicenter position as far as 20 km and a hypocenter distance of 23.5 km with the ground acceleration method from Donovan (1973) and Estave (1970). The results obtained meecally IV scale with digital microcontroller (ADC)> 11.55 and sensor voltage value (V)> 0.056 so that it can activate the sensor and turn on the siren as an early warning.

  • Open Access

    Effects of various factors on behaviors of piles and foundation soils due to seismic shaking

    by Muhammad Hamzah Fansuri, Muhsiung Chang, Pungky Dharma Saputra, Nina Purwanti, Anasya Arsita Laksmi, Sabrina Harahap, Surya Dewi Puspitasari


  • A Critical Review of Bridge Management System in Indonesia

    by Surya Dewi Puspitasari, Sabrina Harahap, Pinta Astuti