MZMei-Ling Zhuang

Mei-Ling Zhuang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mei-Ling Zhuang has a total of 92 co-authors. Here are the top co-authors by number of shared publications:

  • Chuanzhi Sun

    Lecturer, School of Civil Engineering and Architecture, Suqian College, Suqian 223800, China; Lecturer, Jiangsu Province Engineering Research Center of Prefabricated Building and Intelligent Construction, Suqian College, Suqian 223800, China

    8 shared publications
  • Li Gao

    Professor, School of Civil Engineering and Architecture, Suqian College, Suqian 223800, China; Professor, Jiangsu Province Engineering Research Center of Prefabricated Building and Intelligent Construction, Suqian College, Suqian 223800, China

    6 shared publications
  • Li Gao

    School of Civil Engineering and Architecture, Suqian University, Suqian 223800, China

    4 shared publications
  • Hanbo Zhu

    School of Civil Engineering and Architecture, Suqian College , Suqian , 223800 , China

    3 shared publications
  • Weihua Zhang

    Senior Engineer, Yigongju Bridge & Tunnel Engineering Co., Ltd., No. 688, 2nd Section, South Wanjiali St., Changsha 410000, China

    3 shared publications
  • Yan Qiao

    Professor, School of Civil Engineering and Architecture, Suqian College, Suqian 223800, China

    3 shared publications

Latest Publications

  • Open Access

    Effect of Different Adhesives on the Bonding Performance of the CFRP–Steel Interface

    by Qin Wang, Wenhao Guo, Li Gao, Luchang Li, Mengda Zhao, Mei-Ling Zhuang, Chuanzhi Sun, Fuhe Ge

    This study investigates the influence of adhesive type on the bond performance between CFRP plates and steel interfaces through static tensile double-shear tests. Three types of adhesives (Araldite 420A/B, 2015-1, Sikadur-30CN) were tested under four bond lengths. The results indicate that adhesive strength significantly affects failure characteristics, with distinct material performance differences observed. Bond length influences the stress distribution, enhancing dispersion while potentially altering damage progression. High-performance adhesives exhibit superior shear resistance and fracture energy due to improved viscous properties, whereas moderately plastic adhesives achieve adaptive deformation and durable bonding by enhancing the flow and substrate contact. These findings provide a theoretical basis for material selection in CFRP-strengthened steel structures and offer actionable guidance for structural repair engineering applications.

  • Open Access

    Experimental Study on the Seismic Behavior of Concrete Columns with 630 MPa High-Strength Stirrups

    by Mei-Ling Zhuang, Jibing Deng, Chuanzhi Sun, Li Gao, Xihan Zhong, Zijun Tang, Pingping Gu

    The widespread adoption of high-strength steel reinforcement in China has driven a growing demand for 600 MPa grade and higher-strength stirrups in engineering applications. This study experimentally investigates the seismic performance of concrete columns reinforced with 630 MPa high-strength steel stirrups. Six concrete columns were designed and fabricated, incorporating key variables including concrete strength, stirrup strength, and stirrup spacing ratio. Low-cycle reversed loading tests were subsequently conducted on these specimens, enabling a thorough evaluation of their seismic characteristics. Additionally, the study examines the cumulative damage effects and confining influence of 630 MPa high-strength stirrups on the core concrete. The findings reveal that concrete columns with a low ratio of 630 MPa high-strength stirrups exhibit enhanced seismic performance when the concrete strength is relatively low. However, with increasing concrete strength, the confinement efficiency of 630 MPa ultra-high-strength stirrups diminishes, leading to accelerated damage progression and reduced ductility. Both low- and high-strength concrete columns benefit from a high stirrup ratio, which provides effective confinement. Furthermore, 630 MPa high-strength stirrups help mitigate damage accumulation while enhancing yield displacement, peak displacement, ultimate displacement, ductility, and energy dissipation capacity. The use of 630 MPa high-strength stirrups not only ensures superior seismic performance but also reduces reinforcement requirements and improves construction efficiency.


  • Unconfined Compressive Strength Optimization of Industrial Solid Waste-Based Soil Stabilizers

    by Y. Z. Wang, F. Y. Chen, Y. Gao, M. L. Zhuang, F. H. Ge, Z. J. Tang


  • Open Access

    Effect of Traffic Vibration on Compressive Strength of High-Strength Concrete and Tensile Strength of New-to-Old Concrete Interfaces

    by Pingping Gu, Hao Wu, Luchang Li, Zhanghao Li, Jingyi Hong, Mei-Ling Zhuang

    Widening existing bridges is an important way to meet the surge in traffic demand, which is often carried out in a way that does not interrupt traffic. To investigate the effect of traffic vibration on the compressive strength of high-strength concrete and the splitting strength of new-to-old concrete interfaces, the initial to final set time of high-strength concrete C60 was first investigated in this article. Then, the traffic disturbance parameters were determined. Later, the compressive strength of C60 concrete at different stages under traffic disturbance parameters was carried out. Finally, the splitting tensile strength of new-to-old concrete specimens at different stages with different loading modes was tested. The test results indicated that the compressive strength of the specimens vibrated for 3 h and cured for 3, 7, and 28 days was increased by 4.3%, 5.7%, and 11.9%, respectively; those of the specimens vibrated for 7 h and cured for 3, 7, and 28 days was decreased by 13.7%, 20.4%, and 19.9%, respectively; the effect traffic vibration on the compressive strength of the specimens vibrated for 5 h was not obvious. When loaded along the old and new concrete joint, the specimens cracked along the joint; the splitting tensile strengths of the specimen at different disturbed stages were significantly decreased. When loaded perpendicular to the joint, the specimens cured for 3 and 7 days still cracked along the joint, and the splitting tensile strengths of the specimen at different disturbed stages were significantly decreased; while the specimens cured for 28 days cracked in the direction perpendicular to the joint, the tensile strengths of the specimens at different disturbed stages were significantly decreased. This study can promote the widening and improvement of existing concrete highways and bridges, which can save resources and improve land use.


  • Open Access

    Experimental Investigations on the On-Site Crack Control of Pier Concrete in High-Altitude Environments

    by Xiaochuan Hu, Lei Liu, Manping Liao, Ming Li, Cun Lu, Zaifeng Yao, Qiuming Huang, Mei-Ling Zhuang

    Concrete structures in high-altitude environments face many challenges. Establishing concrete crack control methods in high-altitude environments is crucial for enhancing the service capacity of concrete structures. In this study, a multi-field (hydration-temperature–humidity-constraint) coupling model was used to quantitatively assess the cracking risk of pier bodies at high altitude. On-site crack control tests were conducted on pier bodies using a micro-expansion anti-cracking agent to demonstrate the effectiveness of deformation shrinkage compensation in crack control at high altitudes. The results indicated that there was a risk of cracking in the pier body at high-altitude conditions, especially within 0.3 m from the pile cap and ±2.5 m from the center of the pier side surface. Compared with conventional piers, the micro-expansion anti-cracking agent approximately doubled the unit expansion deflection of piers at high temperatures while reducing the unit shrinkage deflection of piers by 11% to 12% at low temperatures. The concrete in conventional pier bodies was in a tension state after long-term hardening, while the concrete treated with the micro-expansive anti-cracking agent was in compression. Therefore, the deformation compensation effect of the micro-expansive anti-cracking agent was significant and reduced the risk of concrete cracking. In addition, early freezing had a significant impact on concrete strength, underscoring the importance of effective temperature control during the early stages of concrete placement in high-altitude environments.


  • Open Access

    Inversion Analysis for Thermal Parameters of Mass Concrete Based on the Sparrow Search Algorithm Improved by Mixed Strategies

    by Yang Wang, Yang Gao, Kaixing Zhang, Mei-Ling Zhuang, Runze Xu, Xiumin Yan, Youzhi Wang

    In the traditional mass concrete temperature field calculation, the accuracy of the thermal parameters is extremely important. However, the actual thermal parameters of mass concrete may have some errors with the laboratory-measured values or specification values due to the site ambient temperature, concrete surface insulation measures, cooling water flow, etc. Therefore, it can be combined with the measured temperature of the field temperature sensors using the sparrow search algorithm (SSA) for the inverse analysis of thermal parameters. Firstly, to address the problem that SSA has low convergence accuracy and easily falls into local optimum, a mixed strategy was adopted to improve the algorithm, including Logistic Chaos mapping initialization of the population, the introduction of adaptive weighting factors, and the use of the Cauchy mutation strategy. Then, the performance test was carried out to compare the performance of the algorithm with three different intelligent algorithms and reflect the superiority of the SSA that was improved by mixed strategies (SSAIMSs). Finally, the proposed method was applied to the thermal parameter inversion of a mass concrete pile cap. The inversion results demonstrated that SSAIMSs can improve the accuracy and speed of thermal parameter inversion, and the calculated results of the thermal parameters and temperatures obtained using the SSAIMSs matched well with the measured results in the field, which can meet the accuracy requirements of the actual engineering.


  • Study on the Causes of Asymmetric Cracking of Plateau Concrete Bridge Piers

    by X. C. Hu, H. Hu, M.-L. Zhuang, T. C. Wang, H. H. Jiang, X. Z. Ding


  • Open Access

    Investigations on the Environmental Characteristics and Cracking Control of Plateau Concrete

    by Xiaochuan Hu, Manping Liao, Ming Li, Fuqiang Wang, Xiang Lyu, Mei-Ling Zhuang

    In the present study, first, the environmental challenges and cracking characteristics during the construction of plateau concrete on the Sichuan–Tibet route were revealed. Then, using a multi-field coupled shrinkage model with hydration temperature humidity constraints, the early and long-term cracking risks in the core of plateau pier bodies were investigated. Later, the effects of tensile strength, pouring interval age and adiabatic temperature rise on the cracking risk were analyzed. Finally, various control measures for high-altitude concrete cracking were proposed. The results indicated that the complex environment of the plateau led to different forms of cracks in the pier body, especially vertical cracks in the straight sections. The long-term risk of core cracking in the plateau pier body is significantly greater than the risk of early cracking. This risk was strongly influenced by factors such as the concrete tensile strength, pouring interval age and adiabatic temperature rise, which should be given more attention. Deformation compensation can significantly enhance the peak and residual deformation capacities of plateau concrete, with peak values greater than 900 με and residual deformation greater than 200 με at day 60, as well as its resistance to cracking. Strategies such as adopting radiant cooling techniques, improving construction techniques and implementing effective management measures can all play a vital role in improving the cracking resistance of highland concrete.


  • Open Access

    Displacement and Internal Force Response of Mechanically Connected Precast Piles Subjected to Horizontal Load Based on the m-Method

    by Li Gao, Mei-Ling Zhuang, Qunqun Zhang, Guangdong Bao, Xiaoyang Yu, Jiahao Du, Shengbo Zhou, Mingsen Wang

    Mechanically connected precast piles are a type of precast piles that utilise snap-type mechanical connectors to restrain the pile ends of two identical or different precast piles at the top and bottom so as to quickly realise the purpose of the connection. However, the gap problem in the connectors of mechanically connected piles can lead to uneven and uniform deformation of the piles under horizontal loading, resulting in additional displacements and rotation angles of the piles at the connection. Solving the problem of calculating the internal force response of discontinuous deformed piles is a prerequisite for promoting and applying mechanically connected precast piles. Firstly, the theoretical derivation of mechanically connected piles with fixed constraints at the pile bottom is carried out. Secondly, the pile response equations of mechanically connected piles are established, and the theoretical solutions of pile displacement and internal force response of mechanically connected piles under horizontal loading are derived. Thirdly, the pile-soil model of the test pile is established using ABAQUS software (ABAQUS 2016) in combination with the design data of the test pile. The numerical simulation displacements and angles of rotation are compared with the test results. Finally, the theoretical and numerical simulation displacements and internal forces of the ordinary pile and the mechanically connected pile are compared. The relative errors of the displacements and angles of rotation of the established pile-soil model are less than 10%, indicating that the established model has good accuracy. The relative errors of the theoretical and numerical simulation displacements and internal forces of the mechanically connected pile are less than 10%, proving the correctness of the theoretical calculation by the m-method. This study can provide effective theoretical support and methodological guidance for the displacement and internal force response of discontinuous piles.