Natallia Lapitskaya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Natallia Lapitskaya has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Bjarne Møller-Madsen
Danish Paedatric Orthopaedic Research, Aarhus University Hospital, Aarhus, Denmark
3 shared publications - Hans-Christen Husum
Department of Radiology Randers Regional Hospital Randers Denmark
3 shared publications - Mads Henriksen
Danish Paedatric Orthopaedic Research, Aarhus University Hospital, Aarhus, Denmark
3 shared publications - Michel Bach Hellfritzsch
Danish Paedatric Orthopaedic Research, Aarhus University Hospital, Aarhus, Denmark
3 shared publications - Ole Rahbek
Aarhus University Hospital
3 shared publications - Rikke Damkjær Maimburg
Department of Midwifery, University College of Northern Denmark, Aalborg, Denmark; Department of Occupational Health, Aarhus University Hospital, Aarhus, Denmark; Department of Clinical Medicine, Aarhus University, Aarhus, Denmark; School of Nursing and Midwifery, Western Sydney University, Penrith, Australia
3 shared publications
Latest Publications
- Open Access
- 3 February 2025
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 6 (2) , 119-125
Age-optimized cut-off values for pubofemoral distances in screening for hip dysplasia
Aims: To establish cut-off values for lateral pubofemoral distance (PFD) measurements for detecting hip dysplasia in early (four days) and standard care (six weeks) screening for developmental dysplasia of the hip (DDH).Methods: All newborns, during a one-year period (October 2021 to October 2022), were offered a PFD ultrasound (US) examination in addition to the existing screening programme for DDH. Newborns who were referred for standard care hip US, suspected for DDH, received a secondary PFD US examination in conjunction with the standard care Graf/Harcke hip US examination. Receiver operating characteristic curves and empirically optimal cut-off values were calculated with a true positive defined as a Graf type ≥ IIc hip.Results: We included 2,735 newborns, of whom 758 received both early PFD hip US and standard care Graf/Harcke hip US. For early (four days) PFD screening, the optimal cut-off point was calculated to be 6.2 mm (95% CI 4.7 to 7.7) producing a sensitivity of 80% (95% CI 55% to 100%) and a specificity of 87% (86% to 89%). For PFD screening performed at standard care (six weeks) hip US, the optimal cut-off point was calculated to be 5.6 mm (95% CI 4.9 to 6.3) producing a sensitivity of 100% (95% CI 100% to 100%) and a specificity of 96% (95% CI 95% to 97%).Conclusion: PFD US screening produces a high degree of both sensitivity and specificity for detecting DDH. Age-specific cut-off values should be used to heighten the accuracy of PFD US screening.Cite this article: Bone Jt Open 2025;6(2):119–125.
- 3 February 2025
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 6 (2) , 119-125
Open AccessAge-optimized cut-off values for pubofemoral distances in screening for hip dysplasia
Aims: To establish cut-off values for lateral pubofemoral distance (PFD) measurements for detecting hip dysplasia in early (four days) and standard care (six weeks) screening for developmental dysplasia of the hip (DDH).Methods: All newborns, during a one-year period (October 2021 to October 2022), were offered a PFD ultrasound (US) examination in addition to the existing screening programme for DDH. Newborns who were referred for standard care hip US, suspected for DDH, received a secondary PFD US examination in conjunction with the standard care Graf/Harcke hip US examination. Receiver operating characteristic curves and empirically optimal cut-off values were calculated with a true positive defined as a Graf type ≥ IIc hip.Results: We included 2,735 newborns, of whom 758 received both early PFD hip US and standard care Graf/Harcke hip US. For early (four days) PFD screening, the optimal cut-off point was calculated to be 6.2 mm (95% CI 4.7 to 7.7) producing a sensitivity of 80% (95% CI 55% to 100%) and a specificity of 87% (86% to 89%). For PFD screening performed at standard care (six weeks) hip US, the optimal cut-off point was calculated to be 5.6 mm (95% CI 4.9 to 6.3) producing a sensitivity of 100% (95% CI 100% to 100%) and a specificity of 96% (95% CI 95% to 97%).Conclusion: PFD US screening produces a high degree of both sensitivity and specificity for detecting DDH. Age-specific cut-off values should be used to heighten the accuracy of PFD US screening.Cite this article: Bone Jt Open 2025;6(2):119–125.
- Open Access
- 2 January 2024
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 5 (1) , 3-8
Pubofemoral distances correlate to acetabular morphology and sonological instability in screening for hip dysplasia
Pubofemoral distances correlate to acetabular morphology and sonological instability in screening for hip dysplasia
- 2 January 2024
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 5 (1) , 3-8
Open AccessPubofemoral distances correlate to acetabular morphology and sonological instability in screening for hip dysplasia
Pubofemoral distances correlate to acetabular morphology and sonological instability in screening for hip dysplasia
- Open Access
Pubo-Femoral Distances Measured Reliably by Midwives in Hip Dysplasia Ultrasound
The pubo-femoral distance (PFD) has been suggested as an ultrasound screening tool for developmental dysplasia of the hip (DDH). The aim of this study was to examine if midwives undergoing minimal training could reliably perform pediatric hip ultrasound and PFD measurements. Eight recruited midwives performed two rounds of independent blinded PFD measurements on 15 static ultrasound images and participated in four supervised live-scanning sessions. The midwives were compared to a group of three experienced musculoskeletal radiologists. Reliability was evaluated using inter-rater correlation coefficients (ICC). Linear regression was used to quantify the learning curve of the midwives as a group. There was near complete intra- and inter-rater agreement (ICC > 0.89) on static ultrasound images across both rounds of rating for midwives and radiologists. The midwives performed a mean of 29 live hip scans (range 24–35). The mean difference between midwives and supervising radiologists was 0.36 mm, 95% CI (0.12–0.61) for the first session, which decreased to 0.20 mm, 95% CI (0.04–0.37) in the fourth session. ICC for PFD measurements increased from 0.59 mm, 95% CI (0.37–0.75) to 0.78 mm, 95% CI (0.66–0.86) with progression in sessions. We conclude that midwives reliably perform PFD measurements of pediatric hips with minimal training.
Open AccessPubo-Femoral Distances Measured Reliably by Midwives in Hip Dysplasia Ultrasound
The pubo-femoral distance (PFD) has been suggested as an ultrasound screening tool for developmental dysplasia of the hip (DDH). The aim of this study was to examine if midwives undergoing minimal training could reliably perform pediatric hip ultrasound and PFD measurements. Eight recruited midwives performed two rounds of independent blinded PFD measurements on 15 static ultrasound images and participated in four supervised live-scanning sessions. The midwives were compared to a group of three experienced musculoskeletal radiologists. Reliability was evaluated using inter-rater correlation coefficients (ICC). Linear regression was used to quantify the learning curve of the midwives as a group. There was near complete intra- and inter-rater agreement (ICC > 0.89) on static ultrasound images across both rounds of rating for midwives and radiologists. The midwives performed a mean of 29 live hip scans (range 24–35). The mean difference between midwives and supervising radiologists was 0.36 mm, 95% CI (0.12–0.61) for the first session, which decreased to 0.20 mm, 95% CI (0.04–0.37) in the fourth session. ICC for PFD measurements increased from 0.59 mm, 95% CI (0.37–0.75) to 0.78 mm, 95% CI (0.66–0.86) with progression in sessions. We conclude that midwives reliably perform PFD measurements of pediatric hips with minimal training.