Mokhalad Alghrairi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Mokhalad Alghrairi has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Nasri Sulaiman
Department of Electrical and Electronic Engineering, Faculty of Engineering , Universiti Putra Malaysia , 43400 Serdang , Selangor , Malaysia
4 shared publications - Saad Mutashar
Department of Electrical, Electronic & Systems Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, 43600 UKM Bangi Selangor, Malaysia
4 shared publications - Waleed Algriree
Univ Putra Malaysia, Fac Engn, Dept Comp & Commun Syst Engn, Serdang 43400, Selangor, Malaysia
3 shared publications - Wan Zuha Wan Hasan
Department of Electrical and Electronic Engineering, Faculty of Engineering, Universiti Putra Malaysia, Serdang, Malaysia
2 shared publications - Basheer Husham Ali
Department of Electrical and Electronic Engineering, Faculty of Engineering, Universiti Putra Malaysia, Serdang 43400, Malaysia
1 shared publication - Basim Abdul Kareem Farhan
Department of Computer Techniques Engineering, Imam Alkadhim University College, 10087, Baghdad, Iraq
1 shared publication
Latest Publications
- Open Access
- 1 September 2024
- Published by IOP Publishing in Journal of Physics Communications
- Vol. 8 (9) , 092001
Advancing healthcare through piezoresistive pressure sensors: a comprehensive review of biomedical applications and performance metrics
Piezoresistive pressure sensors have transformed biomedical applications, enabling precise diagnostics and monitoring. This concise review explores the fundamental principles, key components, and fabrication techniques of piezoresistive pressure sensors, focusing on critical performance metrics such as sensitivity, accuracy, and response time. Biomedical design challenges, including biocompatibility and long-term stability, are examined, offering insights into solutions for optimal sensor integration. In diverse biomedical applications, piezoresistive pressure sensors play pivotal roles, from blood pressure monitoring to implantable medical devices. The paper emphasizes their versatility in enhancing patient care through continuous and accurate monitoring. Looking forward, the review discusses emerging trends and potential research directions, positioning piezoresistive pressure sensors as central contributors to the future of biomedical technology, promising improved patient outcomes and advanced healthcare delivery through precise and continuous monitoring.
- 1 September 2024
- Published by IOP Publishing in Journal of Physics Communications
- Vol. 8 (9) , 092001
Open AccessAdvancing healthcare through piezoresistive pressure sensors: a comprehensive review of biomedical applications and performance metrics
Piezoresistive pressure sensors have transformed biomedical applications, enabling precise diagnostics and monitoring. This concise review explores the fundamental principles, key components, and fabrication techniques of piezoresistive pressure sensors, focusing on critical performance metrics such as sensitivity, accuracy, and response time. Biomedical design challenges, including biocompatibility and long-term stability, are examined, offering insights into solutions for optimal sensor integration. In diverse biomedical applications, piezoresistive pressure sensors play pivotal roles, from blood pressure monitoring to implantable medical devices. The paper emphasizes their versatility in enhancing patient care through continuous and accurate monitoring. Looking forward, the review discusses emerging trends and potential research directions, positioning piezoresistive pressure sensors as central contributors to the future of biomedical technology, promising improved patient outcomes and advanced healthcare delivery through precise and continuous monitoring.
- Open Access
- 1 August 2024
- Published by Wydawnictwo Naukowe Gabriel Borowski (WNGB) in Advances in Science and Technology Research Journal
- Vol. 18 (4) , 273-281
Design and Analysis LCCL–LC Compensation for Electric Vehicle Systems
The shift, towards cars (EVs) plays a role in the global effort to combat climate change by reducing dependence on fossil fuels. An important part of this shift involves creating user EV charging systems. This study looks into how a connected coil design in a wireless power transfer system can...
- 1 August 2024
- Published by Wydawnictwo Naukowe Gabriel Borowski (WNGB) in Advances in Science and Technology Research Journal
- Vol. 18 (4) , 273-281
Open AccessDesign and Analysis LCCL–LC Compensation for Electric Vehicle Systems
The shift, towards cars (EVs) plays a role in the global effort to combat climate change by reducing dependence on fossil fuels. An important part of this shift involves creating user EV charging systems. This study looks into how a connected coil design in a wireless power transfer system can...
- Open Access
- 14 December 2023
- Published by Springer Nature in Research Square
Analyses Hybrid Technique Detection Multiple Input Multiple Output 5G Waveforms
The UFMC waveform is a type of physical layer, used by Cognitive Radio systems, to achieve reliable communication by using adaptive spectrum access. It is designed to provide interference-free communication without erasing the signals of the existing licensed users. The UFMC waveform is advantageous in Cognitive Radio networks because it can be very easily configured for different operating scenarios, providing both reliable and efficient communication. MIMO-UFMC-based transmissions, when used in combination with multiple-input multiple-output (MIMO) transmissions, have become widely accepted air interfaces that significantly improve spectral efficiency. This work presents a hybrid technique (HEDSLCT) as mathematical formulation of expressions that enable the analysis of ED performance based on the square-law combining (SLC) method in MIMO-UFMC systems, considering the future massive implementation of these systems in the fourth and fifth generation of mobile networks. The developed algorithms were used to conduct simulations for analyzing the performance of an ED process based on the SLC in MIMO-UFMC systems with varied numbers of transmit (Tx) and receive (Rx) communication branches. The results of these simulations enabled an evaluation of the ED performance. This paper presents an analysis of the effects of various factors, such as PU Tx power, false alarm probability, number of Tx and Rx MIMO branches, number of samples in ED process, and modulation techniques, on ED performance according to different signal-to-noise ratios. The obtained results of a comprehensive analysis showed that an appropriate selection of the evaluated factors could be used to improve the energy detection performance of multiple-input multiple-output ultra-wideband frequency-division multiplexing-based cognitive radio networks.
- 14 December 2023
- Published by Springer Nature in Research Square
Open AccessAnalyses Hybrid Technique Detection Multiple Input Multiple Output 5G Waveforms
The UFMC waveform is a type of physical layer, used by Cognitive Radio systems, to achieve reliable communication by using adaptive spectrum access. It is designed to provide interference-free communication without erasing the signals of the existing licensed users. The UFMC waveform is advantageous in Cognitive Radio networks because it can be very easily configured for different operating scenarios, providing both reliable and efficient communication. MIMO-UFMC-based transmissions, when used in combination with multiple-input multiple-output (MIMO) transmissions, have become widely accepted air interfaces that significantly improve spectral efficiency. This work presents a hybrid technique (HEDSLCT) as mathematical formulation of expressions that enable the analysis of ED performance based on the square-law combining (SLC) method in MIMO-UFMC systems, considering the future massive implementation of these systems in the fourth and fifth generation of mobile networks. The developed algorithms were used to conduct simulations for analyzing the performance of an ED process based on the SLC in MIMO-UFMC systems with varied numbers of transmit (Tx) and receive (Rx) communication branches. The results of these simulations enabled an evaluation of the ED performance. This paper presents an analysis of the effects of various factors, such as PU Tx power, false alarm probability, number of Tx and Rx MIMO branches, number of samples in ED process, and modulation techniques, on ED performance according to different signal-to-noise ratios. The obtained results of a comprehensive analysis showed that an appropriate selection of the evaluated factors could be used to improve the energy detection performance of multiple-input multiple-output ultra-wideband frequency-division multiplexing-based cognitive radio networks.
- Open Access
- 1 December 2022
- Published by AIP Publishing in AIP Advances
- Vol. 12 (12) , 125315
Designing and analyzing multi-coil multi-layers for wireless power transmission in stent restenosis coronary artery
Wireless power transfer technology features shorter power transmission distances in biomedical applications. This is a result of the small size of the implanted coils, biocompatible material conductivity, and the large distances between the receiving and transmitting coils. There have been numerous attempts to improve the power transfer efficiency across longer distances. Multiple coils, including 2-, 3-, 4-, and multi-layered coils, were previously considered. This study proposes a novel approach to achieve higher power transmission efficiency by integrating a single coil on the receiving side and three asymmetric coils on the transmitter side. As such, it delivers power to the sensor implanted within the coronary artery that monitors the blood pressure while introducing a uniquely shaped stent. The efficiency of power transmitted to the stent in its dual implanted forms, helical and zigzag helical, was examined as well, with the wireless power transmission system thereby analyzed at the 27 MHz Industrial Scientific Medical band operating frequency. For the four-coil technique, the power transmission efficiency at a distance of 25 mm between the receiver and transmitter sides by using biological human tissue as a medium between the transmission coils and the receiver stent can reach 56.42%, whereas other approaches show lower efficiencies: the three-coil method’s efficiency is 32.88%, the double-layer parallel method’s efficiency is 27.75%, the two-coil method’s efficiency is 24.76%, the triple-layer parallel method’s efficiency is 17.31%, the double-layer series method’s efficiency is 0.501%, and the triple-layer series method’s transmission efficiency is 0.092%. In addition, the suggested approach is demonstrated to be more efficient than prior designs with regard to the size of the implanted coils, which represent stents.
- 1 December 2022
- Published by AIP Publishing in AIP Advances
- Vol. 12 (12) , 125315
Open AccessDesigning and analyzing multi-coil multi-layers for wireless power transmission in stent restenosis coronary artery
Wireless power transfer technology features shorter power transmission distances in biomedical applications. This is a result of the small size of the implanted coils, biocompatible material conductivity, and the large distances between the receiving and transmitting coils. There have been numerous attempts to improve the power transfer efficiency across longer distances. Multiple coils, including 2-, 3-, 4-, and multi-layered coils, were previously considered. This study proposes a novel approach to achieve higher power transmission efficiency by integrating a single coil on the receiving side and three asymmetric coils on the transmitter side. As such, it delivers power to the sensor implanted within the coronary artery that monitors the blood pressure while introducing a uniquely shaped stent. The efficiency of power transmitted to the stent in its dual implanted forms, helical and zigzag helical, was examined as well, with the wireless power transmission system thereby analyzed at the 27 MHz Industrial Scientific Medical band operating frequency. For the four-coil technique, the power transmission efficiency at a distance of 25 mm between the receiver and transmitter sides by using biological human tissue as a medium between the transmission coils and the receiver stent can reach 56.42%, whereas other approaches show lower efficiencies: the three-coil method’s efficiency is 32.88%, the double-layer parallel method’s efficiency is 27.75%, the two-coil method’s efficiency is 24.76%, the triple-layer parallel method’s efficiency is 17.31%, the double-layer series method’s efficiency is 0.501%, and the triple-layer series method’s transmission efficiency is 0.092%. In addition, the suggested approach is demonstrated to be more efficient than prior designs with regard to the size of the implanted coils, which represent stents.
- Open Access
- 31 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 92158-92165
Design a Wireless Pressure Sensor With an Ellipse and a Circular Shape to Monitor the Pressure Within the Coronary Artery
This paper put forward the design and modeling pertaining to a wireless pressure sensor that can monitor blood pressure within the coronary artery with the help of a capacitive pressure sensor. To adjust the resonance frequency (26.78–27.09 MHz) with regards to this sensor’s applied pressure (0–30 KPa), sensor’s dimension as well as human blood pressure (0–220 mmHg), a variable capacitor in the pressure sensor has been put forward. The shape of the capacitive pressure sensor was designed to look like an Ellipse and a circle, which were assessed for their performance with regards to capacitive sensitivity and diaphragm deflection. Also, the diaphragm thickness pertaining to the capacitive pressure sensor with Ellipse and circular shapes was altered ( $0.1~\mu \text{m}$ to $0.5~\mu \text{m}$ ) while the cross-section area was kept constant at 1 mm 2 . As per the results, an invasive sensor with circular and Ellipse capacitive pressure shape that had smaller size (1) mm 2 displayed high sensitivity. The sensitivity readings for Ellipse and circular shape capacitive pressure sensor were 7.73 ff mmHg −1 and 9.94 ff mmHg −1 , respectively. Diaphragm deflection was simulated based on the COMSOL Multiphysics software, while MATLAB was employed for simulation with regards to changes in resonance frequency, capacitance, and capacitive sensitivity.
- 31 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 92158-92165
Open AccessDesign a Wireless Pressure Sensor With an Ellipse and a Circular Shape to Monitor the Pressure Within the Coronary Artery
This paper put forward the design and modeling pertaining to a wireless pressure sensor that can monitor blood pressure within the coronary artery with the help of a capacitive pressure sensor. To adjust the resonance frequency (26.78–27.09 MHz) with regards to this sensor’s applied pressure (0–30 KPa), sensor’s dimension as well as human blood pressure (0–220 mmHg), a variable capacitor in the pressure sensor has been put forward. The shape of the capacitive pressure sensor was designed to look like an Ellipse and a circle, which were assessed for their performance with regards to capacitive sensitivity and diaphragm deflection. Also, the diaphragm thickness pertaining to the capacitive pressure sensor with Ellipse and circular shapes was altered ( $0.1~\mu \text{m}$ to $0.5~\mu \text{m}$ ) while the cross-section area was kept constant at 1 mm 2 . As per the results, an invasive sensor with circular and Ellipse capacitive pressure shape that had smaller size (1) mm 2 displayed high sensitivity. The sensitivity readings for Ellipse and circular shape capacitive pressure sensor were 7.73 ff mmHg −1 and 9.94 ff mmHg −1 , respectively. Diaphragm deflection was simulated based on the COMSOL Multiphysics software, while MATLAB was employed for simulation with regards to changes in resonance frequency, capacitance, and capacitive sensitivity.
- Open Access
Identification of Distributed Denial of Services Anomalies by Using Combination of Entropy and Sequential Probabilities Ratio Test Methods
One of the most dangerous kinds of attacks affecting computers is a distributed denial of services (DDoS) attack. The main goal of this attack is to bring the targeted machine down and make their services unavailable to legal users. This can be accomplished mainly by directing many machines to send a very large number of packets toward the specified machine to consume its resources and stop it from working. We implemented a method using Java based on entropy and sequential probabilities ratio test (ESPRT) methods to identify malicious flows and their switch interfaces that aid them in passing through. Entropy (E) is the first technique, and the sequential probabilities ratio test (SPRT) is the second technique. The entropy method alone compares its results with a certain threshold in order to make a decision. The accuracy and F-scores for entropy results thus changed when the threshold values changed. Using both entropy and SPRT removed the uncertainty associated with the entropy threshold. The false positive rate was also reduced when combining both techniques. Entropy-based detection methods divide incoming traffic into groups of traffic that have the same size. The size of these groups is determined by a parameter called window size. The Defense Advanced Research Projects Agency (DARPA) 1998, DARPA2000, and Canadian Institute for Cybersecurity (CIC-DDoS2019) databases were used to evaluate the implementation of this method. The metric of a confusion matrix was used to compare the ESPRT results with the results of other methods. The accuracy and f-scores for the DARPA 1998 dataset were 0.995 and 0.997, respectively, for the ESPRT method when the window size was set at 50 and 75 packets. The detection rate of ESPRT for the same dataset was 0.995 when the window size was set to 10 packets. The average accuracy for the DARPA 2000 dataset for ESPRT was 0.905, and the detection rate was 0.929. Finally, ESPRT was scalable to a multiple domain topology application.
Open AccessIdentification of Distributed Denial of Services Anomalies by Using Combination of Entropy and Sequential Probabilities Ratio Test Methods
One of the most dangerous kinds of attacks affecting computers is a distributed denial of services (DDoS) attack. The main goal of this attack is to bring the targeted machine down and make their services unavailable to legal users. This can be accomplished mainly by directing many machines to send a very large number of packets toward the specified machine to consume its resources and stop it from working. We implemented a method using Java based on entropy and sequential probabilities ratio test (ESPRT) methods to identify malicious flows and their switch interfaces that aid them in passing through. Entropy (E) is the first technique, and the sequential probabilities ratio test (SPRT) is the second technique. The entropy method alone compares its results with a certain threshold in order to make a decision. The accuracy and F-scores for entropy results thus changed when the threshold values changed. Using both entropy and SPRT removed the uncertainty associated with the entropy threshold. The false positive rate was also reduced when combining both techniques. Entropy-based detection methods divide incoming traffic into groups of traffic that have the same size. The size of these groups is determined by a parameter called window size. The Defense Advanced Research Projects Agency (DARPA) 1998, DARPA2000, and Canadian Institute for Cybersecurity (CIC-DDoS2019) databases were used to evaluate the implementation of this method. The metric of a confusion matrix was used to compare the ESPRT results with the results of other methods. The accuracy and f-scores for the DARPA 1998 dataset were 0.995 and 0.997, respectively, for the ESPRT method when the window size was set at 50 and 75 packets. The detection rate of ESPRT for the same dataset was 0.995 when the window size was set to 10 packets. The average accuracy for the DARPA 2000 dataset for ESPRT was 0.905, and the detection rate was 0.929. Finally, ESPRT was scalable to a multiple domain topology application.
- Open Access
- 17 October 2020
- Published by University of Slavonski Brod in Tehnicki vjesnik - Technical Gazette
- Vol. 27 (5) , 1478-1485
Simple and Efficient Transcutaneous Inductive Micro-System Device Based on ASK Modulation at 6.78 MHz ISM Band
This paper deals with designing a simple and efficient simultaneous inductive power and data transmission for transcutaneous Micro-system based on ASK modulation at 6,78 MHz industrial, scientific, and medical (ISM) band to avoid the...
- 17 October 2020
- Published by University of Slavonski Brod in Tehnicki vjesnik - Technical Gazette
- Vol. 27 (5) , 1478-1485
Open AccessSimple and Efficient Transcutaneous Inductive Micro-System Device Based on ASK Modulation at 6.78 MHz ISM Band
This paper deals with designing a simple and efficient simultaneous inductive power and data transmission for transcutaneous Micro-system based on ASK modulation at 6,78 MHz industrial, scientific, and medical (ISM) band to avoid the...