TITsubasa Ishikawa

Tsubasa Ishikawa

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tsubasa Ishikawa has a total of 43 co-authors. Here are the top co-authors by number of shared publications:

  • Tomoaki Tashima

    Department of Gastroenterology Saitama Medical University International Medical Center Saitama Japan

    5 shared publications
  • Shomei Ryozawa

    Department of Gastroenterology Saitama Medical University International Medical Center Saitama Japan

    3 shared publications
  • Shomei Ryozawa

    Department of Gastroenterology Saitama Medical University International Medical Center Saitama Japan

    3 shared publications
  • Tomonori Kawasaki

    Department of Pathology Saitama Medical University International Medical Center Saitama Japan

    3 shared publications
  • Jun Kato

    Department of Gastroenterology, Graduate School of Medicine Chiba University Chiba Japan

    2 shared publications
  • Jun‐Ichiro Ikeda

    Department of Diagnostic Pathology, Graduate School of Medicine Chiba University Chiba Japan

    2 shared publications

Latest Publications

  • Genetic Variation in Background Mucosa Across Different Grades of Chronic Esophagitis

    by Takuya Ohashi, Kenichiro Okimoto, Tatsuya Kaneko, Naoki Akizue, Yosuke Hirotsu, Kenji Amemiya, Akane Krosugi, Tsubasa Ishikawa, Yuki Ohta, Takashi Taida, et al.

    Background and Aim: The risk of cancer in chronic esophagitis varies by the number of Lugol's voiding lesions (LVLs). However, how these mutations differ by LVLs grade remains unclear. We aimed to clarify the genetic characteristics of the background mucosa by LVLs grade with a history of endoscopic treatment for esophageal squamous cell carcinoma (ESCC) or squamous dysplasia (SD). Methods: A total of 34 patients (28 ESCC, 6 SD) were classified by LVLs grade. Tissues from ESCC/SD and background mucosa were taken endoscopically, and DNA was extracted. Somatic mutations were identified in the esophageal cancer panel. For each mutation, putative drivers were identified by OncoKB, and the gene mutation patterns were compared among the grades. Results: There were LVLs grade B/C = 14/20 cases. Somatic mutation of TP53 was found significantly more frequently in the LVLs than in the background mucosa (88.2% vs. 64.7%, p = 0.043, Fisher's exact test). Somatic mutations of NOTCH1, including putative drivers, were more frequent in the background mucosa than in ESCC/SD (82.3% vs. 44.1%, p = 0.002, Fisher's exact test). There was no significant difference in the percentage of putative drivers of TP53 and NOTCH1 in the background mucosa by LVLs grade B/C (50.0% vs. 35.0%, p = 0.487; 7.1% vs. 5.0%, p = 1.000, Fisher's exact test). Conclusion: Regardless of LVLs grade, the background mucosa of patients with chronic esophagitis who already had ESCC or SD had already accumulated the same level of TP53 gene mutations. Even patients with LVLs grade B chronic esophagitis should undergo regular endoscopic examination for early detection of ESCC.

  • Open Access

    Usefulness of Endoscopic Mucosal Resection Using an Over‐the‐Scope Clip for Duodenal Neuroendocrine Tumors: A Multicenter Retrospective Comparative Study

    by Tomoaki Tashima, Osamu Dohi, Hideki Kobara, Tomonori Kawasaki, Hayato Fukui, Naoya Tada, Kunihisa Uchita, Satoshi Asai, Takashi Hirose, Takahiro Muramatsu, et al.

    Background and Aim: Resection of non‐ampullary duodenal neuroendocrine tumors presents technical challenges. This study investigated the efficacy and safety of endoscopic mucosal resection using an over‐the‐scope clip compared to endoscopic mucosal resection with a ligation device and endoscopic submucosal dissection.Methods: This retrospective multicenter study included 65 lesions (63 patients), categorized by resection method: endoscopic mucosal resection using an over‐the‐scope clip (n = 26), endoscopic mucosal resection using a ligation device (n = 17), and endoscopic submucosal dissection (n = 22). Patient characteristics, tumor details, and outcomes were systematically evaluated, with significance at p < 0.05.Results: Endoscopic mucosal resection using an over‐the‐scope clip had a significantly shorter procedure time than endoscopic submucosal dissection (16 min [7–30] vs. 60 min [28–119], p < 0.001) and recorded no perforations. Endoscopic mucosal resection using a ligation device was employed for smaller lesions, while endoscopic submucosal dissection had challenges in achieving clear margins. Hospitalization duration was the longest for the endoscopic submucosal dissection group (endoscopic mucosal resection using an over‐the‐scope clip: 4 [3–7] days, endoscopic mucosal resection using a ligation device: 5 [4–8] days, endoscopic submucosal dissection: 7 [4–15] days, p < 0.001). Endoscopic mucosal resection using an over‐the‐scope clip exhibited a unique advantage for full‐thickness resection.Conclusions: Endoscopic mucosal resection using an over‐the‐scope clip allows for full‐thickness resection with fewer complications. While effective, endoscopic mucosal resection using a ligation device is less reliable for achieving clear vertical margins, and endoscopic submucosal dissection, suitable for larger tumors, has a longer duration and higher complication rate.


  • Efficacy of Magnifying Texture and Color Enhancement Imaging With Indigo Carmine as an Alternative to Crystal Violet for Colorectal Tumors

    by Tsubasa Ishikawa, Kenichiro Okimoto, Tomoaki Matsumura, Naoki Akizue, Akane Kurosugi, Michiko Sonoda, Tatsuya Kaneko, Yuki Ohta, Takashi Taida, Keisuke Matsusaka, et al.

    Background: Pit pattern diagnosis using crystal violet staining for colorectal tumors is useful for qualitative and depth diagnosis. However, due to its reported carcinogenic potential, the use of crystal violet has been restricted. This study was aimed at investigating the efficacy of texture and color enhancement imaging (TXI) magnification in pit pattern diagnosis.Methods: This study enrolled consecutive patients with consent obtained and with colonic tumors indicated for magnifying endoscopy in which all modalities' images (magnified observation with crystal violet staining (CV), magnified white light observation with indigo carmine (IC‐WLI), and magnified TXI observation with indigo carmine (IC‐TXI)) were evaluable between July 2020 and January 2023. The visibility of the pit pattern using a 5‐point Likert scale and its diagnostic accuracy were compared (IC‐TXI vs. IC‐WLI, reference: CV, by three experts).Results: A total of 145 colorectal tumors from 145 patients were included. Visibility scores for the pit pattern were significantly higher with IC‐TXI compared to IC‐WLI (all three experts, p < 0.0001). The pit pattern match rate (Type II/III/IV/V) of IC‐TXI compared to CV was also superior to IC‐WLI (72.9% vs. 59.7%; p = 0.02).Conclusions: IC‐TXI provided reasonably good and higher visibility and diagnostic accuracy than IC‐WLI for pit pattern diagnosis of colorectal tumors compared to CV, suggesting it as an alternative to CV.


  • Open Access

    Red dichromatic imaging enhances submucosal visibility during endoscopic submucosal dissection: Pilot study

    by Tsubasa Ishikawa, Tomoaki Tashima, Tomonori Kawasaki, Kankei Fujimoto, Kei Sugimoto, Takahiro Shin, Takahiro Muramatsu, Yumi Mashimo, Shomei Ryozawa

    In 2020, Olympus Medical Systems Corporation introduced red dichromatic imaging (RDI) as a novel image-enhanced endoscopy (IEE) technology. However, clinical evidence regarding its practical applications and the lesions for which RDI is beneficial remains limited. Endoscopic submucosal dissection (ESD) is an essential therapeutic option for gastrointestinal tumors, yet achieving clear visualization of the dissecting layer remains a significant challenge. This study aimed to evaluate the efficacy of RDI in enhancing visualization of the dissecting layer during ESD.A total of 86 images from 43 gastrointestinal tumors (esophagus, stomach, duodenum, colon, and rectum) were evaluated by eight endoscopists. Visibility of the dissecting layer was assessed using a scale ranging from -2 (poor) to 2 (excellent) under white light imaging (WLI) and RDI. In addition, the color difference between the submucosal and muscular layers was analyzed using the International Commission on Illumination Lab color space system.RDI significantly improved visibility of the dissecting layer compared with WLI. Moreover, RDI showed a significantly greater color difference between the submucosal and muscular layers than WLI.RDI enhances visualization during ESD by improving visibility of the dissecting layer and increasing color differentiation compared with conventional WLI. These findings suggest that incorporating RDI into routine endoscopic practice could lead to more precise and efficient ESD procedures, ultimately improving patient outcomes.


  • Open Access

    Successful underwater endoscopic submucosal dissection with gel immersion for early gastric cancer in an upside-down stomach

    by Takahiro Muramatsu, Tomoaki Tashima, Tsubasa Ishikawa, Tomonori Kawasaki, Yumi Mashimo, Takao Itoi, Shomei Ryozawa

    An upside-down stomach (UDS) is a relatively rare type of esophageal hiatal hernia; almost the entire stomach prolapses into the posterior mediastinum in affected patients [1]. Surgical procedures for gastric cancer arising from a UDS have been reported [2]; however, no reports on endoscopic submucosal dissection (ESD) for early gastric cancer arising in a UDS are available. In patients with a UDS, endoscope maneuverability is poor because their stomachs are inverted. Recently, water or gel immersion has been reported to be useful for improving the field of view and scope maneuverability [3] [4] [5]. Herein, we describe underwater ESD with gel immersion performed successfully for early gastric cancer arising from a UDS ([Video 1]). An 85-year-old woman with a UDS ([Fig. 1] a,b) presented with early gastric cancer (lesion size 10 mm, type 0-IIc) located on the lesser curvature of the upper body ([Fig. 2] a,b). Approaching the lesion was difficult due to the UDS; thus, gas was removed from the lumen and replaced with water and gel (Viscoclear; Otsuka Pharmaceutical, Tokushima, Japan) to establish an underwater condition. The water–gel mixture maintained a lower intraluminal pressure and allowed us to approach the lesion, even from its distal side, under a clearer view ([Fig. 3] a–h). A mucosal incision was made on the distal side to mark the incision limit. This was followed by a proximal mucosal incision and a complete circumferential incision. Finally, submucosal dissection was continued, and a complete en bloc resection was performed ([Fig. 3] i–n). Additional gel was injected as needed to obtain a clear view of the submucosal layer. In conclusion, low-pressure endoscopy with water and gel immersion may help endoscopists overcome poor endoscope operability in procedures involving a UDS. This approach may further reduce the patient’s suffering, stabilize their condition, and enable safe resection of UDS lesions. Endoscopy_UCTN_Code_TTT_1AO_2AG_3AD Article published online: 14 March 2024 © 2024. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany


  • Endoscopic mucosal resection with over-the-scope clip (EMR-O) for colorectal tumors: A single-center case series

    by Takahiro Muramatsu, Tomoaki Tashima, Tsubasa Ishikawa, Yumi Mashimo, Shomei Ryozawa

    Background: We developed a new endoscopic resection method that combines endoscopic mucosal resection (EMR) with an over-the-scope clip (OTSC), termed EMR-O. In this study, we aimed to evaluate the short-term outcomes of EMR-O for colorectal tumors. Method: In total, 9 consecutive patients who underwent EMR-O from September 2017 and October 2022 were retrospectively enrolled. Patients' characteristics and treatment outcomes were evaluated. Result: The En bloc and R0 resection rates were 100% and 89%. The median resected specimen size was 16 (10-27) mm, with a median resected tumor size was 8 (5-17) mm. The median procedure time was 10 (7-15) min. There were no intraoperative or delayed perforation and postoperative bleeding. Discussion: Although EMR-O has limitations in target lesion size, it has the advantages of a short procedure time and the prevention of perforation.

  • Novel traction and mucosal defect closure methods using clip‐traction bands for duodenal endoscopic submucosal dissection

    by Tomoaki Tashima, Tsubasa Ishikawa, Shomei Ryozawa

    Watch a video of this article.