Edvaldo Faour Coutinho da Silva
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Edvaldo Faour Coutinho da Silva has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Catize Brandelero
Universidade Federal de Santa Maria (UFSM), Brasil
2 shared publications - Alexandre Russini
Universidade Federal de Santa Maria (UFSM), Brasil
1 shared publication - Christian dos Santos
Universidade Federal de Santa Maria (UFSM), Brasil
1 shared publication - Gilvan Moisés Bertollo
Universidade Federal de Santa Maria
1 shared publication - José Fernando Schlosser
Universidade Federal de Santa Maria (UFSM), Brasil
1 shared publication Mateus Cassol Cella
Mechanical Engineer Santa Maria
1 shared publication
Latest Publications
- Open Access
- 1 January 2026
- Published by FapUNIFESP (SciELO) in Ciência Rural
- Vol. 56 (9)
Acoustic characterization of an outdoor test environment for determining sound power levels of hand-held machines
Sound power is a fundamental parameter for characterizing noise sources. This report described the methodology applied to characterize an outdoor environment for determining the sound power levels of portable hand-held machines based on sound pressure measurements. To achieve this objective, the procedures followed ISO 3744:2010 and ABNT NBR ISO 22868:2023. In addition, measurements were performed using a Solo (01dB) sound level meter. The results show that background noise levels remained below the applicable correction limits for both frequency bands above 160 Hz and overall levels. The environmental correction factor was 1.7 dB(A). Sound power levels were 90.4 and 106.2 dB(A) for the chainsaw, and 85.2 and 104.7 dB(A) for the brush cutter, corresponding to idling and full-load conditions, respectively. Therefore, the negligible influence of background noise and an environmental correction factor below 2 dB(A) confirm the suitability of the test site and support the reliability of the sound power levels determined for the evaluated sources.
- 1 January 2026
- Published by FapUNIFESP (SciELO) in Ciência Rural
- Vol. 56 (9)
Open AccessAcoustic characterization of an outdoor test environment for determining sound power levels of hand-held machines
Sound power is a fundamental parameter for characterizing noise sources. This report described the methodology applied to characterize an outdoor environment for determining the sound power levels of portable hand-held machines based on sound pressure measurements. To achieve this objective, the procedures followed ISO 3744:2010 and ABNT NBR ISO 22868:2023. In addition, measurements were performed using a Solo (01dB) sound level meter. The results show that background noise levels remained below the applicable correction limits for both frequency bands above 160 Hz and overall levels. The environmental correction factor was 1.7 dB(A). Sound power levels were 90.4 and 106.2 dB(A) for the chainsaw, and 85.2 and 104.7 dB(A) for the brush cutter, corresponding to idling and full-load conditions, respectively. Therefore, the negligible influence of background noise and an environmental correction factor below 2 dB(A) confirm the suitability of the test site and support the reliability of the sound power levels determined for the evaluated sources.
- Open Access
- 5 September 2022
- Published by Revista Engenharia na Agricultura in REVISTA ENGENHARIA NA AGRICULTURA - REVENG
- Vol. 30, 294-302
Hand-arm vibration while operating a side brush cutter with three cutting implements in two crops
The use of side brushcutters exposes users to vibration and noise, which can cause damage to the operator, as they act as a stressor agent. Excessive vibration is responsible for countless disorders, including Raynaud’s syndrome. This study aimed to assess the effect of the vibrations of a side brush cutter on the human body. A side brush cutter was used with three cutting implements (double blade, triple blade and double nylon thread) applied to two crops (wheat and ryegrass). The vibration was measured through a three-dimensional accelerometer placed on the handgrips of the brush cutter, in compliance with the provisions of the ISO 5349-1 Standard. The analyzed variables were submitted to the Shapiro-Wilk and Bartlett tests. Due to the abnormality, the data were transformed by the Neperian logarithm and submitted to analysis of variance, and the means were compared by the Tukey test at 5% probability. As a result, the orthogonal y-axis presented a higher vibration level; the three-point blade showed the lowest vibration level compared to the other cutting implements for both crops; these vibration levels did not exceed the NHO10 recommendation. Hence, using the appropriate attachment for each operation may reduce the harm caused by vibration to the operator’s body.
- 5 September 2022
- Published by Revista Engenharia na Agricultura in REVISTA ENGENHARIA NA AGRICULTURA - REVENG
- Vol. 30, 294-302
Open AccessHand-arm vibration while operating a side brush cutter with three cutting implements in two crops
The use of side brushcutters exposes users to vibration and noise, which can cause damage to the operator, as they act as a stressor agent. Excessive vibration is responsible for countless disorders, including Raynaud’s syndrome. This study aimed to assess the effect of the vibrations of a side brush cutter on the human body. A side brush cutter was used with three cutting implements (double blade, triple blade and double nylon thread) applied to two crops (wheat and ryegrass). The vibration was measured through a three-dimensional accelerometer placed on the handgrips of the brush cutter, in compliance with the provisions of the ISO 5349-1 Standard. The analyzed variables were submitted to the Shapiro-Wilk and Bartlett tests. Due to the abnormality, the data were transformed by the Neperian logarithm and submitted to analysis of variance, and the means were compared by the Tukey test at 5% probability. As a result, the orthogonal y-axis presented a higher vibration level; the three-point blade showed the lowest vibration level compared to the other cutting implements for both crops; these vibration levels did not exceed the NHO10 recommendation. Hence, using the appropriate attachment for each operation may reduce the harm caused by vibration to the operator’s body.