Heloisa Pereira Sá Costa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Heloisa Pereira Sá Costa has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Melissa Gurgel Adeodato Vieira
University of Campinas - School of Chemical Engineering, Albert Einstein Av., 500, Campinas, SP, 13083-852, Brazil
5 shared publications - Emanuele Dutra Valente Duarte
School of Chemical Engineering, Universidade Estadual de Campinas, Albert Einstein Av, São Paulo, Brazil
4 shared publications - Meuris Gurgel Carlos da Silva
Department of Processes and Products Design, School of Chemical Engineering, University of Campinas (UNICAMP), Campinas, Brazil
4 shared publications - Mariana Gomes Oliveira
Department of Environmental and Sanitary Engineering Santa Catarina State University Lages Brazil
2 shared publications - Alexandre Filipe Porfírio Ferreira
LSRE-LCM, ALiCE, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal
1 shared publication - Flávio Vasconcelos da Silva
State University of Campinas
1 shared publication
Latest Publications
- Open Access
- 14 February 2026
- Published by Elsevier in Surfaces and Interfaces
- Vol. 86
Continuous adsorption and advanced oxidative degradation of pharmaceuticals pollutants using iron-modified MWCNT–Bentonite pellets
- 14 February 2026
- Published by Elsevier in Surfaces and Interfaces
- Vol. 86
Open AccessContinuous adsorption and advanced oxidative degradation of pharmaceuticals pollutants using iron-modified MWCNT–Bentonite pellets
- 13 June 2025
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 32 (26) , 15643-15656
Fixed-bed studies and artificial neural network modeling for removal of fluoroquinolone antibiotics using a green MWCNT@E adsorbent
Ciprofloxacin (CIP) and ofloxacin (OFL), commonly used fluoroquinolone antibiotics, have been frequently detected in water sources which can cause environmental toxicity. This study explored the application of carbon nanotubes (CNTs) functionalized using a green method in a continuous adsorption system for the removal of CIP and OFL by comparing traditional mass-transfer models and artificial neural networks (ANN). Results demonstrated that the system was more effective at low concentrations (0.2 mmol/L) and flow rates (0.2 mL/min), for both antibiotics, with extended breakthrough times, indicating that OFL (1256.39 min) and CIP (1314.60 min) were completely removed for a longer period, and the lowest mass transfer zone for OFL (2.75 cm) and CIP (3.44 cm). The mathematical models showed good fits to the acquired data, although the model developed by Yan et al. described the systems accurately (R2 > 0.99) under all tested conditions. ANN modeling showed accurate prediction of the fixed-bed dataset. The phytotoxicity study indicated a significant reduction in the toxicity of the effluent after treatment. Therefore, the green-functionalized CNTs exhibited prominent performance in a continuous system, offering a promising approach for scaling up wastewater treatment processes. Graphical abstract
- 13 June 2025
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 32 (26) , 15643-15656
Fixed-bed studies and artificial neural network modeling for removal of fluoroquinolone antibiotics using a green MWCNT@E adsorbent
Ciprofloxacin (CIP) and ofloxacin (OFL), commonly used fluoroquinolone antibiotics, have been frequently detected in water sources which can cause environmental toxicity. This study explored the application of carbon nanotubes (CNTs) functionalized using a green method in a continuous adsorption system for the removal of CIP and OFL by comparing traditional mass-transfer models and artificial neural networks (ANN). Results demonstrated that the system was more effective at low concentrations (0.2 mmol/L) and flow rates (0.2 mL/min), for both antibiotics, with extended breakthrough times, indicating that OFL (1256.39 min) and CIP (1314.60 min) were completely removed for a longer period, and the lowest mass transfer zone for OFL (2.75 cm) and CIP (3.44 cm). The mathematical models showed good fits to the acquired data, although the model developed by Yan et al. described the systems accurately (R2 > 0.99) under all tested conditions. ANN modeling showed accurate prediction of the fixed-bed dataset. The phytotoxicity study indicated a significant reduction in the toxicity of the effluent after treatment. Therefore, the green-functionalized CNTs exhibited prominent performance in a continuous system, offering a promising approach for scaling up wastewater treatment processes. Graphical abstract
- Open Access
- 21 November 2023
- Published by Universidade Estadual de Campinas
Aplicação do resíduo da extração sólido-líquido de alginato da alga Sargassum filipendula para bioadsorção de íons alumínio
- 21 November 2023
- Published by Universidade Estadual de Campinas
Open AccessAplicação do resíduo da extração sólido-líquido de alginato da alga Sargassum filipendula para bioadsorção de íons alumínio
- 5 September 2022
- Published by Elsevier in Journal of Cleaner Production
- Vol. 373
Green-functionalized carbon nanotubes as adsorbents for the removal of emerging contaminants from aqueous media
- 5 September 2022
- Published by Elsevier in Journal of Cleaner Production
- Vol. 373
Green-functionalized carbon nanotubes as adsorbents for the removal of emerging contaminants from aqueous media