Tarik El Ghalbzouri
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tarik El Ghalbzouri has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Jaafar EL Bakkali
ERSN Laboratory, University Abdelmalek Essaadi, Faculty of Sciences, Department of Physics, Tetouan, Morocco; Royal School of Military Health Service, Rabat, Morocco
5 shared publications - Randa Yerrou
Radiation and Nuclear Systems Laboratory ERSN, Faculty of Sciences, University Abdelmalek Essaadi, Tetouan, Morocco
3 shared publications - Tarek El Bardouni
ERSN Laboratory, Physics Department, Faculty of Sciences, University Abdelmalek Essaadi, Tetouan, Morocco
3 shared publications - Abdelhamid Nouayti
Radiation and Nuclear Systems Laboratory ERSN, Faculty of Sciences, University Abdelmalek Essaadi, Tetouan, Morocco
2 shared publications - Assia Arectout
Radiation and Nuclear Systems Laboratory ERSN, Faculty of Sciences, University Abdelmalek Essaadi, Tetouan, Morocco
2 shared publications - Hicham Satti
Radiation and Nuclear Systems Laboratory ERSN, Faculty of Sciences, University Abdelmalek Essaadi, Tetouan, Morocco
2 shared publications
Latest Publications
- Open Access
- 1 December 2026
- Published by KEAI Publishing in Nuclear Analysis
- Vol. 5 (4)
Integrated neutron backscattering–gamma scanning for diagnosing laboratory-scale unit column
- 1 December 2026
- Published by KEAI Publishing in Nuclear Analysis
- Vol. 5 (4)
Open AccessIntegrated neutron backscattering–gamma scanning for diagnosing laboratory-scale unit column
- 18 October 2025
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 19 (1) , 56-67
New estimation of S-coefficients for radionuclides C-11, N-13, O-15, and F-18 in male and female computational mesh-type phantom using DoseCalcs code
Accurate estimation of absorbed doses in organs/tissues is essential for effective internal dosimetry. This is especially the case for positron-emission tomography-utilized radiopharmaceuticals that contain positron-emitting radionuclides. To achieve this, it is essential to calculate S-coefficients (S), basic coefficients representing the absorbed dose in the target organ per unit of nuclear transformation in the source organ. In addition, as the evolution of computational phantoms from stylized, voxelized, to mesh-type models continues, updating the S-coefficients to correspond with the new phantom generation becomes required. We employed the DoseCalcs Monte Carlo platform to estimate S-coefficients for four positron-emitting radionuclides, namely, C-11, N-13, O-15, and F-18. Based on decay and energy data for emitted positrons that were obtained from ICRP Publication 107, the simulations involved 24 regions as internal radiation sources in the male and female mesh-type phantoms of the International Commission on Radiological Protection (ICRP). We calculated the S-coefficients for 25 radiosensitive target regions. The graphs of S-coefficients for all target\(\leftarrow\)source pairs exhibit similar trends for the four radionuclides. We compared the results with the OpenDose database, which calculated S-coefficients for voxelized phantoms. The comparison showed that the S-coefficients and the OpenDose voxelized values were very close for most target regions in the mesh-type phantoms. However, discrepancies were observed in specific cases, such as thyroid\(\leftarrow\)UBCs and liver\(\leftarrow\)HeW. These discrepancies arise primarily from the differences in organs/tissues locations and shapes, as well as the differences in material composition, which is distributed across the large inter-distance between the source and target, contributing to significant variations.- 18 October 2025
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 19 (1) , 56-67
New estimation of S-coefficients for radionuclides C-11, N-13, O-15, and F-18 in male and female computational mesh-type phantom using DoseCalcs code
Accurate estimation of absorbed doses in organs/tissues is essential for effective internal dosimetry. This is especially the case for positron-emission tomography-utilized radiopharmaceuticals that contain positron-emitting radionuclides. To achieve this, it is essential to calculate S-coefficients (S), basic coefficients representing the absorbed dose in the target organ per unit of nuclear transformation in the source organ. In addition, as the evolution of computational phantoms from stylized, voxelized, to mesh-type models continues, updating the S-coefficients to correspond with the new phantom generation becomes required. We employed the DoseCalcs Monte Carlo platform to estimate S-coefficients for four positron-emitting radionuclides, namely, C-11, N-13, O-15, and F-18. Based on decay and energy data for emitted positrons that were obtained from ICRP Publication 107, the simulations involved 24 regions as internal radiation sources in the male and female mesh-type phantoms of the International Commission on Radiological Protection (ICRP). We calculated the S-coefficients for 25 radiosensitive target regions. The graphs of S-coefficients for all target\(\leftarrow\)source pairs exhibit similar trends for the four radionuclides. We compared the results with the OpenDose database, which calculated S-coefficients for voxelized phantoms. The comparison showed that the S-coefficients and the OpenDose voxelized values were very close for most target regions in the mesh-type phantoms. However, discrepancies were observed in specific cases, such as thyroid\(\leftarrow\)UBCs and liver\(\leftarrow\)HeW. These discrepancies arise primarily from the differences in organs/tissues locations and shapes, as well as the differences in material composition, which is distributed across the large inter-distance between the source and target, contributing to significant variations.- 8 February 2025
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 218, 111705
Evaluation of 18F-FDG absorbed dose ratios in percent in adult and pediatric reference phantoms using DoseCalcs Monte Carlo platform
- 8 February 2025
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 218, 111705
Evaluation of 18F-FDG absorbed dose ratios in percent in adult and pediatric reference phantoms using DoseCalcs Monte Carlo platform
- 5 November 2024
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 48 (1) , 87-102
Re-evaluation of $^{18}$F-FDG absorbed and effective dose in adult and pediatric phantoms using DoseCalcs Monte Carlo platform: a validation studyPositron emission tomography (PET) using \(^{18}\)F-FDG is a well-known modality for the diagnosis of various diseases in patients of different ages, sexes, and states of health, which implies that internal radiation dosimetry is highly desired for different phantom anatomies. In this study, we validate "DoseCalcs," a new Monte Carlo platform that combines personalized internal dosimetry calculations with Monte Carlo simulations. To achieve that, we used the specific absorbed fraction (SAF) calculated by DoseCalcs and those from ICRP publication 133 to estimate the absorbed dose per injected activity (AD/IA) and effective dose per injected activity (ED/IA) for \(^{18}\)F-FDG. The investigation focused on various voxelized phantoms representing different age groups, including adult male and female, and pediatric phantoms of various ages, from newborn to 15 years old. Using the DoseCalcs Monte Carlo platform, we have simulated the emission of \(^{18}\)F-FDG positrons based on the energy spectrum provided in ICRP publication 107. The results demonstrated the impact of anatomical differences and different organ/tissue compositions on radiation absorption, with significant variations in the AD/IA across different phantoms. Interestingly, organs/tissues near the emission source showed higher AD/IA, highlighting the anatomical dependence on the phantom. When our results were compared to established reference data, especially from ICRP128, most organs/tissues had good agreement. Still, some cases have shown differences. This shows how important it is to use accurate radionuclide data and biokinetic modeling in internal dosimetry calculations. Furthermore, we compared AD/IA and ED/IA values calculated in newborns by DoseCalcs with those derived from alternative codes, MCNP and EGSnrc. While the results generally exhibited consistency, subtle variations underscored the influence of biokinetics modeling choices and computational methodologies. Overall, this research contributes valuable insights into the precision of internal dosimetry calculations using "DoseCalcs-Gui" by providing one platform for Monte Carlo simulation and personalized internal dosimetry in nuclear medicine. The DoseCalcs platform is free for research and available for download at www.github.com/TarikEl/DoseCalcs-Gui.- 5 November 2024
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 48 (1) , 87-102
Re-evaluation of $^{18}$F-FDG absorbed and effective dose in adult and pediatric phantoms using DoseCalcs Monte Carlo platform: a validation studyPositron emission tomography (PET) using \(^{18}\)F-FDG is a well-known modality for the diagnosis of various diseases in patients of different ages, sexes, and states of health, which implies that internal radiation dosimetry is highly desired for different phantom anatomies. In this study, we validate "DoseCalcs," a new Monte Carlo platform that combines personalized internal dosimetry calculations with Monte Carlo simulations. To achieve that, we used the specific absorbed fraction (SAF) calculated by DoseCalcs and those from ICRP publication 133 to estimate the absorbed dose per injected activity (AD/IA) and effective dose per injected activity (ED/IA) for \(^{18}\)F-FDG. The investigation focused on various voxelized phantoms representing different age groups, including adult male and female, and pediatric phantoms of various ages, from newborn to 15 years old. Using the DoseCalcs Monte Carlo platform, we have simulated the emission of \(^{18}\)F-FDG positrons based on the energy spectrum provided in ICRP publication 107. The results demonstrated the impact of anatomical differences and different organ/tissue compositions on radiation absorption, with significant variations in the AD/IA across different phantoms. Interestingly, organs/tissues near the emission source showed higher AD/IA, highlighting the anatomical dependence on the phantom. When our results were compared to established reference data, especially from ICRP128, most organs/tissues had good agreement. Still, some cases have shown differences. This shows how important it is to use accurate radionuclide data and biokinetic modeling in internal dosimetry calculations. Furthermore, we compared AD/IA and ED/IA values calculated in newborns by DoseCalcs with those derived from alternative codes, MCNP and EGSnrc. While the results generally exhibited consistency, subtle variations underscored the influence of biokinetics modeling choices and computational methodologies. Overall, this research contributes valuable insights into the precision of internal dosimetry calculations using "DoseCalcs-Gui" by providing one platform for Monte Carlo simulation and personalized internal dosimetry in nuclear medicine. The DoseCalcs platform is free for research and available for download at www.github.com/TarikEl/DoseCalcs-Gui.- 20 March 2023
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 46 (2) , 645-657
S-values estimation of positron-emitting radionuclides in the ICRP voxel-based adult male organs using a new Geant4-based code DoseCalcs: validation study
Identifying the organs and tissues at risk from internal radiation exposure caused by radiopharmaceuticals requires determining the absorbed dose. The absorbed dose for radiopharmaceuticals is calculated by multiplying cumulated activity in source organs by the S-value, a crucial quantity that connects the energy deposited in the target organ and the emitting source one. It is defined as the ratio of absorbed energy in the target organ per unit of mass and unit of nuclear transition in the source organ. In this study, we used a new Geant4-based code called DoseCalcs to estimate the S-values for four positron-emitting radionuclides (\(^{11}\)C, \(^{13}\)N, \(^{15}\)O, and \(^{18}\)F) using decay and energy data from International Commission on Radiological Protection (ICRP) Publication 107. Twenty-three regions were simulated as radiation sources in the ICRP voxelized adult model developed in ICRP Publication 110. The Livermore physics packages were tailored to radionuclide photon mono-energy and \(\beta\)-mean energy. The estimated S-values based on \(\beta\)-mean energy show good agreement with those in the OpenDose data whose values were calculated using the full \(\beta\) spectrum. The results provide new S-values data for selected source regions; hence, they could be used for comparison and adult-patient dose estimation.- 20 March 2023
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 46 (2) , 645-657
S-values estimation of positron-emitting radionuclides in the ICRP voxel-based adult male organs using a new Geant4-based code DoseCalcs: validation study
Identifying the organs and tissues at risk from internal radiation exposure caused by radiopharmaceuticals requires determining the absorbed dose. The absorbed dose for radiopharmaceuticals is calculated by multiplying cumulated activity in source organs by the S-value, a crucial quantity that connects the energy deposited in the target organ and the emitting source one. It is defined as the ratio of absorbed energy in the target organ per unit of mass and unit of nuclear transition in the source organ. In this study, we used a new Geant4-based code called DoseCalcs to estimate the S-values for four positron-emitting radionuclides (\(^{11}\)C, \(^{13}\)N, \(^{15}\)O, and \(^{18}\)F) using decay and energy data from International Commission on Radiological Protection (ICRP) Publication 107. Twenty-three regions were simulated as radiation sources in the ICRP voxelized adult model developed in ICRP Publication 110. The Livermore physics packages were tailored to radionuclide photon mono-energy and \(\beta\)-mean energy. The estimated S-values based on \(\beta\)-mean energy show good agreement with those in the OpenDose data whose values were calculated using the full \(\beta\) spectrum. The results provide new S-values data for selected source regions; hence, they could be used for comparison and adult-patient dose estimation.- 14 March 2023
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 16 (2) , 212-226
Validation of the DoseCalcs Monte Carlo code for estimating the 18F S-values for ICRP adult and 15-year-old male and female phantoms
Internal radiation exposure using radiopharmaceuticals, as in nuclear medicine procedures, necessitates the estimation of the S-value to determine and improve the estimates of absorbed doses in at-risk organs and tissues. The S value is defined as the absorbed dose in the target organ per unit of nuclear transformation in the source organ. It is calculated using the specific absorbed fraction, which is an important quantity that connects the deposited energy in the target and emitting source organs. In this study, we applied DoseCalcs, a new Geant4-based tool, to estimate the S values of \(^{18}\)F using nuclear data from ICRP Publication 107. Geometrical data from ICRP Publications 110 and 143 were used to select four models representing male and female phantoms for adults and 15 years old to study the variability in the S-values arising from variations in anatomy and initial energy validations, because we used the \(\beta\) mean energy instead of the full beta spectrum. The \(^{18}\)F-released photons and \(\beta\) from 26 source organs were tracked using the Geant4 Livermore package. Accordingly, the S-values were calculated for 141 target organs. The results for the adult male and female phantoms were compared with the OpenDose reference data. These results agreed well with OpenDose, the average ratio for self-absorption S-values was 1.015, and the average ratios for the cross-irradiation were 1.2 and 1.22 for the AM and AF, respectively. This indicates the accuracy of DoseCalcs for subsequent use in estimating \(^{18}\)F S-values using voxelized geometries.- 14 March 2023
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 16 (2) , 212-226
Validation of the DoseCalcs Monte Carlo code for estimating the 18F S-values for ICRP adult and 15-year-old male and female phantoms
Internal radiation exposure using radiopharmaceuticals, as in nuclear medicine procedures, necessitates the estimation of the S-value to determine and improve the estimates of absorbed doses in at-risk organs and tissues. The S value is defined as the absorbed dose in the target organ per unit of nuclear transformation in the source organ. It is calculated using the specific absorbed fraction, which is an important quantity that connects the deposited energy in the target and emitting source organs. In this study, we applied DoseCalcs, a new Geant4-based tool, to estimate the S values of \(^{18}\)F using nuclear data from ICRP Publication 107. Geometrical data from ICRP Publications 110 and 143 were used to select four models representing male and female phantoms for adults and 15 years old to study the variability in the S-values arising from variations in anatomy and initial energy validations, because we used the \(\beta\) mean energy instead of the full beta spectrum. The \(^{18}\)F-released photons and \(\beta\) from 26 source organs were tracked using the Geant4 Livermore package. Accordingly, the S-values were calculated for 141 target organs. The results for the adult male and female phantoms were compared with the OpenDose reference data. These results agreed well with OpenDose, the average ratio for self-absorption S-values was 1.015, and the average ratios for the cross-irradiation were 1.2 and 1.22 for the AM and AF, respectively. This indicates the accuracy of DoseCalcs for subsequent use in estimating \(^{18}\)F S-values using voxelized geometries.- 6 September 2022
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 15 (4) , 323-339
Photon-specific absorbed fraction estimates in stylized ORNL and voxelized ICRP adult male phantoms using a new developed Geant4-based code “DoseCalcs”: a validation study
When a radiotracer is injected into a patient’s body as part of a nuclear medicine investigation, the entire body is exposed to the ionizing radiation emitted, which can cause biological damage. Therefore, it is important to predict the internal radiation dose to properly balance the advantages of radiological examinations. Currently, various Monte Carlo tools, such as MCNP, Geant4, and GATE, are available to estimate internal radiation dosimetry-related quantities, such as S values (S) and specific absorbed fractions (SAF). Such codes make physics easier for physicists who are experienced with computer programming; however, programming and/or simulation inputs remain a time-consuming and intensive task. In this study, we present a newly developed Geant4-based code for internal dosimetry calculations, namely “DoseCalcs”. To assess the performance of the geometrical methods and computational capabilities of our developed tool, we used the GDML, TEXT, STL, and C++ methods to model the ORNL adult phantom, and a voxel-based structure to construct the ICRP adult male. SAFs in the ORNL and ICRP adult male phantoms for eight discrete mono-energetic photons with energies ranging from 0.01 to 2 MeV are calculated with DoseCalcs and compared to ORNL and OpenDose reference data. The two phantoms showed good agreement with both references, which indicates the accuracy of DoseCalcs for subsequent use in estimating internal dosimetry quantities using a variety of geometrical methods.
- 6 September 2022
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 15 (4) , 323-339
Photon-specific absorbed fraction estimates in stylized ORNL and voxelized ICRP adult male phantoms using a new developed Geant4-based code “DoseCalcs”: a validation study
When a radiotracer is injected into a patient’s body as part of a nuclear medicine investigation, the entire body is exposed to the ionizing radiation emitted, which can cause biological damage. Therefore, it is important to predict the internal radiation dose to properly balance the advantages of radiological examinations. Currently, various Monte Carlo tools, such as MCNP, Geant4, and GATE, are available to estimate internal radiation dosimetry-related quantities, such as S values (S) and specific absorbed fractions (SAF). Such codes make physics easier for physicists who are experienced with computer programming; however, programming and/or simulation inputs remain a time-consuming and intensive task. In this study, we present a newly developed Geant4-based code for internal dosimetry calculations, namely “DoseCalcs”. To assess the performance of the geometrical methods and computational capabilities of our developed tool, we used the GDML, TEXT, STL, and C++ methods to model the ORNL adult phantom, and a voxel-based structure to construct the ICRP adult male. SAFs in the ORNL and ICRP adult male phantoms for eight discrete mono-energetic photons with energies ranging from 0.01 to 2 MeV are calculated with DoseCalcs and compared to ORNL and OpenDose reference data. The two phantoms showed good agreement with both references, which indicates the accuracy of DoseCalcs for subsequent use in estimating internal dosimetry quantities using a variety of geometrical methods.