Alexis Papadopoulos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Alexis Papadopoulos has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Dimitris Emfietzoglou
University of Ioannina
5 shared publications - Ioanna Kyriakou
University of Ioannina
5 shared publications - Sebastien Incerti
Université de Bordeaux
4 shared publications - Ioannis A. Daglis
Department of Physics, National and Kapodistrian University of Athens, Athens, Greece
3 shared publications - Wei Bo Li
Institute of Radiation Medicine, Helmholtz Zentrum München, German Research Center for Environmental Health, Neuherberg, Germany
3 shared publications - Yusuke Matsuya
Hokkaido University
3 shared publications
Latest Publications
- Open Access
- 25 March 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (8)
Intercomparison of low-energy electron transport calculations by different Monte Carlo track-structure simulation codes
Objective. To evaluate the uncertainty of physical features of low-energy electron transport in liquid water due to the use of different Monte Carlo track-structure (MCTS) codes. Approach. Five MCTS codes developed specifically for liquid water, namely, Geant4-DNA, PHITS-TS, RITRACKS, NASIC, and PARTRAC are compared and used to calculate the electronic stopping power, pathlength and absorption range, dose-point-kernel, and the frequency-mean (y ̅_F) and dose-mean (y ̅_D) lineal energy for primary electron energies from 20 eV to 100 keV. The uncertainty of each calculated quantity is evaluated by the relative standard deviation (RSD) and the maximum relative difference (MRD) among the codes. The medium-to-high-energy (1‒100 keV) performance of the codes is benchmarked against the stopping power and range data for liquid water reported in ICRU Report 90. Main Results. For energies above ~1 keV the RSD is moderate and mostly between 5–15%, but increases rapidly at lower energies, reaching 20–100% at sub-100 eV energies. It is noteworthy that the MRD may well exceed 100% below 100 eV, while remaining sizeable (>20%) even at relatively high energies (10–100 keV). Fairly good agreement between the MCTS codes and the ICRU data for the stopping power (1‒100 keV) and range (10‒100 keV) in liquid water is found with average deviations between 1‒16%, depending on the code. Significance: The present work reveals significant differences for low-energy electron transport among liquid water MCTS codes, especially below 100 eV. These differences potentially compromise the accuracy of nanoscale simulations where such electrons play a key role. The observed dispersion of results is a consequence of the limitations of the theoretical models used to calculate electron interaction cross sections and the lack of relevant experimental data for their validation and benchmarking. This highlights the need for further development of the physics models used in MCTS codes to reduce the uncertainties associated with low-energy electron transport calculations in liquid water.
- 25 March 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (8)
Open AccessIntercomparison of low-energy electron transport calculations by different Monte Carlo track-structure simulation codes
Objective. To evaluate the uncertainty of physical features of low-energy electron transport in liquid water due to the use of different Monte Carlo track-structure (MCTS) codes. Approach. Five MCTS codes developed specifically for liquid water, namely, Geant4-DNA, PHITS-TS, RITRACKS, NASIC, and PARTRAC are compared and used to calculate the electronic stopping power, pathlength and absorption range, dose-point-kernel, and the frequency-mean (y ̅_F) and dose-mean (y ̅_D) lineal energy for primary electron energies from 20 eV to 100 keV. The uncertainty of each calculated quantity is evaluated by the relative standard deviation (RSD) and the maximum relative difference (MRD) among the codes. The medium-to-high-energy (1‒100 keV) performance of the codes is benchmarked against the stopping power and range data for liquid water reported in ICRU Report 90. Main Results. For energies above ~1 keV the RSD is moderate and mostly between 5–15%, but increases rapidly at lower energies, reaching 20–100% at sub-100 eV energies. It is noteworthy that the MRD may well exceed 100% below 100 eV, while remaining sizeable (>20%) even at relatively high energies (10–100 keV). Fairly good agreement between the MCTS codes and the ICRU data for the stopping power (1‒100 keV) and range (10‒100 keV) in liquid water is found with average deviations between 1‒16%, depending on the code. Significance: The present work reveals significant differences for low-energy electron transport among liquid water MCTS codes, especially below 100 eV. These differences potentially compromise the accuracy of nanoscale simulations where such electrons play a key role. The observed dispersion of results is a consequence of the limitations of the theoretical models used to calculate electron interaction cross sections and the lack of relevant experimental data for their validation and benchmarking. This highlights the need for further development of the physics models used in MCTS codes to reduce the uncertainties associated with low-energy electron transport calculations in liquid water.
- Open Access
- 10 February 2025
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 64 (1) , 117-135
Analytic and Monte Carlo calculations of dose-mean lineal energy for 1 MeV–1 GeV protons with application to radiation protection quality factor
Radiation quality for determining biological effects is commonly linked to the microdosimetric quantity lineal energy ( $$y$$ ) and to the dose-mean lineal energy ( $${y}_{\text{D}}$$ ). Calculations of $${y}_{\text{D}}$$ are typically performed by specialised Monte Carlo track-structure (MCTS) codes, which can be time-intensive. Thus, microdosimetry-based analytic models are potentially useful for practical calculations. Analytic model calculations of proton $${y}_{\text{D}}$$ and radiation protection quality factor ( $$Q$$ ) values in sub-micron liquid water spheres (diameter 10–1000 nm) over a broad energy range (1 MeV–1 GeV) are compared against MCTS simulations by PHITS, RITRACKS, and Geant4-DNA. Additionally, an improved analytic microdosimetry model is proposed. The original analytic model of Xapsos is refined and model parameters are updated based on Geant4-DNA physics model. Direct proton energy deposition is described by an alternative energy-loss straggling distribution and the contribution of secondary electrons is calculated using the dielectric formulation of the relativistic Born approximation. MCTS simulations of proton $${y}_{\text{D}}$$ values using the latest versions of the PHITS, RITRACKS, and Geant4-DNA are reported along with the Monte Carlo Damage Simulation (MCDS) algorithm. The $${y}_{\text{D}}$$ datasets are then used within the Theory of Dual Radiation Action (TDRA) to illustrate variations in $$Q$$ with proton energy. By a careful selection of parameters, overall differences at the ~ 10% level between the proposed analytic model and the MCTS codes can be attained, significantly improving upon existing models. MCDS estimates of $${y}_{\text{D}}$$ are generally much lower than estimates from MCTS simulations. The differences of $$Q$$ among the examined methods are somewhat smaller than those of $${y}_{\text{D}}$$ . Still, estimates of proton $$Q$$ values by the present model are in better agreement with MCTS-based estimates than the existing analytic models. An improved microdosimetry-based analytic model is presented for calculating proton $${y}_{\text{D}}$$ values over a broad range of proton energies (1 MeV–1 GeV) and target sizes (10–1000 nm) in very good agreement with state-of-the-art MCTS simulations. It is envisioned that the proposed model might be used as an alternative to CPU-intensive MCTS simulations and advance practical microdosimetry and quality factor calculations in medical, accelerator, and space radiation applications.- 10 February 2025
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 64 (1) , 117-135
Open AccessAnalytic and Monte Carlo calculations of dose-mean lineal energy for 1 MeV–1 GeV protons with application to radiation protection quality factor
Radiation quality for determining biological effects is commonly linked to the microdosimetric quantity lineal energy ( $$y$$ ) and to the dose-mean lineal energy ( $${y}_{\text{D}}$$ ). Calculations of $${y}_{\text{D}}$$ are typically performed by specialised Monte Carlo track-structure (MCTS) codes, which can be time-intensive. Thus, microdosimetry-based analytic models are potentially useful for practical calculations. Analytic model calculations of proton $${y}_{\text{D}}$$ and radiation protection quality factor ( $$Q$$ ) values in sub-micron liquid water spheres (diameter 10–1000 nm) over a broad energy range (1 MeV–1 GeV) are compared against MCTS simulations by PHITS, RITRACKS, and Geant4-DNA. Additionally, an improved analytic microdosimetry model is proposed. The original analytic model of Xapsos is refined and model parameters are updated based on Geant4-DNA physics model. Direct proton energy deposition is described by an alternative energy-loss straggling distribution and the contribution of secondary electrons is calculated using the dielectric formulation of the relativistic Born approximation. MCTS simulations of proton $${y}_{\text{D}}$$ values using the latest versions of the PHITS, RITRACKS, and Geant4-DNA are reported along with the Monte Carlo Damage Simulation (MCDS) algorithm. The $${y}_{\text{D}}$$ datasets are then used within the Theory of Dual Radiation Action (TDRA) to illustrate variations in $$Q$$ with proton energy. By a careful selection of parameters, overall differences at the ~ 10% level between the proposed analytic model and the MCTS codes can be attained, significantly improving upon existing models. MCDS estimates of $${y}_{\text{D}}$$ are generally much lower than estimates from MCTS simulations. The differences of $$Q$$ among the examined methods are somewhat smaller than those of $${y}_{\text{D}}$$ . Still, estimates of proton $$Q$$ values by the present model are in better agreement with MCTS-based estimates than the existing analytic models. An improved microdosimetry-based analytic model is presented for calculating proton $${y}_{\text{D}}$$ values over a broad range of proton energies (1 MeV–1 GeV) and target sizes (10–1000 nm) in very good agreement with state-of-the-art MCTS simulations. It is envisioned that the proposed model might be used as an alternative to CPU-intensive MCTS simulations and advance practical microdosimetry and quality factor calculations in medical, accelerator, and space radiation applications. - Open Access
- 20 December 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (24) , 11981
Relative Biological Effectiveness (RBE) of Monoenergetic Protons: Comparison of Empirical and Biophysical Models
A constant proton relative biological effectiveness (RBE) of 1.1 for tumor control is currently used in proton therapy treatment planning. However, in vitro, in vivo and clinical experiences indicate that proton RBE varies with kinetic energy and, therefore, tissue depth within proton Bragg peaks. A number of published RBE models capture variations in proton RBE with depth. The published models can be sub-divided into empirical (or phenomenological) and biophysical (or mechanistic-inspired) RBE models. Empirical RBE models usually characterize the beam quality through the dose-averaged linear energy transfer (), while most biophysical RBE models relate RBE to the dose-averaged lineal energy (). In this work, an analytic microdosimetry model and the Monte Carlo damage simulation code (MCDS) were utilized for the evaluation of the and of monoenergetic proton beams in the clinically relevant energy range of 1–250 MeV. The calculated and values were then used for the estimation of the RBE for five different cell types at three dose levels (2 Gy, 5 Gy and 7 Gy). Comparisons are made between nine empirical RBE models and two biophysical models, namely, the theory of dual radiation action (TDRA) and the microdosimetric kinetic model (MKM). The results show that, at conventional dose fractions (~2 Gy) and for proton energies which correspond to the proximal and central regions of the spread-out Bragg peak (SOBP), RBE varies from 1.0 to 1.2. At lower proton energies related to the distal SOBP, we find significant deviations from a constant of 1.1, especially for late-responding tissues (low of ~1.5–3.5 Gy) where proton RBE may reach 1.3 to 1.5. For hypofractionated dose fractions (5–7 Gy), deviations from a constant of 1.1 are smaller, but may still be sizeable, yielding RBE values between 1.15 and 1.3. However, large discrepancies among the different models were observed that make the selection of a variable RBE across the SOBP uncertain.- 20 December 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (24) , 11981
Open AccessRelative Biological Effectiveness (RBE) of Monoenergetic Protons: Comparison of Empirical and Biophysical Models
A constant proton relative biological effectiveness (RBE) of 1.1 for tumor control is currently used in proton therapy treatment planning. However, in vitro, in vivo and clinical experiences indicate that proton RBE varies with kinetic energy and, therefore, tissue depth within proton Bragg peaks. A number of published RBE models capture variations in proton RBE with depth. The published models can be sub-divided into empirical (or phenomenological) and biophysical (or mechanistic-inspired) RBE models. Empirical RBE models usually characterize the beam quality through the dose-averaged linear energy transfer (), while most biophysical RBE models relate RBE to the dose-averaged lineal energy (). In this work, an analytic microdosimetry model and the Monte Carlo damage simulation code (MCDS) were utilized for the evaluation of the and of monoenergetic proton beams in the clinically relevant energy range of 1–250 MeV. The calculated and values were then used for the estimation of the RBE for five different cell types at three dose levels (2 Gy, 5 Gy and 7 Gy). Comparisons are made between nine empirical RBE models and two biophysical models, namely, the theory of dual radiation action (TDRA) and the microdosimetric kinetic model (MKM). The results show that, at conventional dose fractions (~2 Gy) and for proton energies which correspond to the proximal and central regions of the spread-out Bragg peak (SOBP), RBE varies from 1.0 to 1.2. At lower proton energies related to the distal SOBP, we find significant deviations from a constant of 1.1, especially for late-responding tissues (low of ~1.5–3.5 Gy) where proton RBE may reach 1.3 to 1.5. For hypofractionated dose fractions (5–7 Gy), deviations from a constant of 1.1 are smaller, but may still be sizeable, yielding RBE values between 1.15 and 1.3. However, large discrepancies among the different models were observed that make the selection of a variable RBE across the SOBP uncertain. - Open Access
- 16 April 2023
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 62 (2) , 221-234
Space radiation quality factor for Galactic Cosmic Rays and typical space mission scenarios using a microdosimetric approach
Space radiation exposure from omnipresent Galactic Cosmic Rays (GCRs) in interplanetary space poses a serious carcinogenic risk to astronauts due to the—limited or absent—protective effect of the Earth’s magnetosphere and, in particular, the terrestrial atmosphere. The radiation risk is directly influenced by the quality of the radiation, i.e., its pattern of energy deposition at the micron/DNA scale. For stochastic biological effects, radiation quality is described by the quality factor, $$Q$$ , which can be defined as a function of Linear Energy Transfer (LET) or the microdosimetric lineal energy ( $$y$$ ). In the present work, the average $$Q$$ of GCR for different mission scenarios was calculated using a modified version of the microdosimetric Theory of Dual Radiation Action (TDRA). NASA’s OLTARIS platform was utilized to generate the radiation environment behind different aluminum shielding (0–30 g/cm2) for a typical mission scenario in low-earth orbit (LEO) and in deep space. The microdosimetric lineal energy spectra of ions ( $$Z\ge 1$$ ) in 1 μm liquid water spheres were calculated by a generalized analytical model which considers energy-loss fluctuations and δ-ray transport inside the irradiated medium. The present TDRA-based $$Q$$ -values for the LEO and deep space missions were found to differ by up to 10% and 14% from the corresponding ICRP-based $$Q$$ -values and up to 3% and 6% from NASA’s $$Q$$ -model. In addition, they were found to be in good agreement with the $$Q$$ -values measured in the International Space Station (ISS) and by the Mars Science Laboratory (MSL) Radiation Assessment Detector (RAD) which represent, respectively, a LEO and deep space orbit.- 16 April 2023
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 62 (2) , 221-234
Open AccessSpace radiation quality factor for Galactic Cosmic Rays and typical space mission scenarios using a microdosimetric approach
Space radiation exposure from omnipresent Galactic Cosmic Rays (GCRs) in interplanetary space poses a serious carcinogenic risk to astronauts due to the—limited or absent—protective effect of the Earth’s magnetosphere and, in particular, the terrestrial atmosphere. The radiation risk is directly influenced by the quality of the radiation, i.e., its pattern of energy deposition at the micron/DNA scale. For stochastic biological effects, radiation quality is described by the quality factor, $$Q$$ , which can be defined as a function of Linear Energy Transfer (LET) or the microdosimetric lineal energy ( $$y$$ ). In the present work, the average $$Q$$ of GCR for different mission scenarios was calculated using a modified version of the microdosimetric Theory of Dual Radiation Action (TDRA). NASA’s OLTARIS platform was utilized to generate the radiation environment behind different aluminum shielding (0–30 g/cm2) for a typical mission scenario in low-earth orbit (LEO) and in deep space. The microdosimetric lineal energy spectra of ions ( $$Z\ge 1$$ ) in 1 μm liquid water spheres were calculated by a generalized analytical model which considers energy-loss fluctuations and δ-ray transport inside the irradiated medium. The present TDRA-based $$Q$$ -values for the LEO and deep space missions were found to differ by up to 10% and 14% from the corresponding ICRP-based $$Q$$ -values and up to 3% and 6% from NASA’s $$Q$$ -model. In addition, they were found to be in good agreement with the $$Q$$ -values measured in the International Space Station (ISS) and by the Mars Science Laboratory (MSL) Radiation Assessment Detector (RAD) which represent, respectively, a LEO and deep space orbit. - Open Access
- 6 September 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (18) , 8950
Microdosimetry Study of Proton Quality Factor Using Analytic Model Calculations
The quality factor (Q) is formally linked to the stochastic (e.g., carcinogenic) risk of diverse ionizing radiations at low doses and/or low dose rates. Q can be a function of the non-stochastic physical quantity Linear Energy Transfer (LET) or the microdosimetric parameter lineal energy (y). These two physical quantities can be calculated either by Monte Carlo (MC) track-structure simulations or by analytic models. In this work, various generalized analytical models were utilized and combined to determine the proton lineal energy spectra in liquid water spheres of various sizes (i.e., 10–3000 nm diameter) over the proton energy range of 1–250 MeV. The calculated spectra were subsequently used within the Theory of Dual Radiation Action (TDRA) and the ICRU Report 40 microdosimetric methodologies to determine the variation of with proton energy. The results revealed that the LET-based Q values underestimated the microdosimetric-based values for protons with energy below ~100 MeV. At energies relevant to the Bragg peak region (<20–30 MeV), the differences were larger than 20–50%, while reaching 200–500% at ~5 MeV. It was further shown that the microdosimetric-based values for protons below ~100 MeV were sensitive to the sphere size. Finally, condensed-phase effects had a very small (<5%) influence on the calculated microdosimetric-based over the proton energy range considered here.- 6 September 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (18) , 8950
Open AccessMicrodosimetry Study of Proton Quality Factor Using Analytic Model Calculations
The quality factor (Q) is formally linked to the stochastic (e.g., carcinogenic) risk of diverse ionizing radiations at low doses and/or low dose rates. Q can be a function of the non-stochastic physical quantity Linear Energy Transfer (LET) or the microdosimetric parameter lineal energy (y). These two physical quantities can be calculated either by Monte Carlo (MC) track-structure simulations or by analytic models. In this work, various generalized analytical models were utilized and combined to determine the proton lineal energy spectra in liquid water spheres of various sizes (i.e., 10–3000 nm diameter) over the proton energy range of 1–250 MeV. The calculated spectra were subsequently used within the Theory of Dual Radiation Action (TDRA) and the ICRU Report 40 microdosimetric methodologies to determine the variation of with proton energy. The results revealed that the LET-based Q values underestimated the microdosimetric-based values for protons with energy below ~100 MeV. At energies relevant to the Bragg peak region (<20–30 MeV), the differences were larger than 20–50%, while reaching 200–500% at ~5 MeV. It was further shown that the microdosimetric-based values for protons below ~100 MeV were sensitive to the sphere size. Finally, condensed-phase effects had a very small (<5%) influence on the calculated microdosimetric-based over the proton energy range considered here.