JHJinmei He

Jinmei He

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jinmei He has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    CD34 Antibody-Coated Biodegradable Fiber Membrane Effectively Corrects Atrial Septal Defect (ASD) by Promoting Endothelialization

    by Bin Chu, Xiaoli Li, Shiqiang Fan, Jinmei He, Xiaohong Ge, Hui Li, Changsheng Chen, Zhen Wang, Song Wang, Boning Li

    Biodegradable materials are a next-generation invention for the treatment of congenital heart diseases. However, the corresponding technology used to develop ideal biomaterials still presents challenges. We previously reported the first biodegradable atrial septal defect (ASD) occluder made of poly-lactic acid (PLLA). Unfortunately, the PLLA occluder had a limited endothelialization effect. In this study, the surface of the occluder membrane was coated with sericin/CD34 antibodies to promote the growth of endothelial cells and the regeneration of defective tissue and enhance the repair of the atrial septal defect. The physicochemical properties of the coat on the surface of the fiber membrane were characterized. The sericin coat successfully covered the fiber surface of the membrane, and the thickness of the membrane increased with the sericin concentration. The swelling rate reached 230%. The microscopic observation of fluorescently labeled CD34 antibodies showed that the antibodies successfully attached to the fiber membrane; the fluorescence intensity of PLLA-SH5 was particularly high. The in vitro experiment showed that the PLLA-SH-CD34 fiber membrane was biocompatible and promoted the adhesion and proliferation of endothelial cells. According to our findings, the PLLA-SH-CD34 membrane provides a theoretical and technical basis for the research and development of novel biodegradable occluders.


  • Open Access

    Obtaining a Reliable Diagnostic Biomarker for Diabetes Mellitus by Standardizing Salivary Glucose Measurements

    by Yangyang Cui, Hankun Zhang, Song Wang, Junzhe Lu, Jinmei He, Lanlan Liu, Weiqiang Liu

    Salivary glucose is frequently utilized in diabetes mellitus (DM), and it might be proposed as a potential biomarker candidate for DM, as it is non-invasive and cost-effective and achieves adequate diagnostic performance for DM patients. However, salivary glucose levels may change under specific conditions. It is consequently essential to maintain a consistent strategy for measuring saliva, taking into account the possibility of external factors influencing salivary glucose levels. In this study, we analyzed salivary glucose levels under different handling conditions and donor-dependent factors, including age, interdiurnal variations, and collection and processing methods. A structured questionnaire was used to determine the symptoms and predisposing factors of DM. The glucose oxidase peroxidase method was used to estimate glucose levels in the blood and saliva of people in a fasting state. The aim of this study is to investigate the effect of such conditions on salivary glucose levels. We found that these extraneous variables should be taken into account in the future when salivary glucose is used as a predictive biomarker for DM.


  • Open Access

    Stimulated Parotid Saliva Is a Better Method for Depression Prediction

    by Yangyang Cui, Hankun Zhang, Song Wang, Junzhe Lu, Jinmei He, Lanlan Liu, Weiqiang Liu

    Background: Saliva cortisol is considered to be a biomarker of depression prediction. However, saliva collection methods can affect the saliva cortisol level. Objective: This study aims to determine the ideal saliva collection method and explore the application value of saliva cortisol in depression prediction. Methods: 30 depressed patients and 30 healthy controls were instructed to collect saliva samples in the morning with six collection methods. Simultaneous venous blood was collected. Enzyme-linked immunosorbent assay was used to determine the cortisol level. The 24-observerrated Hamilton depression rating scale (HAMD-24) was used to assess the severity of depression. Results: The significant differences in saliva cortisol levels depend on the saliva collection methods. The level of unstimulated whole saliva cortisol was most correlated with blood (r = 0.91). The stimulated parotid saliva cortisol can better predict depression. The area under the curve was 0.89. In addition, the saliva cortisol level of the depression patients was significantly higher than the healthy controls. The correlation between the cortisol level and the HAMD-24 score was highly significant. The higher the saliva cortisol level, the higher the HAMD-24 score. Conclusions: All the above findings point to an exciting opportunity for non-invasive monitoring of cortisol through saliva.