Latest Publications

  • Open Access

    Analysis of Breakdown Phenomena of SF6-Gas Using Different Electrodes Configuration in High Voltage Application

    by Sharafat Ullah, Muhammad Adeel Khan, Irshad Ullah, Azhar Qazi, Zaheer Farooq

    This research investigates the breakdown voltage of SF6 gas using several electrode configurations, including Sphere-sphere, Rod-rod, Plate-plate, Sphere-plate, and Rod-plate, to guarantee sufficient clearance for an acceptable insulation level. The objective of the various electrode geometries is to produce a homogeneous and non-homogeneous electric field wherein the SF6 gas breakdown could be analyzed. The simulation under the influence of six gaps length be-tween electrodes (0.5cm, 1cm, 2cm, 3cm, 4cm, 5cm) were conducted. The lowest breakdown voltage is found in the Rod-rod electrode arrangement, followed by Plate-plate and Sphere-sphere electrode configuration. Compared with the Sphere-sphere electrode design, the Rod-rod electrode configuration is also asymmetric, with a substantially more inhomogeneous electric field. Based on the results, the Rod-plate and Sphere-plate arrangements appear to be asymmetrical. In the event of discharge and breakdown voltage, different electrode configurations have a significant influence. This study helps to identify the most suitable clearance and electrodes configuration in high voltage SF6 circuit breakers. A few researches were performed to find the breakdown voltage of SF6 gas in medium voltage applications under homogeneous electric stress. Some research paper also studied to find the breakdown voltage of SF6 gas under different temperature and pressure. However, this paper is based on finding out the breakdown voltage of SF6 gas in high voltage application providing homogeneous and non-homogeneous electric stress. This homogeneous and non-homogeneous electric field is designed using different electrodes configuration.


  • Open Access

    Deviation of Frequency and Inertia with penetration of Renewable

    by Muhammad Adeel Khan, Irshad Ullah, Azhar Qazi, Muhammad Uzair, Syed Zeeshan Ahmad

    Inertia response is a function of bulky synchronous generators with large rotating rotor masses that cover the instantaneous difference between supply and grid demand, typically in power grids. The rotor rotation frequency helps speed up or slow down the rotor rotation due to the lack of adequate gap between the power supply and the electrical power demand. When demand increases or a fault occurs, or load fluctuations exceed the balance of supply and demand, grid inertia is always induced at this stage. This helps the automatic grid operator rebalance the system to avoid speed drifts, resulting in a relatively small change in AC frequency over the system's frequency range. But the system consists of a system with low or zero inertia, like the wind, it lacks the effect of inertia and could not gain equilibrium. So, to balance and to reach the target frequency; the frequency deviation of the system due to the lack of inertia of the wind turbine is improved by the droop control technique in this research because the wind system reduced the total inertia of the system. Droop rate control mode for AC generator techniques was used to control the frequency fluctuations due to the lack of inertia of the renewable energy system. A synchronous generator connected to the mains was used as the governor control mode. It works by controlling power generation using the mains frequency of the prime mover. This mode allows synchronous generators to run in parallel and share the loads with the same drooping technique in proportion to their rated output. Injected grid inertia increased generator inertia on large power grids.


  • Open Access

    An Experimental Study of Electromagnetic Field Propagation Due to Lightning Upward Leaders and Its Probability on Different Small-Scale Structures

    by Irshad Ullah, Mohd Nor Ramdon Bin Bahrom, Muhammad Adeel Khan, Azhar Qazi

    In this paper, upward leader initiation and the probability of lightning flashes on different air terminal were analyzed in detail. With the growing global warming, lightning flash density has increased abruptly, especially in tropical countries. Upward leaders are the critical elements to be considered for defining comprehensive protective measures against lightning during thunderstorms. This article presents the lightning flashover phenomenon on scaled buildings with installed lightning rods. Moreover, the electric field and initialization of upward leaders from Lightning Air Terminals (LATs) were analyzed in detail using Ansys Maxwell as a simulation tool. For the experimental work, a high-voltage impulse generator was used. The air gap between the lightning rods and the top electrode was kept constant in all scaled structures. The purpose of using an identical air gap was to study the upward leader and its electric field for all structures. The effects of the upward leaders on the electric field plots are explained in detail and allowed the determination of the electric field’s intensity around each air terminal for the provided air gap between the tip of the rod and the top electrode. A low-cost lightning protection system was taken into account, as the economic crisis is worsening with time. A Franklin rod was used as the primary protection device for the initiation of the upward streamer. The experimental results were obtained in Malaysian weather conditions based on standard values of temperature and pressure. The study presented in this article shows that based on the experimental work, field plots were obtained for both the air insulation scenario and the condition when the upward leader was incepted. The simulation results showed a firm agreement with the measured values. Similarly, by upward leader inception, the strikes could be predicted accurately on every installed air terminal.