Huining Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Huining Wang has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Anlin Li
School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou, PR China
1 shared publicationBaiRui Zeng
School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou, PR China
1 shared publication- Bencang Cui
State Key Laboratory of New Ceramics and Fine Processing School of Materials Science and Engineering Tsinghua University 100084 Beijing China
1 shared publication - Cheng Sun
School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325027, China
1 shared publication - Hui Deng
Department of Periodontics, School & Hospital of Stomatology, Wenzhou Medical University, Wenzhou, Zhejiang 325027, China
1 shared publication - Jianfeng Ma
Institute of Stomatology, School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou, China
1 shared publication
Latest Publications
- Open Access
- 8 December 2023
- Published by Springer Nature in BMC Oral Health
- Vol. 23 (1) , 1-13
Evaluation of two treatment concepts of four implants supporting fixed prosthesis in an atrophic maxilla: finite element analysis
Currently, oblique placement of long implants or the use of short implants to circumvent the maxillary sinus area and provide support for fixed prostheses are viable alternatives. The purpose of this study was to compare these two treatment concepts and ascertain which one exhibits superior biomechanical characteristics. Two different treatment concept models were constructed. The first one, LT4I, consisting of two mesial vertical implants positioned in lateral incisor regions and two distal tilted implants (45°) situated in second premolar regions of the maxilla. The second model, VS4I, includes two mesial vertical implants in lateral incisor regions and two vertically positioned short implants in second premolar regions. Numerical simulations were conducted under three loading types: firstly, oblique forces upon the molars; secondly, vertical forces upon the molars; thirdly, oblique forces upon the incisors. The maximum principal stress (σmax) and minimum principal stress (σmin) of the bone, as well as von Mises stress of the implants, were calcuated. Under oblique loading on the molar, higher stress values in the bone were observed in LT4I group. Under vertical loading on molar, higher stress values in the bone were also observed in LT4I group. Furthermore, little difference was found between the two groups under oblique loading on the incisor. Both treatment concepts can be applicable for edentulous individuals with moderate atrophic maxilla. Compared to tilted implants, short implants can transmit less occlusal force to the supporting tissues.
- 8 December 2023
- Published by Springer Nature in BMC Oral Health
- Vol. 23 (1) , 1-13
Open AccessEvaluation of two treatment concepts of four implants supporting fixed prosthesis in an atrophic maxilla: finite element analysis
Currently, oblique placement of long implants or the use of short implants to circumvent the maxillary sinus area and provide support for fixed prostheses are viable alternatives. The purpose of this study was to compare these two treatment concepts and ascertain which one exhibits superior biomechanical characteristics. Two different treatment concept models were constructed. The first one, LT4I, consisting of two mesial vertical implants positioned in lateral incisor regions and two distal tilted implants (45°) situated in second premolar regions of the maxilla. The second model, VS4I, includes two mesial vertical implants in lateral incisor regions and two vertically positioned short implants in second premolar regions. Numerical simulations were conducted under three loading types: firstly, oblique forces upon the molars; secondly, vertical forces upon the molars; thirdly, oblique forces upon the incisors. The maximum principal stress (σmax) and minimum principal stress (σmin) of the bone, as well as von Mises stress of the implants, were calcuated. Under oblique loading on the molar, higher stress values in the bone were observed in LT4I group. Under vertical loading on molar, higher stress values in the bone were also observed in LT4I group. Furthermore, little difference was found between the two groups under oblique loading on the incisor. Both treatment concepts can be applicable for edentulous individuals with moderate atrophic maxilla. Compared to tilted implants, short implants can transmit less occlusal force to the supporting tissues.
- Open Access
Mechanical Properties and In Vitro Biocompatibility of Hybrid Polymer-HA/BAG Ceramic Dental Materials
The aim of this study is to prepare hybrid polymer–ceramic dental materials for chairside computer-aided design/computer-aided manufacturing (CAD/CAM) applications. The hybrid polymer–ceramic materials were fabricated via infiltrating polymerizable monomer mixtures into sintered hydroxyapatite/bioactive glass (HA/BAG) ceramic blocks and thermo-curing. The microstructure was observed by scanning electron microscopy and an energy-dispersive spectrometer. The phase structure was analyzed by X-ray diffraction. The composition ratio was analyzed by a thermogravimetric analyzer. The hardness was measured by a Vickers hardness tester. The flexural strength, flexural modulus, and compressive strength were measured and calculated by a universal testing machine. The growth of human gingival fibroblasts was evaluated by a 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide (MTT) colorimetric assay and immunofluorescence staining. The results showed that the sintering temperature and BAG content affected the mechanical properties of the hybrid polymer–ceramic materials. The X-ray diffraction analysis showed that high-temperature sintering promoted the partial conversion of HA to β-tricalcium phosphate. The values of the hardness, flexural strength, flexural modulus, and compressive strength of all the hybrid polymer–ceramic materials were 0.89–3.51 GPa, 57.61–118.05 MPa, 20.26–39.77 GPa, and 60.36–390.46 MPa, respectively. The mechanical properties of the hybrid polymer–ceramic materials were similar to natural teeth. As a trade-off between flexural strength and hardness, hybrid polymer–ceramic material with 20 wt.% BAG sintered at 1000 °C was the best material. In vitro experiments confirmed the biocompatibility of the hybrid polymer–ceramic material. Therefore, the hybrid polymer–ceramic material is expected to become a new type of dental restoration material.
Open AccessMechanical Properties and In Vitro Biocompatibility of Hybrid Polymer-HA/BAG Ceramic Dental Materials
The aim of this study is to prepare hybrid polymer–ceramic dental materials for chairside computer-aided design/computer-aided manufacturing (CAD/CAM) applications. The hybrid polymer–ceramic materials were fabricated via infiltrating polymerizable monomer mixtures into sintered hydroxyapatite/bioactive glass (HA/BAG) ceramic blocks and thermo-curing. The microstructure was observed by scanning electron microscopy and an energy-dispersive spectrometer. The phase structure was analyzed by X-ray diffraction. The composition ratio was analyzed by a thermogravimetric analyzer. The hardness was measured by a Vickers hardness tester. The flexural strength, flexural modulus, and compressive strength were measured and calculated by a universal testing machine. The growth of human gingival fibroblasts was evaluated by a 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide (MTT) colorimetric assay and immunofluorescence staining. The results showed that the sintering temperature and BAG content affected the mechanical properties of the hybrid polymer–ceramic materials. The X-ray diffraction analysis showed that high-temperature sintering promoted the partial conversion of HA to β-tricalcium phosphate. The values of the hardness, flexural strength, flexural modulus, and compressive strength of all the hybrid polymer–ceramic materials were 0.89–3.51 GPa, 57.61–118.05 MPa, 20.26–39.77 GPa, and 60.36–390.46 MPa, respectively. The mechanical properties of the hybrid polymer–ceramic materials were similar to natural teeth. As a trade-off between flexural strength and hardness, hybrid polymer–ceramic material with 20 wt.% BAG sintered at 1000 °C was the best material. In vitro experiments confirmed the biocompatibility of the hybrid polymer–ceramic material. Therefore, the hybrid polymer–ceramic material is expected to become a new type of dental restoration material.